Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Phys Med ; 121: 103346, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38608421

RESUMEN

Partial breast irradiation for the treatment of early-stage breast cancer patients can be performed by means of Intra Operative electron Radiation Therapy (IOeRT). One of the main limitations of this technique is the absence of a treatment planning system (TPS) that could greatly help in ensuring a proper coverage of the target volume during irradiation. An IOeRT TPS has been developed using a fast Monte Carlo (MC) and an ultrasound imaging system to provide the best irradiation strategy (electron beam energy, applicator position and bevel angle) and to facilitate the optimisation of dose prescription and delivery to the target volume while maximising the organs at risk sparing. The study has been performed in silico, exploiting MC simulations of a breast cancer treatment. Ultrasound-based input has been used to compute the absorbed dose maps in different irradiation strategies and a quantitative comparison between the different options was carried out using Dose Volume Histograms. The system was capable of exploring different beam energies and applicator positions in few minutes, identifying the best strategy with an overall computation time that was found to be completely compatible with clinical implementation. The systematic uncertainty related to tissue deformation during treatment delivery with respect to imaging acquisition was taken into account. The potential and feasibility of a GPU based full MC TPS implementation of IOeRT breast cancer treatments has been demonstrated in-silico. This long awaited tool will greatly improve the treatment safety and efficacy, overcoming the limits identified within the clinical trials carried out so far.


Asunto(s)
Neoplasias de la Mama , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/diagnóstico por imagen , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Electrones/uso terapéutico , Factores de Tiempo , Gráficos por Computador , Femenino , Órganos en Riesgo/efectos de la radiación
2.
Phys Med Biol ; 68(4)2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36356308

RESUMEN

Objective. The Monte Carlo simulation software is a valuable tool in radiation therapy, in particular to achieve the needed accuracy in the dose evaluation for the treatment plans optimisation. The current challenge in this field is the time reduction to open the way to many clinical applications for which the computational time is an issue. In this manuscript we present an innovative GPU-accelerated Monte Carlo software for dose valuation in electron and photon based radiotherapy, developed as an update of the FRED (Fast paRticle thErapy Dose evaluator) software.Approach. The code transports particles through a 3D voxel grid, while scoring their energy deposition along their trajectory. The models of electromagnetic interactions in the energy region between 1 MeV-1 GeV available in literature have been implemented to efficiently run on GPUs, allowing to combine a fast tracking while keeping high accuracy in dose assessment. The FRED software has been bench-marked against state-of-art full MC (FLUKA, GEANT4) in the realm of two different radiotherapy applications: Intra-Operative Radio Therapy and Very High Electron Energy radiotherapy applications.Results. The single pencil beam dose-depth profiles in water as well as the dose map computed on non-homogeneous phantom agree with full-MCs at 2% level, observing a gain in processing time from 200 to 5000.Significance. Such performance allows for computing a plan with electron beams in few minutes with an accuracy of ∼%, demonstrating the FRED potential to be adopted for fast plan re-calculation in photon or electron radiotherapy applications.


Asunto(s)
Electrones , Programas Informáticos , Método de Montecarlo , Simulación por Computador , Fotones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Fantasmas de Imagen , Algoritmos
3.
Sci Rep ; 10(1): 20735, 2020 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-33244102

RESUMEN

The high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient. The DP capability to detect inter-fractional changes is demonstrated by comparing the obtained fragment emission maps in different fractions of the treatments enrolled in the first ever clinical trial of such a monitoring system, performed at CNAO. The case of a CNAO patient that underwent a significant morphological change is presented in detail, focusing on the implications that can be drawn for the achievable inter-fractional monitoring DP sensitivity in real clinical conditions. The results have been cross-checked against a simulation study.


Asunto(s)
Carbono/uso terapéutico , Iones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Ensayos Clínicos como Asunto , Humanos , Radiometría/métodos
4.
Phys Med ; 72: 96-102, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32247965

RESUMEN

This paper provides a first insight of the potential of the ß- Radio Guided Surgery (ß--RGS) in a complex surgical environment like the abdomen, where multiple sources of background concur to the signal at the tumor site. This case is well reproduced by ex-vivo samples of 90Y-marked Gastro-Entero-Pancreatic Neuroendocrine Tumors (GEP NET) in the bowel. These specimens indeed include at least three wide independent sources of background associated to three anatomical districts (mesentery, intestine, mucose). The study is based on the analysis of 37 lesions found on 5 samples belonging to 5 different patients. We show that the use of electrons, a short range particle, instead of γ particles, allows to limit counts read on a lesion to the sum of the tumor signal plus the background generated by the sole hosting district.The background on adjacent districts in the same specimen/patient is found to differ up to a factor 4, showing how the specificity and sensitivity of the ß--RGS technique can be fully exploited only upon a correct measurement of the contributing background. This locality has been used to set a site-specific cut-off algorithm to discriminate tumor and healthy tissue with a specificity of 100% and a sensitivity, on this test data sample, close to 100%. Factors influencing the sensitivity are also discussed. One of the specimens set allowed us evaluate the volume of the lesions, thus concluding that the probe was able to detect lesions as small as 0.04 mL in that particular case.


Asunto(s)
Partículas beta/uso terapéutico , Tumores Neuroendocrinos/cirugía , Cirugía Asistida por Computador/métodos , Algoritmos , Humanos
5.
Phys Med ; 67: 85-90, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31704391

RESUMEN

PURPOSE: Radio Guided Surgery (RGS) is a technique that helps the surgeon to achieve an as complete as possible tumor resection, thanks to the intraoperative detection of particles emitted by a radio tracer that bounds to tumoral cells. In the last years, a novel approach to this technique has been proposed that, exploiting ß- emitting radio tracers, overtakes some limitations of established γ-RGS. In this context, a first prototype of an intraoperative ß particle detector, based on a high light yield and low density organic scintillator, has been developed and characterised on pure ß- emitters, like 90Y. The demonstrated very high efficiency to ß- particles, together with the remarkable transparency to photons, suggested the possibility to use this detector also with ß+ emitting sources, that have plenty of applications in nuclear medicine. In this paper, we present upgrades and optimisations performed to the detector to reveal such particles. METHODS: Laboratory measurement have been performed on liquid Ga68 source, and were used to validate and tune a Monte Carlo simulation. RESULTS: The upgraded detector has an ~80% efficiency to electrons above ~110keV, reaching a plateau value of ~95%. At the same time, the probe is substantially transparent to photons below ~200keV, reaching a plateau value of ~3%. CONCLUSIONS: The new prototype seems to have promising characteristics to perform RGS also with ß+ emitting isotopes.


Asunto(s)
Partículas beta , Electrones , Medicina Nuclear , Conteo por Cintilación , Cirugía Asistida por Computador
6.
Phys Med ; 64: 45-53, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31515035

RESUMEN

Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and 12C ions are already used for irradiation in clinical routine, while new ions like 4He and 16O are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak - BP), during the treatment. To ensure correct 'in-treatment' dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an 16O beam during target irradiation can be considered as candidates for 16O beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an 16O beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90° and 60° with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.


Asunto(s)
Radioterapia de Iones Pesados , Oxígeno/uso terapéutico , Polimetil Metacrilato , Incertidumbre
7.
Phys Med ; 65: 84-93, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31437603

RESUMEN

Particle therapy (PT) can exploit heavy ions (such as He, C or O) to enhance the treatment efficacy, profiting from the increased Relative Biological Effectiveness and Oxygen Enhancement Ratio of these projectiles with respect to proton beams. To maximise the gain in tumor control probability a precise online monitoring of the dose release is needed, avoiding unnecessary large safety margins surroundings the tumor volume accounting for possible patient mispositioning or morphological changes with respect to the initial CT scan. The Dose Profiler (DP) detector, presented in this manuscript, is a scintillating fibres tracker of charged secondary particles (mainly protons) that will be operating during the treatment, allowing for an online range monitoring. Such monitoring technique is particularly promising in the context of heavy ions PT, in which the precision achievable by other techniques based on secondary photons detection is limited by the environmental background during the beam delivery. Developed and built at the SBAI department of "La Sapienza", within the INSIDE collaboration and as part of a Centro Fermi flagship project, the DP is a tracker detector specifically designed and planned for clinical applications inside a PT treatment room. The DP operation in clinical like conditions has been tested with the proton and carbon ions beams of Trento proton-therapy center and of the CNAO facility. In this contribution the detector performances are presented, in the context of the carbon ions monitoring clinical trial that is about to start at the CNAO centre.


Asunto(s)
Radioterapia de Iones Pesados/instrumentación , Radiometría/instrumentación , Humanos , Sistemas en Línea , Control de Calidad
8.
Phys Med ; 58: 114-120, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30824142

RESUMEN

PURPOSE: Radio-guided surgery with ß- decays is a novel technique under investigation. One of the main advantages is its capability to detect small (⩽0.1 ml) samples after injecting the patient with low activity of radiopharmaceutical. This paper presents an experimental method to quantify this feature based on ex-vivo tests on specimens from meningioma patients. METHODS: Patients were enrolled on the basis of the standard uptake value (SUV) and the tumour-to-non-tumour activity ratio (TNR) resulted from 68Ga-DOTATOC PET exams. After injecting the patients with 93-167 MBq of 90Y-DOTATOC, 26 samples excised during surgery were analyzed with a ß- probe. The radioactivity expected on the neoplastic specimens was estimated according to the SUV found in the PET scan and the correlation with the measured counts was studied. The doses to surgeon and medical personnel were also evaluated. RESULTS: Even injecting as low as 1.4 MBq/kg of radiotracer, tumour residuals of 0.1 ml can be detected. A negligible dose to the medical personnel was confirmed. CONCLUSIONS: Radio-guided surgery with ß- decays is a feasible technique with a low radiation dose for both personnel and patient, in particular if the patient is injected with the minimum required activity. A correlation greater than 80% was observed between the measured counts and the expected activity for the lesion samples based on the individual SUV and the TNR. This makes identifiable the minimum injectable radiotracer activity for cases where 90Y is the utilized radionuclide.


Asunto(s)
Partículas beta , Tomografía de Emisión de Positrones , Cirugía Asistida por Computador/métodos , Radioisótopos de Itrio/administración & dosificación , Humanos , Inyecciones , Meningioma/diagnóstico por imagen , Meningioma/cirugía , Exposición Profesional/análisis , Octreótido/administración & dosificación , Octreótido/análogos & derivados , Dosis de Radiación
9.
Pol J Vet Sci ; 21(3): 507-515, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30468339

RESUMEN

In humans, iron deficiency represents a relevant occurrence in heart failure (HF), with or without anaemia, and is associated with the worst outcome. Moreover, chronic kidney disease (CKD) is a well-known comorbidity of HF and is strongly associated with the risk of developing anaemia. The most common cause of HF in dogs is myxomatous mitral valve disease (MMVD). To the best of our knowledge, no studies have examined the iron status in dogs with HF, with and without CKD. The aim of this retrospective study was to evaluate the iron status in dogs affected by MMVD and how strong is the relation with HF. The retrospective study included 54 dogs with complete case records, echocardiography and laboratory analyses. Iron status was evaluated by measuring serum iron concentration (SIC), un- saturated iron binding capacity (UIBC), total iron binding capacity (TIBC), and percentage of saturation (%SAT). The prevalence of dogs showing low serum iron concentration (SIC) was 18% in the whole population, 33% in symptomatic patients, 100% in dogs with acute decompensated HF. No signif- icant differences in SIC, UIBC, TIBC and %SAT median values were found among dogs classi- fied in different ACVIM (American College of Veterinary Internal Medicine) classes, between symptomatic and non-symptomatic patients, and among IRIS (International Renal Interest Soci- ety) classes. Azotemic and non-azotemic patients presented a significant difference in SIC mean values (p=0.02). Generalised linear model (GLM) revealed that dogs with low SIC were at high- er risk of being included in a higher ACVIM class (OR=6.383, p-value=0.014). Log-rank analysis showed shorter survival in dogs with low SIC (p=0.020), multivariate Cox analysis revealed that only HF symptoms can affect survival.


Asunto(s)
Enfermedades de los Perros/sangre , Hierro/sangre , Insuficiencia de la Válvula Mitral/veterinaria , Animales , Perros , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/veterinaria , Masculino , Insuficiencia de la Válvula Mitral/sangre , Insuficiencia Renal/sangre , Insuficiencia Renal/veterinaria
10.
Phys Med Biol ; 63(5): 055018, 2018 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-29265011

RESUMEN

Proton and carbon ion beams are used in the clinical practice for external radiotherapy treatments achieving, for selected indications, promising and superior clinical results with respect to x-ray based radiotherapy. Other ions, like [Formula: see text] have recently been considered as projectiles in particle therapy centres and might represent a good compromise between the linear energy transfer and the radiobiological effectiveness of [Formula: see text] ion and proton beams, allowing improved tumour control probability and minimising normal tissue complication probability. All the currently used p, [Formula: see text] and [Formula: see text] ion beams allow achieving sharp dose gradients on the boundary of the target volume, however the accurate dose delivery is sensitive to the patient positioning and to anatomical variations with respect to photon therapy. This requires beam range and/or dose release measurement during patient irradiation and therefore the development of dedicated monitoring techniques. All the proposed methods make use of the secondary radiation created by the beam interaction with the patient and, in particular, in the case of [Formula: see text] ion beams are also able to exploit the significant charged radiation component. Measurements performed to characterise the charged secondary radiation created by [Formula: see text] and [Formula: see text] particle therapy beams are reported. Charged secondary yields, energy spectra and emission profiles produced in a poly-methyl methacrylate (PMMA) target by [Formula: see text] and [Formula: see text] beams of different therapeutic energies were measured at 60° and 90° with respect to the primary beam direction. The secondary yield of protons produced along the primary beam path in a PMMA target was obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The obtained measurements are in agreement with results reported in the literature and suggests the feasibility of range monitoring based on charged secondary particle detection: the implications for particle therapy monitoring applications are also discussed.


Asunto(s)
Radioterapia de Iones Pesados/efectos adversos , Helio/efectos adversos , Polimetil Metacrilato/efectos de la radiación , Monitoreo de Radiación/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Relación Dosis-Respuesta en la Radiación , Humanos , Dispersión de Radiación
11.
Phys Med Biol ; 62(8): 3299-3312, 2017 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-28350543

RESUMEN

Tumour control is performed in particle therapy using particles and ions, whose high irradiation precision enhances the effectiveness of the treatment, while sparing the healthy tissue surrounding the target volume. Dose range monitoring devices using photons and charged particles produced by the beam interacting with the patient's body have already been proposed, but no attempt has been made yet to exploit the detection of the abundant neutron component. Since neutrons can release a significant dose far away from the tumour region, precise measurements of their flux, production energy and angle distributions are eagerly sought in order to improve the treatment planning system (TPS) software. It will thus be possible to predict not only the normal tissue toxicity in the target region, but also the risk of late complications in the whole body. The aforementioned issues underline the importance of an experimental effort devoted to the precise characterisation of neutron production, aimed at the measurement of their abundance, emission point and production energy. The technical challenges posed by a neutron detector aimed at high detection efficiency and good backtracking precision are addressed within the MONDO (monitor for neutron dose in hadrontherapy) project, whose main goal is to develop a tracking detector that can target fast and ultrafast neutrons. A full reconstruction of two consecutive elastic scattering interactions undergone by the neutrons inside the detector material will be used to measure their energy and direction. The preliminary results of an MC simulation performed using the FLUKA software are presented here, together with the DSiPM (digital SiPM) readout implementation. New detector readout implementations specifically tailored to the MONDO tracker are also discussed, and the neutron detection efficiency attainable with the proposed neutron tracking strategy are reported.


Asunto(s)
Neutrones/uso terapéutico , Dosímetros de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Radioterapia/instrumentación , Radioterapia/métodos , Dosificación Radioterapéutica , Programas Informáticos
12.
Phys Med Biol ; 62(4): 1438-1455, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28114112

RESUMEN

Charged particle beams are used in particle therapy (PT) to treat oncological patients due to their selective dose deposition in tissues with respect to the photons and electrons used in conventional radiotherapy. Heavy (Z > 1) PT beams can additionally be exploited for their high biological effectiveness in killing cancer cells. Nowadays, protons and carbon ions are used in PT clinical routines. Recently, interest in the potential application of helium and oxygen beams has been growing. With respect to protons, such beams are characterized by their reduced multiple scattering inside the body, increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands online dose monitoring techniques, crucial to improving the quality assurance of any treatment: possible patient mis-positioning and biological tissue changes with respect to the planning CT scan could negatively affect the outcome of the therapy. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Among these secondary products, prompt photons are produced by nuclear de-excitation processes, and at present, different dose monitoring and beam range verification techniques based on prompt-γ detection are being proposed. It is hence of importance to perform γ yield measurement in therapeutic-like conditions. In this paper we report on the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target. The measurements were performed at the Heidelberg Ion-Beam Therapy Center (HIT) with beams of different energies. An LYSO scintillator, placed at [Formula: see text] and [Formula: see text] with respect to the beam direction, was used as the photon detector. The obtained γ yields for the carbon ion beams are compared with results from the literature, while no other results from helium and oxygen beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Fotones , Polimetil Metacrilato/efectos de la radiación , Conteo por Cintilación/métodos , Carbono/química , Carbono/uso terapéutico , Radioterapia de Iones Pesados/efectos adversos , Radioterapia de Iones Pesados/normas , Helio/química , Helio/uso terapéutico , Humanos , Transferencia Lineal de Energía , Terapia de Protones , Efectividad Biológica Relativa , Conteo por Cintilación/instrumentación
13.
Phys Med Biol ; 62(4): 1291-1309, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28114124

RESUMEN

Nowadays there is a growing interest in particle therapy treatments exploiting light ion beams against tumors due to their enhanced relative biological effectiveness and high space selectivity. In particular promising results are obtained by the use of 4He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments-protons, deuterons, and tritons-produced by 4He ion beams of 102, 125 and 145 MeV u-1 energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the treatment planning software being developed for clinical use of 4He beams in clinical routine and the relative bench-marking of Monte Carlo algorithm predictions.


Asunto(s)
Helio/uso terapéutico , Fantasmas de Imagen , Polimetil Metacrilato/química , Monitoreo de Radiación/métodos , Programas Informáticos , Algoritmos , Humanos , Método de Montecarlo , Protones , Planificación de la Radioterapia Asistida por Computador , Efectividad Biológica Relativa
14.
Phys Med ; 32(9): 1139-44, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27601248

RESUMEN

PURPOSE: A radio-guided surgery technique with ß(-)-emitting radio-tracers was suggested to overcome the effect of the large penetration of γ radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection. METHODS: A patient affected by meningioma was administered 300MBq of (90)Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a ß(-) probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation. RESULTS: we obtained a large signal on the bulk tumor (105cps) and a significant signal on residuals of ∼0.2ml (28cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (≈1cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity. CONCLUSIONS: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Meningioma/radioterapia , Tomografía de Emisión de Positrones , Radiocirugia/métodos , Cirugía Asistida por Computador/métodos , Anciano , Algoritmos , Partículas beta , Neoplasias Encefálicas/diagnóstico por imagen , Simulación por Computador , Estudios de Factibilidad , Femenino , Humanos , Meningioma/diagnóstico por imagen , Modelos Teóricos , Método de Montecarlo , Exposición Profesional/prevención & control , Octreótido/análogos & derivados , Octreótido/química , Radiometría , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...