Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Anesth Analg ; 2023 Oct 12.
Article En | MEDLINE | ID: mdl-37824436

BACKGROUND: The dural puncture epidural (DPE) technique has a faster onset, better sacral spread, and improved bilateral coverage when compared to the conventional epidural (EPL) technique. Whether these qualities translate into a lower bupivacaine dose to provide initial analgesia is unknown. We sought to determine the effective dose of bupivacaine to achieve initial (first 30 minutes) labor analgesia in 90% of patients (ED90) with the DPE and EPL techniques, using a biased-coin, sequential allocation method. METHODS: A total of 100 women of mixed parity with term, singleton gestation at ≤5 cm dilation with no major comorbidities were randomized to receive a DPE or an EPL technique. An experienced anesthesiologist performed these techniques and administered an allocated dose of plain bupivacaine diluted with isotonic sterile 0.9% saline to a total volume of 20 mL via the EPL catheter. Bupivacaine doses for each subject were determined by the response of the previous subject, using a biased-coin sequential allocation method, with success defined by a numeric rating scale (NRS) < 3 at 30 minutes. Outcome assessments were performed by an investigator blinded to the technique and bupivacaine dose. Sensory and motor blockade and maternal or fetal side effects were recorded every 5 minutes for the first 30 minutes. The ED90 of bupivacaine with each technique was estimated using centered isotonic regression. RESULTS: A total of 95 women were included in the final analysis. The ED90 of bupivacaine was estimated at 29.30 mg (90% confidence interval [CI], 28.55-31.56) with a DPE technique and 45.25 mg (90% CI, 42.80-52.03) with an EPL technique. CONCLUSIONS: Using a biased-coin, sequential allocation method, the DPE technique requires less bupivacaine to achieve effective initial analgesia (ED90) when compared to the EPL technique.

...