Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 5 de 5
1.
Article En | MEDLINE | ID: mdl-38861324

BACKGROUND: Anemia is common among hemodialysis patients. Maintaining stable hemoglobin levels within predefined target levels can be challenging, particularly in patients with frequent hemoglobin fluctuations both above and below the desired targets. We conducted a multi-center, randomized, controlled trial comparing our anemia therapy assistance software against a standard population-based anemia treatment protocol. We hypothesized that personalized dosing of erythropoiesis stimulating agents (ESA) improves hemoglobin target attainment. METHODS: Ninety-six patients undergoing hemodialysis and receiving methoxy polyethylene glycol-epoetin beta were randomized 1:1 to the intervention group (personalized ESA dose recommendations computed by the software) or the standard of care group for twenty-six weeks. The therapy assistance software combined a physiology-based mathematical model and a model predictive controller designed to stabilize hemoglobin levels within a tight target range (10 to 11 g/dl). The primary outcome measure was the percentage of hemoglobin measurements within the target. Secondary outcome measures included measures of hemoglobin variability and ESA utilization. RESULTS: The intervention group showed an improved median percentage of hemoglobin measurements within target at 47% (IQR 39 to 58), with a 10 percentage points median difference between the two groups (95% CI: 3 to 16; P=0.008). The odds ratio of being within the hemoglobin target in the standard of care group compared to the group receiving the personalized ESA recommendations was 0.68 (95% CI: 0.51 to 0.92). The variability of hemoglobin levels decreased in the intervention group, with the percentage of patients experiencing fluctuating hemoglobin levels being 45% vs 82% in the standard of care group. ESA usage was reduced by about 25% in the intervention group. CONCLUSIONS: Our results demonstrated an improved hemoglobin target attainment and variability by employing personalized ESA recommendations using the physiology-based anemia therapy assistance software.

2.
Front Public Health ; 11: 1237512, 2023.
Article En | MEDLINE | ID: mdl-37790720

Background: Exhaled SARS-CoV-2 can be detected on face masks. We compared tests for SARS-CoV-2 RNA on worn face masks and matched saliva samples. Methods: We conducted this prospective, observational, case-control study between December 2021 and March 2022. Cases comprised 30 in-center hemodialysis patients with recent COVID-19 diagnosis. Controls comprised 13 hemodialysis patients and 25 clinic staff without COVID-19 during the study period and the past 2 months. Disposable 3-layer masks were collected after being worn for 4 hours together with concurrent saliva samples. ThermoFisher COVID-19 Combo Kit (A47814) was used for RT-PCR testing. Results: Mask and saliva testing specificities were 99% and 100%, respectively. Test sensitivity was 62% for masks, and 81% for saliva (p = 0.16). Median viral RNA shedding duration was 11 days and longer in immunocompromised versus non-immunocompromised patients (22 vs. 11 days, p = 0.06, log-rank test). Conclusion: While SARS-CoV-2 testing on worn masks appears to be less sensitive compared to saliva, it may be a preferred screening method for individuals who are mandated to wear masks yet averse to more invasive sampling. However, optimized RNA extraction methods and automated procedures are warranted to increase test sensitivity and scalability. We corroborated longer viral RNA shedding in immunocompromised patients.


COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19/prevention & control , Saliva , COVID-19 Testing , Masks , Case-Control Studies , Prospective Studies , RNA, Viral
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1410-1413, 2022 07.
Article En | MEDLINE | ID: mdl-36086026

The aim of this study was to measure intraperitoneal volume (IPV) and ultrafiltration volume (UFV) by monitoring the abdominal resistance using segmental bioimpedance analysis (SBIA, Hydra 4200). Twenty peritoneal dialysis (PD) patients were studied during a fill with 2 L of 2.5% glucose peritoneal dialysate solution. UFVDrain (g) was measured as weight difference between fill and drain dialysate volumes. Ultrafiltration volume (UFVSBIA; ml) and absorption volume were calculated from the IPV curve derived by SBIA. UFVSBIA correlated with UFVDrain ( ). This study may provide actionable clinical insights and help clinicians to better understand the function of the peritoneal membrane in individuals. Clinical Relevance-This technique may support personalized medicine by aiding the prescription of PD therapy on a patient-level.


Ascitic Fluid , Peritoneal Dialysis , Dialysis Solutions , Humans , Peritoneum , Ultrafiltration
4.
Blood Purif ; 50(4-5): 602-609, 2021.
Article En | MEDLINE | ID: mdl-33789266

BACKGROUND/OBJECTIVES: On March 22, 2020, a statewide stay-at-home order for nonessential tasks was implemented in New York State. We aimed to determine the impact of the lockdown on physical activity levels (PAL) in hemodialysis patients. METHODS: Starting in May 2018, we are conducting an observational study with a 1-year follow-up on PAL in patients from 4 hemodialysis clinics in New York City. Patients active in the study as of March 22, 2020, were included. PAL was defined by steps taken per day measured by a wrist-based monitoring device (Fitbit Charge 2). Average steps/day were calculated for January 1 to February 13, 2020, and then weekly from February 14 to June 30. RESULTS: 42 patients were included. Their mean age was 55 years, 79% were males, and 69% were African Americans. Between January 1 and February 13, 2020, patients took on average 5,963 (95% CI 4,909-7,017) steps/day. In the week prior to the mandated lockdown, when a national emergency was declared, and in the week of the shutdown, the average number of daily steps had decreased by 868 steps/day (95% CI 213-1,722) and 1,222 steps/day (95% CI 668-2300), respectively. Six patients were diagnosed with COVID-19 during the study period. Five of them exhibited significantly higher PAL in the 2 weeks prior to showing COVID-19 symptoms compared to COVID-19 negative patients. CONCLUSION: Lockdown measures were associated with a significant decrease in PAL in hemodialysis patients. Patients who contracted COVID-19 had higher PAL during the incubation period. Methods to increase PAL while allowing for social distancing should be explored and implemented.


COVID-19 , Exercise , Pandemics , Quarantine , Renal Dialysis , SARS-CoV-2 , Aged , COVID-19/prevention & control , Female , Fitness Trackers , Follow-Up Studies , Humans , Kidney Failure, Chronic/therapy , Male , Middle Aged , New York City , Physical Distancing , Prospective Studies , Socioeconomic Factors
5.
Kidney360 ; 2(1): 86-89, 2021 01 28.
Article En | MEDLINE | ID: mdl-35368814

Background: To date, it is unclear whether SARS-CoV-2 is present in spent dialysate from patients with COVID-19 on peritoneal dialysis (PD). Our aim was to assess the presence or absence of SARS-CoV-2 in spent dialysate from patients on chronic PD who had a confirmed diagnosis of COVID-19. Methods: Spent PD dialysate samples from patients on PD who were positive for COVID-19 were collected between March and August 2020. The multiplexed, real-time RT-PCR assay contained primer/probe sets specific to different SARS-CoV-2 genomic regions and to bacteriophage MS2 as an internal process control for nucleic acid extraction. Demographic and clinical data were obtained from patients' electronic health records. Results: A total of 26 spent PD dialysate samples were collected from 11 patients from ten dialysis centers. Spent PD dialysate samples were collected, on average, 25±13 days (median, 20; range, 10-45) after the onset of symptoms. The temporal distance of PD effluent collection relative to the closest positive nasal-swab RT-PCR result was 15±11 days (median, 14; range, 1-41). All 26 PD effluent samples tested negative at three SARS-CoV-2 genomic regions. Conclusions: Our findings indicate the absence of SARS-CoV-2 in spent PD dialysate collected at ≥10 days after the onset of COVID-19 symptoms. We cannot rule out the presence of SARS-CoV-2 in spent PD dialysate in the early stage of COVID-19.


COVID-19 , Peritoneal Dialysis , Dialysis Solutions , Humans , Peritoneal Dialysis/adverse effects , SARS-CoV-2/genetics
...