Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Anal Chem ; 95(49): 17957-17961, 2023 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-38084380

RESUMEN

Biotransformation leading to single residue modifications (e.g., deamidation, oxidation) can contribute to decreased efficacy/potency, poor pharmacokinetics, and/or toxicity/immunogenicity for protein therapeutics. Identifying and characterizing such liabilities in vivo are emerging needs for biologics drug discovery. In vitro stress assays involving PBS for deamidation or AAPH for oxidation are commonly used for predicting liabilities in manufacturing and storage and are sometimes considered a predictive tool for in vivo liabilities. However, reports discussing their in vivo translatability are limited. Herein, we introduce a mass spectrometry workflow that characterizes in vivo oxidation and deamidation in pharmacokinetically relevant compartments for diverse protein therapeutic modalities. The workflow has low bias of <10% in quantitating degradation in the relevant pharmacokinetic concentration range for monkey and rabbit serum/plasma (1-100 µg/mL) and allows for high sequence coverage (∼85%) for discovery/monitoring of amino acid modifications. For oxidation and deamidation, the assay was precise, with percent coefficient of variation of <8% at 1-100 µg/mL and ≤6% method-induced artifacts. A high degree of in vitro and in vivo correlation was observed for deamidation on the six diverse protein therapeutics (seven liability sites) tested. In vivo translatability for oxidation liabilities were not observed for the 11 molecules tested using in vitro AAPH stress. One of the molecules dosed in eyes resulted in a false positive and a false negative prediction for in vivo oxidation following AAPH stress. Finally, peroxide stress was also tested but resulted in limited success (1 out of 4 molecules) in predicting oxidation liabilities.


Asunto(s)
Oxidación-Reducción , Animales , Conejos , Biotransformación
2.
Anal Chem ; 95(47): 17263-17272, 2023 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-37956201

RESUMEN

Intact protein mass spectrometry (MS) coupled with liquid chromatography was applied to characterize the pharmacokinetics and stability profiles of therapeutic proteins. However, limitations from chromatography, including throughput and carryover, result in challenges with handling large sample numbers. Here, we combined intact protein MS with multiple front-end separations, including affinity capture, SampleStream, and high-field asymmetric waveform ion mobility spectrometry (FAIMS), to perform high-throughput and specific mass measurements of a multivalent antibody with one antigen-binding fragment (Fab) fused to an immunoglobulin G1 (IgG1) antibody. Generic affinity capture ensures the retention of both intact species 1Fab-IgG1 and the tentative degradation product IgG1. Subsequently, the analytes were directly loaded into SampleStream, where each injection occurs within ∼30 s. By separating ions prior to MS detection, FAIMS further offered improvement in signal-overnoise by ∼30% for denatured protein MS via employing compensation voltages that were optimized for different antibody species. When enhanced FAIMS transmission of 1Fab-IgG1 was employed, a qualified assay was established for spiked-in serum samples between 0.1 and 25 µg/mL, resulting in ∼10% accuracy bias and precision coefficient of variation. Selective FAIMS transmission of IgG1 as the degradation surrogate product enabled more sensitive detection of clipped species for intact 1Fab-IgG1 at 5 µg/mL in serum, generating an assay to measure 1Fab-IgG1 truncation between 2.5 and 50% with accuracy and precision below 20% bias and coefficient of variation. Our results revealed that the SampleStream-FAIMS-MS platform affords high throughput, selectivity, and sensitivity for characterizing therapeutic antibodies from complex biomatrices qualitatively and quantitatively.


Asunto(s)
Inmunoglobulina G , Espectrometría de Movilidad Iónica , Espectrometría de Movilidad Iónica/métodos , Espectrometría de Masas/métodos , Cromatografía Liquida , Iones/química
3.
J Med Chem ; 66(19): 13384-13399, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37774359

RESUMEN

Protein tyrosine phosphatase SHP2 mediates RAS-driven MAPK signaling and has emerged in recent years as a target of interest in oncology, both for treating with a single agent and in combination with a KRAS inhibitor. We were drawn to the pharmacological potential of SHP2 inhibition, especially following the initial observation that drug-like compounds could bind an allosteric site and enforce a closed, inactive state of the enzyme. Here, we describe the identification and characterization of GDC-1971 (formerly RLY-1971), a SHP2 inhibitor currently in clinical trials in combination with KRAS G12C inhibitor divarasib (GDC-6036) for the treatment of solid tumors driven by a KRAS G12C mutation.

5.
Anal Chem ; 95(11): 4834-4839, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36876898

RESUMEN

The growing opportunities recognized for covalent drug inhibitors, like KRAS G12C inhibitors, are driving the need for mass spectrometry methods that can quickly and robustly measure therapeutic drug activity in vivo for drug discovery research and development. Effective front-end sample preparation is critical for proteins extracted from tumors but is generally labor intensive and impractical for large sample numbers typical in pharmacodynamic (PD) studies. Herein, we describe an automated and integrated sample preparation method for the measurement of activity levels of KRAS G12C drug inhibitor alkylation from complex tumor samples involving high throughput detergent removal and preconcentration followed by quantitation using mass spectrometry. We introduce a robust assay with an average intra-assay coefficient of variation (CV) of 4% and an interassay CV of 6% obtained from seven studies, enabling us to understand the relationship between KRAS G12C target occupancy and the therapeutic PD effect from mouse tumor samples. Further, the data demonstrated that the drug candidate GDC-6036, a KRAS G12C covalent inhibitor, shows dose-dependent target inhibition (KRAS G12C alkylation) and MAPK pathway inhibition, which correlate with high antitumor potency in the MIA PaCa-2 pancreatic xenograft model.


Asunto(s)
Antineoplásicos , Proteínas Proto-Oncogénicas p21(ras) , Humanos , Animales , Ratones , Proteínas Proto-Oncogénicas p21(ras)/genética , Línea Celular Tumoral , Mutación , Antineoplásicos/farmacología , Modelos Animales de Enfermedad
6.
Transl Vis Sci Technol ; 11(10): 27, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36255358

RESUMEN

Purpose: Diabetic macular edema (DME) is the leading cause of vision loss and blindness among working-age adults. Although current intravitreal anti-vascular endothelial growth factor (VEGF) therapies improve vision for many patients with DME, approximately half do not achieve the visual acuity required to drive. We therefore sought additional approaches to resolve edema and improve vision for these patients. Methods: We explored direct agonists of Tie2, a receptor known to stabilize vasculature and prevent leakage. We identified a multivalent PEG-Fab conjugate, Tie2.1-hexamer, that oligomerizes Tie2 and drives receptor activation and characterized its activities in vitro and in vivo. Results: Tie2.1-hexamer normalized and stabilized intercellular junctions of stressed endothelial cell monolayers in vitro, suppressed vascular leak in mice under conditions where anti-VEGF alone was ineffective, and demonstrated extended ocular exposure and robust pharmacodynamic responses in non-human primates. Conclusions: Tie2.1-hexamer directly activates the Tie2 pathway, reduces vascular leak, and is persistent within the vitreal humor. Translational Relevance: Our study presents a promising potential therapeutic for the treatment of DME.


Asunto(s)
Diabetes Mellitus , Retinopatía Diabética , Edema Macular , Ratones , Animales , Edema Macular/tratamiento farmacológico , Edema Macular/etiología , Retinopatía Diabética/tratamiento farmacológico , Factores de Crecimiento Endotelial/uso terapéutico , Agudeza Visual , Trastornos de la Visión/complicaciones , Trastornos de la Visión/tratamiento farmacológico , Ceguera/complicaciones
7.
Anal Chem ; 94(37): 12927-12933, 2022 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-36083155

RESUMEN

KRAS is one of the most frequently mutated oncogenes, with KRAS G12C recently becoming an actionable target for small molecule intervention. GDC-6036 is an investigational KRAS G12C inhibitor that acts by irreversibly binding to the switch II pocket of KRAS G12C when in the inactive GDP-bound state, thereby blocking GTP binding and activation. Assessing target engagement is an essential component of clinical drug development, helping to demonstrate mechanistic activity, guide dose selection, understand pharmacodynamics as it relates to clinical response, and explore resistance. Here, we report the development of an ultra-sensitive approach for assessing KRAS G12C engagement. Immunoaffinity enrichment with a commercially available anti-RAS antibody was combined with a targeted 2D-LC-MS/MS technique to quantify both free and GDC-6036-bound KRAS G12C proteins. A KRAS G12C-positive non-small cell lung cancer xenograft model was dosed with GDC-6036 to assess the feasibility of this assay for analyzing small core needle biopsies. As predicted, dose-dependent KRAS G12C engagement was observed. To date, a sensitivity of 0.08 fmol/µg of total protein has been achieved for both free and GDC-6036-bound KRAS G12C with as little as 4 µg of total protein extracted from human tumor samples. This sub-fmol/µg level of sensitivity provides a powerful potential approach to assess covalent inhibitor target engagement at the site of action using core needle tumor biopsies from clinical studies.


Asunto(s)
Antineoplásicos , Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Animales , Antineoplásicos/química , Biopsia , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Cromatografía Liquida , Guanosina Trifosfato , Humanos , Neoplasias Pulmonares/patología , Mutación , Proteínas Proto-Oncogénicas p21(ras)/genética , Proteínas Proto-Oncogénicas p21(ras)/metabolismo , Espectrometría de Masas en Tándem
8.
Anal Bioanal Chem ; 414(22): 6601-6610, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35821276

RESUMEN

Proteases are critical proteins involved in cleaving substrates that may impact biological pathways, cellular processes, or disease progression. In the biopharmaceutical industry, modulating the levels of protease activity is an important strategy for mitigating many types of diseases. While a variety of analytical tools exist for characterizing substrate cleavages, in vitro functional screening for antibody inhibitors of protease activity using physiologically relevant intact protein substrates remains challenging. In addition, detecting such large protein substrates with high heterogeneity using high-throughput mass spectrometry screening has rarely been reported in the literature with concerns for assay robustness and sensitivity. In this study, we established a peptide-based in vitro functional screening assay for antibody inhibitors of mouse bone morphogenic protein 1 (mBMP1) metalloprotease using a heterogeneous recombinant 66-kDa mouse Procollagen I alpha 1 chain (mProcollagen) substrate. We compared several analytical tools including capillary gel electrophoresis Western blot (CE-Western blot), as well as both intact protein and peptide-based mass spectrometry (MS) to quantitate the mBMP1 proteolytic activity and its inhibition by antibodies using this heterogeneous mProcollagen substrate. We concluded that the peptide-based mass spectrometry screening assay was the most suitable approach in terms of throughput, sensitivity, and assay robustness. We then optimized our mBMP1 proteolysis reaction after characterizing the enzyme kinetics using the peptide-based MS assay. This assay resulted in Z' values ranging from 0.6 to 0.8 from the screening campaign. Among over 1200 antibodies screened, IC50 characterization was performed on the top candidate hits, which showed partial or complete inhibitory activities against mBMP1.


Asunto(s)
Péptidos , Procolágeno , Animales , Espectrometría de Masas , Ratones , Péptido Hidrolasas/metabolismo , Péptidos/metabolismo , Procolágeno/metabolismo , Proteínas/metabolismo , Proteolisis , Especificidad por Sustrato
9.
Drug Metab Dispos ; 50(6): 846-857, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35306476

RESUMEN

Unlike with new chemical entities, the biotransformation of therapeutic proteins (TPs) has not been routinely investigated or included in regulatory filings. Nevertheless, there is an expanding pool of evidence suggesting that a more in-depth understanding of biotransformation could better aid the discovery and development of increasingly diverse modalities. For instance, such biotransformation analysis of TPs affords important information on molecular stability, which in turn may shed light on any potential impact on binding affinity, potency, pharmacokinetics, efficacy, safety, or bioanalysis. This perspective summarizes the current practices in studying biotransformation of TPs and related findings in the biopharmaceutical industry. Various TP case studies are discussed, and a fit-for-purpose approach is recommended when investigating their biotransformation. In addition, we provide a decision tree to guide the biotransformation characterization for selected modalities. By raising the awareness of this important topic, which remains relatively underexplored in the development of TPs (Bolleddula et al., 2022), we hope that current and developing practices can pave the way for establishing a consensus on the biotransformation assessment of TPs. SIGNIFICANCE STATEMENT: This article provides a comprehensive perspective of the current practices for exploring the biotransformation of therapeutic proteins across the drug development industry. We, the participants of the Innovation and Quality therapeutic protein absorption distribution metabolism excretion working group, recommend and summarize appropriate approaches for conducting biotransformation studies to support internal decision making based on the data generated in discovery and development.


Asunto(s)
Productos Biológicos , Industria Farmacéutica , Biotransformación , Humanos
10.
J Am Soc Mass Spectrom ; 32(8): 1886-1900, 2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-32869982

RESUMEN

Recent advancements in immunocapture methods and mass spectrometer technology have enabled intact protein mass spectrometry to be applied for the characterization of antibodies and other large biotherapeutics from in-life studies. Protein molecules have not been traditionally studied by intact mass or screened for catabolites in the same manner as small molecules, but the landscape has changed. Researchers have presented methods that can be applied to the drug discovery and development stages, and others are exploring the possibilities of the new approaches. However, a wide variety of options for assay development exists without clear recommendation on best practice, and data processing workflows may have limitations depending on the vendor. In this perspective, we share experiences and recommendations for current and future application of mass spectrometry for biotherapeutic molecule monitoring from preclinical and clinical studies.


Asunto(s)
Espectrometría de Masas/métodos , Proteínas/análisis , Proteínas/farmacocinética , Animales , Biotransformación , Cromatografía de Afinidad/métodos , Cromatografía Liquida , Evaluación Preclínica de Medicamentos , Humanos , Inmunoconjugados/análisis , Espectrometría de Masas/economía , Espectrometría de Masas/instrumentación , Proteínas/aislamiento & purificación , Manejo de Especímenes
11.
Proc Natl Acad Sci U S A ; 117(18): 9851-9856, 2020 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-32327606

RESUMEN

Toward the goal of increasing the throughput of high-resolution mass characterization of intact antibodies, we developed a RapidFire-mass spectrometry (MS) assay using electrospray ionization. We achieved unprecedented screening throughput as fast as 15 s/sample, which is an order of magnitude improvement over conventional liquid chromatography (LC)-MS approaches. The screening enabled intact mass determination as accurate as 7 ppm with baseline resolution at the glycoform level for intact antibodies. We utilized this assay to characterize and perform relative quantitation of antibody species from 248 samples of 62 different cell line clones at four time points in 2 h using RapidFire-time-of-flight MS screening. The screening enabled selection of clones with the highest purity of bispecific antibody production and the results significantly correlated with conventional LC-MS results. In addition, analyzing antibodies from a complex plasma sample using affinity-RapidFire-MS was also demonstrated and qualified. In summary, the platform affords high-throughput analyses of antibodies, including bispecific antibodies and potential mispaired side products, in cell culture media, or other complex matrices.


Asunto(s)
Anticuerpos Biespecíficos/sangre , Anticuerpos/sangre , Ensayos Analíticos de Alto Rendimiento/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Anticuerpos/aislamiento & purificación , Anticuerpos Biespecíficos/aislamiento & purificación , Línea Celular , Cromatografía Liquida/métodos , Humanos
12.
Anal Chem ; 92(10): 6839-6843, 2020 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-32309925

RESUMEN

There are many pharmacokinetic challenges associated with administering protein therapeutics, including biotransformation via clipping, deamidation, isomerization, oxidation, etc. In the case of engineered multivalent tethered antibody formats, proteolysis or deconjugation at the fusion or conjugation site present further issues. Unlike degradations associated with antibody drug conjugates, such biotransformations of tethered antibody formats usually result in degraded products with large mass differences. These large differences can result in processing or mass spectrometry response bias among the resulting product species that can lead to inaccurate stability quantitation. Herein, we describe an assay strategy for characterizing and quantitating degradations accurately for multivalent antibodies by incorporating response bias corrections. For the multivalent tethered antibody molecules selected, an ∼30-80% difference in response, compared to the cleaved product, was observed. To correct for the response bias, selected tethered multivalent antibodies and an IgG antibody (representing the stable intact and the degraded product species, respectively) were spiked in serum at known ratios for analysis. Following affinity capture, we generated calibration curves (five-parameter logistic fit p < 0.05) by plotting the measured ratios of the MS ion responses against the known spiked-in ratios (CVs < 8% for calibration standards). The qualified calibration curve (accuracy within 8% and 2% for measuring degradations of 5% and 15% product, respectively) was then used, through interpolation, to determine stability profiles for the same multivalent tethered antibody formats from both in vitro serum and pharmacokinetic study samples.


Asunto(s)
Anticuerpos/análisis , Inmunoconjugados/análisis , Cromatografía Liquida , Espectrometría de Masas
13.
MAbs ; 12(1): 1715705, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31997712

RESUMEN

For antibody-drug conjugates to be efficacious and safe, they must be stable in circulation to carry the payload to the site of the targeted cell. Several components of a drug-conjugated antibody are known to influence stability: 1) the site of drug attachment on the antibody, 2) the linker used to attach the payload to the antibody, and 3) the payload itself. In order to support the design and optimization of a high volume of drug conjugates and avoid unstable conjugates prior to testing in animal models, we wanted to proactively identify these potential liabilities. Therefore, we sought to establish an in vitro screening method that best correlated with in vivo stability. While traditionally plasma has been used to assess in vitro stability, our evaluation using a variety of THIOMABTM antibody-drug conjugates revealed several disconnects between the stability assessed in vitro and the in vivo outcomes when using plasma. When drug conjugates were incubated in vitro for 24 h in mouse whole blood rather than plasma and then analyzed by affinity capture LC-MS, we found an improved correlation to in vivo stability with whole blood (R2 = 0.87, coefficient of determination) compared to unfrozen or frozen mouse plasma (R2 = 0.34, 0.01, respectively). We further showed that this whole blood assay was also able to predict in vivo stability of other preclinical species such as rat and cynomolgus monkey, as well as in human. The screening method utilized short (24 h) incubation times, as well as a custom analysis software, allowing increased throughput and in-depth biotransformation characterization. While some instabilities that were more challenging to identify remain, the method greatly enhanced the process of screening, optimizing, and lead candidate selection, resulting in the substantial reduction of animal studies.


Asunto(s)
Cromatografía Liquida/métodos , Inmunoconjugados/química , Espectrometría de Masas/métodos , Animales , Humanos , Técnicas In Vitro , Estabilidad Proteica
14.
Anal Chem ; 92(2): 2186-2193, 2020 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-31880920

RESUMEN

With the rapid rise of therapeutic antibodies and antibody-drug conjugates, significant investments have been made in developing workflows that utilize mass spectrometry to detect these intact molecules, the large fragments generated by their selective digestion, and the peptides generated by traditional proteomics workflows. The resultant data is used to gain insight into a wide range of parameters, including primary sequence, disulfide bonding, glycosylation patterns, biotransformation, and more. However, many of the technologies utilized to couple these workflows to mass spectrometers have significant limitations that force nonoptimal modifications to upstream sample preparation steps, limit the throughput of high-volume workflows, and prevent the harmonization of diverse experiments onto a single hardware platform. Here, we describe a new analytical platform that enables direct and high-throughput coupling to electrospray ionization mass spectrometry. The SampleStream platform is compatible with both native and denaturing electrospray, operates with a throughput of up to 15 s/sample, provides extensive concentration of dilute samples, and affords similar sensitivity to comparable liquid chromatographic methods.


Asunto(s)
Anticuerpos Monoclonales/análisis , Ensayos Analíticos de Alto Rendimiento , Inmunoconjugados/análisis , Ensayos Analíticos de Alto Rendimiento/instrumentación , Programas Informáticos , Espectrometría de Masa por Ionización de Electrospray/instrumentación
15.
J Am Soc Mass Spectrom ; 29(7): 1532-1537, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29845559

RESUMEN

Antibody-drug conjugates (ADCs) present unique challenges for ligand-binding assays primarily due to the dynamic changes of the drug-to-antibody ratio (DAR) distribution in vivo and in vitro. Here, an automated on-tip affinity capture platform with subsequent mass spectrometry analysis was developed to accurately characterize the DAR distribution of ADCs from biological matrices. A variety of elution buffers were tested to offer optimal recovery, with trastuzumab serving as a surrogate to the ADCs. High assay repeatability (CV 3%) was achieved for trastuzumab antibody when captured below the maximal binding capacity of 7.5 µg. Efficient on-tip deglycosylation was also demonstrated in 1 h followed by affinity capture. Moreover, this tip-based platform affords higher throughput for DAR characterization when compared with a well-characterized bead-based method. Graphical Abstract ᅟ.


Asunto(s)
Inmunoconjugados/sangre , Espectrometría de Masas/métodos , Animales , Anticuerpos Monoclonales/sangre , Cromatografía Liquida/métodos , Haplorrinos , Humanos , Inmunoconjugados/química , Ratas
16.
SLAS Discov ; 22(10): 1211-1217, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28581894

RESUMEN

In recent years, the ability to unambiguously identify complex mixtures of analytes with high accuracy and resolving power in a label-free format continues to expand the application of mass spectrometry (MS) in the drug discovery process. This advantage combined with improved instrumentation makes MS suitable for targets with limited alternative assays for high-throughput screening (HTS). We describe a novel screening format using Self-Assembled Monolayers and matrix-assisted laser Desorption Ionization (SAMDI) technology. SAMDI enables affinity capture of a target protein for use in a small-molecule-binding assay format. Subsequent ionization enables the inferred identification of noncovalent compound interactions. SAMDI technology overcomes shot-to-shot variability by uniformly saturating the surface with captured protein, thereby minimizing matrix crystallization "hot spots." Furthermore, the combination with high-resolution matrix-assisted laser desorption/ionization time of flight significantly reduces interference of small-molecule detection from salt, detergent, and matrix. By using a pooled library format, the SAMDI assay can significantly improve the throughput of MS-based screening irrespective of enzyme activity. Finally, we demonstrate binding affinity rank ordering from a pool of compounds that correlates with potency data from a biochemical assay.


Asunto(s)
Bibliotecas de Moléculas Pequeñas/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Animales , Bioensayo , Bovinos , Estudios de Factibilidad , Soluciones
17.
Anal Chem ; 88(23): 11521-11526, 2016 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-27797494

RESUMEN

Deamidation of therapeutic antibodies may result in decreased drug activity and undesirable changes in pharmacokinetics and immunogenicity. Therefore, it is necessary to monitor the deamidation levels [during storage] and after in vivo administration. Because of the complexity of in vivo samples, immuno-affinity capture is widely used for specific enrichment of the target antibody prior to LC-MS. However, the conventional use of bead-based methods requires large sample volumes and extensive processing steps. Furthermore, with automation difficulties and extended sample preparation time, bead-based approaches may increase artificial deamidation. To overcome these challenges, we developed an automated platform to perform tip-based affinity capture of antibodies from complex matrixes with rapid digestion and peptide elution into 96-well microtiter plates followed by LC-MS analysis. Detailed analyses showed that the new method presents high repeatability and reproducibility with both intra and inter assay CVs < 8%. Using the automated platform, we successfully quantified the levels of deamidation of a humanized monoclonal antibody in cynomolgus monkeys over a time period of 12 weeks after administration. Moreover, we found that deamidation kinetics between in vivo samples and samples stressed in vitro at neutral pH were consistent, suggesting that the in vitro stress test may be used as a method to predict the liability to deamidation of therapeutic antibodies in vivo.


Asunto(s)
Anticuerpos/aislamiento & purificación , Anticuerpos/metabolismo , Desaminación , Animales , Anticuerpos/sangre , Anticuerpos/uso terapéutico , Automatización , Células CHO , Cromatografía Liquida , Cricetulus , Eritrocitos , Femenino , Citometría de Flujo , Humanos , Macaca fascicularis , Espectrometría de Masas
18.
J Proteome Res ; 14(12): 5252-62, 2015 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-26595531

RESUMEN

Structures similar to blood vessels in location, morphology, flexibility, and transparency have been recovered after demineralization of multiple dinosaur cortical bone fragments from multiple specimens, some of which are as old as 80 Ma. These structures were hypothesized to be either endogenous to the bone (i.e., of vascular origin) or the result of biofilm colonizing the empty osteonal network after degradation of original organic components. Here, we test the hypothesis that these structures are endogenous and thus retain proteins in common with extant archosaur blood vessels that can be detected with high-resolution mass spectrometry and confirmed by immunofluorescence. Two lines of evidence support this hypothesis. First, peptide sequencing of Brachylophosaurus canadensis blood vessel extracts is consistent with peptides comprising extant archosaurian blood vessels and is not consistent with a bacterial, cellular slime mold, or fungal origin. Second, proteins identified by mass spectrometry can be localized to the tissues using antibodies specific to these proteins, validating their identity. Data are available via ProteomeXchange with identifier PXD001738.


Asunto(s)
Vasos Sanguíneos/anatomía & histología , Vasos Sanguíneos/metabolismo , Dinosaurios/anatomía & histología , Dinosaurios/metabolismo , Fósiles/anatomía & histología , Actinas/genética , Actinas/aislamiento & purificación , Secuencia de Aminoácidos , Animales , Vasos Sanguíneos/microbiología , Huesos/irrigación sanguínea , Pollos , Dinosaurios/genética , Técnica del Anticuerpo Fluorescente/métodos , Espectrometría de Masas , Modelos Biológicos , Datos de Secuencia Molecular , Miosinas/genética , Miosinas/aislamiento & purificación , Filogenia , Proteómica/métodos , Alineación de Secuencia , Especificidad de la Especie , Struthioniformes , Tropomiosina/genética , Tropomiosina/aislamiento & purificación , Tubulina (Proteína)/genética , Tubulina (Proteína)/aislamiento & purificación
19.
J Proteome Res ; 14(5): 2199-206, 2015 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-25836738

RESUMEN

A fractionation method called gel-eluted liquid fraction entrapment electrophoresis (GELFrEE) has been used to dramatically increase the number of proteins identified in top-down proteomic workflows; however, the technique involves the use of sodium dodecyl sulfate (SDS), a surfactant that interferes with electrospray ionization. Therefore, an efficient removal of SDS is absolutely required prior to mass analysis. Traditionally, methanol/chloroform precipitation and spin columns have been used, but they lack reproducibility and are difficult to automate. Therefore, we developed an in-line matrix removal platform to enable the direct analysis of samples containing SDS and salts. Only small molecules like SDS permeate a porous membrane and are removed in a manner similar to cross-flow filtration. With this device, near-complete removal of SDS is accomplished within 5 min and proteins are subsequently mobilized into a mass spectrometer. The new platform was optimized for the analysis of GELFrEE fractions enriched for histones extracted from human HeLa cells. All four core histones and their proteoforms were detected in a single spectrum by high-resolution mass spectrometry. The new method versus protein precipitation/resuspension showed 2- to 10-fold improved signal intensities, offering a clear path forward to improve proteome coverage and the efficiency of top-down proteomics.


Asunto(s)
Electroforesis/instrumentación , Histonas/aislamiento & purificación , Dodecil Sulfato de Sodio/aislamiento & purificación , Espectrometría de Masa por Ionización de Electrospray/métodos , Calibración , Electroforesis/métodos , Células HeLa , Humanos , Membranas Artificiales , Porosidad , Isoformas de Proteínas/aislamiento & purificación , Estándares de Referencia , Dodecil Sulfato de Sodio/química
20.
Proteomics ; 14(10): 1158-64, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24596178

RESUMEN

The direct analysis of intact proteins via MS offers compelling advantages in comparison to alternative methods due to the direct and unambiguous identification and characterization of protein sequences it provides. The inability to efficiently analyze proteins in the "middle mass range," defined here as proteins from 30 to 80 kDa, in a robust fashion has limited the adoption of these "top-down" methods. Largely, a result of poor liquid chromatographic performance, the limitations in this mass range may be addressed by alternative separations that replace chromatography. Herein, the short migration times of CZE-ESI-MS/MS have been extended to size-sorted whole proteins in complex mixtures from Pseudomonas aeruginosa PA01. An electrokinetically pumped nanospray interface, a coated capillary, and a stacking method for on-column sample concentration were developed to achieve high-loading capacity and separation resolution. We achieved full width at half maximum of 8-16 s for model proteins up to 29 kDa and identified 30 proteins in the mass range of 30-80 kDa from P. aeruginosa PA01 whole cell lysate. These results suggest that CZE-ESI-MS/MS is capable of identifying proteins in the middle mass range in top-down proteomics.


Asunto(s)
Electroforesis Capilar/métodos , Proteínas/análisis , Proteínas/química , Proteómica/métodos , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Datos de Secuencia Molecular , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...