Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Heart Rhythm ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39053748

RESUMEN

BACKGROUND: High-frequency, low-tidal volume (HFLTV) ventilation increases the efficacy and efficiency of radiofrequency catheter ablation (RFCA) of paroxysmal atrial fibrillation. Whether those benefits can be extrapolated to RFCA of persistent atrial fibrillation (PeAF) is undetermined. OBJECTIVE: The purpose of this study was to evaluate whether using HFLTV ventilation during RFCA in patients with PeAF is associated with improved procedural and long-term clinical outcomes compared to standard ventilation (SV). METHODS: In this prospective multicenter registry (REAL-AF), patients who had undergone pulmonary vein isolation (PVI) + posterior wall isolation (PWI) for PeAF using either HFLTV ventilation or SV were included. The primary efficacy outcome was freedom from all-atrial arrhythmias at 12 months. Secondary outcomes included procedural and long-term clinical outcomes and complications. RESULTS: A total of 210 patients were included (HFLTV=95 vs. SV=115) in the analysis. There were no differences in baseline characteristics between the groups. Procedural time (80 [66-103.5] minutes vs 110 [85-141] minutes; P <.001), total radiofrequency (RF) time (18.73 [13.93-26.53] minutes vs 26.15 [20.30-35.25] minutes; P <.001), and pulmonary vein RF time (11.35 [8.78-16.69] minutes vs 18 [13.74-24.14] minutes; P <.001) were significantly shorter using HFLTV ventilation compared with SV. Freedom from all-atrial arrhythmias was significantly higher with HFLTV ventilation compared with SV (82.1% vs 68.7%; hazard ratio 0.41; 95% confidence interval [0.21-0.82]; P = .012), indicating a 43% relative risk reduction and a 13.4% absolute risk reduction in all-atrial arrhythmia recurrence. There was no difference in long-term procedure-related complications between the groups (HFLTV 1.1% vs SV 0%, P = .270). CONCLUSION: In patients undergoing RFCA with PVI + PWI for PeAF, the use of HFLTV ventilation was associated with higher freedom from all-atrial arrhythmias at 12-month follow-up, with significantly shorter procedural and RF times compared to SV, while reporting a similar safety profile.

2.
Phys Med ; 115: 103160, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37847954

RESUMEN

PURPOSE: Identifying the target region is critical for successfully treating ventricular tachycardia (VT) with single fraction stereotactic arrhythmia radioablation (STAR). We report the feasibility of target definition based on direct co-registration of electroanatomic maps (EAM) and radioablation planning images. MATERIALS AND METHODS: The EAM consists of 3D cardiac anatomy representation with electrical activity at endocardium and is acquired by a cardiac electrophysiologist (CEP) during electrophysiology study. The CEP generates an EAM using a 3D cardiac mapping system anticipating radioablation planning. Our in-house software read these non-DICOM EAMs, registered them to a planning image set, and converted them to DICOM structure files. The EAM based target volume was finalized based on a consensus of CEPs, radiation oncologists and medical physicists, then expanded to ITV and PTV. The simulation, planning, and treatment is performed with a standard STAR technique: a single fraction of 25 Gy using volumetric-modulated arc therapy or dynamic conformal arc therapy depending on the target shape. RESULTS: Seven patients with refractory VT were treated by defining the target based on registering EAMs on the planning images. Dice similarity indices between reference map and reference contours after registration were 0.814 ± 0.053 and 0.575 ± 0.199 for LV and LA/RV, respectively. CONCLUSIONS: The quality of the transferred EAMs on the MR/CT images was sufficient to localize the treatment region. Five of 7 patients demonstrated a dramatic reduction in VT events after 6 weeks. Longer follow-up is required to determine the true safety and efficacy of this therapy using EAM-based direct registration method.


Asunto(s)
Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Taquicardia Ventricular , Humanos , Corazón , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/radioterapia , Imagenología Tridimensional , Radioterapia de Intensidad Modulada/métodos
3.
JAMA Intern Med ; 183(10): 1154-1155, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37548982

RESUMEN

This case report presents the electrocardiogram findings of a patient in their 50s with sudden onset, severe palpitations lasting for 2 hours.


Asunto(s)
Electrocardiografía , Taquicardia , Humanos , Taquicardia/diagnóstico
5.
J Arrhythm ; 35(1): 7-17, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30805039

RESUMEN

In 1967, researchers in The Netherlands and France independently reported a new technique, later called programmed electrical stimulation. The ability to reproducibly initiate and terminate arrhythmias heralded the beginning of invasive clinical cardiac electrophysiology as a medical discipline. Over the next fifty years, insights into the pathophysiologic basis of arrhythmias would transform the field into an interventional specialty with a tremendous armamentarium of procedures. In 2015, the variety and complexity of these procedures were major reasons that led to the recommendation for an increase in the training period from one year to two years. The purpose of this manuscript is to present fifty manuscripts from the early invasive clinical cardiac electrophysiology era, between 1967 and 1992, to serve as an educational resource for current and future electrophysiologists. It is our hope that reflection on the transition from a predominantly noninvasive discipline to one where procedures are commonly utilized will lead to more thoughtful patient care today and to inspiration for innovation tomorrow. In the words of the late Dr. Mark E. Josephson, "It is only by getting back to the basics that the field of electrophysiology will continue to grow instead of stagnate."

7.
J Artif Organs ; 20(2): 174-177, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28286902

RESUMEN

Ventricular tachycardia (VT) in the setting of left ventricular assist device (LVAD) therapy has been well described. We present a case of incessant ventricular tachycardia resulting in severe right ventricular (RV) failure and subsequent left ventricular (LV) cavity obliteration, which in turn diminished the feasibility of initial attempt at VT ablation.


Asunto(s)
Ablación por Catéter , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Taquicardia Ventricular/terapia , Anciano , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Taquicardia Ventricular/complicaciones , Insuficiencia del Tratamiento
9.
Arrhythm Electrophysiol Rev ; 2(1): 65-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26835043

RESUMEN

The closed chest convergent procedure is a multidisciplinary approach to atrial fibrillation (AF) treatment. Epicardial posterior left atrial (PLA) ablation is performed by a cardiac surgeon using a transdiaphragmatic endoscope, immediately followed by percutaneous pulmonary vein (PV) isolation performed by a cardiac electrophysiologist. Interim outcomes for the treatment of non-paroxysmal AF (NPAF) were evaluated based on peri-procedural safety and complications, freedom from recurrent AF, and need for cardioversion or repeat catheter ablation at three, six and 12 months post-procedure. A total of 43 patients (86 % NPAF) underwent the convergent procedure. Patients were 84 % male, with mean age 58.6 ± 8.7 years. Mean AF duration was 45.4 ± 40.3 months. Pre-procedure left atrium (LA) volumetric data using cardiac magnetic resonance imaging (MRI) or computed tomography (CT) was available for 30 patients (70 %). Average LA volume was 155.5 ± 48.4 millilitres (ml); two-thirds of patients had a LA volume >130 ml. There was no operative or peri-operative mortality. Sinus rhythm (SR) was recorded at three months in 31 of 39 (79 %) patients, at six months in 24 of 27 (89 %) patients and at 12 months in nine patients. The convergent procedure is a safe and effective option for both PV isolation and PLA substrate ablation in NPAF patients. Long-term follow-up is required and randomised clinical trials warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA