1.
Pediatr Res ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937641

RESUMEN

BACKGROUND: Central venous access devices (CVAD) are associated with central line associated bloodstream infection (CLABSI) and venous thromboembolism (VTE). We identified trends in non-intensive care unit (ICU) CVAD utilization, described complication rates, and compared resources between low and high CVAD sites. METHODS: We combined data from the Pediatric Health Information System (PHIS) database and surveys from included hospitals. We analyzed 10-year trends in CVAD encounters for non-ICU children between 01/2012-12/2021 and described variation and complication rates between 01/2017-12/2021. Using Fisher's exact test, we compared resources between low and high CVAD users. RESULTS: CVAD use decreased from 6.3% to 3.8% of hospitalizations over 10 years. From 2017-2021, 67,830 encounters with CVAD were identified. Median age was 7 (IQR 2-13) years; 46% were female. Significant variation in CVAD utilization exists (range 1.4-16.9%). Rates of CLABSI and VTE were 4.0% and 3.4%, respectively. Survey responses from 33/41 (80%) hospitals showed 91% had vascular access teams, 30% used vascular access selection guides, and 70% used midline/long peripheral catheters. Low CVAD users were more likely to have a team guiding device selection (100% vs 43%, p = 0.026). CONCLUSIONS: CVAD utilization decreased over time. Significant variation in CVAD use remains and may be associated with hospital resources. IMPACT: Central venous access device (CVAD) use outside of the ICU is trending down; however, significant variation exists between institutions. Children with CVADs hospitalized on the acute care units had a CLABSI rate of 4% and VTE rate of 3.4%. 91% of surveyed institutions have a vascular access team; however, the services provided vary between institutions. Even though 70% of the surveyed institutions have the ability to place midline/long peripheral catheters, the majority use these catheters less than a few times per month. Institutions with low CVAD use are more likely to have a vascular access team that guides device selection.

2.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38940297

RESUMEN

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Diseño de Equipo , Falla de Equipo , Ensayos Clínicos Controlados Aleatorios como Asunto , Tromboembolia Venosa , Humanos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Infecciones Relacionadas con Catéteres/prevención & control , Tromboembolia Venosa/prevención & control , Tromboembolia Venosa/etiología , Obstrucción del Catéter , Catéteres Venosos Centrales/efectos adversos , Causas de Muerte , Sesgo , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Bacteriemia/prevención & control , Bacteriemia/etiología
3.
J Adv Nurs ; 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38896020

RESUMEN

Paediatric patients with complex or acute conditions may require a central venous access device, however, almost one-third of these devices have associated complications (e.g. infections). Implementation of evidence-based practices regarding central venous access devices can reduce and potentially prevent complications. AIMS: This scoping review aimed to explore recent interventional research in CVAD management through an implementation lens. DESIGN: This scoping review used the Arksey and O'Malley framework. Studies were included if they were written in English, published in 2012 to July 2023, involved children and were relevant to the study aims. Risk of bias was appraised by the Mixed Methods Appraisal Tool. DATA SOURCES: Searches were undertaken in EMBASE, CINAHL (Ebsco), PubMed, Web of Science and Cochrane Library (CENTRAL). RESULTS: Of the 1769 studies identified in a systematic search, 46 studies were included. Studies mostly focused on health professionals and central venous access device maintenance and had quantitative pre-post study designs. Adherence to implementation frameworks was lacking, with many studies employing quality improvement approaches. Implementation strategies were typically multipronged, using health-professional education, bundles and working groups. Bundle compliance and reductions in central line-associated bloodstream infections were the most featured outcomes, with most studies primarily focusing on effectiveness outcomes. CONCLUSION: Translation of evidence-based practices to the clinical setting is difficult and current adoption of implementation frameworks (apart from 'quality improvement') is limited. Implementation strategies are diverse and dependent on the local context, and study outcomes typically focus on the effectiveness of the physical intervention, rather than measuring the implementation effort itself. IMPLICATIONS FOR PATIENTS: Future intervention research requires a more uniform and deliberate application of implementation frameworks and strategies. IMPACT: Greater exploration of relationships between frameworks and strategies and implementation and service outcomes is required to increase understanding of their role in maximizing resources to improve health care. Adhered to best reporting guidelines as per PRISMA-ScR (Tricco et al., 2018). PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

4.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-38780138

RESUMEN

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Asunto(s)
Vendajes , Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Poliuretanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Infecciones Relacionadas con Catéteres/prevención & control , Sesgo , Falla de Equipo
5.
Semin Oncol Nurs ; 40(3): 151618, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38622044

RESUMEN

OBJECTIVES: To identify the prevalence and type of central venous access device-associated skin complications for adult cancer patients, describe central venous access device management practices, and identify clinical and demographic characteristics associated with risk of central venous access device-associated skin complications. METHODS: A prospective cohort study of 369 patients (626 central venous access devices; 7,682 catheter days) was undertaken between March 2017 and March 2018 across two cancer care in-patient units in a large teaching hospital. RESULTS: Twenty-seven percent (n = 168) of participants had a central venous access device-associated skin complication. In the final multivariable analysis, significant (P < .05) risk factors for skin complications were cutaneous graft versus host disease (2.1 times greater risk) and female sex (1.4 times greater risk), whereas totally implanted vascular access device reduced risk for skin complications by two-thirds (incidence risk ratio 0.37). CONCLUSION: Central venous access device-associated skin complications are a significant, potentially avoidable injury, requiring cancer nurses to be aware of high-risk groups and use evidence-based preventative and treatment strategies. IMPLICATIONS FOR PRACTICE: This study has confirmed how common these potentially preventable injuries are. Therefore, the prevalence of these complications could be reduced by focusing on improvements in skin assessment, reductions in central venous access device dressing variation and improving clinician knowledge of this injury.


Asunto(s)
Cateterismo Venoso Central , Neoplasias , Humanos , Femenino , Masculino , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Adulto , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Enfermedades de la Piel/etiología , Enfermedades de la Piel/epidemiología , Factores de Riesgo , Anciano de 80 o más Años , Estudios de Cohortes
6.
J Adv Nurs ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38468151

RESUMEN

BACKGROUND: Hospital-acquired pressure injuries (HAPIs) pose significant challenges in healthcare and cause increased patient suffering, longer hospital stays, and higher healthcare costs. Paediatric patients face unique risks, but evidence remains scarce. This study aimed to identify and describe HAPI admission incidence and severity predictors in a large Australian children's hospital. METHODS: This retrospective cohort study investigated all paediatric patients between January 2020 and December 2021 using a census approach. Demographic and clinical data including HAPI-related data were accessed from the incident monitoring and hospital administration databases. The incidence rate (per 1000 patient admissions) was calculated based on all admissions. Predictors of HAPI severity were identified using multivariable multinomial logistic regression. The study adhered to the STROBE guidelines for retrospective cohort studies. RESULTS: The HAPI incidence rate was 6.96 per 1000 patient admissions. Of the age groups, neonates had the highest HAPI incidence (15.5 per 1000 admissions). Critically ill children had the highest rate for admission location (12.8 per 1000 patient admissions). Most reported cases were stage I (64.2%). Age was associated with injury severity, with older paediatric patients more likely to develop higher-stage HAPIs. Additionally, Aboriginal and/or Torres Strait Islander patients had a higher HAPI severity risk. CONCLUSION: HAPI injuries in paediatric patients are unacceptably high. Prevention should be prioritized, and the quality of care improved in Australia and beyond. Further research is needed to develop targeted prevention strategies for these vulnerable populations. IMPLICATIONS FOR THE PROFESSION AND PATIENT CARE: This research emphasizes the need for standardized reporting, culturally sensitive care and tailored prevention strategies. IMPACT: The research has the potential to influence healthcare policies and practices, ultimately enhancing the quality of patient care. REPORTING METHOD: STROBE guidelines. NO PATIENT OR PUBLIC CONTRIBUTION: There was no patient or public contribution to the conduct of this study.

7.
Hosp Pediatr ; 14(3): 180-188, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38404202

RESUMEN

OBJECTIVES: This study aimed to describe how the current practice of peripherally inserted central catheter (PICC) use in hospitalized children aligns with the Michigan Appropriateness Guide for Intravenous Catheters (miniMAGIC) in Children recommendations, explore variation across sites, and describe the population of children who do not receive appropriate PICCs. METHODS: A retrospective study was conducted at 4 children's hospitals in the United States. Children with PICCs placed January 2019 to December 2021 were included. Patients in the NICU were excluded. PICCs were categorized using the miniMAGIC in Children classification as inappropriate, uncertain appropriateness and appropriate. RESULTS: Of the 6051 PICCs identified, 9% (n = 550) were categorized as inappropriate, 9% (n = 550) as uncertain appropriateness, and 82% (n = 4951) as appropriate. The number of PICCs trended down over time, but up to 20% of PICCs each year were not appropriate, with significant variation between sites. Within inappropriate or uncertain appropriateness PICCs (n = 1100 PICC in 1079 children), median (interquartile range) patient age was 4 (0-11) years, 54% were male, and the main reason for PICC placement was prolonged antibiotic course (56%, n = 611). The most common admitting services requesting the inappropriate/uncertain appropriateness PICCs were critical care 24%, general pediatrics 22%, and pulmonary 20%. Complications resulting in PICC removal were identified in 6% (n = 70) of inappropriate/uncertain PICCs. The most common complications were dislodgement (3%) and occlusion (2%), with infection and thrombosis rates of 1% (n = 10 and n = 13, respectively). CONCLUSIONS: Although the majority of PICCs met appropriateness criteria, a substantial proportion of PICCs were deemed inappropriate or of uncertain appropriateness, illustrating an opportunity for quality improvement.


Asunto(s)
Antibacterianos , Cateterismo Periférico , Niño , Preescolar , Femenino , Humanos , Masculino , Cateterismo Periférico/efectos adversos , Catéteres , Niño Hospitalizado , Estudios Retrospectivos , Recién Nacido , Lactante
9.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38413831

RESUMEN

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Asunto(s)
Telemedicina , Adulto , Niño , Humanos , Estudios Prospectivos , Telemedicina/métodos , Atención a la Salud , Padres , Comunicación
10.
J Pediatr Nurs ; 76: 68-75, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38364591

RESUMEN

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Asunto(s)
Telemedicina , Dispositivos de Acceso Vascular , Humanos , Niño , Aplicaciones Móviles , Masculino , Femenino , Enfermedad Crónica , Enfermería Pediátrica
11.
Pediatr Res ; 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38200324

RESUMEN

BACKGROUND AND AIMS: Invasive devices are widely used in healthcare settings; however, pediatric patients are especially vulnerable to invasive device-associated harm. This study aimed to explore invasive device utility, prevalence, harm, and clinical practice across three Australian pediatric tertiary hospitals. METHODS: In 2022-2023, a multi-center, observational, rolling-point-prevalence survey was conducted. Fifty-per-cent of inpatients were systemically sampled by random allocation. Patients with devices were then followed for up to 3-days for device-related complications/failures and management/removal characteristics. RESULTS: Of the 285 patients audited, 78.2% had an invasive device (n = 412 devices), with a median of 1 device-per-patient (interquartile range 1-2), with a maximum of 13 devices-per-patient. Over half of devices were vascular access devices (n = 223; 54.1%), followed by gastrointestinal devices (n = 112; 27.2%). The point-prevalence of all device complications on Day 0 was 10.7% (44/412 devices) and period-prevalence throughout the audit period was 27.7% (114/412 devices). The period-prevalence of device failure was 13.4% (55/412 devices). CONCLUSIONS: The study highlighted a high prevalence of invasive devices among hospitalized patients. One-in-ten devices failed during the audit period. These findings underscore the need for vigilant monitoring and improved strategies to minimize complications and enhance the safety of invasive devices in pediatric hospital settings. IMPACT: A high prevalence of invasive devices among hospitalized patients was reported. Of the 285 patients audited, almost 80% had an invasive device (total 412 devices), with a median of 1 device-per-patient and a maximum of 13 devices-per-patient. The most common devices used in pediatric healthcare are vascular access devices (n = 223; 54.1%), however, 16% (n = 36) of these devices failed, and one-third had complications. The point prevalence of all device complications at day 0 was 10.7% (44 out of 412 devices), with a period prevalence of 27.7% (114 out of 412 devices) throughout the audit period.

12.
Int J Nurs Stud ; 151: 104673, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38142634

RESUMEN

BACKGROUND: Peripheral intravenous catheters are the most frequently used invasive device in nursing practice, yet are commonly associated with complications. We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METHODS: The Cochrane Library, PubMed, CINAHL, and EMBASE were searched for observational studies and randomised controlled trials that reported peripheral intravenous catheter related infections or failure. The review was limited to English language and articles published from the year 2000. Pooled estimates were calculated with random-effects models. Meta-analysis of observation studies in epidemiology guidelines and the Cochrane process for randomised controlled trials were used to guide the review. Prospero registration number: CRD42022349956. FINDINGS: Our search retrieved 34,725 studies. Of these, 41 observational studies and 28 randomised controlled trials (478,586 peripheral intravenous catheters) met inclusion criteria. The pooled proportion of catheter-associated bloodstream infections was 0.028 % (95 % confidence interval (CI): 0.009-0.081; 38 studies), or 4.40 catheter-associated bloodstream infections per 100,000 catheter-days (20 studies, 95 % CI: 3.47-5.58). Local infection was reported in 0.150 % of peripheral intravenous catheters (95 % CI: 0.047-0.479, 30 studies) with an incidence rate of 65.1 per 100,000 catheter-days (16 studies; 95 % CI: 49.2-86.2). All cause peripheral intravenous catheter failure before treatment completion occurred in 36.4 % of catheters (95 % CI: 31.7-41.3, 53 studies) with an overall incidence rate of 4.42 per 100 catheter days (78,891 catheter days; 19 studies; 95 % CI: 4.27-4.57). INTERPRETATION: Peripheral intravenous catheter failure is a significant worldwide problem, affecting one in three catheters. Per peripheral intravenous catheter, infection occurrence was low, however, with over two billion catheters used globally each year, the absolute number of infections and associated burden remains high. Substantial and systemwide efforts are needed to address peripheral intravenous catheter infection and failure and the sequelae of treatment disruption, increased health costs and poor patient outcomes.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Flebitis , Sepsis , Humanos , Flebitis/etiología , Infecciones Relacionadas con Catéteres/epidemiología , Catéteres , Cateterismo Periférico/efectos adversos , Sepsis/complicaciones
13.
Aust Crit Care ; 37(1): 34-42, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38142148

RESUMEN

BACKGROUND: Endotracheal suction is used to maintain endotracheal tube patency. There is limited guidance to inform clinical practice for children with respiratory infections. OBJECTIVE: The objective of this study was to determine whether implementation of a paediatric endotracheal suction appropriate use guideline Paediatric AirWay Suction (PAWS) is associated with an increased use of appropriate and decreased use of inappropriate suction interventions. METHODS: A mixed-method, pre-implementation-post-implementation study was conducted between September 2021 and April 2022. Suction episodes in mechanically ventilated children with a respiratory infection were eligible. Using a structured approach, we implemented the PAWS guideline in a single paediatric intensive care unit. Evaluation included clinical (e.g., suction intervention appropriateness), implementation (e.g., acceptability), and cost outcomes (implementation costs). Associations between implementation of the PAWS guideline and appropriateness of endotracheal suction intervention use were investigated using generalised linear models. RESULTS: Data from 439 eligible suctions were included in the analysis. Following PAWS implementation, inappropriate endotracheal tube intervention use reduced from 99% to 58%, an absolute reduction (AR) of 41% (95% confidence interval [CI]: 25%, 56%). Reductions were most notable for open suction systems (AR: 48%; 95% CI: 30%, 65%), 0.9% sodium chloride use (AR: 23%; 95% CI: 8%, 38%) and presuction and postsuction manual bagging (38%; 95% CI: 16%, 60%, and 86%; 95% CI: 73%, 99%), respectively. Clinicians perceived PAWS as acceptable and suitable for use. CONCLUSIONS: Implementation of endotracheal tube suction appropriate use guidelines in a mixed paediatric intensive care unit was associated with a large reduction in inappropriate suction intervention use in paediatric patients with respiratory infections.


Asunto(s)
Respiración Artificial , Infecciones del Sistema Respiratorio , Niño , Humanos , Succión/métodos , Intubación Intratraqueal/efectos adversos , Cloruro de Sodio
14.
J Adv Nurs ; 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38037540

RESUMEN

AIM: This qualitative study aimed to identify nurses' and allied health professionals' perceptions and experiences of providing hospital-acquired pressure injury (HAPI) prevention in a paediatric tertiary hospital in Australia, as well as understand the perceived barriers and facilitators to preventing HAPI. DESIGN: A qualitative, exploratory study of hospital professionals was undertaken using semi-structured interviews between February 2022 and January 2023. METHODS: Two frameworks, the Capability, Opportunity and Motivation Model of Behaviour (COM-B) and the Theoretical Domains Framework (TDF), were used to give both theoretical and pragmatic guidance. Participants included 19 nursing and allied health professionals and data analysis was informed by the framework approach. RESULTS: Analysis revealed nine core themes regarding professionals' beliefs about the barriers and facilitators to HAPI prevention practices across seven TDF domains. Themes included HAPI prevention skills and education, family-centred care, automated feedback and prompts, allocation and access to equipment, everybody's responsibility, prioritizing patients and clinical demands, organizational expectations and support, integrating theory and reality in practice and emotional influence. CONCLUSION: These findings provide valuable insights into the barriers and facilitators that impact paediatric HAPI prevention and can help identify and implement strategies to enhance evidence-based prevention care and prevent HAPI in paediatric settings. IMPACT: Overcoming barriers through evidence-based interventions is essential to reduce HAPI cases, improve patient outcomes, and cut healthcare costs. The findings have practical implications, informing policy and practice for improved preventive measures, education, and staffing in paediatric care, ultimately benefiting patient well-being and reducing HAPIs. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution. The focus of the study is on healthcare professionals and their perspectives and experiences in preventing HAPIs in paediatric patients. Therefore, the involvement of patients or the public was not deemed necessary for achieving the specific research objectives.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38099826

RESUMEN

BACKGROUND: Implementing family-centered care (FCC) presents challenges to parental-healthcare provider partnership and collaboration in newborn care in neonatal intensive care units (NICUs). AIMS: To explore NICU nurses' perceptions of FCC (respect, collaboration, and support) during the COVID-19 pandemic and to compare these between nurses working in secondary and tertiary/higher care settings. METHODS: A multicenter, cross-sectional exploratory online survey design study was conducted to identify Thai NICU nurses' perceptions. The online survey of the Perceptions of Family-Centered Care-Staff (PFCC-S) was distributed via a Web page and professional networks between July and September 2022. RESULTS: Of the 187 survey respondents, most NICU nurses worked in the NICU for less than 16 years and were employed in tertiary care/higher care settings in southern Thailand. There was a significant difference in perceptions of support subscale between NICU nurses in secondary (mean: 3.32, SD ± 0.53) and tertiary/higher care settings (mean: 3.17, SD ± 0.46) (P < .05). CONCLUSION: Despite the challenges of the visitation restriction of COVID-19 in Thailand, nurses' perceptions of the value of FCC were maintained. RELEVANCE TO CLINICAL PRACTICE: Further research is recommended to investigate how FCC can be implemented where there is a lack of material and infrastructure resources and staff shortage.

16.
Cardiol Young ; : 1-7, 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37927298

RESUMEN

BACKGROUND: CHD is associated with considerable burden of care. Up to one-third of babies born with CHD require surgery or intervention during the first year of life with an associated increased risk of surgical site infection. Pediatric wound care is informed largely by adult data, with no national or international guidelines available. AIM: To examine pediatric cardiac surgical wound care practices reported by healthcare professionals Australia and New Zealand-wide. METHODS: A bi-national cross-sectional survey exploring pre-, intra- and post-operative wound practices was distributed using Exponential Non-Discriminative Snowball Sampling. Data were subject to descriptive analysis using SPSS Statistics 22.0. FINDINGS: Sixty-eight surveys representing all Australian and New Zealand pediatric cardiac surgical services were analyzed. Most respondents were experienced nurses. Pre-operative care varied greatly in practice and pharmaceutical agents used. Little consistency was reported for intra- and post-operative wound care. Nursing and medical staff shared responsibility for wound care. Wound photography was widely used, but only uploaded to electronic medical records by some. DISCUSSION: These results highlight that wound care management is largely informed at an institutional level. The many practices reported are likely to reflect a range of factors including cardiac condition complexity, surgery, prematurity, and the presence of scar tissue. The importance of a research and training program, which is multimodal, available, and reflective, is highlighted. CONCLUSION: These findings call for the establishment of a nurse-led program of research and education. The resultant suite of cardiac wound strategies could offer an effective and consistent pathway forward.

17.
Int Emerg Nurs ; 71: 101366, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37852059

RESUMEN

BACKGROUND: Peripheral intravenous catheters (PIVCs) are commonly used devices in emergency departments (EDs), and yet relatively little is known about factors influencing Australian clinicians' adherence to the national PIVC quality and safety Standard. AIMS: To explore attitudes and experiences of ED clinicians around PIVC insertion and care processes. METHODS: This study used an exploratory qualitative approach to analyse written responses to open-ended questions included in an online national (mixed data) survey. Snowballing methods were used to gather responses. Deductive analysis was used to analyse open-ended questions regarding practice and Standard adherence. RESULTS: There were 340 written responses, mainly from nurses in public EDs, who reported suboptimal practices regarding idle catheters, lack of patient participation in care, antecubital fossa insertion, multiple insertion attempts, inadequate site preparation, poor documentation and insufficient review of PIVC. The main factors inhibiting ED clinicians from adhering to the Standard includes inadequate knowledge, perceptions of infeasibility, disbelief in evidence, ambiguous responsibilities, habitual practice, insufficient training, lack of recognition of good practice and inadequate engagement. CONCLUSION: The factors that impact ED clinicians' PIVC Standard adherence are complex and multifactorial. Strategies and interventions are needed to facilitate the implementation of the Standard into daily practice and achieve sustainable behaviour change.


Asunto(s)
Cateterismo Periférico , Humanos , Australia , Encuestas y Cuestionarios , Cateterismo Periférico/métodos , Servicio de Urgencia en Hospital , Catéteres
18.
JAMA Pediatr ; 177(11): 1132-1140, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37695594

RESUMEN

Importance: Peripheral intravenous catheters (PIVCs) frequently fail during treatment causing therapy interruption, pain, recatheterization, and additional health care costs. Midline catheters (MCs) may improve functional dwell time and reduce failure compared with traditional PIVCs. Objective: To compare device failure of MCs with PIVCs. Design, Setting, and Participants: This was a pragmatic, randomized clinical superiority trial with an embedded internal pilot study conducted from July 2020 to May 2022. The study took place in a quaternary pediatric hospital in Brisbane, Queensland, Australia. Inclusion criteria were patients aged 1 to 18 years requiring peripherally compatible intravenous therapy for 4 days or longer. Interventions: Patients were randomly assigned 1:1 to receive a PIVC or MC, stratified by age (≤5 years, >5 years). One catheter was studied per patient. Main Outcomes and Measures: The primary outcome was all-cause device failure, defined as premature cessation of device function. Secondary outcomes included number of insertion attempts, insertion failure, pain (on insertion), procedural time, patient/parent satisfaction (with insertion), device dwell time, device complications during dwell time, additional vascular access devices required to complete treatment, clinician satisfaction (at removal), and health care costs. Results: Of the 128 patients randomly assigned to study groups, 127 patients (median [IQR] age, 7 [2-13] years; 71 male [56%]) had a device inserted, with 65 (51.2%) in the PIVC group and 62 (48.8%) in the MC group. All patients were included in the intention-to-treat analysis. Device failure was lower in patients in the MC group (10 [16.1%]) compared with those in the PIVC group (30 [46.2%]; odds ratio [OR], 0.22; 95% CI, 0.10-0.52; P <.001). MCs were associated with fewer insertion attempts (mean difference [MD], -0.3; 95% CI, -0.5 to 0; P = .04), increased dwell time (MD, 66.9 hours; 95% CI, 36.2-97.5 hours; P <.001), and fewer patients required additional vascular access devices to complete treatment in the MC group (4 [6.5%]) and PIVC group (19 [29.2%]; OR, 0.17; 95% CI, 0.05-0.52; P = .002). Compared with PIVCs, use of MCs was associated with greater patient (9.0 vs 7.1 of 10; P = .002) and parent (9.1 vs 8.2 of 10; P = .02) satisfaction and lower health care costs (AUS -$151.67 [US -$101.13] per person; 95% credible interval, AUS -$171.45 to -$131.90 [US -$114.20 to -$87.95]). Conclusions and Relevance: Findings suggest that MC insertion for patients requiring peripherally compatible intravenous therapy for 4 days or longer should be prioritized to reduce the resource intensive, expensive, and burdensome sequelae of device failure. Trial Registration: Australia New Zealand Clinical Trials Registry, ACTRN12620000724976.


Asunto(s)
Cateterismo Periférico , Adolescente , Niño , Preescolar , Humanos , Masculino , Australia , Cateterismo Periférico/efectos adversos , Catéteres , Falla de Equipo , Dolor/etiología , Proyectos Piloto , Femenino
19.
Br J Nurs ; 32(14): S22-S28, 2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37495404

RESUMEN

Ultrasound-guided insertion of peripheral intravenous catheters (PIVCs) is an alternative to traditional anatomical landmark-based insertion. However, data on its performance in paediatric patients of varying levels of difficult intravenous access are limited. The researchers hypothesise that ultrasound-guided PIVC insertion will increase first-attempt success compared with landmark technique. This randomised, parallel-group, single-centre, superiority trial commenced recruiting in July 2021, including hospitalised children (aged 0 (>37 weeks gestation) to 18 years) requiring a PIVC. It will recruit 180 children, stratified by degree of perceived difficulty, and centrally randomised into two groups (ratio 1:1). The primary outcome is first-attempt PIVC insertion success. Secondary outcomes include total number of PIVC insertion attempts, PIVC insertion failure, post-insertion complications, dwell time, patient/parent satisfaction, and healthcare costs. The current study will inform the superiority of ultrasound-guided PIVC insertion in comparison with landmark technique. Adoption by healthcare facilities might improve patient outcomes and decrease healthcare costs.


Asunto(s)
Cateterismo Periférico , Remoción de Dispositivos , Niño , Humanos , Cateterismo Periférico/métodos , Falla de Equipo , Satisfacción del Paciente , Ensayos Clínicos Controlados Aleatorios como Asunto , Ultrasonografía , Ultrasonografía Intervencional , Recién Nacido , Lactante , Preescolar , Adolescente
20.
Australas Emerg Care ; 26(4): 352-359, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37423812

RESUMEN

BACKGROUND: Ultrasound-guided peripheral intravenous catheter insertion has been identified as an effective method to improve the success rate of cannulation, thereby improving patient experience. However, learning this new skill is complex, and involves training clinicians from a variety of backgrounds. The aim of this study was to appraise and compare literature on educational methods in the emergency setting used to support ultrasound guided peripheral intravenous catheter insertion by different clinicians, and how effective these current methods are. REVIEW METHODS: A systematic integrative review was undertaken using Whittemore and Knafl's five stage approach. The Mixed Methods Appraisal Tool was used to assess the quality of the studies. RESULTS: Forty-five studies met the inclusion criteria, with five themes identified. These were: the variety of educational methods and approaches; the effectiveness of the different educational methods; barriers and facilitators of education; clinician competency assessments and pathways; clinician confidence assessment and pathways. CONCLUSIONS: This review demonstrates that a variety of educational methods are being used in successfully training emergency department clinicians in using ultrasound guidance for peripheral intravenous catheter insertion. Furthermore, this training has resulted in safer and more effective vascular access. However, it is evident that there is a lack of consistency of formalised education programs available. A standardised formal education program and increased availability of ultrasound machines in the emergency department will ensure consistent practices are maintained, retained, therefore leading to safer practice as well as more satisfied patients.


Asunto(s)
Aprendizaje , Ultrasonografía Intervencional , Humanos , Ultrasonografía Intervencional/métodos , Ultrasonografía , Servicio de Urgencia en Hospital , Catéteres
SELECCIÓN DE REFERENCIAS