Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 16(12): e0260894, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34936659

RESUMEN

BACKGROUND: Performance of the SD Biosensor saliva antigen rapid test was evaluated at a large designated testing site in non-hospitalized patients, with or without symptoms. METHOD: All eligible people over 18 years of age presenting for a booked appointment at the designated SARS-CoV-2 testing site were approached for inclusion and enrolled following verbal informed consent. One nasopharyngeal swab was taken to carry out the default antigen rapid test from which the results were reported back to the patient and one saliva sample was self-taken according to verbal instruction on site. This was used for the saliva antigen rapid test, the RT-PCR and for virus culture. Sensitivity of the saliva antigen rapid test was analyzed in two ways: i, compared to saliva RT-PCR; and ii, compared to virus culture of the saliva samples. Study participants were also asked to fill in a short questionnaire stating age, sex, date of symptom onset. Recommended time of ≥30mins since last meal, drink or cigarette if applicable was also recorded. The study was carried out in February-March 2021 for 4 weeks. RESULTS: We could include 789 people with complete records and results. Compared to saliva RT-PCR, overall sensitivity and specificity of the saliva antigen rapid test was 66.1% and 99.6% which increased to 88.6% with Ct ≤30 cutoff. Analysis by days post onset did not result in higher sensitivities because the large majority of people were in the very early phase of disease ie <3 days post onset. When breaking down the data for symptomatic and asymptomatic individuals, sensitivity ranged from 69.2% to 50% respectively, however the total number of RT-PCR positive asymptomatic participants was very low (n = 5). Importantly, almost all culture positive samples were detected by the rapid test. CONCLUSION: Overall, the potential benefits of saliva antigen rapid test, could outweigh the lower sensitivity compared to nasopharyngeal antigen rapid test in a comprehensive testing strategy, especially for home/self-testing and in vulnerable populations like elderly, disabled or children where in intrusive testing is either not possible or causes unnecessary stress.


Asunto(s)
Técnicas Biosensibles/métodos , Prueba Serológica para COVID-19/métodos , Saliva/virología , Adolescente , Adulto , Anciano , COVID-19/diagnóstico , COVID-19/etiología , Portador Sano/virología , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Sensibilidad y Especificidad , Adulto Joven
2.
BMJ ; 374: n1676, 2021 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-34315770

RESUMEN

OBJECTIVE: To assess the diagnostic test accuracy of two rapid antigen tests in asymptomatic and presymptomatic close contacts of people with SARS-CoV-2 infection on day 5 after exposure. DESIGN: Prospective cross sectional study. SETTING: Four public health service covid-19 test sites in the Netherlands. PARTICIPANTS: 4274 consecutively included close contacts (identified through test-and-trace programme or contact tracing app) aged 16 years or older and asymptomatic for covid-19 when requesting a test. MAIN OUTCOME MEASURES: Sensitivity, specificity, and positive and negative predictive values of Veritor System (Beckton Dickinson) and Biosensor (Roche Diagnostics) rapid antigen tests, with reverse-transcriptase polymerase chain reaction (RT-PCR) testing as reference standard. The viral load cut-off above which 95% of people with a positive RT-PCR test result were virus culture positive was used as a proxy of infectiousness. RESULTS: Of 2678 participants tested with Veritor, 233 (8.7%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 149 were also detected by the rapid antigen test (sensitivity 63.9%, 95% confidence interval 57.4% to 70.1%). Of 1596 participants tested with Biosensor, 132 (8.3%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 83 were detected by the rapid antigen test (sensitivity 62.9%, 54.0% to 71.1%). In those who were still asymptomatic at the time of sampling, sensitivity was 58.7% (51.1% to 66.0%) for Veritor (n=2317) and 59.4% (49.2% to 69.1%) for Biosensor (n=1414), and in those who developed symptoms were 84.2% (68.7% to 94.0%; n=219) for Veritor and 73.3% (54.1% to 87.7%; n=158) for Biosensor. When a viral load cut-off was applied for infectiouness (≥5.2 log10 SARS-CoV-2 E gene copies/mL), the overall sensitivity was 90.1% (84.2% to 94.4%) for Veritor and 86.8% (78.1% to 93.0%) for Biosensor, and 88.1% (80.5% to 93.5%) for Veritor and 85.1% (74.3% to 92.6%) for Biosensor, among those who remained asymptomatic throughout. Specificities were >99%, and positive and negative predictive values were >90% and >95%, for both rapid antigen tests in all analyses. CONCLUSIONS: The sensitivities of both rapid antigen tests in asymptomatic and presymptomatic close contacts tested on day 5 onwards after close contact with an index case were more than 60%, increasing to more than 85% after a viral load cut-off was applied as a proxy for infectiousness.

3.
Emerg Infect Dis ; 27(5): 1323-1329, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33724916

RESUMEN

Rapid detection of infection is essential for stopping the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The Roche SD Biosensor rapid antigen test for SARS-CoV-2 was evaluated in a nonhospitalized symptomatic population. We rapid-tested a sample onsite and compared results with those from reverse transcription PCR and virus culture. We analyzed date of onset and symptoms using data from a clinical questionnaire. Overall test sensitivity was 84.9% (95% CI 79.1-89.4) and specificity was 99.5% (95% CI 98.7-99.8). Sensitivity increased to 95.8% (95% CI 90.5-98.2) for persons who sought care within 7 days of symptom onset. Test band intensity and time to result correlated strongly with viral load; thus, strong positive results could be read before the recommended time. Approximately 98% of all viable specimens with cycle threshold <30 were detected. Rapid antigen tests can detect symptomatic SARS-CoV-2 infections in the early phase of disease, thereby identifying the most infectious persons.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Servicios de Salud , Humanos , Países Bajos/epidemiología , SARS-CoV-2 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...