Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Phys Med Biol ; 68(20)2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37748504

RESUMEN

A subcommittee of the Netherlands Commission on Radiation Dosimetry (NCS) was initiated in 2018 with the task to update and extend a previous publication (NCS-15) on the quality assurance of treatment planning systems (TPS) (Bruinviset al2005). The field of treatment planning has changed considerably since 2005. Whereas the focus of the previous report was more on the technical aspects of the TPS, the scope of this report is broader with a focus on a department wide implementation of the TPS. New sections about education, automated planning, information technology (IT) and updates are therefore added. Although the scope is photon therapy, large parts of this report will also apply to all other treatment modalities. This paper is a condensed version of these guidelines; the full version of the report in English is freely available from the NCS website (http://radiationdosimetry.org/ncs/publications). The paper starts with the scope of this report in relation to earlier reports on this subject. Next, general aspects of the commissioning process are addressed, like e.g. project management, education, and safety. It then focusses more on technical aspects such as beam commissioning and patient modeling, dose representation, dose calculation and (automated) plan optimisation. The final chapters deal with IT-related subjects and scripting, and the process of updating or upgrading the TPS.

2.
EJNMMI Res ; 11(1): 95, 2021 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-34568982

RESUMEN

RATIONALE: PSMA-directed therapy for metastatic prostate cancer is gaining adoption as a treatment option. However, accumulation of 177Lu/225Ac-PSMA in the salivary glands remains a problem, with risk of dose-limiting xerostomia and potentially severe effect on the quality of life. Gustatory stimulation is an approach that has commonly been used in radioactive iodine therapy to reduce accumulation in the salivary glands. However, based on theoretical differences in biodistribution, it was hypothesized that this could potentially lead to adverse increased toxicity for PSMA-ligand therapy. The primary objective of this work was to determine if gustatory stimulation by eating an assortment of sweet/fatty/acidic foods during the biodistribution phase of [18F]DCFPyl could result in a clinically relevant (> 30%) change in the uptake of the tracer in the salivary glands. METHODS: 10 patients who already received a whole-body [18F]DCFPyl PET/CT scan for evaluation of prostate cancer, underwent a repeat (intervention) PET/CT scan within a month of the first (control) scan. During the intervention scan, patients chose from an assortment of sweet/fatty/acidic foods, which they then chewed and swallowed for a period of time starting 1 min before tracer administration to 10 min thereafter. Data from both scans were analyzed by placing VOIs on the major salivary glands and segmenting them using relative thresholds. RESULTS: A slight increase in PSMA uptake in the parotid glands was observed on the intervention scan when compared to the baseline scan (+ 7.1% SULmean and + 9.2% SULmax, p < 0.05). No significant difference in PSMA uptake in the submandibular glands was seen. CONCLUSIONS: Eating only slightly increases uptake of [18F]DCFPyl in the parotid glands. We nonetheless recommend refraining from gustatory stimulation during the administration and early biodistribution phase of radionuclide therapy with PSMA-ligands to reduce the risk of avoidable additional toxicity.

3.
EJNMMI Res ; 11(1): 25, 2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33710423

RESUMEN

RATIONALE: Salivary glands are highly perfused and express the prostate-specific membrane antigen (PSMA) receptor as well as the sodium-iodide symporter. As a consequence, treatment with 177Lu/225Ac-PSMA for prostate cancer or 131I for thyroid cancer leads to a high radiation dose in the salivary glands, and patients can be confronted with persistent xerostomia and reduced quality of life. Salivation can be inhibited using an antimuscarinic pharmaceutical, such as glycopyrronium bromide (GPB), which may also reduce perfusion. The primary objective of this work was to determine if inhibition with GPB could provide a considerable (> 30%) reduction in the accumulation of administered 123I or 68Ga-PSMA-11 in salivary glands. METHODS: Ten patients who already received a whole-body 68Ga-PSMA-11 PET/CT scan for (re)staging of prostate cancer underwent a repeat PET/CT scan with tracer administration at 90 min after intravenous injection of 0.2 mg GPB. Four patients in follow-up after thyroid cancer, who had been treated with one round of ablative 131I therapy with curative intent and had no signs of recurrence, received 123I planar scintigraphy at 4 h after tracer administration without GPB and a repeated scan at least one week later, with tracer administration at 30 min after intramuscular injection of 0.4 mg GPB. Tracer uptake in the salivary glands was quantified on PET and scintigraphy, respectively, and values with and without GPB were compared. RESULTS: No significant difference in PSMA uptake in the salivary glands was seen without or with GPB (Mean SULmean parotid glands control 5.57, intervention 5.72, p = 0.50. Mean SULmean submandibular glands control 6.25, intervention 5.89, p = 0.12). Three out of 4 patients showed increased 123I uptake in the salivary glands after GPB (Mean counts per pixel control 8.60, intervention 11.46). CONCLUSION: Muscarinic inhibition of salivation with GPB did not significantly reduce the uptake of PSMA-ligands or radioiodine in salivary glands, and can be dismissed as a potential strategy to reduce toxicity from radionuclide therapies.

4.
Eur J Nucl Med Mol Imaging ; 48(12): 3762-3775, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33687522

RESUMEN

Radiation therapy is an effective treatment modality for a variety of cancers. Despite several advances in delivery techniques, its main drawback remains the deposition of dose in normal tissues which can result in toxicity. Common practices of evaluating toxicity, using questionnaires and grading systems, provide little underlying information beyond subjective scores, and this can limit further optimization of treatment strategies. Nuclear medicine imaging techniques can be utilised to directly measure regional baseline function and function loss from internal/external radiation therapy within normal tissues in an in vivo setting with high spatial resolution. This can be correlated with dose delivered by radiotherapy techniques to establish objective dose-effect relationships, and can also be used in the treatment planning step to spare normal tissues more efficiently. Toxicity in radionuclide therapy typically occurs due to undesired off-target uptake in normal tissues. Molecular imaging using diagnostic analogues of therapeutic radionuclides can be used to test various interventional protective strategies that can potentially reduce this normal tissue uptake without compromising tumour uptake. We provide an overview of the existing literature on these applications of nuclear medicine imaging in diverse normal tissue types utilising various tracers, and discuss its future potential.


Asunto(s)
Braquiterapia , Neoplasias , Medicina Nuclear , Diagnóstico por Imagen , Humanos , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Planificación de la Radioterapia Asistida por Computador
5.
Clin Oncol (R Coll Radiol) ; 28(12): e206-e215, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27692741

RESUMEN

AIMS: Functional imaging with positron emission tomography/computed tomography (PET/CT) and multiparametric magnetic resonance (mpMR) is increasingly applied for radiotherapy purposes. However, evidence and experience are still limited, and this may lead to clinically relevant differences in accessibility, interpretation and decision making. We investigated the current patterns of care in functional imaging for radiotherapy in the Netherlands in a care evaluation study. MATERIALS AND METHODS: The availability of functional imaging in radiotherapy centres in the Netherlands was evaluated; features available in >80% of academic and >80% of non-academic centres were considered standard of care. The impact of functional imaging on clinical decision making was evaluated using case questionnaires on lung, head/neck, breast and prostate cancer, with multiple-choice questions on primary tumour delineation, nodal involvement, distant metastasis and incidental findings. Radiation oncologists were allowed to discuss cases in a multidisciplinary approach. Ordinal answers were evaluated by median and interquartile range (IQR) to identify the extent and variability of clinical impact; additional patterns were evaluated descriptively. RESULTS: Information was collected from 18 radiotherapy centres in the Netherlands (all except two). PET/CT was available for radiotherapy purposes to 94% of centres; 67% in the treatment position and 61% with integrated planning CT. mpMR was available to all centres; 61% in the treatment position. Technologists collaborated between departments to acquire PET/CT or mpMR for radiotherapy in 89%. All sites could carry out image registration for target definition. Functional imaging generally showed a high clinical impact (average median 4.3, scale 1-6) and good observer agreement (average IQR 1.1, scale 0-6). However, several issues resulted in ignoring functional imaging (e.g. positional discrepancies, central necrosis) or poor observer agreement (atelectasis, diagnostic discrepancies, conformation strategies). CONCLUSIONS: Access to functional imaging with PET/CT and mpMR for radiotherapy purposes, with collaborating technologists and multimodal delineation, can be considered standard of care in the Netherlands. For several specific clinical situations, the interpretation of images may benefit from further standardisation.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias/radioterapia , Países Bajos , Planificación de la Radioterapia Asistida por Computador/métodos , Encuestas y Cuestionarios
6.
J Med Imaging Radiat Oncol ; 54(3): 256-63, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20598014

RESUMEN

The aim of this study is to investigate to what extent IMRT can decrease the dose to the organs at risk in bladder cancer treatment compared with conformal treatment while making separate treatment plans for the elective field and the boost. Special attention is paid to sparing small intestines. Twenty patients who were treated with the field-in-field technique (FiF) were re-planned with intensity modulated radiotherapy (IMRT) using five and seven beams, respectively. Separate treatment plans were made for the elective field (including the pelvic lymph nodes) and the boost, which enables position correction for bone and tumour separately. The prescribed dose was 40 Gy to the elective field and 55 or 60 Gy to the planning target volume (PTV). For bladder and rectum, V(45Gy) and V(55Gy) were compared, and for small intestines, V(25Gy) and V(40Gy.) The dose distribution with IMRT conformed better to the shape of the target. There was no significant difference between the techniques in dose to the healthy bladder. The median V(40Gy) of the small intestines decreased from 114 to 66 cc (P = 0.001) with five beam IMRT, and to 55 cc (P = 0.001) with seven beam IMRT compared with FiF. V(45Gy) for rectum decreased from 34.2% to 17.5% (P = 0.004) for both five and seven beam plans, while V(55Gy) for rectum remained the same. With IMRT, a statistically significant dose decrease to the small intestines can be achieved while covering both tumour and elective PTV adequately.


Asunto(s)
Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Neoplasias de la Vejiga Urinaria/radioterapia , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Resultado del Tratamiento
7.
Int J Hyperthermia ; 23(4): 395-411, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17558739

RESUMEN

INTRODUCTION: This study compared simulated temperature distributions of intraluminal heating devices, concerning penetration and homogeneity. A hot water balloon, a 434-MHz monopole and a 915-MHz dipole antenna, both with incorporated cooling, and a 27-MHz applicator were investigated. METHODS: The hot water balloon had an inlet temperature of 45 degrees C and a flow rate of 7.85 ml s(-1). The cooling water and air had a temperature of 41 degrees C and 37 degrees C and a flow rate of 5.89 ml s(-1) and 1.8 l s(-1), respectively. A 27-MHz applicator consisting of one or two electrode(s) was modelled to demonstrate axial steering for inhomogeneous tissue properties. Calculated power distributions were scaled to a total power of 10 W in tissue before the corresponding temperature distributions were calculated. RESULTS: The hot water balloon and the 27-MHz device showed a thermal penetration depth of approximately 4 and approximately 10 mm, respectively. The penetration depths of the 434- and 915-MHz applicators were comparable: approximately 10 and approximately 16 mm with water and air cooling, respectively. With the 27-MHz applicator, spatial steering was applied to minimize temperature gradients along the applicator. The 434- and 915-MHz antennas have no steering possibilities. The temperature distribution of the hot water balloon is not affected by inhomogeneous dielectric properties, only slightly by inhomogeneous perfusion. CONCLUSION: A hot water balloon is useful for heating tumours with a limited infiltration in tissue, while a 27-MHz device has the best potential to realize a homogeneous temperature distribution in larger tumours.


Asunto(s)
Frío , Calor , Hipertermia Inducida/métodos , Hipertermia Inducida/enfermería , Electrodos , Diseño de Equipo , Humanos , Modelos Teóricos
8.
Int J Hyperthermia ; 22(5): 375-89, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16891240

RESUMEN

BACKGROUND: In the Academic Medical Center (AMC) Amsterdam, locoregional hyperthermia for oesophageal tumours is applied using the 70 MHz AMC-4 phased array system. Due to the occurrence of treatment-limiting hot spots in normal tissue and systemic stress at high power, the thermal dose achieved in the tumour can be sub-optimal. The large number of degrees of freedom of the heating device, i.e. the amplitudes and phases of the antennae, makes it difficult to avoid treatment-limiting hot spots by intuitive amplitude/phase steering. AIM: Prospective hyperthermia treatment planning combined with high resolution temperature-based optimization was applied to improve hyperthermia treatment of patients with oesophageal cancer. METHODS: All hyperthermia treatments were performed with 'standard' clinical settings. Temperatures were measured systemically, at the location of the tumour and near the spinal cord, which is an organ at risk. For 16 patients numerically optimized settings were obtained from treatment planning with temperature-based optimization. Steady state tumour temperatures were maximized, subject to constraints to normal tissue temperatures. At the start of 48 hyperthermia treatments in these 16 patients temperature rise (DeltaT) measurements were performed by applying a short power pulse with the numerically optimized amplitude/phase settings, with the clinical settings and with mixed settings, i.e. numerically optimized amplitudes combined with clinical phases. The heating efficiency of the three settings was determined by the measured DeltaT values and the DeltaT-ratio between the DeltaT in the tumour (DeltaToes) and near the spinal cord (DeltaTcord). For a single patient the steady state temperature distribution was computed retrospectively for all three settings, since the temperature distributions may be quite different. To illustrate that the choice of the optimization strategy is decisive for the obtained settings, a numerical optimization on DeltaT-ratio was performed for this patient and the steady state temperature distribution for the obtained settings was computed. RESULTS: A higher DeltaToes was measured with the mixed settings compared to the calculated and clinical settings; DeltaTcord was higher with the mixed settings compared to the clinical settings. The DeltaT-ratio was approximately 1.5 for all three settings. These results indicate that the most effective tumour heating can be achieved with the mixed settings. DeltaT is proportional to the Specific Absorption Rate (SAR) and a higher SAR results in a higher steady state temperature, which implies that mixed settings are likely to provide the most effective heating at steady state as well. The steady state temperature distributions for the clinical and mixed settings, computed for the single patient, showed some locations where temperatures exceeded the normal tissue constraints used in the optimization. This demonstrates that the numerical optimization did not prescribe the mixed settings, because it had to comply with the constraints set to the normal tissue temperatures. However, the predicted hot spots are not necessarily clinically relevant. Numerical optimization on DeltaT-ratio for this patient yielded a very high DeltaT-ratio ( approximately 380), albeit at the cost of excessive heating of normal tissue and lower steady state tumour temperatures compared to the conventional optimization. CONCLUSION: Treatment planning can be valuable to improve hyperthermia treatments. A thorough discussion on clinically relevant objectives and constraints is essential.


Asunto(s)
Neoplasias Esofágicas/terapia , Hipertermia Inducida/métodos , Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/radioterapia , Adenocarcinoma/terapia , Análisis de Varianza , Antineoplásicos/uso terapéutico , Carcinoma de Células Escamosas/tratamiento farmacológico , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/terapia , Simulación por Computador , Diatermia/métodos , Neoplasias Esofágicas/tratamiento farmacológico , Neoplasias Esofágicas/radioterapia , Humanos , Dosis Máxima Tolerada , Análisis Multivariante , Terapia Neoadyuvante , Estudios Prospectivos , Terapia Asistida por Computador , Tomografía Computarizada por Rayos X
9.
Phys Med Biol ; 50(13): 3127-41, 2005 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-15972985

RESUMEN

In regional hyperthermia, optimization techniques are valuable in order to obtain amplitude/phase settings for the applicators to achieve maximal tumour heating without toxicity to normal tissue. We implemented a temperature-based optimization technique and maximized tumour temperature with constraints on normal tissue temperature to prevent hot spots. E-field distributions are the primary input for the optimization method. Due to computer limitations we are restricted to a resolution of 1 x 1 x 1 cm3 for E-field calculations, too low for reliable treatment planning. A major problem is the fact that hot spots at low-resolution (LR) do not always correspond to hot spots at high-resolution (HR), and vice versa. Thus, HR temperature-based optimization is necessary for adequate treatment planning and satisfactory results cannot be obtained with LR strategies. To obtain HR power density (PD) distributions from LR E-field calculations, a quasi-static zooming technique has been developed earlier at the UMC Utrecht. However, quasi-static zooming does not preserve phase information and therefore it does not provide the HR E-field information required for direct HR optimization. We combined quasi-static zooming with the optimization method to obtain a millimetre resolution temperature-based optimization strategy. First we performed a LR (1 cm) optimization and used the obtained settings to calculate the HR (2 mm) PD and corresponding HR temperature distribution. Next, we performed a HR optimization using an estimation of the new HR temperature distribution based on previous calculations. This estimation is based on the assumption that the HR and LR temperature distributions, though strongly different, respond in a similar way to amplitude/phase steering. To verify the newly obtained settings, we calculate the corresponding HR temperature distribution. This method was applied to several clinical situations and found to work very well. Deviations of this estimation method for the AMC-4 system were typically smaller than 0.2 degrees C in the volume of interest, which is accurate enough for treatment planning purposes.


Asunto(s)
Neoplasias Esofágicas/terapia , Hipertermia Inducida/métodos , Microondas/uso terapéutico , Modelos Biológicos , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Termografía/métodos , Carga Corporal (Radioterapia) , Temperatura Corporal , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Neoplasias Esofágicas/fisiopatología , Humanos , Dosificación Radioterapéutica , Efectividad Biológica Relativa
10.
Int J Hyperthermia ; 19(5): 481-97, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12944164

RESUMEN

A study was performed on regional hyperthermia for patients with locally advanced prostate carcinoma. The primary objective was to analyse the thermometry data with an emphasis on the possibility of replacing invasive thermometry by tumour-related intra-luminal thermometry. Fourteen patients were treated with a combination of conformal external beam radiotherapy (70 Gy) and hyperthermia. Hyperthermia was delivered using the Coaxial TEM system, one treatment per week, to a total of five treatments. Thermometry was performed in bladder, urethra, rectum and esophagus. Invasive thermometry in the prostate was carried out during one or two treatments for each patient by placing transperineally a central and a peripheral catheter. Heterogeneous temperature distributions were measured in the prostate. The mean average invasive temperature range was 1.1 degrees C. Due to the temperature heterogeneity and a limited number of thermometry sensors (mean 7, range 2-13), large variability between treatments and patients existed regarding achieved temperatures and dose. The mean invasive T90 was 40.2 +/- 0.6 degrees C and T50 was 40.8 +/- 0.6 degrees C. The mean Cum min T90>40.5 degrees C per treatment was 22 (range 0-50). Importantly, intra-luminal temperatures did not reliably predict invasively measured temperatures. Invasive thermometry, therefore, remains compulsory to calculate a thermal dose for an individual patient. Changes in temperature during treatment, measured by the urethral sensors, corresponded well with changes in temperature measured by the individual invasive sensors. Similar comparison of rectal temperature changes with intra-prostatic temperature changes was not as predictive. The similarity in temperature changes between the urethral and interstial sites, suggests that urethral temperatures are sufficient for treatment optimization. The SAR profile did not correspond with the temperature profile indicating heterogeneous perfusion. Although regional hyperthermia in combination with external beam radiotherapy for locally advanced prostate carcinoma is clinically feasible, the question on the importance of invasive thermometry remains.


Asunto(s)
Hipertermia Inducida/métodos , Neoplasias de la Próstata/radioterapia , Radioterapia Conformacional , Termómetros , Anciano , Temperatura Corporal , Terapia Combinada , Esófago , Estudios de Factibilidad , Calor , Humanos , Masculino , Persona de Mediana Edad , Recto , Uretra
11.
Int J Hyperthermia ; 19(1): 58-73, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12519712

RESUMEN

Capacitively coupled hyperthermia devices are widely in use, mainly in Asian countries. In this paper, a comprehensive treatment planning system, including a Specific Absorption Rate (SAR) and thermal model for capacitively coupled hyperthermia, is described and demonstrated using a heterogeneous patient model. In order to accurately model a hyperthermia treatment, simulation at high resolution is mandatory. Using the quasi-static approximation, the electromagnetic problem can be solved at high resolution with acceptable computational effort. The validity of the quasi-static approximation is demonstrated by comparing the Maxwell solution of a phantom problem to the quasi-static approximation. Modelling of capacitive hyperthermia of the prostate reveals the difficulty of heating deep-seated tumours in the pelvic area. Comparison of the SAR distribution in the heterogeneous patient model and a patient shaped agar phantom shows a shielding effect of the pelvic bone and the influence of the fat-muscle distribution. It is shown that evaluation of capacitive hyperthermia with agar phantoms leads to overly optimistic conclusions. Therapeutic relevant tumour temperatures can only be obtained by permitting temperature extrema in normal tissue. This concurs with clinical practice, where treatment-limiting hot spots restrict the tumour temperature. It is demonstrated that the use of very cold overlay bolus bags has only a very superficial effect. The presented model can be used for individual treatment planning and optimization, for the evaluation of capacitive applicator modifications and comparison with other devices.


Asunto(s)
Hipertermia Inducida , Modelos Biológicos , Neoplasias Pélvicas/terapia , Terapia Asistida por Computador/métodos , Campos Electromagnéticos , Etnicidad , Humanos , Fantasmas de Imagen , Somatotipos , Termografía
12.
Int J Hyperthermia ; 19(6): 655-63, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14756454

RESUMEN

In the application of regional hyperthermia, optimization of the temperature distribution remains necessary. One of the tools that might be used is a modest increase in the systemic temperature to diminish cooling by blood perfusion. This study investigates (1) if it is feasible to increase the systemic temperature by applying other cooling strategies, without inducing unacceptable systemic stress, and (2) whether a rise in systemic temperature results in improvement of tumour temperatures. Eleven patients with locally advanced cervical carcinoma and 12 patients with locally advanced prostate carcinoma were treated with our Coaxial TEM regional hyperthermia system. In this system, the temperature of the open water bolus can be easily adjusted. Two cooling methods were applied alternately, one with a relatively low water temperature (method A), the other with a higher water bolus temperature in combination with extensive head/chest cooling by a hand shower (method B). Method B resulted in significantly higher systemic temperatures, for both patient groups separately (0.8, respectively, 0.5 degrees C) and for the total patient group (0.7 degrees C). Additionally, all tumour index temperatures were higher. For the combined group (for T50: 0.4 degrees C) and for the cervix group (for T50: 0.7 degrees C), it reached statistical significance. The raise in core temperature led to a significantly higher increase in heart rate. For the group of cervix patients, higher systemic temperatures resulted in more treatment-limiting systemic stress. For the prostate patients, systemic stress was not an important issue. Since the raise in systemic temperature did not influence the overall tolerance of treatment, method B could be applied to this group. However, the increases in tumour temperatures were small, and potential hazards of systemic temperature increase should be considered.


Asunto(s)
Hipertermia Inducida/efectos adversos , Hipertermia Inducida/métodos , Neoplasias de la Próstata/terapia , Neoplasias del Cuello Uterino/terapia , Adulto , Anciano , Temperatura Corporal , Frío , Femenino , Frecuencia Cardíaca , Calor , Humanos , Masculino , Persona de Mediana Edad , Estrés Fisiológico/etiología
13.
Int J Hyperthermia ; 19(6): 598-616, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14756451

RESUMEN

Local pain is a major limiting factor in regional hyperthermia treatment with radiative applicators. Absorbing structures, consisting of agar bound saline water, have been used successfully to reduce peripheral hot spots. However, both clinical experience and simulation results indicate a SAR elevation in the tissue under the edges of the absorber block. This paper investigates the effect of modification of shape, position and spatial composition of the absorber blocks on the central attenuating effect and the SAR elevating effect at the edges. A selection from a set of five options is made based on simulations with a phantom and a single ring dipole applicator. The simulations have been performed with the FDTD core of the regional hyperthermia treatment planning system. It is shown that tapering of the absorber edge and introduction of a water layer between the absorber and the skin can reduce the edge effect in the superficial fat layer by approximately 50% with respect to a rectangular absorber. A further reduction of 15% can be obtained by an absorber with an appropriate gradient of its conductivity in the direction of the dominant E-field. The modified absorbers produce a central attenuating effect comparable to the rectangular type. The use of a water layer type and a sigma gradient type absorber is also analysed in a patient anatomy, both in the dipole ring applicator, operating at 70 MHz, as well as in a three ring Cavity Slot (CS) applicator, operating at 150 MHz. The mutual influence of phase-amplitude steering and the application of absorbers is investigated in the CS applicator. It appears that absorbers have a significant influence on the interference pattern in the patient model, possibly causing substantial reduction of the SAR value in the tumour and limiting the possibility of ad hoc application of absorbers. Re-optimization can only partly cancel this effect. Local SAR reduction by phase-amplitude control alone can match or improve the effect obtained with modified absorbers.


Asunto(s)
Simulación por Computador , Hipertermia Inducida/métodos , Modelos Biológicos , Absorción , Tejido Adiposo , Huesos , Humanos , Agua
14.
Phys Med Biol ; 47(10): 1827-35, 2002 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-12069097

RESUMEN

SAR distributions in a healthy female adult head as a result of a radiating vertical dipole antenna (frequency 915 MHz) representing a hand-held mobile phone have been computed for three different resolutions: 2 mm, 1 mm and 0.4 mm. The extremely high resolution of 0.4 mm was obtained with our quasistatic zooming technique, which is briefly described in this paper. For an effectively transmitted power of 0.25 W, the maximum averaged SAR values in both cubic- and arbitrary-shaped volumes are, respectively, about 1.72 and 2.55 W kg(-1) for 1 g and 0.98 and 1.73 W kg(-1) for 10 g of tissue. These numbers do not vary much (<8%) for the different resolutions, indicating that SAR computations at a resolution of 2 mm are sufficiently accurate to describe the large-scale distribution. However, considering the detailed SAR pattern in the head, large differences may occur if high-resolution computations are performed rather than low-resolution ones. These deviations are caused by both increased modelling accuracy and improved anatomical description in higher resolution simulations. For example, the SAR profile across a boundary between tissues with high dielectric contrast is much more accurately described at higher resolutions. Furthermore, low-resolution dielectric geometries may suffer from loss of anatomical detail, which greatly affects small-scale SAR distributions. Thus. for strongly inhomogeneous regions high-resolution SAR modelling is an absolute necessity.


Asunto(s)
Teléfono Celular , Cabeza/efectos de la radiación , Adulto , Femenino , Humanos , Modelos Anatómicos , Fantasmas de Imagen , Programas Informáticos
15.
Int J Hyperthermia ; 18(2): 104-16, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-11926189

RESUMEN

Recent development of quasistatic zooming has enabled the computation of mm-resolution SAR distributions within reasonable computation times. These high-resolution SAR distributions proved to be completely dissimilar from the cm-resolution distributions. To study the impact of high-resolution SAR modelling on regional hyperthermia treatment planning (HTP), a conventional, low-resolution treatment plan is compared to an high-resolution plan. This comparison shows that the high-resolution plan yields totally different SAR and temperature distributions when compared to the conventional plan. Both SAR and temperature maxima predicted by the low-resolution plan are not predicted by the high-resolution plan and, even worse, the low-resolution plan fails to predict maxima that are predicted by the high-resolution plan. Furthermore, it appears that small-scale SAR maxima can result in temperature maxima which may cause treatment-limiting hot spots. These small-scale SAR maxima appear to be highly determined by the dielectric geometry of the patient. This demonstrates the need for an accurate, high-resolution description of this dielectric geometry. Moreover, it suggests that it may be very difficult to reduce potential treatment-limiting hot spots in clinical practice. This study demonstrates the need for high-resolution regional hyperthermia treatment planning.


Asunto(s)
Hipertermia Inducida , Terapia Asistida por Computador , Tomografía Computarizada por Rayos X
16.
Phys Med Biol ; 46(7): 1885-903, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11474932

RESUMEN

In this study we present a design for a multi-frequency microwave radiometer aimed at prolonged monitoring of deep brain temperature in newborn infants and suitable for use during hypothermic neural rescue therapy. We identify appropriate hardware to measure brightness temperature and evaluate the accuracy of the measurements. We describe a method to estimate the tissue temperature distribution from measured brightness temperatures which uses the results of numerical simulations of the tissue temperature as well as the propagation of the microwaves in a realistic detailed three-dimensional infant head model. The temperature retrieval method is then used to evaluate how the statistical fluctuations in the measured brightness temperatures limit the confidence interval for the estimated temperature: for an 18 degrees C temperature differential between cooled surface and deep brain we found a standard error in the estimated central brain temperature of 0.75 degrees C. Evaluation of the systematic errors arising from inaccuracies in model parameters showed that realistic deviations in tissue parameters have little impact compared to uncertainty in the thickness of the bolus between the receiving antenna and the infant's head or in the skull thickness. This highlights the need to pay particular attention to these latter parameters in future practical implementation of the technique.


Asunto(s)
Temperatura Corporal , Encéfalo/patología , Microondas , Radiometría/instrumentación , Radiometría/métodos , Temperatura , Humanos , Recién Nacido , Modelos Estadísticos , Modelos Teóricos
17.
Phys Med Biol ; 46(7): 1919-35, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11474934

RESUMEN

Recently published results confirm the positive effect of regional hyperthermia combined with external radiotherapy on pelvic tumours. Several studies have been published on the improvement of RF annular array applicator systems with dipoles and a closed water bolus. This study investigates the performance of a next-generation applicator system for regional hyperthermia with a multi-ring annular array of antennas and an open water bolus. A cavity slot antenna is introduced to enhance the directivity and reduce mutual coupling between the antennas. Several design parameters, i.e. dimensions, number of antennas and operating frequency, have been evaluated using several patient models. Performance indices have been defined to evaluate the effect of parameter variation on the specific absorption rate (SAR) distribution. The performance of the new applicator type is compared with the Coaxial TEM. Operating frequency appears to be the main parameter with a positive influence on the performance. A SAR increase in tumour of 1.7 relative to the Coaxial TEM system can be obtained with a three-ring, six-antenna per ring cavity slot applicator operating at 150 MHz.


Asunto(s)
Hipertermia Inducida/instrumentación , Hipertermia Inducida/métodos , Neoplasias Pélvicas/radioterapia , Neoplasias Pélvicas/terapia , Radioterapia/instrumentación , Radioterapia/métodos , Femenino , Humanos , Masculino , Modelos Estadísticos , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/terapia , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/terapia , Agua
18.
Phys Med Biol ; 46(5): 1539-51, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11384069

RESUMEN

Due to current computer limitations, regional hyperthermia treatment planning (HTP) is practically limited to a resolution of 1 cm, whereas a millimetre resolution is desired. Using the centimetre resolution E-field distribution, computed with, for example, the finite-difference time-domain (FDTD) method and the millimetre resolution patient anatomy it is possible to obtain a millimetre resolution SAR distribution in a volume of interest (VOI) by means of quasistatic zooming. To compute the required low-resolution E-field distribution, a low-resolution dielectric geometry is needed which is constructed by down-scaling the millimetre resolution dielectric geometry. In this study we have investigated which down-scaling technique results in a dielectric geometry that yields the best low-resolution E-field distribution as input for quasistatic zooming. A segmented 2 mm resolution CT data set of a patient has been down-scaled to 1 cm resolution using three different techniques: 'winner-takes-all', 'volumetric averaging' and 'anisotropic volumetric averaging'. The E-field distributions computed for those low-resolution dielectric geometries have been used as input for quasistatic zooming. The resulting zoomed-resolution SAR distributions were compared with a reference: the 2 mm resolution SAR distribution computed with the FDTD method. The E-field distribution for both a simple phantom and the complex partial patient geometry down-scaled using 'anisotropic volumetric averaging' resulted in zoomed-resolution SAR distributions that best approximate the corresponding high-resolution SAR distribution (correlation 97, 96% and absolute averaged difference 6, 14% respectively).


Asunto(s)
Hipertermia Inducida , Fantasmas de Imagen , Terapia Asistida por Computador , Anisotropía , Simulación por Computador , Humanos , Procesamiento de Imagen Asistido por Computador , Electricidad Estática
19.
Int J Hyperthermia ; 17(3): 240-57, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11347729

RESUMEN

Local pain is the main factor that limits regional hyperthermia treatment. Using the SAR model of the regional hyperthermia treatment planning system, the capability of absorbing blocks to reduce peripheral hot spots was investigated. The effect of rectangular absorbers of various size and salinity on an elliptical phantom in the Coaxial TEM was evaluated. The computed results were compared with SAR values measured in the phantom. Absorbers of 9 x 9 x 4 cm3 and a salinity of 18 gram l(-1) provide a SAR reduction in the muscle equivalent material, centrally under the absorber of at least 50% at a depth of up to 3 cm. The effect on the central (i.e. tumour) region is less than 20%. Larger absorbers have a more global effect and cause more attenuation in the central region. The attenuating effect depends strongly on the thickness of the fat layer between muscle and absorber. More than 2 cm fat limits the effective use of absorbers. Absorbers can induce a significant increase of SAR in muscle and fat near their edges. This effect also depends on absorber size and salinity and the thickness of the fat layer. The effect of an absorber was also evaluated with a patient anatomy, yielding results in agreement with the phantom experiments.


Asunto(s)
Hipertermia Inducida , Humanos , Modelos Anatómicos
20.
Int J Hyperthermia ; 17(3): 207-20, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11347727

RESUMEN

A flexible and fast regional hyperthermia treatment planning system for the Coaxial TEM System has been devised and is presented. Using Hounsfield Unit based thresholding and manually outlining of the tumour, a 40 cm CT data set (slice thickness 5 mm) is segmented and down scaled to a resolution of 1 cm, requiring only 30 min. The SAR model is based on the finite-difference time-domain (FDTD) method. The number of time steps to achieve numerical stability has been determined and was found to be 7000. Various optimizations of the SAR model have been applied, resulting in a relatively short computation time of 3.7 h (memory requirements 121 MB) on a Pentium III, 450 MHz standard personal computer, running GNU/Linux. The model has been validated using absolute value(Ez) measurements in a standard phantom inserted in the Coaxial TEM Applicator under different conditions and a good agreement was found. Hyperthermia treatment planning in combination with the homemade visualization tools have provided much insight in the regional hyperthermia treatment with the Coaxial TEM Applicator.


Asunto(s)
Hipertermia Inducida , Campos Electromagnéticos , Estudios de Evaluación como Asunto , Análisis de Fourier , Humanos , Masculino , Modelos Anatómicos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/terapia , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA