Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 108
1.
J Neuroimaging ; 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38590085

BACKGROUND AND PURPOSE: We aimed to test whether synthetic T1-weighted imaging derived from a post-contrast Quantitative Transient-state Imaging (QTI) acquisition enabled revealing pathological contrast enhancement in intracranial lesions. METHODS: The analysis included 141 patients who underwent a 3 Tesla-MRI brain exam with intravenous contrast media administration, with the post-contrast acquisition protocol comprising a three-dimensional fast spoiled gradient echo (FSPGR) sequence and a QTI acquisition. Synthetic T1-weighted images were generated from QTI-derived quantitative maps of relaxation times and proton density. Two neuroradiologists assessed synthetic and conventional post-contrast T1-weighted images for the presence and pattern of pathological contrast enhancement in intracranial lesions. Enhancement volumes were quantitatively compared. RESULTS: Using conventional imaging as a reference, synthetic T1-weighted imaging was 93% sensitive in revealing the presence of contrast enhancing lesions. The agreement for the presence/absence of contrast enhancement was almost perfect both between readers (k = 1 for both conventional and synthetic imaging) and between sequences (k = 0.98 for both readers). In 91% of lesions, synthetic T1-weighted imaging showed the same pattern of contrast enhancement visible in conventional imaging. Differences in enhancement pattern in the remaining lesions can be due to the lower spatial resolution and the longer acquisition delay from contrast media administration of QTI compared to FSPGR. Overall, enhancement volumes appeared larger in synthetic imaging. CONCLUSIONS: QTI-derived post-contrast synthetic T1-weighted imaging captures pathological contrast enhancement in most intracranial enhancing lesions. Further comparative studies employing quantitative imaging with higher spatial resolution is needed to support our data and explore possible future applications in clinical trials.

2.
Front Neurol ; 15: 1362704, 2024.
Article En | MEDLINE | ID: mdl-38419703

Chemotherapy and radiotherapy are widely used in the treatment of central nervous system tumors and acute lymphocytic leukemia even in the pediatric population. However, such treatments run the risk of a broad spectrum of cognitive and neurological deficits. Even though the correlation with cognitive decline is still not clear, neuroradiological defects linked to white matter injury and vasculopathies may be identified. Thanks to the use of 7T MRI it is possible to better define the vascular pattern of the brain lesions with the added advantage of identifying their characteristics and anatomical localization, which, however, are not evident with a conventional brain scan. Moreover, the use of Quantitative Susceptibility Mapping (QSM) makes it possible to discriminate between calcium deposits on vessels (chemo-radiation-induced) and hemoglobin deposition in radio-induced cavernomas, speculating, as a result, about the pathophysiology of iatrogenic brain damage. We describe the case of a 9 year-old boy with a T-type acute lymphoid leukemia who had previously been treated with polychemotherapy and high-dose RT. To better define the child's neuroradiological pattern, 7T MRI and QSM were performed in addition to conventional imaging examinations. Our case report suggests the potential usefulness of a QSM study to distinguish radio-induced vascular malformations from mineralizing microangiopathy.

3.
NMR Biomed ; 37(6): e5114, 2024 Jun.
Article En | MEDLINE | ID: mdl-38390667

A quantitative biomarker for myelination, such as myelin water fraction (MWF), would boost the understanding of normative and pathological neurodevelopment, improving patients' diagnosis and follow-up. We quantified the fraction of a rapidly relaxing pool identified as MW using multicomponent three-dimensional (3D) magnetic resonance fingerprinting (MRF) to evaluate white matter (WM) maturation in typically developing (TD) children and alterations in leukodystrophies (LDs). We acquired DTI and 3D MRF-based R1, R2 and MWF data of 15 TD children and 17 LD patients (9 months-12.5 years old) at 1.5 T. We computed normative maturation curves in corpus callosum and corona radiata and performed WM tract profile analysis, comparing MWF with R1, R2 and fractional anisotropy (FA). Normative maturation curves demonstrated a steep increase for all tissue parameters in the first 3 years of age, followed by slower growth for MWF while R1, R2R2 and FA reached a plateau. Unlike FA, MWF values were similar for regions of interest (ROIs) with different degrees of axonal packing, suggesting independence from fiber bundle macro-organization and higher myelin specificity. Tract profile analysis indicated a specific spatial pattern of myelination in the major fiber bundles, consistent across subjects. LD were better distinguished from TD by MWF rather than FA, showing reduced MWF with respect to age-matched controls in both ROI-based and tract analysis. In conclusion, MRF-based MWF provides myelin-specific WM maturation curves and is sensitive to alteration due to LDs, suggesting its potential as a biomarker for WM disorders. As MRF allows fast simultaneous acquisition of relaxometry and MWF, it can represent a valuable diagnostic tool to study and follow up developmental WM disorders in children.


Myelin Sheath , White Matter , Humans , White Matter/diagnostic imaging , Myelin Sheath/metabolism , Child , Male , Female , Child, Preschool , Infant , Diffusion Tensor Imaging , Water/chemistry , Body Water , Magnetic Resonance Imaging
4.
NMR Biomed ; 37(1): e5039, 2024 Jan.
Article En | MEDLINE | ID: mdl-37714527

In this study, we aimed to develop a fast and robust high-resolution technique for clinically feasible electrical properties tomography based on water content maps (wEPT) using Quantitative Transient-state Imaging (QTI), a multiparametric transient state-based method that is similar to MR fingerprinting. Compared with the original wEPT implementation based on standard spin-echo acquisition, QTI provides robust electrical properties quantification towards B1 + inhomogeneities and full quantitative relaxometry data. To validate the proposed approach, 3D QTI data of 12 healthy volunteers were acquired on a 1.5 T scanner. QTI-provided T1 maps were used to compute water content maps of the tissues using an empirical relationship based on literature ex-vivo measurements. Assuming that electrical properties are modulated mainly by tissue water content, the water content maps were used to derive electrical conductivity and relative permittivity maps. The proposed technique was compared with a conventional phase-only Helmholtz EPT (HH-EPT) acquisition both within whole white matter, gray matter, and cerebrospinal fluid masks, and within different white and gray matter subregions. In addition, QTI-based wEPT was retrospectively applied to four multiple sclerosis adolescent and adult patients, compared with conventional contrast-weighted imaging in terms of lesion delineation, and quantitatively assessed by measuring the variation of electrical properties in lesions. Results obtained with the proposed approach agreed well with theoretical predictions and previous in vivo findings in both white and gray matter. The reconstructed maps showed greater anatomical detail and lower variability compared with standard phase-only HH-EPT. The technique can potentially improve delineation of pathology when compared with conventional contrast-weighted imaging and was able to detect significant variations in lesions with respect to normal-appearing tissues. In conclusion, QTI can reliably measure conductivity and relative permittivity of brain tissues within a short scan time, opening the way to the study of electric properties in clinical settings.


Magnetic Resonance Imaging , Water , Adult , Humans , Adolescent , Retrospective Studies , Magnetic Resonance Imaging/methods , Tomography , Tomography, X-Ray Computed , Electric Conductivity , Phantoms, Imaging , Image Processing, Computer-Assisted/methods , Brain
5.
Eur Radiol Exp ; 7(1): 71, 2023 11 16.
Article En | MEDLINE | ID: mdl-37968363

BACKGROUND: The brainstem contains grey matter nuclei and white matter tracts to be identified in clinical practice. The small size and the low contrast among them make their in vivo visualisation challenging using conventional magnetic resonance imaging (MRI) sequences at high magnetic field strengths. Combining higher spatial resolution, signal- and contrast-to-noise ratio and sensitivity to magnetic susceptibility (χ), susceptibility-weighted 7-T imaging could improve the assessment of brainstem anatomy. METHODS: We acquired high-resolution 7-T MRI of the brainstem in a 46-year-old female healthy volunteer (using a three-dimensional multi-echo gradient-recalled-echo sequence; spatial resolution 0.3 × 0.3 × 1.2 mm3) and in a brainstem sample from a 48-year-old female body donor that was sectioned and stained. Images were visually assessed; nuclei and tracts were labelled and named according to the official nomenclature. RESULTS: This in vivo imaging revealed structures usually evaluated through light microscopy, such as the accessory olivary nuclei, oculomotor nucleus and the medial longitudinal fasciculus. Some fibre tracts, such as the medial lemniscus, were visible for most of their course. Overall, in in vivo acquisitions, χ and frequency maps performed better than T2*-weighted imaging and allowed for the evaluation of a greater number of anatomical structures. All the structures identified in vivo were confirmed by the ex vivo imaging and histology. CONCLUSIONS: The use of multi-echo GRE sequences at 7 T allowed the visualisation of brainstem structures that are not visible in detail at conventional magnetic field and opens new perspectives in the diagnostic and therapeutical approach to brain disorders. RELEVANCE STATEMENT: In vivo MR imaging at UHF provides detailed anatomy of CNS substructures comparable to that obtained with histology. Anatomical details are fundamentals for diagnostic purposes but also to plan a direct targeting for a minimally invasive brain stimulation or ablation. KEY POINTS: • The in vivo brainstem anatomy was explored with ultrahigh field MRI (7 T). • In vivo T2*-weighted magnitude, χ, and frequency images revealed many brainstem structures. • Ex vivo imaging and histology confirmed all the structures identified in vivo. • χ and frequency imaging revealed more brainstem structures than magnitude imaging.


Brain Stem , Magnetic Resonance Imaging , Female , Humans , Middle Aged , Brain Stem/diagnostic imaging , Brain Stem/anatomy & histology , Magnetic Resonance Imaging/methods
6.
Tomography ; 9(5): 1723-1733, 2023 09 11.
Article En | MEDLINE | ID: mdl-37736990

Synthetic MR Imaging allows for the reconstruction of different image contrasts from a single acquisition, reducing scan times. Commercial products that implement synthetic MRI are used in research. They rely on vendor-specific acquisitions and do not include the possibility of using custom multiparametric imaging techniques. We introduce PySynthMRI, an open-source tool with a user-friendly interface that uses a set of input images to generate synthetic images with diverse radiological contrasts by varying representative parameters of the desired target sequence, including the echo time, repetition time and inversion time(s). PySynthMRI is written in Python 3.6, and it can be executed under Linux, Windows, or MacOS as a python script or an executable. The tool is free and open source and is developed while taking into consideration the possibility of software customization by the end user. PySynthMRI generates synthetic images by calculating the pixelwise signal intensity as a function of a set of input images (e.g., T1 and T2 maps) and simulated scanner parameters chosen by the user via a graphical interface. The distribution provides a set of default synthetic contrasts, including T1w gradient echo, T2w spin echo, FLAIR and Double Inversion Recovery. The synthetic images can be exported in DICOM or NiFTI format. PySynthMRI allows for the fast synthetization of differently weighted MR images based on quantitative maps. Specialists can use the provided signal models to retrospectively generate contrasts and add custom ones. The modular architecture of the tool can be exploited to add new features without impacting the codebase.


Radiology , Retrospective Studies , Contrast Media , Software
7.
Neuroimage Clin ; 40: 103509, 2023.
Article En | MEDLINE | ID: mdl-37717382

OBJECTIVES: The disruption of the blood-brain barrier (BBB) is a key and early feature in the pathogenesis of demyelinating multiple sclerosis (MS) lesions and has been neuropathologically demonstrated in both active and chronic plaques. The local overt BBB disruption in acute demyelinating lesions is captured as signal hyperintensity in post-contrast T1-weighted images because of the contrast-related shortening of the T1 relaxation time. On the contrary, the subtle BBB disruption in chronic lesions is not visible at conventional radiological evaluation but it might be of clinical relevance. Indeed, persistent, subtle BBB leakage might be linked to low-grade inflammation and plaque evolution. Here we hypothesised that 3D Quantitative Transient-state Imaging (QTI) was able to reveal and measure T1 shortening (ΔT1) reflecting small amounts of contrast media leakage in apparently non-enhancing lesions (ANELs). MATERIALS AND METHODS: Thirty-four patients with relapsing remitting MS were included in the study. All patients underwent a 3 T MRI exam of the brain including conventional sequences and QTI acquisitions (1.1 mm isotropic voxel) performed both before and after contrast media administration. For each patient, a ΔT1 map was obtained via voxel-wise subtraction of pre- and post- contrast QTI-derived T1 maps. ΔT1 values measured in ANELs were compared with those recorded in enhancing lesions and in the normal appearing white matter. A reference distribution of ΔT1 in the white matter was obtained from datasets acquired in 10 non-MS patients with unrevealing MR imaging. RESULTS: Mean ΔT1 in ANELs (57.45 ± 48.27 ms) was significantly lower than in enhancing lesions (297.71 ± 177.52 ms; p < 0. 0001) and higher than in the normal appearing white matter (36.57 ± 10.53 ms; p < 0.005). Fifty-two percent of ANELs exhibited ΔT1 higher than those observed in the white matter of non-MS patients. CONCLUSIONS: QTI-derived quantitative ΔT1 mapping enabled to measure contrast-related T1 shortening in ANELs. ANELs exhibiting ΔT1 values that deviate from the reference distribution in non-MS patients may indicate persistent, subtle, BBB disruption. Access to this information may be proved useful to better characterise pathology and objectively monitor disease activity and response to therapy.


Multiple Sclerosis, Relapsing-Remitting , Multiple Sclerosis , Humans , Blood-Brain Barrier/diagnostic imaging , Blood-Brain Barrier/metabolism , Multiple Sclerosis/pathology , Contrast Media/metabolism , Brain/pathology , Multiple Sclerosis, Relapsing-Remitting/pathology , Magnetic Resonance Imaging/methods
8.
Phys Med ; 112: 102610, 2023 Aug.
Article En | MEDLINE | ID: mdl-37331082

PURPOSE: The use of topological metrics to derive quantitative descriptors from structural connectomes is receiving increasing attention but deserves specific studies to investigate their reproducibility and variability in the clinical context. This work exploits the harmonization of diffusion-weighted acquisition for neuroimaging data performed by the Italian Neuroscience and Neurorehabilitation Network initiative to obtain normative values of topological metrics and to investigate their reproducibility and variability across centers. METHODS: Different topological metrics, at global and local level, were calculated on multishell diffusion-weighted data acquired at high-field (e.g. 3 T) Magnetic Resonance Imaging scanners in 13 different centers, following the harmonization of the acquisition protocol, on young and healthy adults. A "traveling brains" dataset acquired on a subgroup of subjects at 3 different centers was also analyzed as reference data. All data were processed following a common processing pipeline that includes data pre-processing, tractography, generation of structural connectomes and calculation of graph-based metrics. The results were evaluated both with statistical analysis of variability and consistency among sites with the traveling brains range. In addition, inter-site reproducibility was assessed in terms of intra-class correlation variability. RESULTS: The results show an inter-center and inter-subject variability of <10%, except for "clustering coefficient" (variability of 30%). Statistical analysis identifies significant differences among sites, as expected given the wide range of scanners' hardware. CONCLUSIONS: The results show low variability of connectivity topological metrics across sites running a harmonised protocol.


Connectome , Adult , Humans , Connectome/methods , Reproducibility of Results , Benchmarking , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging
9.
Phys Med ; 110: 102577, 2023 Jun.
Article En | MEDLINE | ID: mdl-37126963

Initiatives for the collection of harmonized MRI datasets are growing continuously, opening questions on the reliability of results obtained in multi-site contexts. Here we present the assessment of the brain anatomical variability of MRI-derived measurements obtained from T1-weighted images, acquired according to the Standard Operating Procedures, promoted by the RIN-Neuroimaging Network. A multicentric dataset composed of 77 brain T1w acquisitions of young healthy volunteers (mean age = 29.7 ± 5.0 years), collected in 15 sites with MRI scanners of three different vendors, was considered. Parallelly, a dataset of 7 "traveling" subjects, each undergoing three acquisitions with scanners from different vendors, was also used. Intra-site, intra-vendor, and inter-site variabilities were evaluated in terms of the percentage standard deviation of volumetric and cortical thickness measures. Image quality metrics such as contrast-to-noise and signal-to-noise ratio in gray and white matter were also assessed for all sites and vendors. The results showed a measured global variability that ranges from 11% to 19% for subcortical volumes and from 3% to 10% for cortical thicknesses. Univariate distributions of the normalized volumes of subcortical regions, as well as the distributions of the thickness of cortical parcels appeared to be significantly different among sites in 8 subcortical (out of 17) and 21 cortical (out of 68) regions of i nterest in the multicentric study. The Bland-Altman analysis on "traveling" brain measurements did not detect systematic scanner biases even though a multivariate classification approach was able to classify the scanner vendor from brain measures with an accuracy of 0.60 ± 0.14 (chance level 0.33).


Brain , Magnetic Resonance Imaging , Humans , Young Adult , Adult , Reproducibility of Results , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging , Signal-To-Noise Ratio
10.
J Neurosci ; 43(21): 3825-3837, 2023 05 24.
Article En | MEDLINE | ID: mdl-37037605

Behavioral studies suggest that motion perception is rudimentary at birth and matures steadily over the first few years. We demonstrated previously that the major cortical associative areas serving motion processing, like middle temporal complex (MT+), visual cortex area 6 (V6), and PIVC in adults, show selective responses to coherent flow in 8-week-old infants. Here, we study the BOLD response to the same motion stimuli in 5-week-old infants (four females and four males) and compare the maturation between these two ages. The results show that MT+ and PIVC areas show a similar motion response at 5 and 8 weeks, whereas response in the V6 shows a reduced BOLD response to motion at 5 weeks, and cuneus associative areas are not identifiable at this young age. In infants and in adults, primary visual cortex (V1) does not show a selectivity for coherent motion but shows very fast development between 5 and 8 weeks of age in response to the appearance of motion stimuli. Resting-state correlations demonstrate adult-like functional connectivity between the motion-selective associative areas but not between primary cortex and temporo-occipital and posterior-insular cortices. The results are consistent with a differential developmental trajectory of motion area respect to other occipital regions, probably reflecting also a different development trajectory of the central and peripheral visual field.SIGNIFICANCE STATEMENT How the cortical visual areas attain the specialization that we observed in human adults in the first few months of life is unknown. However, this knowledge is crucial to understanding the consequence of perinatal brain damage and its outcome. Here, we show that motion selective areas are already functioning well in 5-week-old infants with greater responses for detecting coherent motion over random motion, suggesting that very little experience is needed to attain motion selectivity.


Brain Injuries , Motion Perception , Motor Cortex , Adult , Infant, Newborn , Female , Male , Pregnancy , Humans , Infant , Knowledge , Motion , Photic Stimulation , Magnetic Resonance Imaging
11.
Phys Med ; 110: 102590, 2023 Jun.
Article En | MEDLINE | ID: mdl-37116389

PURPOSE: To develop methods for quality assurance of quantitative susceptibility mapping (QSM) using MRI at different magnetic field strengths, and scanners, using different MR-sequence protocols, and post-processing pipelines. METHODS: We built a custom phantom based on iron in two forms: homogeneous susceptibility ('free iron') and with fine-scaled variations in susceptibility ('clustered iron') at different iron concentrations. The phantom was measured at 3.0 T (two scanners), 7.0 T and 9.4 T using multi-echo, gradient echo acquisition sequences. A digital phantom analogue to the iron-phantom, tailored to obtain similar results as in experimentation was developed, with similar geometry and susceptibility values. Morphology enabled dipole inversion was applied to the phase images to obtain QSM for experimental and simulated data using the MEDI + 0 approach for background regularization. RESULTS: Across all scanners, QSM-values showed a linear increase with iron concentrations. The QSM-relaxivity was 0.231 ± 0.047 ppm/mM for free and 0.054 ± 0.013 ppm/mM for clustered iron, with adjusted determination coefficients (DoC) ≥ 0.87. Similarly, the simulations yielded linear increases (DoC ≥ 0.99). In both the experimental and digital phantoms, the estimated molar susceptibility was lower with clustered iron, because clustering led to highly localized field effects. CONCLUSION: Our iron phantom can be used to evaluate the capability of QSM to detect local variations in susceptibility across different field strengths, when using different MR-sequence protocols. The devised simulation method captures the effect of iron clustering in QSM as seen experimentally and could be used in the future to optimize QSM processing pipelines and achieve higher accuracy for local field effects, as also seen in Alzheimer's beta-amyloid plaques.


Iron , Magnetic Resonance Imaging , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Computer Simulation , Brain , Image Processing, Computer-Assisted/methods , Brain Mapping/methods
12.
Cereb Cortex ; 33(3): 729-739, 2023 01 05.
Article En | MEDLINE | ID: mdl-35271703

Relaxation times and morphological information are fundamental magnetic resonance imaging-derived metrics of the human brain that reflect the status of the underlying tissue. Magnetic resonance fingerprinting (MRF) enables simultaneous acquisition of T1 and T2 maps inherently aligned to the anatomy, allowing whole-brain relaxometry and morphometry in a single scan. In this study, we revealed the feasibility of 3D MRF for simultaneous brain structure-wise morphometry and relaxometry. Comprehensive test-retest scan analyses using five 1.5-T and three 3.0-T systems from a single vendor including different scanner types across 3 institutions demonstrated that 3D MRF-derived morphological information and relaxation times are highly repeatable at both 1.5 T and 3.0 T. Regional cortical thickness and subcortical volume values showed high agreement and low bias across different field strengths. The ability to acquire a set of regional T1, T2, thickness, and volume measurements of neuroanatomical structures with high repeatability and reproducibility facilitates the ability of longitudinal multicenter imaging studies to quantitatively monitor changes associated with underlying pathologies, disease progression, and treatments.


Brain , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods
13.
Phys Med ; 104: 93-100, 2022 Dec.
Article En | MEDLINE | ID: mdl-36379160

PURPOSE: Generating big-data is becoming imperative with the advent of machine learning. RIN-Neuroimaging Network addresses this need by developing harmonized protocols for multisite studies to identify quantitative MRI (qMRI) biomarkers for neurological diseases. In this context, image quality control (QC) is essential. Here, we present methods and results of how the RIN performs intra- and inter-site reproducibility of geometrical and image contrast parameters, demonstrating the relevance of such QC practice. METHODS: American College of Radiology (ACR) large and small phantoms were selected. Eighteen sites were equipped with a 3T scanner that differed by vendor, hardware/software versions, and receiver coils. The standard ACR protocol was optimized (in-plane voxel, post-processing filters, receiver bandwidth) and repeated monthly. Uniformity, ghosting, geometric accuracy, ellipse's ratio, slice thickness, and high-contrast detectability tests were performed using an automatic QC script. RESULTS: Measures were mostly within the ACR tolerance ranges for both T1- and T2-weighted acquisitions, for all scanners, regardless of vendor, coil, and signal transmission chain type. All measurements showed good reproducibility over time. Uniformity and slice thickness failed at some sites. Scanners that upgraded the signal transmission chain showed a decrease in geometric distortion along the slice encoding direction. Inter-vendor differences were observed in uniformity and geometric measurements along the slice encoding direction (i.e. ellipse's ratio). CONCLUSIONS: Use of the ACR phantoms highlighted issues that triggered interventions to correct performance at some sites and to improve the longitudinal stability of the scanners. This is relevant for establishing precision levels for future multisite studies of qMRI biomarkers.


Data Accuracy , Humans , Reproducibility of Results
14.
Phys Med ; 103: 37-45, 2022 Nov.
Article En | MEDLINE | ID: mdl-36219961

Quantitative Susceptibility Mapping (QSM) is an MRI-based technique allowing the non-invasive quantification of iron content and myelination in the brain. The RIN - Neuroimaging Network established an optimized and harmonized protocol for QSM across ten sites with 3T MRI systems from three different vendors to enable multicentric studies. The assessment of the reproducibility of this protocol is crucial to establish susceptibility as a quantitative biomarker. In this work, we evaluated cross-vendor reproducibility in a group of six traveling brains. Then, we recruited fifty-one volunteers and measured the variability of QSM values in a cohort of healthy subjects scanned at different sites, simulating a multicentric study. Both voxelwise and Region of Interest (ROI)-based analysis on cortical and subcortical gray matter were performed. The traveling brain study yielded high structural similarity (∼0.8) and excellent reproducibility comparing maps acquired on scanners from two different vendors. Depending on the ROI, we reported a quantification error ranging from 0.001 to 0.017 ppm for the traveling brains. In the cohort of fifty-one healthy subjects scanned at nine different sites, the ROI-dependent variability of susceptibility values, of the order of 0.005-0.025 ppm, was comparable to the result of the traveling brain experiment. The harmonized QSM protocol of the RIN - Neuroimaging Network provides a reliable quantification of susceptibility in both cortical and subcortical gray matter regions and it is ready for multicentric and longitudinal clinical studies in neurological and pychiatric diseases.


Brain , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Gray Matter/diagnostic imaging , Brain Mapping/methods
15.
Radiol Med ; 127(9): 950-959, 2022 Sep.
Article En | MEDLINE | ID: mdl-35984559

PURPOSE: To compare the characteristics detected by 7Tesla (7 T) MR and the histological composition of ex-vivo specimens from lesions diagnosed at preoperative CT scan as Pancreatic Ductal Adenocarcinoma (PDAC). MATERIALS AND METHODS: Ten pancreatic specimens were examined. The 7 T imaging protocol included both morphologic and quantitative sequences; the latter was acquired by conventional methods and a novel multiparametric method, the magnetic resonance fingerprinting (MRF) sequence. Two radiologists reviewed the images to: (1) evaluate the quality of the morphological and quantitative sequences by assigning an "image consistency score" on a 4-point scale; (2) identify the lesion, recording its characteristics; (3) perform the quantitative analysis on "target lesion" and "non target tissue". Finally, the specimen was analysed by two pathologists. RESULTS: Seven out of 10 lesions were PDAC, 2/10 were biliary carcinomas, whereas one lesion was an ampullary adenocarcinoma. The quality of the morphological sequences was judged "excellent". The "image consistency score" for the conventional quantitative sequences and MRF were 2.8 ± 0.42 and 2.9 ± 0.57; the "overall MR examination score" was 3.5 ± 0.53. A statistical correlation was found between the relaxation time values of conventional and MRF T1-weighted sequences (p < 0.0001), as well as between conventional and MRF fat- and water-fraction maps (p < 0.05). The "target lesion" and "non target tissue" relaxation time values were statistically different according to conventional T1-, T2-weighted, and MRF T1-weighted sequences. CONCLUSIONS: Conventional T1-, T2-weighted sequences and MRF derived relaxometries may be useful in differentiating between tumour and non-target pancreatic tissue. Moreover, the MRF sequence can be used to obtain reliable relaxation time data.


Adenocarcinoma , Magnetic Resonance Imaging , Adenocarcinoma/diagnostic imaging , Correlation of Data , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Prospective Studies , Water
16.
Neuroimage ; 260: 119454, 2022 10 15.
Article En | MEDLINE | ID: mdl-35810938

Idiopathic rapid eye movement (REM) sleep behavior disorder (iRBD) is a prodromal stage of α-synucleinopathies, such as Parkinson's disease (PD), which are characterized by the loss of dopaminergic neurons in substantia nigra, associated with abnormal iron load. The assessment of presymptomatic biomarkers predicting the onset of neurodegenerative disorders is critical for monitoring early signs, screening patients for neuroprotective clinical trials and understanding the causal relationship between iron accumulation processes and disease development. Here, we used Quantitative Susceptibility Mapping (QSM) and 7T MRI to quantify iron deposition in Nigrosome 1 (N1) in early PD (ePD) patients, iRBD patients and healthy controls and investigated group differences and correlation with disease progression. We evaluated the radiological appearance of N1 and analyzed its iron content in 35 ePD, 30 iRBD patients and 14 healthy controls via T2*-weighted sequences and susceptibility (χ) maps. N1 regions of interest (ROIs) were manually drawn on control subjects and warped onto a study-specific template to obtain probabilistic N1 ROIs. For each subject the N1 with the highest mean χ was considered for statistical analysis. The appearance of N1 was rated pathological in 45% of iRBD patients. ePD patients showed increased N1 χ compared to iRBD patients and HC but no correlation with disease duration, indicating that iron load remains stable during the early stages of disease progression. Although no difference was reported in iron content between iRBD and HC, N1 χ in the iRBD group increases as the disease evolves. QSM can reveal temporal changes in N1 iron content and its quantification may represent a valuable presymptomatic biomarker to assess neurodegeneration in the prodromal stages of PD.


Iron Overload , Parkinson Disease , REM Sleep Behavior Disorder , Synucleinopathies , Biomarkers , Disease Progression , Humans , Iron , Iron Overload/diagnostic imaging , Parkinson Disease/diagnostic imaging , Parkinson Disease/pathology , Prodromal Symptoms , REM Sleep Behavior Disorder/diagnostic imaging , REM Sleep Behavior Disorder/pathology
17.
Front Neurol ; 13: 855125, 2022.
Article En | MEDLINE | ID: mdl-35493836

Neuroimaging studies often lack reproducibility, one of the cardinal features of the scientific method. Multisite collaboration initiatives increase sample size and limit methodological flexibility, therefore providing the foundation for increased statistical power and generalizable results. However, multisite collaborative initiatives are inherently limited by hardware, software, and pulse and sequence design heterogeneities of both clinical and preclinical MRI scanners and the lack of benchmark for acquisition protocols, data analysis, and data sharing. We present the overarching vision that yielded to the constitution of RIN-Neuroimaging Network, a national consortium dedicated to identifying disease and subject-specific in-vivo neuroimaging biomarkers of diverse neurological and neuropsychiatric conditions. This ambitious goal needs efforts toward increasing the diagnostic and prognostic power of advanced MRI data. To this aim, 23 Italian Scientific Institutes of Hospitalization and Care (IRCCS), with technological and clinical specialization in the neurological and neuroimaging field, have gathered together. Each IRCCS is equipped with high- or ultra-high field MRI scanners (i.e., ≥3T) for clinical or preclinical research or has established expertise in MRI data analysis and infrastructure. The actions of this Network were defined across several work packages (WP). A clinical work package (WP1) defined the guidelines for a minimum standard clinical qualitative MRI assessment for the main neurological diseases. Two neuroimaging technical work packages (WP2 and WP3, for clinical and preclinical scanners) established Standard Operative Procedures for quality controls on phantoms as well as advanced harmonized quantitative MRI protocols for studying the brain of healthy human participants and wild type mice. Under FAIR principles, a web-based e-infrastructure to store and share data across sites was also implemented (WP4). Finally, the RIN translated all these efforts into a large-scale multimodal data collection in patients and animal models with dementia (i.e., case study). The RIN-Neuroimaging Network can maximize the impact of public investments in research and clinical practice acquiring data across institutes and pathologies with high-quality and highly-consistent acquisition protocols, optimizing the analysis pipeline and data sharing procedures.

18.
Elife ; 112022 04 06.
Article En | MEDLINE | ID: mdl-35384840

While there is evidence that the visual cortex retains a potential for plasticity in adulthood, less is known about the subcortical stages of visual processing. Here, we asked whether short-term ocular dominance plasticity affects the human visual thalamus. We addressed this question in normally sighted adult humans, using ultra-high field (7T) magnetic resonance imaging combined with the paradigm of short-term monocular deprivation. With this approach, we previously demonstrated transient shifts of perceptual eye dominance and ocular dominance in visual cortex (Binda et al., 2018). Here, we report evidence for short-term plasticity in the ventral division of the pulvinar (vPulv), where the deprived eye representation was enhanced over the nondeprived eye. This vPulv plasticity was similar as previously seen in visual cortex and it was correlated with the ocular dominance shift measured behaviorally. In contrast, there was no effect of monocular deprivation in two adjacent thalamic regions: dorsal pulvinar and Lateral Geniculate Nucleus. We conclude that the visual thalamus retains potential for short-term plasticity in adulthood; the plasticity effect differs across thalamic subregions, possibly reflecting differences in their corticofugal connectivity.


Vision, Monocular , Visual Cortex , Adult , Dominance, Ocular , Geniculate Bodies , Humans , Neuronal Plasticity , Sensory Deprivation , Thalamus
19.
Neuroimage Clin ; 34: 102989, 2022.
Article En | MEDLINE | ID: mdl-35303599

The non-invasive quantification of iron stores via Quantitative Susceptibility Mapping (QSM) could play an important role in the diagnosis and the differential diagnosis of atypical Parkinsonisms. However, the susceptibility (χ) values measured via QSM depend on echo time (TE). This effect relates to the microstructural organization within the voxel, whose composition can be altered by the disease. Moreover, pathological iron deposition in a brain area may not be spatially uniform, and conventional Region of Interest (ROI)-based analysis may fail in detecting alterations. Therefore, in this work we evaluated the impact of echo time on the diagnostic accuracy of QSM on a population of patients with Multiple System Atrophy (MSA) of either Parkinsonian (MSAp) or cerebellar (MSAc) phenotypes. In addition, we tested the potential of histogram analysis to improve QSM classification accuracy. We enrolled 32 patients (19 MSAp and 13 MSAc) and 16 healthy controls, who underwent a 7T MRI session including a gradient-recalled multi-echo sequence for χ mapping. Nine histogram features were extracted from the χ maps computed for each TE in atlas-based ROIs covering deep brain nuclei, and compared among groups. Alterations of susceptibility distribution were found in the Putamen, Substantia Nigra, Globus Pallidus and Caudate Nucleus for MSAp and in the Substantia Nigra and Dentate Nucleus for MSAc. Increased iron deposition was observed in a larger number of ROIs for the two shortest TEs and the standard deviation, the 75th and the 90th percentile were the most informative features yielding excellent diagnostic accuracy with area under the ROC curve > 0.9. In conclusion, short TEs may enhance QSM diagnostic performances, as they can capture variations in rapidly-decaying contributions of high χ sources. The analysis of histogram features allowed to reveal fine heterogeneities in the spatial distribution of susceptibility alteration, otherwise undetected by a simple evaluation of ROI χ mean values.


Multiple System Atrophy , Brain/diagnostic imaging , Brain Mapping , Humans , Iron/analysis , Magnetic Resonance Imaging , Multiple System Atrophy/diagnostic imaging
20.
Med Image Anal ; 77: 102387, 2022 04.
Article En | MEDLINE | ID: mdl-35180675

Voluntary and involuntary patient motion is a major problem for data quality in clinical routine of Magnetic Resonance Imaging (MRI). It has been thoroughly investigated and, yet it still remains unresolved. In quantitative MRI, motion artifacts impair the entire temporal evolution of the magnetization and cause errors in parameter estimation. Here, we present a novel strategy based on residual learning for retrospective motion correction in fast 3D whole-brain multiparametric MRI. We propose a 3D multiscale convolutional neural network (CNN) that learns the non-linear relationship between the motion-affected quantitative parameter maps and the residual error to their motion-free reference. For supervised model training, despite limited data availability, we propose a physics-informed simulation to generate self-contained paired datasets from a priori motion-free data. We evaluate motion-correction performance of the proposed method for the example of 3D Quantitative Transient-state Imaging at 1.5T and 3T. We show the robustness of the motion correction for various motion regimes and demonstrate the generalization capabilities of the residual CNN in terms of real-motion in vivo data of healthy volunteers and clinical patient cases, including pediatric and adult patients with large brain lesions. Our study demonstrates that the proposed motion correction outperforms current state of the art, reliably providing a high, clinically relevant image quality for mild to pronounced patient movements. This has important implications in clinical setups where large amounts of motion affected data must be discarded as they are rendered diagnostically unusable.


Multiparametric Magnetic Resonance Imaging , Adult , Artifacts , Child , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Motion , Retrospective Studies
...