Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
2.
Am Heart J ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39121917

RESUMEN

BACKGROUND: The optimal duration of dual antiplatelet therapy after currently available drug-eluting stent (DES) implantation to prevent stent thrombosis (ST) remains controversial. Delayed healing is frequently identified as a leading cause of ST in the early phase. However, a thorough pathological investigation into strut coverage after currently available DES implantation is lacking-a gap addressed in the current study. METHODS: From our autopsy registry of 199 stented lesions, 4,713 struts from 66 currently available DES-stented lesions with an implant duration ≤370 days were histologically evaluated. Endothelial coverage was defined as the presence of luminal endothelial cells overlying struts and an underlying smooth muscle cell layer. The stented lesions were classified into acute coronary syndrome (ACS) (n = 40) and chronic coronary syndrome (CCS) (n = 26) groups and were compared. Endothelial coverage predictors were identified through logistic analysis. RESULTS: Although ACS and CCS lesions presented comparable clinical characteristics, including age, sex, and cause of death, the latter exhibited a significantly higher prevalence of chronic kidney disease and hemodialysis than the former (33.3% vs. 65.2%; p = 0.02, 7.7% vs. 30.4%; p = 0.02). The poststent implant median duration was significantly shorter in ACS lesions than in CCS lesions (13 [IQR 5-26 days] vs. 40 [IQR 16-233 days]; p < 0.01). The endothelial coverage percentage was 3.5% at 30 days and 27.7% at 90 days after currently available DES implantation. Multivariable logistic regression analysis implicated implant duration of ≤90 days [odds ratio (OR), 0.009; 95% confidence interval (CI), 0.006-0.012; p < 0.01], superficial calcification (OR, 0.11; 95% CI, 0.07-0.17; p < 0.01), ACS culprit site (OR, 0.29; 95% CI, 0.09-0.94; p = 0.039), and circumferentially durable polymer-coated DES (OR, 0.32; 95% CI, 0.24-0.41; p < 0.01) as delayed endothelial coverage predictors. CONCLUSIONS: Endothelial coverage was limited at 90 days after currently available DES implantation, and the ACS culprit site and circumferentially durable polymer-coated DES were identified as independent predictors of delayed endothelial coverage. Our findings suggest the importance of underlying plaque morphology and stent technology for vessel healing after such implantation.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39034338

RESUMEN

The objective of the study is to investigate the safety, feasibility, and degradation profile of a novel Mg alloy-based bioresorbable coronary scaffold (JFK-PRODUCT BRS) with thin struts (110 µm). Polymer- or Mg alloy-based BRSs have not replaced nondegradable metal stents because of the higher prevalence of scaffold thrombosis and restenosis in clinical practice; these poor clinical outcomes were due to inadequate scaffold designs, including thick struts (more than 150 µm) and their inappropriate degradation processes. Fourteen healthy pigs received 17 JFK-PRODUCT BRSs in the coronary arteries and were sacrificed at 1, 6, 12, 18, and 26 months after implantation. Angiography, optical coherence tomography, microfocus X-ray computed tomography (µCT), scanning electron microscopy with energy-dispersive X-ray spectrometry (SEM-EDX), and histopathological evaluation were performed. The JFK-PRODUCT had a median percent late recoil of 11.28% at 1 month. The µCT observation confirmed that scaffold discontinuity reached 64.8% at 12 months with increased scaffold inner area thereafter, suggesting artery positive remodeling. The inflammation was mild, peaked at 18 months, and decreased thereafter. The SEM-EDX analysis demonstrated gradual degradation of the scaffold with formation of inorganic deposits, presumed to be calcium phosphates. It also revealed the disappearance of calcium phosphates at 26 months, achieving almost complete replacement of the scaffold by biocomponents. The current study demonstrated the safety and feasibility of JFK-PRODUCT with a lower acute recoil rate despite its thin struts. The scaffolds were almost completely disappeared at 26 months after implantation.

4.
Cardiovasc Pathol ; 71: 107647, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38649122

RESUMEN

BACKGROUND: IgG4-related disease (IgG4-RD) is a recently recognized fibro-inflammatory disorder that can affect almost any organ. IgG4-RD has also been reported in coronary arteries as periarteritis. IgG4-related coronary periarteritis may cause coronary artery aneurysms, and IgG4-related coronary artery aneurysms (IGCAs) are life-threatening. We describe a case of a patient with IGCA that highlights the usefulness and limitations of various IGCA evaluation modalities and provides insight into disease pathophysiology. CASE SUMMARY: A 60-year-old man with IgG4-RD diagnosed 2 years before and with IGCA at the proximal right coronary artery (RCA) on coronary angiography (CAG) 9 months prior to admission to the hospital presented with acute coronary syndrome. Emergent CAG revealed the rapid progression of IGCA at the RCA, an obstruction of the diagonal branch, and stenosis of the left anterior descending artery (LAD) and the high lateral branch (HL). The patient underwent percutaneous coronary intervention for the diagonal branch. The RCA aneurysm was resected and bypassed with a saphenous vein graft (SVG); coronary bypass grafting (left internal mammary artery to LAD and SVG to HL) was performed. Pathological findings showed inflammatory cell infiltration and disruption of the elastic plate. CONCLUSION: IGCAs require careful follow-up with computed tomography scans for early detection of aneurysmal enlargement.


Asunto(s)
Aneurisma Coronario , Angiografía Coronaria , Puente de Arteria Coronaria , Progresión de la Enfermedad , Enfermedad Relacionada con Inmunoglobulina G4 , Humanos , Masculino , Aneurisma Coronario/cirugía , Aneurisma Coronario/inmunología , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/patología , Persona de Mediana Edad , Enfermedad Relacionada con Inmunoglobulina G4/complicaciones , Enfermedad Relacionada con Inmunoglobulina G4/inmunología , Enfermedad Relacionada con Inmunoglobulina G4/cirugía , Enfermedad Relacionada con Inmunoglobulina G4/diagnóstico , Enfermedad Relacionada con Inmunoglobulina G4/patología , Vasos Coronarios/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/inmunología , Resultado del Tratamiento , Intervención Coronaria Percutánea , Inmunoglobulina G/sangre
5.
J Vasc Surg Cases Innov Tech ; 10(3): 101447, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38510091

RESUMEN

A fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage, with the remaining surface predominantly covered by fibrin. Notably, there was no evidence of restenosis or aneurysmal change.

6.
EuroIntervention ; 20(6): e389-e398, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506736

RESUMEN

BACKGROUND: Drug-coated balloons (DCBs) are important treatment options for coronary artery disease; however, randomised controlled trials comparing various DCB technologies are sparse, and further investigations are needed. AIMS: This preclinical study aimed to histologically and biologically compare the drug effects and safety of a low-dose paclitaxel-coated DCB (PCB; AGENT), a regular-dose PCB (SeQuent Please NEO) and a sirolimus-coated DCB (SCB; MagicTouch). METHODS: The DCBs were inflated in the healthy iliac arteries of 18 rabbits, which were euthanised after 28 days. The treated iliac arteries and distal skeletal muscles were histopathologically evaluated, and drug concentrations were measured. RESULTS: In the histopathological evaluation, the medial smooth muscle cell loss score regarding depth, an indicator of drug efficacy, was significantly higher with AGENT and SeQuent Please NEO than with MagicTouch (4.0 [3.6-4.0] vs 3.7 [3.7-4.0] vs 2.2 [2.0-2.4]), with significant differences in comparisons between AGENT and MagicTouch (p<0.01) and between SeQuent Please NEO and MagicTouch (p<0.01). AGENT and SeQuent Please NEO showed comparable drug concentrations in the treated artery (p=0.61). In contrast, the drug concentrations in distal skeletal muscles were the highest for MagicTouch, followed by SeQuent Please NEO and AGENT (28.07 [13.19-52.46] ng/mg vs 0.66 [0.22-3.76] ng/mg vs 0.25 [0.04-3.23] ng/mg, respectively). CONCLUSIONS: This study demonstrated that PCBs might have higher efficacy and lower drug concentrations in distal skeletal muscles than the MagicTouch SCB. The efficacy of the AGENT low-dose PCB and the SeQuent Please NEO regular-dose PCB was comparable.


Asunto(s)
Paclitaxel , Sirolimus , Animales , Conejos , Paclitaxel/administración & dosificación , Sirolimus/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/métodos , Materiales Biocompatibles Revestidos , Arteria Ilíaca/efectos de los fármacos , Arteria Ilíaca/patología , Masculino , Modelos Animales de Enfermedad , Fármacos Cardiovasculares/administración & dosificación , Fármacos Cardiovasculares/farmacocinética
7.
JACC Asia ; 4(1): 1-9, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38222261

RESUMEN

Transcatheter structural heart interventions have drastically evolved over the past 2 decades. However, most catheterization procedures require the deployment of devices in the body; therefore, the adhesion of thrombi to those devices is a major problem, resulting in the requirement of a period of postprocedural antithrombotic regimen. However, in recent years, bleeding associated with these antithrombotic therapies has also become a major concern, attracting the attention of investigators. This is complicated by the fact that patients at high thrombotic risk are also at high bleeding risk, making the issue of administrating antithrombotic therapy challenging. The objective of this review was to identify the important issues and summarize the current status of postoperative antithrombotic therapy and assessment of the bleeding risk following transcatheter structural heart interventions such as transcatheter aortic valve replacement, transcatheter edge-to-edge repair, and transcatheter left atrial appendage occlusion.

9.
JACC Asia ; 3(6): 925-934, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38155789

RESUMEN

Background: There are limited data on the impact of intracardiac echocardiography (ICE)-guided transcatheter aortic valve replacement (TAVR) on the new permanent pacemaker implantation (PPMI) rate. Objectives: This study investigated the feasibility and outcome of transjugular ICE (TJ-ICE) -guided TAVR, by visualizing the relationship between the membranous septum (MS) and the transcatheter aortic valve (TAV). Methods: Among patients with severe aortic stenosis who underwent TAVR between February 2017 and June 2020, this study enrolled a total of 163 patients with TJ-ICE-guided TAVR. MS length was measured by ICE. The primary endpoint of this study was the incidence of new PPMI at 30 days. Results: The mean age of the patients in this study was 84.9 ± 4.6 years, and 71.2% of the patients were female. Device success was 96.3% with TJ-ICE guidance. A TJ-ICE-related complication occurred in 1 case (0.6%). The median length of the MS was 5.8 mm (IQR: 5.0-6.9 mm). Excellent intraobserver (intraclass correlation coefficient [ICC]: 0.94; 95% CI:0.79-0.98; P < 0.001) and interobserver (ICC: 0.93; 95% CI: -0.05 to 0.98; P < 0.001) agreements were shown. The new PPMI rate was 6.7% at 30 days without a significant difference between balloon-expandable valves and self-expandable valves (3.4% vs 8.7%; P = 0.226). Patients with a TAV implantation depth less than MS length had a significantly lower incidence of new PPMI compared with patients with a TAV implantation depth greater than MS length (2.1% vs 13.4%; P = 0.005), regardless of baseline right bundle branch block presence (6.7% vs 66.7%; P = 0.004) or absence (1.2% vs 8.2%; P = 0.041). Conclusions: TJ-ICE-guided TAVR demonstrated remarkable feasibility and safety. The TJ-ICE-guided final TAV position had a significant impact on the new PPMI rate. (Tokai Valve Registry; UMIN000036671).

10.
Cardiol Young ; 33(12): 2670-2672, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37822181

RESUMEN

Post-operative pulmonary venous stenosis is a poor prognostic factor in single-ventricle haemodynamics. Implantation of a drug-eluting stent is a therapeutic option. However, due to their small size, they inevitably become inadequate as the patient grows. We present the first case, to the best of our knowledge, of the replacement of a small-diameter stent with a large-diameter stent during Fontan surgery.


Asunto(s)
Stents Liberadores de Fármacos , Procedimiento de Fontan , Venas Pulmonares , Humanos , Procedimiento de Fontan/efectos adversos , Stents , Venas Pulmonares/cirugía , Arteria Pulmonar/cirugía , Resultado del Tratamiento
12.
Eur Heart J Case Rep ; 7(8): ytad353, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37559783

RESUMEN

Background: Several side effects have been reported after mRNA COVID-19 vaccinations. Nonetheless, the risk of pulmonary hypertension (PH) is rarely reported. Most cases with acute PH following vaccination were due to macropulmonary embolism secondary to deep vein thrombosis. However, acute PH due to microthrombus formation after COVID-19 vaccination has not been reported before, although a microthrombus has been considered to lead to the dysfunction of multiple organs, particularly in patients infected with COVID-19. Case summary: A 63-year-old woman without any past medical history presented to our hospital with facial and bilateral pedal oedema and progressive dyspnoea on exertion. Her symptoms began the day after her second COVID-19 vaccination and developed gradually, which prompted her to seek consultation in our hospital 6 weeks later. An echocardiogram revealed substantially elevated right heart pressure, and cardiac catheterization revealed high pulmonary artery pressure (mean PAP, 30 mmHg). Contrast-enhanced computed tomography and venous echography revealed no apparent thrombus, and ventilation/perfusion (V/Q) scintigraphy revealed no V/Q mismatch. However, elevated D-dimer indicated the presence of a coagulation-fibrinolysis system in her body; thus, heparin therapy was initiated intravenously on Day 3 for 4 days, followed by direct oral anticoagulants ended on Day 16. Her symptoms substantially improved as her D-dimer level decreased, and a follow-up cardiac catheterization on Day 14 revealed a decline in mean PAP (15 mmHg). Discussion: Our case suggests that the presence of acute PH is likely due to microangiopathy. Further studies are required to reveal the relationship between immune responses and microthrombus formation after COVID-19 vaccination.

14.
Eur J Vasc Endovasc Surg ; 66(5): 722-729, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37516380

RESUMEN

OBJECTIVE: Poor below knee (BTK) runoff is a predictor of stent failure after endovascular femoropopliteal artery treatment; however, lack of pathological evaluation has prevented characterisation of stent failure. The study aimed to investigate the impact of poor BTK runoff and the antithrombotic effect of the polymer of fluoropolymer coated paclitaxel eluting stents (FP-PESs) in a healthy swine femoropopliteal artery model. METHODS: FP-PESs and bare metal stents (BMSs) and FP-PES and polymer free paclitaxel coated stents (PF-PCSs) were implanted in the bilateral femoral arteries of healthy swine (n = 6, respectively) following coil embolisation in both tibial arteries to induce poor BTK runoff. Histological assessment and intravascular imaging device evaluation were performed at one month. The Japanese Association for Laboratory Animal Science approved the study protocol (reference number: IVT22-90). RESULTS: Optical coherence tomography showed significantly lower percent area stenosis in FP-PES compared with BMS (37.3%, [interquartile range (IQR), 25.6 - 54.3] % vs. 92.5% [IQR, 75.5 - 96.1] %, respectively, p = .031), and PF-PCS (8.3% [IQR, 4.5 - 27.0] % vs. 31.2% [IQR, 23.3 - 52.2] %, respectively, p = .031). Histopathological evaluation demonstrated that thin fibrin attachment without re-stenosis was the most dominant neointimal tissue characteristic in FP-PES. On the other hand, neointimal tissue characteristics with significant restenosis of BMS and PF-PCS were mainly organising or organised thrombus. CONCLUSION: Organising and or organised thrombus attachment due to poor BTK runoff was the main cause of in stent restenosis of the swine femoral artery. FP-PES demonstrated the least percent area stenosis, suggesting the importance of the antithrombotic effect of polymer.


Asunto(s)
Stents Liberadores de Fármacos , Trombosis , Porcinos , Animales , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Polímeros de Fluorocarbono , Fibrinolíticos , Constricción Patológica , Stents , Polímeros , Paclitaxel , Neointima , Trombosis/etiología , Resultado del Tratamiento
16.
J Endovasc Ther ; : 15266028231161215, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36951275

RESUMEN

BACKGROUND: A recent meta-analysis of randomized control trials demonstrated a significantly higher risk of major amputation in patients treated with drug-coated balloons (DCBs) compared with standard treatment, especially in high-dose paclitaxel-coated DCBs. Distal particulate embolization after DCB use was considered a potential cause of the higher incidence of major amputation. The current study aimed to histologically and biologically compare biologic drug effect and distal particulate embolization in 3 DCBs (a high-dose paclitaxel-coated DCB [IN.PACT Admiral] and 2 low-dose paclitaxel-coated DCBs [Ranger and Lutonix]). METHODS AND RESULTS: The DCBs were inflated in the healthy descending aortas of 18 rabbits, followed by euthanasia 28 days after the procedure. The treated descending aorta and distal skeletal muscles were histopathologically evaluated, and paclitaxel concentrations were measured. The paclitaxel concentration of the treated lesion was highest for Ranger, followed by IN.PACT and Lutonix (Ranger vs IN.PACT vs Lutonix: 1089 [745-2170] pmol/mg vs 638 [160-2075] pmol/mg vs 25 [10-304] pmol/mg, respectively; p<0.0001). In the histopathological evaluation, the angle of severe medial smooth muscle cell loss was largest for Ranger followed by IN.PACT and Lutonix (12.8 [8.0-20.4] degree vs 1.4 [1.2-5.2] degree vs 0.8 [0.5-2.5] degree, respectively), with significant differences for Ranger vs IN.PACT (p=0.007) and Ranger vs Lutonix (p=0.002). However, paclitaxel concentrations of distal skeletal muscles were lowest for Lutonix, followed by Ranger and IN.PACT (12 [1-58] pmol/mg vs 15 [13-21] pmol/mg vs 42 [19-108] pmol/mg, respectively, p<0.0001). The numbers of arteries with downstream DCB effects were highest for IN.PACT, followed by Ranger and Lutonix (Ranger vs IN.PACT vs Lutonix, 3 [3-4] vs 4 [3-7] vs 2 [1-2], respectively), which was consistent with the measured tissue paclitaxel concentrations. CONCLUSION: These findings suggest that Ranger demonstrates the strongest paclitaxel effect, as well as the second-best effect regarding distal particulate embolization, making it a good treatment option for patients with peripheral artery disease among the 3 DCBs evaluated in the current study. Further clinical head-to-head comparisons with larger numbers of patients are needed to explore which DCB is the most effective and safe treatment option.Clinical Impact:The findings of the current preclinical study suggests that Ranger demonstrates the strongest paclitaxel effect, as well as the second-best effect regarding distal particulate embolization making it a good treatment for patients with intermittent claudication and chronic limb-threatening ischemia.

18.
Cardiovasc Interv Ther ; 38(2): 223-230, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36609899

RESUMEN

BACKGROUND: Excimer laser is used to treat coronary artery disease, especially in case of lesions with thrombus and in-stent restenosis (ISR). However, there are no in vivo preclinical studies that have evaluated the pathological reactions of the vessel wall after excimer laser ablation. METHODS: Bare-metal stents were placed in the external iliac arteries of six healthy rabbits. Twenty-eight days later, excimer laser ablation was performed with low-power (45 (fluency)/25 (rate)) in one side, and high-power (60/40) in the opposite side, followed by optical coherence tomography (OCT) evaluation. Rabbits were sacrificed 15 min after the procedure, and histological assessment was performed. RESULTS: Morphometry analysis of OCT showed similar stent and lumen size between low-power and high-power group. Histological evaluation suggested endothelial cell loss, fibrin deposition, and tissue loss. The low-power group showed significantly less pathological changes compared with the high-power group: angle of endothelial cell loss, 32.4° vs. 191.7° (interquartile range, 8.8°-131.7° vs. 125.7°-279.5°; p < 0.01); fibrin deposition, 1.1° vs. 59.6° (0.0°-70.4° vs. 31.4°-178.4°; p = 0.03); and tissue loss 0.0° vs. 18.2° (0.0°-8.7° vs. 0.0°-42.7°; p = 0.03). CONCLUSIONS: The pathological changes in neointima were more prominent after high-power excimer laser ablation than after low-power excimer laser. To improve safety in clinical practice, understanding the pathological changes of tissues after excimer laser in lesions with ISR is essential.


Asunto(s)
Angioplastia por Láser , Reestenosis Coronaria , Animales , Humanos , Conejos , Neointima/patología , Láseres de Excímeros/uso terapéutico , Arteria Ilíaca/cirugía , Angiografía Coronaria , Stents/efectos adversos , Fibrina , Tomografía de Coherencia Óptica/métodos , Reestenosis Coronaria/terapia , Resultado del Tratamiento
19.
JCI Insight ; 8(5)2023 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-36719758

RESUMEN

Vascular calcification (VC) is concomitant with atherosclerosis, yet it remains uncertain why rupture-prone high-risk plaques do not typically show extensive calcification. Intraplaque hemorrhage (IPH) deposits erythrocyte-derived cholesterol, enlarging the necrotic core and promoting high-risk plaque development. Pro-atherogenic CD163+ alternative macrophages engulf hemoglobin:haptoglobin (HH) complexes at IPH sites. However, their role in VC has never been examined to our knowledge. Here we show, in human arteries, the distribution of CD163+ macrophages correlated inversely with VC. In vitro experiments using vascular smooth muscle cells (VSMCs) cultured with HH-exposed human macrophage - M(Hb) - supernatant reduced calcification, while arteries from ApoE-/- CD163-/- mice showed greater VC. M(Hb) supernatant-exposed VSMCs showed activated NF-κB, while blocking NF-κB attenuated the anticalcific effect of M(Hb) on VSMCs. CD163+ macrophages altered VC through NF-κB-induced transcription of hyaluronan synthase (HAS), an enzyme that catalyzes the formation of the extracellular matrix glycosaminoglycan, hyaluronan, within VSMCs. M(Hb) supernatants enhanced HAS production in VSMCs, while knocking down HAS attenuated its anticalcific effect. NF-κB blockade in ApoE-/- mice reduced hyaluronan and increased VC. In human arteries, hyaluronan and HAS were increased in areas of CD163+ macrophage presence. Our findings highlight an important mechanism by which CD163+ macrophages inhibit VC through NF-κB-induced HAS augmentation and thus promote the high-risk plaque development.


Asunto(s)
Aterosclerosis , Placa Aterosclerótica , Calcificación Vascular , Ratones , Humanos , Animales , FN-kappa B , Ácido Hialurónico , Ratones Noqueados para ApoE , Macrófagos , Aterosclerosis/complicaciones , Apolipoproteínas E/genética
20.
JACC Adv ; 2(9): 100656, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38938733

RESUMEN

Background: The prevalence and degree of lower extremity artery disease in hemodialysis (HD) patients is higher than in the general population. However, the pathological features have not yet been evaluated. Objectives: The aim of the study was: 1) to compare lesion characteristics of lower extremity artery disease in HD vs non-HD patients; and 2) to determine factors associated with severe medial calcification. Methods: Seventy-seven lower limb arteries were assessed from 36 patients (median age 77 years; 23 men; 21 HD and 15 non-HD) who underwent autopsy or lower limb amputation. Arteries were serially cut at 3- to 4-mm intervals creating 2,319 histological sections. Morphometric analysis and calcification measurements were performed using ZEN software. Calcification with a circumferential angle (arc) ≥180° was defined as severe calcification. Multivariable logistic regression was used to identify risk factors for severe medial calcification. Results: The degree of the medial calcification arc was significantly higher in the HD group compared to the non-HD group (P < 0.0001). In the multivariable analysis, HD was associated with severe medial calcification in below-the-knee lesions (OR: 17.1; P = 0.02). The degree of intimal calcification in above-the-knee lesions was also significantly higher in HD patients with a higher prevalence of advanced atherosclerotic plaque (P = 0.02). The prevalence of severe bone formation was more common in the HD patients (P = 0.01). Conclusions: Hemodialysis patients demonstrated a higher degree of medial and intimal calcification compared with non-HD patients. The difference was more prominent in the medial calcification of below-the-knee lesions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA