Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Perit Dial Int ; 43(6): 467-474, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37723995

RESUMEN

BACKGROUND: The first year of dialysis is critical given the significant risk for complications following dialysis initiation. We analysed complications during the first year among incident peritoneal dialysis (PD) patients. METHODS: This retrospective cohort study comprised adult kidney failure patients starting PD in Baxter Renal Care Services in Colombia, receiving their first PD catheter between 1 January 2017 and 31 December 2020 and were followed up for up to 1 year. We analysed incidence, causes and factors associated with complications using logistic regression and transfer to haemodialysis (HD) using the Fine-Gray regression model. RESULTS: Among 4743 patients receiving their first PD catheter: 4628 (97.6%) of catheter implantations were successful; 377 (7.9%) patients experienced early complications. The incidence rate of complications during the year was 0.51 events per patient-year (95% CI: 0.48-0.54). Age, obesity and urgent start were associated with higher probability of complications after catheter implantation. The cumulative incidence of transfer to HD within 1 year of PD initiation was 10.1% [95% CI: 9.2-11.1%]. The hazard function for transfer to HD showed an accelerating pattern during the first month followed by progressive decrease during the first year. CONCLUSIONS: In this large population of incident PD patients, there is a high primary catheter placement success rate. Urgent start, age ≥65 years, obesity, centre size ≥150 PD patients and diabetes were risk factors associated with early complications. The follow-up of the cohort from day 1 of PD treatment showed that the risk for transfer to HD was higher during the first month.


Asunto(s)
Fallo Renal Crónico , Diálisis Peritoneal , Adulto , Humanos , Anciano , Diálisis Renal/efectos adversos , Diálisis Peritoneal/efectos adversos , Estudios Retrospectivos , Fallo Renal Crónico/complicaciones , Colombia/epidemiología , Obesidad/complicaciones
2.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1535965

RESUMEN

Introduction: Vascular access (VA) remains a major source of morbidity for hemodialysis patients (HD). Few data sources adequately capture longitudinal patency of the VA. This study aimed to evaluate VA failure and its related factors in HD patients. Methods: A retrospective cohort study of 985 incident hemodialysis patients treated in clinics of BRCS in Colombia, from January 1rst ,2016, until December 3 of the same year, was done. The cohort's enrollment was on day 1 of HD, and with follow-up for up to 15 months. Association among a group of independent variables and time to failure of the VA was performed, and adjusted by baseline variables using a Cox regression model. Results: A total of 985 patients were included in the study, requiring 1774 procedures of vascular access during follow-up. The mean age was 61 ± 15.6 years. At day 1, 15 % were dialyzing with an arteriovenous fistula (AVF) or AVG; and at day 90, this proportion had increased to 70 %. The rate of vascular access procedure was 1.95 per patients-year, 95 % CI 1.86-2.04. The rate of vascular access failure was 0.66 per patients-year, 95 % CI 0.61-0.72. Risk factors for failure in AVF/AVG were age > 65 (p= 0.008), diabetes (p=0.019), female sex (p=0.002) rural housing (p<0.0001) and higher hemoglobin (p=0.021). Conclusions: Vascular access failure and the requirement for procedures associated with it are frequent in the dialysis population. Several risk factors, some of them modifiable, are related to vascular access failure.


Introducción: El acceso vascular (AV) sigue siendo una fuente importante de morbilidad para los pacientes en hemodiálisis (HD). Pocas fuentes de datos capturan adecuadamente la permeabilidad longitudinal del AV. Este estudio tiene como objetivo evaluar la falla del AV y los factores relacionados en pacientes en HD. Métodos: Se realizó un estudio de cohorte retrospectivo de 985 pacientes incidentes a hemodiálisis tratados en clínicas de BRCS en Colombia, entre el 1ro de enero de 2016, al 31 de diciembre de 2016. La incepción de la cohorte fue el día 1 de HD y con un seguimiento de hasta 15 meses. Se realizó la asociación entre un grupo de variables independientes y el tiempo hasta la falla del AV, asimismo se ajustó por variables basales mediante un modelo de regresión de Cox. Resultados: Se incluyeron en el estudio un total de 985 pacientes que requirieron 1774 procedimientos de AV durante el seguimiento. La edad media fue de 61 ± 15,6 años. En el día 1, el 15 % se dializaba con una fístula arteriovenosa (FAV) o injerto arteriovenoso (IAV); y al día 90, esta proporción había aumentado al 70 %. La tasa de procedimiento de acceso vascular fue de 1,95 por paciente-año, IC 95 % 1,86-2,04. La tasa de falla del AV fue de 0,66 por paciente-año, IC del 95 %: 0,61-0,72. Los factores de riesgo para falla del AV en FAV/IAV fueron edad > 65 años (p= 0,008), diabetes (p= 0,019), sexo femenino (p= 0,002), vivienda rural (p<0,0001) y hemoglobina elevada (p=0,021). Conclusión: La falla del acceso vascular y el requerimiento de procedimientos asociados a ella, son frecuentes en la población en diálisis. Varios factores de riesgo, algunos de ellos modificables, están relacionados con la falla del acceso vascular.

3.
Int J Nephrol ; 2022: 8646775, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36045901

RESUMEN

Background: Remote patient monitoring (RPM) of patients undergoing automated peritoneal dialysis (APD-RPM) may potentially enhance time on therapy due to possible improvements in technique and patient survival. Objective: To evaluate the effect of APD-RPM as compared to APD without RPM on time on therapy. Methods: Adult incident APD patients undergo APD for 90 days or more in the Baxter Renal Care Services (BRCS) Colombia network between January 1, 2017, and June 30, 2019, with the study follow-up ending June 30, 2021. The exposure variable was APD-RPM vs. APD-without RPM. The outcomes of time on therapy and mortality rate over two years of follow-up were estimated in the full sample and in a matched population according to the exposure variable. A propensity score matching (PSM) 1:1 without replacement utilizing the nearest neighbor within caliper (0.035) was used and created a pseudopopulation in which the baseline covariates were well balanced. Fine & Gray multivariate analysis was performed to assess the effect of demographic, clinical, and laboratory variables on the risk of death, adjusting for the competing risks of technique failure and kidney transplantation. Results: In the matched sample, the time on APD therapy was significantly longer in the RPM group than in the non-RPM group, 18.95 vs. 15.75 months, p < 0.001. The mortality rate did not differ between the two groups: 0.10 events per patient-year in the RPM group and 0.12 in the non-RPM group, p=0.325. Conclusion: Over two years of follow-up, the use of RPM vs. no RPM in APD patients was associated with a significant increase in time on therapy, by 3.2 months. This result indicates that RPM-supported APD therapy may improve the clinical effectiveness and the overall quality of APD.

4.
Kidney Med ; 4(4): 100431, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35492142

RESUMEN

Rationale & Objective: This study investigated the effects on patients' outcomes of using medium cutoff (MCO) versus high-flux (HF) dialysis membranes. Study Design: A retrospective, observational, multicenter, cohort study. Setting & Participants: Patients aged greater than 18 years receiving hemodialysis at the Baxter Renal Care Services dialysis network in Colombia. The inception of the cohort occurred from September 1, 2017, to November 30, 2017, with follow-up to November 30, 2019. Exposure: The patients were divided into 2 cohorts according to the dialyzer used at the inception: (1) MCO membrane or (2) HF membrane. Outcomes: Primary outcomes were the hospitalization rate from any cause and hospitalization days per patient-year. Secondary outcomes were acute cardiovascular events and mortality rates from any cause and secondary to cardiovascular causes. Laboratory parameters were assessed throughout the 2-year follow-up period. Analytical Approach: Descriptive statistics were used to report population characteristics. Inverse probability of treatment weighting was applied to each group before analysis. All categorical variables were compared using Pearson's χ2 test, and continuous variables were analyzed with the t test. Baseline differences between groups with a value of >10% were considered clinically meaningful. Laboratory variables were measured at 5 consecutive time points. A between-patient effect was analyzed using a split-plot factorial analysis of variance. Results: The analysis included 1,098 patients, of whom 564 (51.3%) were dialyzed with MCO membranes and 534 (48.7%) with HF membranes. Patients receiving hemodialysis with MCO membranes had a lower all-cause hospitalization incidence rate (IR) per patient-year (IR = 0.93; 95% CI, 0.82-1.03) than those receiving hemodialysis with HF membranes (IR = 1.13; 95% CI, 0.96-1.30), corresponding to a significant incident rate ratio (MCO/HF) of 0.82 (95% CI, 0.68-0.99; P = 0.04). The frequency of nonfatal cardiovascular events showed statistical significance, with a lower incidence in the MCO group (incident rate ratio = 0.66; 95% CI, 0.46-0.96; P = 0.03). No statistically significant differences in all-cause time until death were observed (P = 0.48). Albumin levels were similar between the 2 dialyzer cohorts. Limitations: Despite the robust statistical analysis, there remains the possibility that unmeasured variables may still generate residual imbalance and, therefore, skew the results. Conclusions: The incidences of hospitalization and cardiovascular events in patients receiving hemodialysis were lower when dialyzed with MCO membranes than HF membranes. A randomized controlled trial would be desirable to confirm these results. Trial Registration: Clinical Trials.gov, ISRCTN12403265.

5.
Perit Dial Int ; 42(3): 288-296, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-33380265

RESUMEN

BACKGROUND: Remote patient monitoring (RPM) programs in automated peritoneal dialysis (APD) allow clinical teams to be aware of many aspects and events of the therapy that occur in the home. The present study evaluated the association between RPM use and APD technique failure. METHODS: A retrospective, multicentre, observational cohort study of 558 prevalent adult APD patients included between 1 October 2016 and 30 June 2017 with follow-up until 30 June 2018 at Renal Therapy Services network in Colombia. Patients were divided into two cohorts based on the RPM use: APD-RPM (n = 148) and APD-without RPM (n = 410). Sociodemographic and clinical characteristics of all patients were summarized descriptively. A propensity score was used to create a pseudo-population in which the baseline covariates were well balanced. The association of RPM with technique failure was estimated adjusting for the competing events death and kidney transplant. RESULTS: Five hundred fifty-eight patients were analyzed. 26.5% had APD-RPM. In the matched sample comprising 148 APD-RPM and 148 APD-without RPM patients, we observed a lower technique failure rate of 0.08 [0.05-0.15] episodes per patient-year in APD-RPM versus 0.18 [0.12-0.26] in APD-without RPM cohort; incidence rate ratio = 0.45 95% confidence interval: [0.22-0.91], p-value = 0.03. CONCLUSIONS: The use of an RPM program in APD patients may be associated with a lower technique failure rate. More extensive and interventional studies are needed to confirm its potential benefits and to measure other patient-centered outcomes.


Asunto(s)
Fallo Renal Crónico , Diálisis Peritoneal , Adulto , Estudios de Cohortes , Femenino , Humanos , Incidencia , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Masculino , Monitoreo Fisiológico/métodos , Diálisis Peritoneal/métodos , Estudios Retrospectivos
6.
Blood Purif ; 51(9): 780-790, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34903682

RESUMEN

INTRODUCTION: Comparisons of survival between dialysis modalities is of great importance to patients with kidney failure, their families, and healthcare systems. OBJECTIVE: This study's objective was to compare mortality of patients on chronic hemodialysis (HD) or peritoneal dialysis (PD) and identify variables associated with mortality. METHODS: This retrospective cohort study included adult incident patients with kidney failure treated with HD or PD by the Baxter Renal Care Services network in Colombia. The study was conducted between January 1, 2008, and December 31, 2013 (recruitment period), with follow-up until December 31, 2018. The outcome was the cumulative mortality rate at 1, 2, 3, 4, and 5 years. Propensity score matching (PSM) and the Gompertz parametric survival model were used to compare mortality in HD versus PD. RESULTS: The analysis included 12,499 patients, of whom 57.4% were on PD at inception. The overall mortality rate was 14.0 events per 100 patient-years (95% confidence interval [CI], 13.61-14.42). Using an intention-to-treat approach, crude mortality rates were significantly lower in patients receiving HD (HD: 12.3 deaths per 100 patient-years [95% CI, 11.7-12.8] vs. PD: 15.5 [14.9-16.1], p < 0.01). Using a Gompertz parametric survival model, dialysis modality was not significantly associated with mortality (hazard ratio HD vs. PD 1.0, 95% CI, 0.9-1.1). After PSM, the mortality cumulative incidence functions between HD and PD were not statistically significantly different (p = 0.88). CONCLUSIONS: The present study in a large cohort of incident dialysis patients with at least 5 years follow-up and using PSM methods showed no differences in cumulative mortality between HD and PD patients. This evidence from a middle-income country may facilitate the process of dialysis modality selection globally.


Asunto(s)
Fallo Renal Crónico , Diálisis Peritoneal , Adulto , Humanos , Fallo Renal Crónico/complicaciones , Diálisis Peritoneal/métodos , Modelos de Riesgos Proporcionales , Diálisis Renal/métodos , Estudios Retrospectivos
7.
Perit Dial Int ; 42(4): 370-376, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34886728

RESUMEN

BACKGROUND: Treatment of kidney failure with peritoneal dialysis (PD) at home implies that the patient and/or their caregiver develop a series of skills and basic knowledge about this therapy. There is not a specific inventory of the patient's abilities to safely perform the PD procedure at home. The objective of this study was to describe the development of an instrument that allows measuring the self-management capacity of patients receiving PD, locating the performance areas that justify the need for intervention by a caregiver. METHODS: This is a qualitative study developed in three phases: The first phase was the identification of performance areas through bibliographic search and validation of the results with focus groups of experts in PD. The second phase was the design of a system to measure self-management capacities. The third phase was a pilot test of the preliminary version of the instrument applied in 20 incident PD patients. RESULTS: Three domains were identified to evaluate the fundamental components of self-management capacity: cognitive and sensory, each one evaluated with four items and motor domain evaluated with eight items. After applying the instrument, we found that 15 patients (75%) did not require support from the caregiver in any of the items. PD patients and nurses found the tool valuable, easy to understand and applicable in the early evaluation of a PD patient. CONCLUSIONS: We developed an easy-to-administer instrument to measure the self-management capacity of patients receiving PD. This inventory could locate areas that require specific support from a caregiver. Planning an individualised and focused education and training process could result in better health outcomes.


Asunto(s)
Diálisis Peritoneal , Automanejo , Anciano , Cuidadores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diálisis Peritoneal/métodos , Investigación Cualitativa
8.
Kidney Med ; 3(3): 335-342.e1, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34136779

RESUMEN

RATIONALE & OBJECTIVE: Technique failure in peritoneal dialysis (PD) remains one of the most critical challenges of this therapy and is associated with a significant increase in costs and morbidity. Our objective was to estimate the frequency of PD technique failure and identify factors associated with technique failure. STUDY DESIGN: A retrospective multicenter observational cohort study. SETTING & PARTICIPANTS: All adult patients initiating PD between January 1, 2010, and December 31, 2015, with follow-up until December 31, 2018, at the Renal Therapy Services network in Colombia. EXPOSURE & PREDICTORS: PD modality (continuous ambulatory PD and automated PD) and demographic and clinical characteristics. OUTCOMES: Technique failure, defined as a switch to hemodialysis lasting at least 30 days. ANALYTICAL APPROACH: Sociodemographic and clinical characteristics of all patients were summarized descriptively according to modality. We estimated the cumulative incidence of technique failure, and a flexible parametric survival model with competing risks was used to evaluate factors associated with this outcome. RESULTS: Among 6,452 patients meeting inclusion criteria, 67% were treated with continuous ambulatory PD. The cumulative incidence of technique failure within 1 year of PD initiation adjusting for competing risks was 6.9% (95% CI, 6.3%-7.6%); within 2 years, technique failure was 13.5% (95% CI, 12.6%-14.4%); and within 3 years, 19.6% (95% CI, 18.5%-20.7%). Female sex, larger center size, and higher Kt/V were associated with lower risk for modality change, whereas diabetes, history of major abdominal surgery, catheter implant technique (laparotomy and percutaneous techniques), obesity, and peritonitis were associated with a higher likelihood of technique failure. LIMITATIONS: Variables of distance to the center, use of icodextrin, and measures of outcomes reported by patients were not included. CONCLUSIONS: Technique failure is relatively uncommon in Colombia; catheter-related problems are the most frequent cause of technique failure. Best practices in catheter insertion could minimize the risk for this outcome.

9.
Int J Nephrol ; 2021: 8866446, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33868729

RESUMEN

BACKGROUND: Variability in chronic kidney disease (CKD) progression is a well-known phenomenon that underlines the importance of characterizing the said outcome in specific populations. Our objectives were to evaluate changes in the estimated glomerular filtration rate (eGFR) over time and determine the frequency of dialysis admission and factors associated with this outcome, to estimate the rate of program's loss-to-follow-up and the probability of transition between CKD stages over time. METHODS: The study type was an observational analytic retrospective cohort in patients treated in a CKD prevention program in Bogota, Colombia, between January 1, 2009, and December 31, 2013, with follow-up until December 31, 2018. Adult participants of 18 years of age or older with diagnosed CKD stages G3 or G4 were enrolled into a prevention program. For each patient, the rate of progression of CKD in ml/min/1.73 m2/year was estimated using the ordinary least-squares method. Dialysis initiation and program's loss-to-follow-up rates were calculated. Heat maps were used to present probabilities of transitioning between various CKD stages over time. Survival model with competing risks was used to evaluate factors associated with dialysis initiation. RESULTS: A total of 2752 patients met inclusion criteria and contributed with 14133 patient-years of follow-up and 200 dialysis initiation events, which represents a rate of 1.4 events per 100 patient-years (95% CI 1.2 to 1.6). The median change of the eGFR for the entire cohort was -0.47 ml/min/1.73 m2 per year, and in the diabetic population, it was -1.55 ml/min/1.73 m2 per year. The program's loss-to-follow-up rate was 2.6 events per 100 patient-years (95% CI 2.3 to 2.9). Probabilities of CKD stage transitions are presented in heat maps. Female sex, older age, baseline eGFR, and serum albumin were associated with lower risk of dialysis initiation while CKD etiology diabetes, cardiovascular disease history, systolic blood pressure, blood urea nitrogen, and LDL cholesterol were associated with a higher likelihood of dialysis initiation. CONCLUSIONS: A CKD secondary prevention program's key indicator is reported here, such as dialysis initiation, progression rate, and program drop-out; CKD progression appears to be correlated with diabetic status and timing of referral into the preventive program.

10.
Nephron ; 145(2): 179-187, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33596561

RESUMEN

INTRODUCTION: Expanded hemodialysis (HDx) effectively removes large middle molecular uremic toxins (>25 kDa) while still retaining albumin, potentially reducing their adverse effects. We compare the clinical laboratory parameters, hospitalization rates, and medication use in a cohort of patients switched from high-flux HD to HDx. METHODS: This is a multicenter, observational cohort study of 81 adult patients, across 3 clinics, with end-stage kidney disease (ESKD) on chronic hemodialysis (HD). Patients received high-flux HD for at least 1 year and then switched to HDx and were followed up for 1 year. Patients were excluded if they discontinued therapy, changed provider, underwent kidney transplant, recovered kidney function, or changed to peritoneal dialysis, another dialyzer, or renal clinic. RESULTS: Twelve months after switching to HDx, the rate of hospitalization events per patient-year decreased from 0.77 (95% CI: 0.60-0.98, 61 events) to 0.71 (95% CI: 0.55-0.92, 57 events) (p = 0.6987). The hospital day rate per patient-year was significantly reduced from 5.94 days in the year prior to switching compared with 4.41 days after switching (p = 0.0001). The mean dose of erythropoiesis-stimulating agent (SC epoetin-α) and intravenous iron also significantly decreased (p = 0.0361 and p = 0.0003, respectively). CONCLUSION: Switching to HDx was associated with reductions in hospital day rate and medication use, suggesting HDx has the potential to reduce the burden of ESKD on patients and healthcare systems.


Asunto(s)
Hospitalización , Fallo Renal Crónico/terapia , Diálisis Renal , Anciano , Estudios de Cohortes , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Fallo Renal Crónico/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Diálisis Renal/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA