Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ultrasonics ; 53(4): 880-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23347593

RESUMEN

Incident acoustic output (IAO) dependent subharmonic signal amplitudes from ultrasound contrast agents can be categorized into occurrence, growth or saturation stages. Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes growth stage subharmonic signal amplitudes for hydrostatic pressure estimation. In this study, we developed an automated IAO optimization algorithm to identify the IAO level eliciting growth stage subharmonic signals and also studied the effect of pulse length on SHAPE. This approach may help eliminate the problems of acquiring and analyzing the data offline at all IAO levels as was done in previous studies and thus, pave the way for real-time clinical pressure monitoring applications. The IAO optimization algorithm was implemented on a Logiq 9 (GE Healthcare, Milwaukee, WI) scanner interfaced with a computer. The optimization algorithm stepped the ultrasound scanner from 0% to 100% IAO. A logistic equation fitting function was applied with the criterion of minimum least squared error between the fitted subharmonic amplitudes and the measured subharmonic amplitudes as a function of the IAO levels and the optimum IAO level was chosen corresponding to the inflection point calculated from the fitted data. The efficacy of the optimum IAO level was investigated for in vivo SHAPE to monitor portal vein (PV) pressures in 5 canines and was compared with the performance of IAO levels, below and above the optimum IAO level, for 4, 8 and 16 transmit cycles. The canines received a continuous infusion of Sonazoid microbubbles (1.5 µl/kg/min; GE Healthcare, Oslo, Norway). PV pressures were obtained using a surgically introduced pressure catheter (Millar Instruments, Inc., Houston, TX) and were recorded before and after increasing PV pressures. The experiments showed that optimum IAO levels for SHAPE in the canines ranged from 6% to 40%. The best correlation between changes in PV pressures and in subharmonic amplitudes (r=-0.76; p=0.24), and between the absolute PV pressures and the subharmonic amplitudes (r=-0.89; p<0.01) were obtained for the optimized IAO and 4 transmit cycles. Only for the optimized IAO and 4 transmit cycles did the subharmonic amplitudes differ significantly (p<0.01) before and after increasing PV pressures. A new algorithm to identify optimum IAO levels for SHAPE has been developed and validated with the best results being obtained for 4 transmit cycles. The work presented in this study may pave the way for real-time clinical applications of estimating pressures using the subharmonic signals from ultrasound contrast agents.


Asunto(s)
Algoritmos , Determinación de la Presión Sanguínea/métodos , Medios de Contraste/química , Compuestos Férricos/química , Hierro/química , Óxidos/química , Presión Portal/fisiología , Vena Porta/diagnóstico por imagen , Ultrasonografía/métodos , Acústica , Animales , Perros , Aumento de la Imagen/métodos
2.
Ultrasonics ; 51(8): 890-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21621239

RESUMEN

OBJECTIVE: To demonstrate the feasibility of simultaneous dual fundamental grayscale and subharmonic imaging on a modified commercial scanner. MOTIVATION: The ability to generate signals at half the insonation frequency is exclusive to ultrasound contrast agents (UCA). Thus, subharmonic imaging (SHI; transmitting at f(0) and receiving at f(0)/2) provides improved visualization of UCA within the vasculature via suppression of the surrounding tissue echoes. While this capability has proven useful in a variety of clinical applications, the SHI suppression of surrounding tissue landmarks (which are needed for sonographic navigation) also limits it use as a primary imaging modality. In this paper we present results using a commercial ultrasound scanner modified to allow imaging in both grayscale (f(0)=4.0 MHz) and SHI (f(0)=2.5 MHz, f(0)/2=1.25 MHz) modes in real time. METHODS: A Logiq 9 ultrasound scanner (GE Healthcare, Milwaukee, WI) with a 4C curvilinear probe was modified to provide this capability. Four commercially available UCA (Definity, Lantheus Medical Imaging, North Billerica, MA; Optison, GE Healthcare, Princeton, NJ; SonoVue, Bracco Imaging, Milan, Italy; and Sonazoid, GE Healthcare, Oslo, Norway) were all investigated in vitro over an acoustic output range of 3.34 MPa. In vivo the subharmonic response of Sonazoid was investigated in the portal veins of four canines (open abdominal cavity) and four patients with suspected portal hypertension. RESULTS: In vitro, the four UCA showed an average maximum subharmonic amplitude of 44.1±5.4 dB above the noise floor with a maximum subharmonic amplitude of 48.6±1.6 dB provided by Sonazoid. The average in vivo maximum signal above the noise floor from Sonazoid was 20.8±2.3 dB in canines and 33.9±5.2 dB in humans. Subharmonic amplitude as a function of acoustic output in both groups matched the S-curve behavior of the agent observed in vitro. The dual grayscale imaging provided easier sonographic navigation, while the degree of tissue suppression in SHI mode varied greatly on a case by case basis. CONCLUSIONS: These results demonstrate the feasibility of dual grayscale and SHI on a modified commercial scanner. The ability to simultaneously visualize both imaging modes in real time should improve the applicability of SHI as a future primary clinical imaging modality.


Asunto(s)
Medios de Contraste/farmacocinética , Hipertensión Portal/diagnóstico por imagen , Ultrasonografía/instrumentación , Albúminas/farmacocinética , Análisis de Varianza , Animales , Perros , Estudios de Factibilidad , Compuestos Férricos/farmacocinética , Fluorocarburos/farmacocinética , Humanos , Hierro/farmacocinética , Óxidos/farmacocinética , Fosfolípidos/farmacocinética , Proyectos Piloto , Hexafluoruro de Azufre/farmacocinética
3.
Artículo en Inglés | MEDLINE | ID: mdl-18986948

RESUMEN

A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/instrumentación , Cateterismo Cardíaco/instrumentación , Ecocardiografía/instrumentación , Aumento de la Imagen/instrumentación , Imagenología Tridimensional/instrumentación , Transductores , Ultrasonografía Intervencional/instrumentación , Animales , Mapeo del Potencial de Superficie Corporal/métodos , Cateterismo Cardíaco/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos , Integración de Sistemas
4.
Ultrason Imaging ; 21(2): 79-94, 1999 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10485563

RESUMEN

The subharmonic emission from insonified contrast microbubbles was used to create a new imaging modality called Subharmonic Imaging. The subharmonic response of contrast microbubbles to ultrasound pulses was first investigated for determining adequate acoustic transmit parameters. Subharmonic A-lines and gray scale images were then obtained using a laboratory pulse-echo system in vitro and a modified ultrasound scanner in vivo. Excellent suppression of all backscattered signals other than from contrast microbubbles was achieved for subharmonic A-lines in vitro while further optimization is required for in vivo gray scale subharmonic images.


Asunto(s)
Medios de Contraste/administración & dosificación , Riñón/diagnóstico por imagen , Animales , Velocidad del Flujo Sanguíneo , Perros , Procesamiento de Imagen Asistido por Computador , Inyecciones Intravenosas , Riñón/irrigación sanguínea , Fantasmas de Imagen , Arteria Renal/diagnóstico por imagen , Venas Renales/diagnóstico por imagen , Ultrasonografía
5.
Artículo en Inglés | MEDLINE | ID: mdl-18244162

RESUMEN

Range sidelobe artifacts which are associated with pulse compression methods can be reduced with a new method composed of pulse elongation and deconvolution (PED). While pulse compression and PED yield similar signal-to-noise ratio (SNR) improvements, PED inherently minimizes the range sidelobe artifacts. The deconvolution is implemented as a stabilized inverse filter. With proper selection of the excitation waveform an exact inverse filter can be implemented. The excitation waveform is optimized in a minimum mean square error (MMSE) sense. An analytical expression for the power spectrum of the optimal pulse is presented and several techniques to numerically optimize the excitation pulse are shown. The effects of PED are demonstrated in computer simulations as well as ultrasonic images.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA