Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Plant Physiol ; 195(2): 1432-1445, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38478576

RESUMEN

Anion transporters sustain a variety of physiological states in cells. Bestrophins (BSTs) belong to a Cl- and/or HCO3- transporter family conserved in bacteria, animals, algae, and plants. Recently, putative BSTs were found in the green alga Chlamydomonas reinhardtii, where they are upregulated under low CO2 (LC) conditions and play an essential role in the CO2-concentrating mechanism (CCM). The putative BST orthologs are also conserved in diatoms, secondary endosymbiotic algae harboring red-type plastids, but their physiological functions are unknown. Here, we characterized the subcellular localization and expression profile of BSTs in the marine diatoms Phaeodactylum tricornutum (PtBST1 to 4) and Thalassiosira pseudonana (TpBST1 and 2). PtBST1, PtBST2, and PtBST4 were localized at the stroma thylakoid membrane outside of the pyrenoid, and PtBST3 was localized in the pyrenoid. Contrarily, TpBST1 and TpBST2 were both localized in the pyrenoid. These BST proteins accumulated in cells grown in LC but not in 1% CO2 (high CO2 [HC]). To assess the physiological functions, we generated knockout mutants for the PtBST1 gene by genome editing. The lack of PtBST1 decreased photosynthetic affinity for dissolved inorganic carbon to the level comparable with the HC-grown wild type. Furthermore, non-photochemical quenching in LC-grown cells was 1.5 to 2.0 times higher in the mutants than in the wild type. These data suggest that HCO3- transport at the stroma thylakoid membranes by PtBST1 is a critical part of the CO2-evolving machinery of the pyrenoid in the fully induced CCM and that PtBST1 may modulate photoprotection under CO2-limited environments in P. tricornutum.


Asunto(s)
Dióxido de Carbono , Diatomeas , Fotosíntesis , Dióxido de Carbono/metabolismo , Diatomeas/genética , Diatomeas/metabolismo , Diatomeas/fisiología , Fotosíntesis/genética , Proteínas de Transporte de Anión/metabolismo , Proteínas de Transporte de Anión/genética
2.
Radiol Phys Technol ; 17(2): 375-388, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38461220

RESUMEN

Using numerical indices and visual evaluation, we evaluated the dependence of coronary-artery depictability on the denoising parameter in compressed sensing magnetic resonance angiography (CS-MRA). This study was conducted to clarify the acceleration factor (AF) and denoising factor (DF) dependence of CS-MRA image quality. Vascular phantoms and clinical images were acquired using three-dimensional CS-MRA on a clinical 1.5 T system. For the phantom measurements, we compared the full width at half maximum (FWHM), sharpness, and contrast ratio of the vascular profile curves for various AFs and DFs. In the clinical cases, the FWHM, sharpness, contrast ratio, signal-to-noise ratio, noise level values, and visual evaluation results were compared for various DFs. Phantom image analyses demonstrated that the respective measurements of the FWHM, sharpness, and contrast ratios did not significantly change with an increase in AF. The FWHM and sharpness measurements slightly changed with the DF level. However, the contrast ratio tended to increase with an increase in the DF level. In the clinical cases, the FWHM and sharpness showed no significant differences, even when the DF level was changed. However, the contrast ratio tended to decrease as the DF level increased. When the DF levels of the clinical cases increased, the background signals of the myocardium, fat, and noise levels decreased. We investigated the dependence of the coronary-artery depictability on AF and DF using CS-MRA. Analysis of the coronary-artery profile curves indicated that a better image quality was achieved with a stronger DF on coronary CS-MRA.


Asunto(s)
Vasos Coronarios , Angiografía por Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido , Humanos , Angiografía por Resonancia Magnética/métodos , Vasos Coronarios/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Femenino , Procesamiento de Imagen Asistido por Computador/métodos , Anciano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA