Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Med Econ ; 27(1): 826-835, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38889094

RESUMEN

BACKGROUND AND AIMS: Cardiac ablation is a well-established method for treating atrial fibrillation (AF). Pulsed field ablation (PFA) is a non-thermal therapeutic alternative to radiofrequency ablation (RFA) and cryoballoon ablation (CRYO). PFA uses high-voltage electric pulses to target cells. The present analysis aims to quantify the costs, outcomes, and resources associated with these three ablation strategies for paroxysmal AF. METHODS: Real-world clinical data were prospectively collected during index hospitalization by three European medical centers (Belgium, Germany, the Netherlands) specialized in cardiac ablation. These data included procedure times (pre-procedural, skin-to-skin and post-procedural), resource use, and staff burden. Data regarding complications associated with each of the three treatment options and redo procedures were extracted from the literature. Costs were collected from hospital economic formularies and published cost databases. A cost-consequence model from the hospital perspective was built to estimate the impact of the three treatment options in terms of effectiveness and costs. RESULTS: Across the three centers, N = 91 patients were included over a period of 12 months. A significant difference was seen in pre-procedural time (mean ± SD, PFA: 13.6 ± 3.7 min, CRYO: 18.8 ± 6.6 min, RFA: 20.4 ± 6.4 min; p < .001). Procedural time (skin-to-skin) was also different across alternatives (PFA: 50.9 ± 22.4 min, CRYO: 74.5 ± 24.5 min, RFA: 140.2 ± 82.4 min; p < .0001). The model reported an overall cost of €216,535 per 100 patients treated with PFA, €301,510 per 100 patients treated with CRYO and €346,594 per 100 patients treated with RFA. Overall, the cumulative savings associated with PFA (excluding kit costs) were €850 and €1,301 per patient compared to CRYO and RFA, respectively. CONCLUSION: PFA demonstrated shorter procedure time compared to CRYO and RFA. Model estimates indicate that these time savings result in cost savings for hospitals and reduce outlay on redo procedures. Clinical practice in individual hospitals varies and may impact the ability to transfer the results of this analysis to other settings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Análisis Costo-Beneficio , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/economía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/economía , Ablación por Catéter/métodos , Anciano , Tempo Operativo , Estudios Prospectivos , Europa (Continente) , Criocirugía/economía , Criocirugía/métodos , Complicaciones Posoperatorias/economía , Recursos en Salud/estadística & datos numéricos , Recursos en Salud/economía
2.
Telemed J E Health ; 22(10): 798-808, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27285946

RESUMEN

AIMS: Recently, a permanently implantable wireless system, designed to monitor and manage pulmonary artery (PA) pressures remotely, demonstrated significant reductions in heart failure (HF) hospitalizations in high-risk symptomatic patients, regardless of ejection fraction. The objectives of this study were to simulate the estimated clinical and economic impact in Germany of generalized use of this PA pressure monitoring system considering reductions of HF hospitalizations and the improvement in Quality of Life. MATERIALS AND METHODS: Based on the Prospective Health Technology Assessment approach, we simulated the potential of the widespread application of PA pressure monitoring on the German healthcare system for the period 2009-2021. RESULTS: This healthcare economic simulation formulated input assumptions based on results from the CHAMPION Trial, a multicenter, prospective, randomized controlled U.S. trial that demonstrated a 37% reduction of hospitalizations in persistently symptomatic previous HF patients. Based on these results, an estimated 114,800 hospitalizations would expected to be avoided. This effect would potentially save an estimated €522 million, an equivalent of $575 million, during the entire simulation period. CONCLUSION: This healthcare economic modeling of the PA pressure monitoring system's impact demonstrates substantial clinical and economic benefits in the German healthcare system.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial/métodos , Insuficiencia Cardíaca/economía , Insuficiencia Cardíaca/fisiopatología , Arteria Pulmonar , Tecnología de Sensores Remotos/métodos , Telemedicina/métodos , Anciano , Anciano de 80 o más Años , Monitoreo Ambulatorio de la Presión Arterial/economía , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Simulación por Computador , Femenino , Alemania , Hospitalización/economía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Tecnología de Sensores Remotos/economía , Tecnología de Sensores Remotos/instrumentación , Telemedicina/economía , Telemedicina/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA