Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rofo ; 186(3): 247-52, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23999779

RESUMEN

PURPOSE: To assess the benefit of C-arm CT for classification and procedural guidance during interventional therapy of endoleaks (EL) after endovascular repair (EVAR) of abdominal aortic aneurysms (AAA). MATERIALS AND METHODS: 12 patients with EL diagnosed with CT but undetermined EL classification (ELC) underwent DSA and transarterial contrast-enhanced C-arm CT. ELC (based on DSA, C-arm CT and CT) assessed during the angiographic procedure served as the standard of reference (SOR). Subsequently, ELC was assessed by a blinded second reader based on DSA or C-arm CT and compared to the SOR. In the case of an interventional procedure (n = 6), the added value of C-arm CT for procedure guidance was assessed retrospectively (1: essential, 2: helpful, 3: additional information without impact, 4: no additional information). RESULTS: The blinded reader classified 9/12 EL using DSA alone and 11/12 EL using C-arm CT alone. In one patient, the temporal resolution provided by DSA was essential to establish the diagnosis. In 6 patients, a type 2 EL without need for therapy was diagnosed. The remaining 6 patients showed EL that were treated immediately (type 1 EL, n = 4: 3 stent graft extensions and one angioplasty; type 2 EL, n = 1: translumbar embolization; type 3 EL, n = 1: sealing of a fabric tear). The information provided by C-arm CT was assessed to be essential in three patients and helpful in two. CONCLUSION: C-arm CT is an ideal adjunct to DSA. In our pilot study, it helped to localize and classify endoleaks more reliably than DSA alone.


Asunto(s)
Angiografía de Substracción Digital/métodos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Endofuga/diagnóstico por imagen , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Aneurisma de la Aorta Abdominal/complicaciones , Humanos , Imagen Multimodal/métodos , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica/métodos , Radiografía Abdominal/métodos , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
2.
Radiologe ; 49(9): 848-51, 2009 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-19697002

RESUMEN

Primary hyperaldosteronism is the most common curable cause of hypertension with a prevalence of up to 12% among patients with hypertension. Selective blood sampling from adrenal veins is considered the diagnostic gold standard. However, it is underutilized due to the high technical failure rate. The use of C-arm CT during the sampling procedure can reduce or even eliminate this failure rate. If adrenal vein sampling is augmented by native C-arm CT to check for the correct catheter position, the technical success rate increases substantially. General use of this technique will result in correct diagnosis and treatment for patients with primary hyperaldosteronism.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Glándulas Suprarrenales/diagnóstico por imagen , Aldosterona/sangre , Hiperaldosteronismo/sangre , Hiperaldosteronismo/diagnóstico por imagen , Flebografía/métodos , Punciones/métodos , Tomografía Computarizada por Rayos X/métodos , Análisis Químico de la Sangre/métodos , Femenino , Humanos , Hiperaldosteronismo/diagnóstico , Masculino , Persona de Mediana Edad , Radiografía Intervencional/métodos
3.
Langenbecks Arch Surg ; 394(3): 475-81, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19274468

RESUMEN

PURPOSE: To quantify the cooling effect of hepatic vessels on liver radiofrequency (RF) ablation ex situ. METHODS: Bipolar RF applicators (diameter = 1.8 mm, electrode length = 30 mm) were inserted parallel to perfused glass tubes (diameter = 5 and 10 mm; flow = 250-1,800 ml/min) at distances of 5 and 10 mm in porcine livers ex vivo. RF ablation was performed at 30 W/15 kJ. RF lesions were analyzed by measuring the maximum (r (max)) and minimum radius (r (min)) and the lesion area. RESULTS: Glass tubes without flow showed no influence on RF lesions, whereas perfused glass tubes had a significant cooling effect on lesions. r (min) was reduced to 50% at 5 mm applicator-to-vessel distance and the lesion area was reduced from 407 to 321 mm(2) (p < 0.001). There was no significant influence of glass tube diameter or flow volume on any of the analyzed parameters. CONCLUSIONS: Cooling effects of intrahepatic vessels could be simulated in an ex situ model. Cooling effects should be taken into account in RF ablation within 10 mm distance to major liver vessels regardless of blood flow volume or vessel diameter. Surgical RF ablation with temporary blood flow occlusion should be considered in such constellations.


Asunto(s)
Ablación por Catéter , Frío , Hígado/irrigación sanguínea , Animales , Técnicas In Vitro , Estadísticas no Paramétricas , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA