Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Neurobiol Aging ; 143: 30-40, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39208716

RESUMEN

Aim of the project was to evaluate the technical and clinical validity of plasma Lumipulse p-tau, Aß42 and Aß40 species and their correlation with CSF core Alzheimer's Disease (AD) markers; a method comparison with SIMOA was also performed. One-hundred-thirthy-three participants, namely 55 A+T+N+ AD, 28 Neurodegenerative disorders (NDD) and 50 controls were enrolled for the study. Lumipulse technical validity showed high stability for p-tau181, Aß42, and Aß40, with higher stability of p-tau to repeated freezing thaw cycles. p-tau181 levels detected by both techniques were higher in AD compared to both NDD/controls and exhibited a similar correlation with CSF p-tau levels, whereas Aß42 levels were slightly lower in AD with both methods. In the comparison between SIMOA and Lumipulse plasma markers, both techniques exhibited similar diagnostic accuracy for AD for p-tau181 (0.87; 95 %CI 0.81-0.94, vs 0.85; 95 %CI 0.78-0.93), whereas the best performance was reached by p-tau181/ Aß42 Lumipulse ratio (ROC AUC 0.915, 95 %CI 0.86-0.97). The study thus confirmed the construct validity of both Lumipulse and SIMOA techniques for the identification of CSF AD pattern in clinical settings.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Biomarcadores , Proteínas tau , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Humanos , Proteínas tau/sangre , Proteínas tau/líquido cefalorraquídeo , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Péptidos beta-Amiloides/sangre , Péptidos beta-Amiloides/líquido cefalorraquídeo , Femenino , Masculino , Anciano , Persona de Mediana Edad , Fragmentos de Péptidos/sangre , Fragmentos de Péptidos/líquido cefalorraquídeo , Anciano de 80 o más Años
2.
Int J Mol Sci ; 25(13)2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-39000564

RESUMEN

Alzheimer's disease (AD) and Frontotemporal lobar degeneration (FTLD) represent the most common forms of neurodegenerative dementias with a highly phenotypic variability. Herein, we investigated the role of genetic variants related to the immune system and inflammation as genetic modulators in AD and related dementias. In patients with sporadic AD/FTLD (n = 300) and GRN/C9orf72 mutation carriers (n = 80), we performed a targeted sequencing of 50 genes belonging to the immune system and inflammation, selected based on their high expression in brain regions and low tolerance to genetic variation. The linear regression analyses revealed two genetic variants: (i) the rs1049296 in the transferrin (TF) gene, shown to be significantly associated with age at onset in the sporadic AD group, anticipating the disease onset of 4 years for each SNP allele with respect to the wild-type allele, and (ii) the rs7550295 in the calsyntenin-1 (CLSTN1) gene, which was significantly associated with age at onset in the C9orf72 group, delaying the disease onset of 17 years in patients carrying the SNP allele. In conclusion, our data support the role of genetic variants in iron metabolism (TF) and in the modulation of the calcium signalling/axonal anterograde transport of vesicles (CLSTN1) as genetic modulators in AD and FTLD due to C9orf72 expansions.


Asunto(s)
Edad de Inicio , Enfermedad de Alzheimer , Proteína C9orf72 , Degeneración Lobar Frontotemporal , Humanos , Enfermedad de Alzheimer/genética , Proteína C9orf72/genética , Degeneración Lobar Frontotemporal/genética , Femenino , Masculino , Anciano , Persona de Mediana Edad , Expansión de las Repeticiones de ADN/genética , Anciano de 80 o más Años , Polimorfismo de Nucleótido Simple , Transferrina/genética , Transferrina/metabolismo , Predisposición Genética a la Enfermedad , Variación Genética
3.
medRxiv ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38746261

RESUMEN

Background: Plasma phosphorylated-tau217 (p-tau217) has been shown to be one of the most accurate diagnostic markers for Alzheimer's disease (AD). No studies have compared the clinical performance of p-tau217 as assessed by the fully automated Lumipulse and SIMOA ALZpath p-tau217. Aim: To evaluate the diagnostic accuracy of Lumipulse and SIMOA plasma p-tau217 assays for AD. Methods: The study included 392 participants, 162 with AD, 70 with other neurodegenerative diseases (NDD) with CSF biomarkers and 160 healthy controls. Plasma p-tau217 levels were measured using the Lumipulse and ALZpath SIMOA assays. The ability of p-tau217 assessed by both techniques to discriminate AD from NDD and controls was investigated using ROC analyses. Results: Both techniques showed high internal consistency of p-tau217 with similar correlation with CSF p-tau181 levels. In head-to-head comparison, Lumipulse and SIMOA showed similar diagnostic accuracy for differentiating AD from NDD (area under the curve [AUC] 0.952, 95%CI 0.927-0.978 vs 0.955, 95%CI 0.928-0.982, respectively) and HC (AUC 0.938, 95%CI 0.910-0.966 and 0.937, 95% CI0.907-0.967 for both assays). Conclusions: This study demonstrated the high precision and diagnostic accuracy of p-tau217 for the clinical diagnosis of Alzheimer's disease using either fully automated or semi-automated techniques.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38737930

RESUMEN

Indirect immunofluorescence on HEp-2 cell line (HEp-2-IIF) remains "gold standard" method for the detection of antinuclear antibodies (ANA). ANA is an operative definition, showing the possibility of autoantibodies (Aab) to bind nuclear, and cytoplasmic antigens. One of the major examples is represented by anti-mitochondrial antibodies (AMAs), which target proteins of the inner and outer mitochondrial membranes, located into the cytoplasm. The standard IIF on rat kidney/stomach/liver tissue sections, with the combined use of other commercial assays, may all be used in ordinary lab life to validate the AC-21 pattern on Hep-2 cells. The routine lab experience teaches that commercial kits cannot always be detected and define specific AMAs. In these cases the literature proposes the use of other homemade assays to detect AMAs as immunoprecipitation (IP) and Western blot (IP-WB). However, using IP or IP-WB is difficult to apply in a routine laboratory, because of numerous cases to process and the related troubles. Where find confirmation of the AC-21 pattern if line-immunoblot and other routine methods (ELISA, CLIA/FEIA assays) fail? We review AC-21 AMA-like sera from our patients (year 2022) and propose a revised diagnostic algorithm based on the combined use of IIF on Hep-2 cells, line immunoblot and IIF on rodent tissue as a third line method. We demonstrated that, particularly in cases where the second level test was unsuccessful, the application of IFI on rodent tissues became indispensable to verify the existence of AMAs.

5.
Biochem Med (Zagreb) ; 32(2): 020901, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35464745

RESUMEN

Introduction: Several laboratory tests are characteristically altered in Coronavirus Disease 2019 (COVID-19), but are not totally accurate in predicting the disease outcome. The long pentraxin 3 (PTX3) is quickly released directly at inflammation sites by many immune cell types. Previous studies have shown that PTX3 correlated with disease severity in various inflammatory conditions. Our study investigated the use of PTX3 as a potential marker of COVID-19 severity and compared its performance in detecting a more severe form of the disease with that of routine laboratory parameters. Materials and methods: Stored serum samples of RT-PCR confirmed COVID-19 cases that had been obtained at hospital admission were retrospectively analysed. Intensive care unit (ICU) stay was considered a surrogate endpoint of severe COVID-19. Pentraxin 3 was measured by a commercial enzyme-linked immunosorbent assay. Results: A total of 96 patients were recruited from May 1st, 2020 to June 30th, 2020; 75/96 were transferred to ICU. Pentraxin 3 was higher in ICU vs non-ICU patients (35.86 vs 10.61 ng/mL, P < 0.001). Univariate and multivariate logistic regression models demonstrated that the only significant laboratory predictor of ICU stay was PTX3 (OR: 1.68 (1.19-2.29), P = 0.003), after controlling for comorbidities. The Receiver Operator Characteristic curve analysis showed that PTX3 had a higher accuracy compared to C-reactive protein (CRP), lactate dehydrogenase (LD), ferritin in identifying ICU patients (AUC of PTX3 = 0.98; CRP = 0.66; LD = 0.70; ferritin = 0.67, P < 0.001). A cut-off of PTX3 > 18 ng/mL yielded a sensitivity of 96% and a specificity of 100% in identifying patients requiring ICU. Conclusion: High values of PTX3 predict a more severe COVID-19.


Asunto(s)
COVID-19 , Biomarcadores , Proteína C-Reactiva/metabolismo , COVID-19/diagnóstico , Ferritinas , Humanos , Curva ROC , Estudios Retrospectivos , Componente Amiloide P Sérico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA