Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Oral Implantol ; 50(3): 127-135, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38530824

RESUMEN

This study evaluated the clinical survival rates of 170 Morse taper implants through clinical and mechanical parameters in different therapeutic approaches such as single crowns, fixed partial prostheses, and fixed full-arch prostheses. Patients referred to the Center on Education and Research on Dental Implants from May 2017 to July 2018 with the indication for dental implant therapy, aged >18 years, without periodontal disease, recent evidence of inflammatory activity or other oral disorders, current pregnancy, uncontrolled diabetes mellitus or heavy smoking habit were included in this study. After 12 weeks of healing since the implants were placed in the mandible and after 16 weeks following implants placed in the maxilla, patients returned to the Center for prosthetic rehabilitation. After implant therapy, all patients underwent periodical, clinical, and prosthetic examinations every 6 months. Prosthetic restorations involved 109 fixed reconstructions in function. Few prosthetic complications were reported (6.55%). Twenty implants were rehabilitated with cemented prostheses; from those, 1 crown suffered a loss in retention/decementation. Of the 148 implants rehabilitated with screwed-retained prostheses, 6.76% suffered prosthetic screw loosening. The cumulative implant survival rate was 98.2%. When peri-implant tissue health was evaluated, the keratinized mucosa band appeared related to peri-implant tissue stability. Thus, Morse taper implants represented a successful procedure for implant rehabilitation, with a high cumulative implant survival rate, low prevalence of biological and prosthetic complications, and good stability of peri-implant tissues over the assessed period.


Asunto(s)
Implantes Dentales , Humanos , Estudios de Seguimiento , Femenino , Persona de Mediana Edad , Masculino , Adulto , Prótesis Dental de Soporte Implantado , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Anciano , Implantación Dental Endoósea , Coronas
2.
Artículo en Inglés | MEDLINE | ID: mdl-32429405

RESUMEN

Decompression or healing chambers between the threads have been proposed to improve and accelerate the osseointegration process of dental implants. The aim of the present work was to test, in an in vivo sheep study, if healing chambers between the threads could produce a better osseointegration process. Thirty titanium implants (15 conventional design (control) and 15 implants with healing chambers (test)) were inserted in a random fashion in the tibia of 3 sheep. The animals were euthanized after 30 days of healing, and the retrieved specimens treated to obtain thin ground sections. Histological observations showed that the quantity of newly formed bone growing in an apical direction was lower in the control group (1095 µm) when compared to the Test group (1658 µm). This difference was statistically significant. Moreover, a layer of osteogenic matrix was present around the portion of implants immersed in the marrow spaces. This osteogenic tissue was thicker in the test group. In conclusion, the present study confirmed the very good results in implants with healing chambers that presented a higher percentage of new bone formation.


Asunto(s)
Oseointegración , Tibia , Animales , Médula Ósea , Interfase Hueso-Implante , Osteogénesis , Ovinos , Propiedades de Superficie , Titanio
3.
J Oral Implantol ; 45(3): 202-206, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30875272

RESUMEN

The aim of this in vitro study was to evaluate the effect of air polishing on the implant abutment surface using different abrasive powders: sodium bicarbonate and amino acid glycine. Fifteen grade III machined surface titanium disks with 8-mm diameter and 2-mm thickness were divided in 3 groups of 5 samples each and subjected to air polishing for 20 seconds with an Ultrajet Flex air-abrasive device and a distinct prophylaxis protocol: air and water (G1); air, water, and sodium bicarbonate (G2); and air, water; and amino acid glycine (G3). After the air polishing, the average roughness (Ra) of the samples was measured using an optical profilometer, and the obtained data were statistically analyzed. We found that G1 and G3 had similar Ra, while Ra values for G2 were significantly higher. This study demonstrated that air-polishing powders containing glycine had less of an effect on the roughness of the surface of titanium disks compared with sodium bicarbonate powders. Future in vivo studies will be conducted to investigate the clinical relevance of the present results.


Asunto(s)
Pilares Dentales , Implantes Dentales , Pulido Dental , Bicarbonato de Sodio , Ensayo de Materiales , Polvos , Propiedades de Superficie , Titanio