Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 75
1.
Contraception ; : 110440, 2024 Mar 27.
Article En | MEDLINE | ID: mdl-38552818

OBJECTIVES: Evaluate the safety of Ovaprene, an investigational nonhormonal vaginal contraceptive designed for monthly use. STUDY DESIGN: Open-label, multicenter study enrolling heterosexually-active women with previous permanent contraception who underwent assessments during five menstrual cycles: baseline postcoital test cycle, diaphragm postcoital test cycle, Ovaprene safety cycle, and two Ovaprene postcoital test cycles. Safety outcomes included treatment-emergent adverse events, systemic laboratory findings, pelvic examinations, colposcopies, Nugent scores, determination of community state types of vaginal microbiota, and anti-Escherichia coli activity and inflammatory markers in cervicovaginal fluids. RESULTS: We enrolled 38 participants. Of these, 33 used Ovaprene and completed 77 Ovaprene cycles. The most common product-related urogenital treatment-emergent adverse events were bacterial vaginosis and vaginal odor. The frequency of transitioning from Lactobacillus-dominated community state type to community state type IV (not Lactobacillus-dominated) was similar before Ovaprene use and afterwards. Mean Nugent scores were <4 at each visit without a discernible upward trend. Inflammatory markers showed wide variation but no upward trend, and E. coli inhibitory activity of cervical secretions did not change. We found no Staphylococcus aureus, the causative agent in toxic shock syndrome, on used Ovaprenes or in vaginal samples. No clinically important changes in systemic laboratory findings, pelvic examinations, or colposcopies occurred during Ovaprene use. CONCLUSIONS: Ovaprene use did not result in cervicovaginal irritation or adverse effects on resident vaginal microbiota and did not impact transitions from a Lactobacillus-dominated community state type to community state type IV. IMPLICATIONS: The finding that the use of Ovaprene, an investigational monthly user-controlled nonhormonal vaginal contraceptive, does not appear to result in adverse changes in vaginal health during short-term use supports further evaluation of the contraceptive potential of the device.

3.
J Int AIDS Soc ; 27(3): e26223, 2024 Mar.
Article En | MEDLINE | ID: mdl-38444118

INTRODUCTION: Tenofovir-based oral pre-exposure prophylaxis is currently approved for HIV prevention; however, adherence in women has been low. A vaginal gel containing tenofovir (TFV) demonstrated partial protection to HIV but protection was not confirmed in additional studies. Vaginal rings offer user-controlled long-acting HIV prevention that could overcome adherence and protection challenges. TFV may also help prevent herpes simplex virus type 2 acquisition when delivered intravaginally. We evaluated the pharmacokinetics, safety, adherence and acceptability of a 90-day TFV ring. METHODS: Between January and June 2019, Microbicide Trials Network (MTN)-038 enrolled 49 HIV-negative participants into a phase 1, randomized (2:1) trial comparing a 90-day ring containing 1.4 grams (g) TFV to a placebo ring. TFV concentrations were quantified in plasma, cervicovaginal fluid (CVF), rectal fluid and cervical tissue, and TFV-diphosphate (TFV-DP) in cervical tissue. Used rings were analysed for residual TFV. Safety was assessed by adverse events (AEs); acceptability and adherence by self-report. RESULTS: Mean age was 29.5; 46 identified as cisgender-female and three gender non-conforming. There were no differences in the proportion of participants with grade ≥2 genitourinary AEs in the TFV versus placebo arms (p = 0.41); no grade ≥3 AEs were reported. Geometric mean TFV concentrations increased through day 34 in CVF/rectal fluid and day 59 in plasma, but declined across compartments by day 91. Geometric mean TFV-DP tissue concentrations exceeded the 1000 fmol/mg target through day 56, but fell to 456 fmol/mg at day 91. Among 32 rings returned at the end of the study, 13 had no or low (<0.1 g) residual TFV. Residual TFV did not differ by socio-demographics, sexual activity, Nugent Score or vaginal microbiota. Most participants reported being fully adherent to ring use: 85% and 81% in the TFV and placebo arms, respectively (p = 1.00). A majority of participants reported liking the ring (median 8 on a 10-point Likert scale) and reported a high likelihood of using the ring in the future, if effective (median 9). CONCLUSIONS: The 90-day TFV ring was well-tolerated, acceptable and exceeded target cervical tissue concentrations through day 56, but declined thereafter. Additional studies are needed to characterize the higher release from TFV rings in some participants and the optimal duration of use.


HIV Infections , Tenofovir , Adult , Female , Humans , Adenine , Herpesvirus 2, Human , HIV Infections/drug therapy , HIV Infections/prevention & control , Microbiota , Tenofovir/adverse effects , Tenofovir/pharmacokinetics , United States
4.
Contraception ; 132: 110373, 2024 04.
Article En | MEDLINE | ID: mdl-38232942

OBJECTIVE: Evaluate reduction in progressively motile sperm per high power field (HPF) in midcycle cervical mucus after intercourse with Ovaprene: an investigational monthly non-hormonal vaginal contraceptive consisting of a vaginal ring and mechanical barrier, releasing spermiostatic ferrous gluconate. STUDY DESIGN: Open-label, multicenter study enrolling heterosexually-active women with previous permanent contraception. Participants underwent a baseline postcoital test cycle with no device to confirm the presence of sperm, followed by one diaphragm postcoital test cycle, one Ovaprene safety cycle, and two Ovaprene postcoital test cycles. In each postcoital test cycle, participants underwent a midcycle cervical mucus evaluation to confirm an Insler score ≥10 and absence of sperm, and then returned two to four hours after vaginal intercourse for repeat cervical mucus evaluation. We considered <5 progressively motile sperm/HPF indicative of preliminary contraceptive effectiveness. RESULTS: We enrolled 38 participants; 23 completed the study. All participants had ≥5 progressively motile sperm/HPF in the baseline cycle and <5 progressively motile sperm/HPF in all 49 Ovaprene cycles and all 35 diaphragm cycles, meeting the definition of a successful postcoital test. This was true regardless of examiner blinding, prior vaginal delivery or vaginal ring use, body mass index, or dislodgements noted by the participant or investigator. The mean of 27.2 (±17.9) progressively motile sperm/HPF in baseline postcoital test cycles was reduced to 0.5 (±1.1) and 0.5 (±1.3) progressively motile sperm/HPF in the first and second Ovaprene cycles, respectively. Ovaprene fit all participants and all could insert, position, and remove it. CONCLUSION: Use of Ovaprene resulted in meeting the prespecified criterion for contraceptive effect by all participants during all postcoital test cycles. IMPLICATIONS: The finding that use of Ovaprene, an investigational monthly non-hormonal vaginal contraceptive, resulted in postcoital testing of cervical mucus that met the pre-specified definition of success (<5 progressively motile sperm/HPF) supports further evaluation of contraceptive efficacy of the device in users at risk for pregnancy.


Contraceptive Devices, Female , Semen , Male , Pregnancy , Humans , Female , Vagina , Body Mass Index , Contraceptive Agents
6.
Menopause ; 30(9): 940-946, 2023 09 01.
Article En | MEDLINE | ID: mdl-37625088

OBJECTIVES: The exploratory objectives of this study were to evaluate the usability and acceptability and to conduct a preliminary evaluation of the efficacy of DARE-HRT1. DARE-HRT1 is an intravaginal ring (IVR) that releases 17ß2-estradiol (E2) with progesterone (P4) over 28 days. It is the first combination E2 and P4 IVR being developed for the treatment of vasomotor symptoms (VMS) in healthy postmenopausal women with an intact uterus. METHODS: This was a randomized, open-label, 2-arm, parallel group study in 21 healthy postmenopausal women. Women were randomized (1:1) to either DARE-HRT1 IVR1 (E2 80 µg/d with P4 4 mg/d) or DARE-HRT1 IVR2 (E2 160 µg/d with P4 8 mg/d). They used the assigned IVR for three 28-day cycles, inserting a new IVR monthly. Preliminary genitourinary syndrome of menopause (GSM) treatment efficacy was estimated by measuring changes from baseline in vaginal pH, vaginal maturation index (VMI), and changes in the severity of GSM symptoms. Preliminary systemic VMS efficacy was measured by changes in responses to the Menopause-Specific Quality of Life (MENQOL) questionnaire. Acceptability was assessed by product experience surveys. RESULTS: Preliminary local GSM treatment efficacy was supported by significant decreases in vaginal pH and % parabasal cells, and significant increases in the overall VMI and % superficial cells for both IVR groups (all P values <0.01). Preliminary VMS efficacy was supported by significant decreases in all domains of the MENQOL questionnaire from baseline for both dosing groups (all P values <0.01). CONCLUSIONS: Data from this study support further development of DARE-HRT1 for the treatment of menopausal symptoms.


Progesterone , Quality of Life , Humans , Female , Postmenopause , Health Status , Estradiol
8.
Front Reprod Health ; 5: 1118030, 2023.
Article En | MEDLINE | ID: mdl-37383290

Introduction: Globally, many young women face the overlapping burden of HIV infection and unintended pregnancy. Protection against both may benefit from safe and effective multipurpose prevention technologies. Methods: Healthy women ages 18-34 years, not pregnant, seronegative for HIV and hepatitis B surface antigen, not using hormonal contraception, and at low risk for HIV were randomized 2:2:1 to continuous use of a tenofovir/levonorgestrel (TFV/LNG), TFV, or placebo intravaginal ring (IVR). In addition to assessing genital and systemic safety, we determined TFV concentrations in plasma and cervicovaginal fluid (CVF) and LNG levels in serum using tandem liquid chromatography-mass spectrometry. We further evaluated TFV pharmacodynamics (PD) through ex vivo CVF activity against both human immunodeficiency virus (HIV)-1 and herpes simplex virus (HSV)-2, and LNG PD using cervical mucus quality markers and serum progesterone for ovulation inhibition. Results: Among 312 women screened, 27 were randomized to use one of the following IVRs: TFV/LNG (n = 11); TFV-only (n = 11); or placebo (n = 5). Most screening failures were due to vaginal infections. The median days of IVR use was 68 [interquartile range (IQR), 36-90]. Adverse events (AEs) were distributed similarly among the three arms. There were two non-product related AEs graded >2. No visible genital lesions were observed. Steady state geometric mean amount (ssGMA) of vaginal TFV was comparable in the TFV/LNG and TFV IVR groups, 43,988 ng/swab (95% CI, 31,232, 61,954) and 30337 ng/swab (95% CI, 18,152, 50,702), respectively. Plasma TFV steady state geometric mean concentration (ssGMC) was <10 ng/ml for both TFV IVRs. In vitro, CVF anti-HIV-1 activity showed increased HIV inhibition over baseline following TFV-eluting IVR use, from a median of 7.1% to 84.4% in TFV/LNG, 15.0% to 89.5% in TFV-only, and -27.1% to -20.1% in placebo participants. Similarly, anti-HSV-2 activity in CVF increased >50 fold after use of TFV-containing IVRs. LNG serum ssGMC was 241 pg/ml (95% CI 185, 314) with rapid rise after TFV/LNG IVR insertion and decline 24-hours post-removal (586 pg/ml [95% CI 473, 726] and 87 pg/ml [95% CI 64, 119], respectively). Conclusion: TFV/LNG and TFV-only IVRs were safe and well tolerated among Kenyan women. Pharmacokinetics and markers of protection against HIV-1, HSV-2, and unintended pregnancy suggest the potential for clinical efficacy of the multipurpose TFV/LNG IVR. Clinical Trial Registration: NCT03762382 [https://clinicaltrials.gov/ct2/show/NCT03762382].

9.
Menopause ; 30(8): 817-823, 2023 08 01.
Article En | MEDLINE | ID: mdl-37339390

OBJECTIVES: Primary objectives were to evaluate the safety and systemic pharmacokinetics (PK) of DARE-HRT1, an intravaginal ring (IVR), which releases 17ß2-Estradiol (E2) with progesterone (P4) for 28 days in healthy postmenopausal women. METHODS: This was a randomized, open-label, 2-arm, parallel group study in 21 healthy postmenopausal women with an intact uterus. Women were randomized (1:1) to either DARE-HRT1 IVR1 (E2 80 µg/d with P4 4 mg/d) or DARE-HRT1 IVR2 (E2 160 µg/d with P4 8 mg/d). They used the IVR for three 28-day cycles, inserting a new IVR monthly. Safety was measured by treatment emergent adverse events and changes in systemic laboratories and the endometrial bilayer width. Baseline adjusted plasma PK of E2, P4, and estrone (E1) was described. RESULTS: Both DARE-HRT1 IVR were safe. All treatment emergent adverse events were mild or moderate and were distributed similarly among IVR1 versus IVR2 users. Month 3 median maximum plasma ( Cmax ) P4 concentrations were 2.81 and 3.51 ng/mL and Cmax E2 was 42.95 and 77.27 pg/mL for IVR1 and IVR2 groups, respectively. Month 3 median steady state ( Css ) plasma P4 concentrations were 1.19 and 1.89 ng/mL, and Css E2 was 20.73 and 38.16 pg/mL for IVR1 and IVR2 users, respectively. CONCLUSIONS: Both DARE-HRT1 IVRs were safe and released E2 in systemic concentrations, which were in the low, normal premenopausal range. Systemic P4 concentrations predict endometrial protection. Data from this study support further development of DARE-HRT1 for the treatment of menopausal symptoms.


Postmenopause , Progesterone , Female , Humans , Estradiol , Estrone , Premenopause
10.
Front Cell Infect Microbiol ; 13: 1130101, 2023.
Article En | MEDLINE | ID: mdl-37153145

Background: New multi-purpose prevention technology (MPT) products are needed to prevent human immunodeficiency virus (HIV) and herpes simplex virus type 2 (HSV2). In this study, we evaluated a fast-dissolve insert that may be used vaginally or rectally for prevention of infection. Objective: To describe the safety, acceptability, multi-compartment pharmacokinetics (PK), and in vitro modeled pharmacodynamics (PD) after a single vaginal dose of an insert containing tenofovir alafenamide (TAF) and elvitegravir (EVG) in healthy women. Methods: This was a Phase I, open-label, study. Women (n=16) applied one TAF (20mg)/EVG (16mg) vaginal insert and were randomized (1:1) to sample collection time groups for up to 7 days post dosing. Safety was assessed by treatment-emergent adverse events (TEAEs). EVG, TAF and tenofovir (TFV) concentrations were measured in plasma, vaginal fluid and tissue, and TFV-diphosphate (TFV-DP) concentration in vaginal tissue. PD was modeled in vitro by quantifying the change in inhibitory activity of vaginal fluid and vaginal tissue against HIV and HSV2 from baseline to after treatment. Acceptability data was collected by a quantitative survey at baseline and post treatment. Results: The TAF/EVG insert was safe, with all TEAEs graded as mild, and acceptable to participants. Systemic plasma exposure was low, consistent with topical delivery, while high mucosal levels were detected, with median TFV vaginal fluid concentrations exceeding 200,000 ng/mL and 1,000 ng/mL for up to 24 hours and 7 days post dosing, respectively. All participants had vaginal tissue EVG concentrations of > 1 ng/mg at 4 and 24 hours post dosing. The majority had tissue TFV-DP concentrations exceeding 1000 fmol/mg by 24 - 72 hours post dosing. Vaginal fluid inhibition of HIV-1 and HSV-2 in vitro significantly increased from baseline and was similarly high at 4 and 24 hours post dosing. Consistent with high tissue TFV-DP concentrations, p24 HIV antigen production from ectocervical tissues infected ex vivo with HIV-1 significantly decreased from baseline at 4 hours post dosing. HSV-2 production from tissue also decreased post treatment. Conclusions: A single dose of TAF/EVG inserts met PK benchmarks, with PK data supporting an extended window of high mucosal protection. PD modeling supports mucosal protection against both HIV-1 and HSV-2. The inserts were safe and highly acceptable. Clinical trial registration: ClinicalTrials.gov, identifier NCT03762772.


Anti-HIV Agents , HIV Infections , HIV-1 , Humans , Female , Anti-HIV Agents/adverse effects , Tenofovir/adverse effects , Alanine
11.
Front Reprod Health ; 5: 1148134, 2023.
Article En | MEDLINE | ID: mdl-37064825

Introduction: Most women face multiple and co-occurring risks from unwanted pregnancy, human immunodeficiency virus (HIV) and other sexually transmitted infections (STIs) at some point during their lifetime. While a range of contraceptive methods exist and options for HIV prevention are increasing, to date, only male and female condoms provide multipurpose protection from both pregnancy and disease. Methods: From September 2017 to December 2018, 60 women from the United States and the Dominican Republic, randomized 1:1 to continuous or interrupted use and 4:1 to active vs. placebo ring, participated in a Phase I trial to assess the safety and tolerability of a three-month multipurpose intravaginal ring (IVR) containing the antiviral tenofovir and the contraceptive levonorgestrel. This study examines survey responses from all participants and qualitative data from a subset of 17 women to assess acceptability of and preferences for IVR characteristics. Results: Overall, women liked the concept of a multipurpose IVR and found it easy to insert and remove. Initial concerns about the size or thickness of the ring generally disappeared with use experience. Women weighed trade-offs between the ease of continuous use for a longer duration against concerns about hygiene and discoloration of the ring when left in place during menses. Whether randomized to continuous or interrupted use, most women found ring attributes (size, thickness, flexibility) very acceptable. They provided recommendations via survey and qualitative interviews for ring modifications that would further increase acceptability. Insights into women's use experiences also suggest the need for clear counseling messages and introduction strategies that can facilitate women's choice and use of prevention methods. Discussion: Study findings suggest that a multipurpose IVR would make a valuable contribution to women's sexual and reproductive health options, and that both continuous and interrupted use strategies may be preferred.

12.
Am J Obstet Gynecol ; 228(6): 716.e1-716.e12, 2023 06.
Article En | MEDLINE | ID: mdl-36870409

BACKGROUND: With an unplanned pregnancy rate of 50% or more in many countries, there is an urgent need for contraceptives that are more accessible and acceptable. To meet the growing demand for new contraceptives, ZabBio developed ZB-06, a vaginal film containing HC4-N, a human contraceptive antibody that inactivates sperm. OBJECTIVE: This study aimed to assess the potential contraceptive activity of the ZB-06 film using a surrogate assessment for contraceptive efficacy, the postcoital test. We also assessed clinical safety of film use among healthy heterosexual couples. Serum, cervical mucus, and vaginal fluid HC4-N antibody concentrations and sperm agglutination potency were determined after single film use. Changes in the concentration of soluble proinflammatory cytokines and vaginal Nugent score after film use were measured as subclinical safety endpoints. STUDY DESIGN: This was a phase 1, first-in-woman, open-label, proof-of-concept, postcoital test and safety study. RESULTS: A total of 20 healthy women were enrolled in the study, and 8 heterosexual couples completed all study visits. The product was safe for both female participants and their male sexual partners. The postcoital test performed on ovulatory cervical mucus at baseline (no product use) revealed a mean of 25.9 (±30.6) progressively motile sperm per high-power field. After use of a single ZB-06 film before intercourse, this number dropped to 0.04 (±0.06) progressively motile sperm per high-power field (P<.0001). At the follow-up postcoital test visit approximately 1 month later (no product use), a mean of 47.4 (±37.4) progressively motile sperm per high-power field was observed, indicating contraceptive reversibility. CONCLUSION: A single dose of the ZB-06 film applied before intercourse was safe and met efficacy surrogate benchmarks of excluding progressively motile sperm from ovulatory cervical mucus. These data indicate that ZB-06 is a viable contraceptive candidate warranting further development and testing.


Contraceptive Devices, Female , Spermatocidal Agents , Pregnancy , Humans , Male , Female , Contraceptive Agents , Spermatocidal Agents/pharmacology , Semen , Vagina
13.
Am J Obstet Gynecol MFM ; 5(6): 100931, 2023 06.
Article En | MEDLINE | ID: mdl-36965695

BACKGROUND: Intrapartum infection usually warrants immediate delivery and impacts 5-12% of term pregnancies, with the most commonly identified pathogenic organism being of the Ureaplasma genus. When performing cervical examinations during labor, providers in the United States commonly use sterile gloves, although there are no data currently to support that this practice reduces rates of infection. Furthermore, in nearly all other settings of Gynecologic care, aside from surgery in an operating room, nonsterile gloves are used. Even though the uterus could be sterile in normal pregnancies, the provider performing the cervical examination must traverse the milieu of vaginal bacteria in order to reach the cervix to perform the exam, introducing vaginal microbiota into the uterus regardless of the type of glove used. This prospective randomized controlled study examines whether the type of glove used (sterile vs clean) impacts the rates of intrapartum infection in patients receiving cervical examinations during labor or induction of labor at term.. OBJECTIVE: This study aimed to evaluate if the glove type (sterile vs clean) used for cervical examinations during labor affects the rates of intrapartum and postpartum infection. STUDY DESIGN: This randomized controlled trial assigned eligible and consenting participants to receive cervical examinations during labor with either sterile powder-free polyvinyl chloride examination gloves (current routine practice, control group) or clean powder-free nitrile examination gloves (nonsterile, experimental group). The primary outcome was rates of intrapartum infection (chorioamnionitis). Sample size calculations estimated that 300 participants would be needed with a rate of infection of 10% in the control group and 20% in the experimental group to demonstrate difference between the groups; however, the rates of infection were much lower than expected, at 5.4% and 4.4% in the sterile and clean glove group, respectively. At this point, it was determined futile to continue the study because a sample size of >29,000 participants would be needed, which would not be achievable at a single tertiary care referral center with approximately 3500 deliveries per year. The study was approved by the Eastern Virginia Medical School Institutional Review Board (IRB 21-09-FB-0206), and was registered at ClinicalTrials.gov (identifier NCT05603624; https://clinicaltrials.gov/ct2/show/NCT05603624). RESULTS: A total of 163 participants with singleton pregnancies completed the study; 74 (45%) were randomized to the sterile glove group, and 89 (55%) were randomized to the clean glove group. In the sterile glove group, 4 (5.4%) developed intrapartum infection (chorioamnionitis) and 1 (1.3%) developed postpartum infection (endometritis). In the clean glove group, 4 (4.4%) developed intrapartum infection and 2 (2.2%) developed postpartum infection. There was no significant difference in rates of intrapartum infection (P=1.0) or postpartum infection (P=1.0), or combined rates of infection (including both chorioamnionitis and endometritis; P=.99) between the sterile and the clean glove group. When comparing the participants from both groups who had any intrapartum or postpartum infection (n=11) with those who had no infection (n=152), the former were more likely to be nulliparous (P=.01), have lower gravidity (P<.01) and parity (P<.01), have longer times from first cervical examination to delivery (P=.02), have longer times from rupture of membranes to delivery (P=.0001), undergo cesarean delivery (P=.0002), and experience postpartum hemorrhage (P=.001). Although participants who were in labor for a longer time also likely had more cervical examinations, these data could suggest that duration of labor (P=.02) is more closely associated with infectious morbidity compared with the number of cervical examinations (P=.15). CONCLUSION: Using clean gloves for cervical examinations during labor is unlikely to increase risk of infection, and could reduce cost by up to 92.4% at our institution, saving over $25,000 annually.


Chorioamnionitis , Endometritis , Labor, Obstetric , Pregnancy , Humans , Female , Cervix Uteri , Endometritis/etiology , Prospective Studies
14.
BMC Infect Dis ; 22(1): 919, 2022 Dec 08.
Article En | MEDLINE | ID: mdl-36482336

BACKGROUND: While oral pre-exposure prophylaxis (PrEP) has been shown to reduce the risk of HIV, challenges such as adhering to a daily-dosing regimen and persistence have emerged as barriers for at-risks populations in South Africa. This qualitative research sought to investigate perceptions of and preferences for a long-acting, biodegradable implantable PrEP product designed to address these barriers. METHODS: To identify and understand motivators, barriers, and preferences for the PrEP implant, we conducted qualitative in-depth interviews (IDIs) among health care providers (HCPs) and target end-users (young women, adolescent girls, and female sex workers) in urban and rural/peri-urban regions of Gauteng Province, South Africa. The IDIs focused on defining values, beliefs, habits, lifestyles, influencers, and information channels for potential PrEP implant end-users. RESULTS: We conducted 36 IDIs across health care providers and target end-user respondent segments. Respondents had generally positive reactions to the PrEP implant. Most end-users felt that some undesirable aspects of the implant (e.g., side effects, pain during insertion, potential scarring, and inability to remove implant) would be offset by having a highly effective, and long-lasting HIV prevention product. Although some HCPs believed the implantable PrEP would lead to increases in promiscuity and risky sexual behavior, most HCPs saw value in the PrEP implant's long duration of protection, its biodegradability, and the likelihood of higher adherence relative to oral PrEP. CONCLUSIONS: This study is a first step toward further research needed to demonstrate the demand for a biodegradable, long-acting implantable PrEP and suggests such a product would be accepted by end-users and HCPs in South Africa. This study indicates the need to develop more convenient, discreet, long-acting, and highly effective biomedical HIV prevention options for at-risk populations.


HIV Infections , Sex Workers , Female , Humans , Adolescent , South Africa , Qualitative Research , HIV Infections/drug therapy , HIV Infections/prevention & control
15.
BMC Med ; 20(1): 353, 2022 10 05.
Article En | MEDLINE | ID: mdl-36195867

BACKGROUND: Hormonal changes during the menstrual cycle play a key role in shaping immunity in the cervicovaginal tract. Cervicovaginal fluid contains cytokines, chemokines, immunoglobulins, and other immune mediators. Many studies have shown that the concentrations of these immune mediators change throughout the menstrual cycle, but the studies have often shown inconsistent results. Our understanding of immunological correlates of the menstrual cycle remains limited and could be improved by meta-analysis of the available evidence. METHODS: We performed a systematic review and meta-analysis of cervicovaginal immune mediator concentrations throughout the menstrual cycle using individual participant data. Study eligibility included strict definitions of the cycle phase (by progesterone or days since the last menstrual period) and no use of hormonal contraception or intrauterine devices. We performed random-effects meta-analyses using inverse-variance pooling to estimate concentration differences between the follicular and luteal phases. In addition, we performed a new laboratory study, measuring select immune mediators in cervicovaginal lavage samples. RESULTS: We screened 1570 abstracts and identified 71 eligible studies. We analyzed data from 31 studies, encompassing 39,589 concentration measurements of 77 immune mediators made on 2112 samples from 871 participants. Meta-analyses were performed on 53 immune mediators. Antibodies, CC-type chemokines, MMPs, IL-6, IL-16, IL-1RA, G-CSF, GNLY, and ICAM1 were lower in the luteal phase than the follicular phase. Only IL-1α, HBD-2, and HBD-3 were elevated in the luteal phase. There was minimal change between the phases for CXCL8, 9, and 10, interferons, TNF, SLPI, elafin, lysozyme, lactoferrin, and interleukins 1ß, 2, 10, 12, 13, and 17A. The GRADE strength of evidence was moderate to high for all immune mediators listed here. CONCLUSIONS: Despite the variability of cervicovaginal immune mediator measurements, our meta-analyses show clear and consistent changes during the menstrual cycle. Many immune mediators were lower in the luteal phase, including chemokines, antibodies, matrix metalloproteinases, and several interleukins. Only interleukin-1α and beta-defensins were higher in the luteal phase. These cyclical differences may have consequences for immunity, susceptibility to infection, and fertility. Our study emphasizes the need to control for the effect of the menstrual cycle on immune mediators in future studies.


Elafin , beta-Defensins , Female , Granulocyte Colony-Stimulating Factor , Humans , Immunoglobulins , Immunologic Factors , Interferons , Interleukin 1 Receptor Antagonist Protein , Interleukin-16 , Interleukin-1alpha , Interleukin-6 , Interleukins , Lactoferrin , Menstrual Cycle , Muramidase , Progesterone
16.
PLoS One ; 17(10): e0275794, 2022.
Article En | MEDLINE | ID: mdl-36215267

Multipurpose prevention technologies (MPTs), which prevent sexually transmitted infection(s) and unintended pregnancy, are highly desirable to women. In this randomized, placebo-controlled, phase I study, women used a placebo or tenofovir (TFV) and levonorgestrel (LNG) intravaginal ring (IVR), either continuously or cyclically (three, 28-day cycles with a 3 day interruption in between each cycle), for 90 days. Sixty-eight women were screened; 47 were randomized to 4 arms: TFV/LNG or placebo IVRs used continuously or cyclically (4:4:1:1). Safety was assessed by adverse events and changes from baseline in mucosal histology and immune mediators. TFV concentrations were evaluated in multiple compartments. LNG concentration was determined in serum. Modeled TFV pharmacodynamic antiviral activity was evaluated in vaginal and rectal fluids and cervicovaginal tissue ex vivo. LNG pharmacodynamics was assessed with cervical mucus quality and anovulation. All IVRs were safe with no serious adverse events nor significant changes in genital tract histology, immune cell density or secreted soluble proteins from baseline. Median vaginal fluid TFV concentrations were >500 ng/mg throughout 90d. TFV-diphosphate tissue concentrations exceeded 1,000 fmol/mg within 72hrs of IVR insertion. Mean serum LNG concentrations exceeded 200 pg/mL within 2h of TFV/LNG use, decreasing quickly after IVR removal. Vaginal fluid of women using TFV-containing IVRs had significantly greater inhibitory activity (87-98% versus 10% at baseline; p<0.01) against HIV replication in vitro. There was a >10-fold reduction in HIV p24 antigen production from ectocervical tissues after TFV/LNG exposure. TFV/LNG IVR users had significantly higher rates of anovulation, lower Insler scores and poorer/abnormal cervical mucus sperm penetration. Most TFV/LNG IVR users reported no change in menstrual cycles or fewer days of and/or lighter bleeding. All IVRs were safe. Active rings delivered high TFV concentrations locally. LNG caused changes in cervical mucus, sperm penetration, and ovulation compatible with contraceptive efficacy. Trial registration: ClinicalTrials.gov #NCT03279120.


Anovulation , Contraceptive Agents , Contraceptive Devices, Female , Levonorgestrel , Tenofovir , Anovulation/chemically induced , Antiviral Agents , Contraceptive Agents/therapeutic use , Diphosphates , Female , HIV Core Protein p24 , HIV Infections , Humans , Levonorgestrel/therapeutic use , Male , Semen , Tenofovir/therapeutic use
17.
Contemp Clin Trials ; 122: 106935, 2022 11.
Article En | MEDLINE | ID: mdl-36162740

Multipurpose prevention technology intravaginal rings (MPT IVRs) may offer a promising solution for addressing women's multiple sexual and reproductive health needs. We describe MPT IVR acceptability perspectives and examine user experiences of 25 cisgender women aged 18-34 years enrolled in a phase IIa randomized, partially blinded, placebo-controlled evaluation of tenofovir-based IVRs with and without contraceptive co-formulation. All took part in an individual, audio-recorded, semi-structured qualitative interview. A thematic analysis of transcribed interviews was completed in MaxQDA. Participants shared little to no knowledge of or experience with IVRs prior to joining the study. Four MPT IVR themes were identified: physical well-being, method reliability, personal management, and societal endorsement. Commonly cited of concern, but less described as being experienced, were physical discomforts (e.g., painful insertion/removal; inability to carry out daily activities/chores; foreign body sensation; expulsion; sexual interference, or debilitating side effects). Uncertainty regarding efficacy influenced perspectives about intended prevention benefits. Personal choices in managing reproduction and sexual behaviors had to be congruent with sociocultural values and norms for acceptance beyond the individual user level. Participants viewed broader community acceptance as likely to be mixed given community opposition to the use of modern family planning methods. They also shared concerns that IVR use could lead to infertility, especially among nulliparous women, or that it would encourage premarital sex or high-risk sexual behaviors among adolescent and young women. While a MPT IVR may not be suitable for all women, first-hand testimonials could help influence collective receptivity. Additional community acceptability research is needed. Clinical Trial Registration The study is registered at http://ClinicalTrials.gov under the identifier NCT03762382.


Contraceptive Devices, Female , HIV Infections , Adolescent , Female , Humans , Pregnancy , HIV Infections/prevention & control , Reproducibility of Results , Sexual Behavior , Tenofovir
18.
Sci Rep ; 12(1): 12040, 2022 07 14.
Article En | MEDLINE | ID: mdl-35835755

In a phase-IIa trial, we investigated the influence of 90 days continuous-delivery tenofovir (TFV) intravaginal rings (IVRs) with/without levonorgestrel (LNG) on the genital microbiota of Kenyan women. Eligible women (n = 27; 18-34 years; negative for HIV, sexually transmitted infections, and Amsel-bacterial vaginosis) were randomized 2:2:1 to use of IVRs containing TFV, TFV/LNG, or placebo. Using vaginal wall and IVR swabs at IVR insertion and removal, the genital microbial composition was determined using 16S rRNA gene sequencing. The presence of Candida spp. was determined using qPCR. The vaginal total bacterial burden appeared to decrease with TFV and TFV/LNG IVR use (log100.57 and log100.27 decrease respectively; p > 0.05). The TFV/LNG IVR was more 'stabilizing': 50% of the participants' microbiota community state types remained unchanged and 50% shifted towards higher Lactobacillus abundance. Specifically, TFV/LNG IVR use was accompanied by increased abundances of Lactobacillus gasseri/hominis/johnsonii/taiwanensis (16.3-fold) and L. fermentum/reuteri/vaginalis (7.0-fold; all p < 0.01). A significant shift in the overall microbial α-diversity or ß-diversity was not observed for either IVR, and IVR use did not influence Candida spp. prevalence. TFV/LNG and TFV IVRs did not adversely affect the genital microbiota and are safe to use. Our findings support further studies assessing their efficacy in preventing HIV/HSV-2 and unintended pregnancies.


HIV Infections , Microbiota , Administration, Intravaginal , Female , HIV Infections/drug therapy , HIV Infections/prevention & control , Humans , Kenya/epidemiology , Levonorgestrel/adverse effects , RNA, Ribosomal, 16S , Tenofovir/adverse effects , Vagina
19.
Sci Rep ; 12(1): 8970, 2022 05 27.
Article En | MEDLINE | ID: mdl-35624188

Vitrified, or "frozen", donor eggs can either be fertilized and cultured for fresh transfer (group 1), or fertilized and cryopreserved for transfer in a "frozen embryo transfer" cycle (group 2). This study compared the pregnancy rates between the two groups. Frozen donor egg cycles (N = 1213) were analyzed at the World Egg Bank. The outcome studied was clinical pregnancy rate. Cycles included only single embryo transfers (ET) without preimplantation genetic testing (PGT). A total of 600 cycles met the inclusion criteria. Group 1 included 409 cycles and group 2 had 191 cycles. There was no statistical significance in clinical pregnancy rate between the two groups (38.63% vs 32.46%, p = 0.14). Mean embryo age was higher in group 2 (5.1 vs. 5.4 days, p < 0.01). The compounding effect of vitrification when applied to two distinct stages (oocyte and embryo), has not been studied. When comparing the two groups, we found no difference in pregnancy rate. However, there was a trend towards fewer pregnancies in group 2. A larger study should be done to determine the validity of this result (Ramadan et al. in Fertil Steril, 2020).


Blastocyst , Cryopreservation , Female , Humans , Oocytes , Pregnancy , Pregnancy Rate , Vitrification
20.
AIDS Behav ; 26(9): 3099-3109, 2022 Sep.
Article En | MEDLINE | ID: mdl-35360893

For adolescent girls (AG) and young women (YW), adherence barriers may limit the effectiveness of daily oral HIV pre-exposure prophylaxis (PrEP). Due to its low-burden and long-lasting product attributes, PrEP implants could remove some of the critical adherence barriers of oral PrEP products for individuals at risk of HIV. To explore stated preferences for a long-acting PrEP implant, we conducted a quantitative survey and discrete choice experiment with AG (ages 15-17), YW (18-34), and female sex workers (FSW; ≥ 18) in Gauteng Province, South Africa. We completed 600 quantitative surveys across the three subgroups of women. Respondents stated preference for an implant that provided longer HIV protection (24 months versus 6 months) and required a single insertion. They stated that they preferred a biodegradable implant that could be removed within 1 month of insertion. Respondents had no preference for a particular insertion location. Overall, 78% of respondents said they would be likely (33%) or very likely (45%) to use a PrEP implant were one available, with the majority (82%) stating preference for a product that would provide dual protection against HIV and unintended pregnancies. To reduce their risk of HIV, AG, YW, and FSW in our survey reported a strong willingness to use long-acting, highly-effective, dissolvable PrEP implants.


RESUMEN: Las niñas adolescentes (NA) y mujeres jóvenes (MJ), pueden enfrentar barreras de adherencia que limitan la eficacia de la profilaxis oral previa a la exposición al VIH (PrEP). Ya que el implante de PrEP es un producto que requiere de poca intervención de la usuaria y es de larga duración, podría eliminar algunas de las barreras de adherencia más importantes en el uso de los productos orales de PrEP para aquellas personas en riesgo de infección de VIH. Para explorar las preferencias declaradas en cuanto al implante de PrEP de acción prolongada, llevamos a cabo una encuesta cuantitativa y un experimento de elección discreta (DCE) con NA (de 15 a 17 años), MJ (de 18 a 34 años) y mujeres trabajadoras del sexo (MTS; ≥ 18 años) en la provincia de Gauteng, Sudáfrica. Administramos 600 encuestas cuantitativas en los tres subgrupos de mujeres. Los resultados indican la preferencia por un implante que proporciona una protección contra el VIH más prolongada (24 meses a comparación con 6 meses) y que requiere de una única inserción. Las participantes afirmaron que prefieren un implante biodegradable que puede retirarse un mes después de su inserción. Las participantes no tenían preferencia por un sitio específico de inserción. En general, el 78% de las participantes indicaron que probablemente (33%) o muy probablemente (45%) utilizarían un implante de PrEP si estuviera disponible, y la mayoría (82%) manifestó su preferencia por un producto que proporcionaba una doble protección contra el VIH y el embarazo no deseado. Para reducir el riesgo de contraer el VIH, las NA, MJ y MTS participantes se mostraron muy dispuestas a utilizar implantes de PrEP de larga duración, altamente eficaces y disolubles.


Anti-HIV Agents , HIV Infections , Pre-Exposure Prophylaxis , Sex Workers , Adolescent , Anti-HIV Agents/therapeutic use , Female , HIV Infections/prevention & control , Humans , Pre-Exposure Prophylaxis/methods , Pregnancy , South Africa/epidemiology , Surveys and Questionnaires
...