Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 5 de 5
2.
Biol Sex Differ ; 14(1): 76, 2023 11 01.
Article En | MEDLINE | ID: mdl-37915069

BACKGROUND: Females have been historically excluded from biomedical research due in part to the documented presumption that results with male subjects will generalize effectively to females. This has been justified in part by the assumption that ovarian rhythms will increase the overall variance of pooled random samples. But not all variance in samples is random. Human biometrics are continuously changing in response to stimuli and biological rhythms; single measurements taken sporadically do not easily support exploration of variance across time scales. Recently we reported that in mice, core body temperature measured longitudinally shows higher variance in males than cycling females, both within and across individuals at multiple time scales. METHODS: Here, we explore longitudinal human distal body temperature, measured by a wearable sensor device (Oura Ring), for 6 months in females and males ranging in age from 20 to 79 years. In this study, we did not limit the comparisons to female versus male, but instead we developed a method for categorizing individuals as cyclic or acyclic depending on the presence of a roughly monthly pattern to their nightly temperature. We then compared structure and variance across time scales using multiple standard instruments. RESULTS: Sex differences exist as expected, but across multiple statistical comparisons and timescales, there was no one group that consistently exceeded the others in variance. When variability was assessed across time, females, whether or not their temperature contained monthly cycles, did not significantly differ from males both on daily and monthly time scales. CONCLUSIONS: These findings contradict the viewpoint that human females are too variable across menstrual cycles to include in biomedical research. Longitudinal temperature of females does not accumulate greater measurement error over time than do males and the majority of unexplained variance is within sex category, not between them.


Women are still excluded from research disproportionately, due in part to documented concerns that menstrual cycles make them more variable and so harder to study. In the past, we have challenged this claim, finding it does not hold for animal physiology, animal behavior, or human behavior. Here we are able to show that it does not hold in human physiology either. We analyzed 6 months of continuously collected temperature data measured by a commercial wearable device, in order to determine if it is true that females are more variable or less predictable than males. We found that temperatures mostly vary as a function of time of day and whether the individual was awake or asleep. Additionally, for some females, nightly maximum temperature contained a cyclical pattern with a period of around 28 days, consistent with menstrual cycles. The variability was different between cycling females, not cycling females, and males, but only cycling female temperature contained a monthly structure, making their changes more predictable than those of non-cycling females and males. We found the majority of unexplained variance to be within each sex/cycling category, not between them. All groups had indistinguishable measurement errors across time. This analysis of temperature suggests data-driven characteristics might be more helpful distinguishing individuals than historical categories such as binary sex. The work also supports the inclusion of females as subjects within biological research, as this inclusion does not weaken statistical comparisons, but does allow more equitable coverage of research results in the world.


Menstrual Cycle , Wearable Electronic Devices , Humans , Male , Female , Mice , Animals , Young Adult , Adult , Middle Aged , Aged , Temperature , Periodicity , Sex Characteristics
3.
NPJ Digit Med ; 5(1): 146, 2022 Sep 19.
Article En | MEDLINE | ID: mdl-36123367

Hypoxemia, a medical condition that occurs when the blood is not carrying enough oxygen to adequately supply the tissues, is a leading indicator for dangerous complications of respiratory diseases like asthma, COPD, and COVID-19. While purpose-built pulse oximeters can provide accurate blood-oxygen saturation (SpO2) readings that allow for diagnosis of hypoxemia, enabling this capability in unmodified smartphone cameras via a software update could give more people access to important information about their health. Towards this goal, we performed the first clinical development validation on a smartphone camera-based SpO2 sensing system using a varied fraction of inspired oxygen (FiO2) protocol, creating a clinically relevant validation dataset for solely smartphone-based contact PPG methods on a wider range of SpO2 values (70-100%) than prior studies (85-100%). We built a deep learning model using this data to demonstrate an overall MAE = 5.00% SpO2 while identifying positive cases of low SpO2 < 90% with 81% sensitivity and 79% specificity. We also provide the data in open-source format, so that others may build on this work.

5.
Sci Rep ; 12(1): 3463, 2022 03 02.
Article En | MEDLINE | ID: mdl-35236896

Early detection of diseases such as COVID-19 could be a critical tool in reducing disease transmission by helping individuals recognize when they should self-isolate, seek testing, and obtain early medical intervention. Consumer wearable devices that continuously measure physiological metrics hold promise as tools for early illness detection. We gathered daily questionnaire data and physiological data using a consumer wearable (Oura Ring) from 63,153 participants, of whom 704 self-reported possible COVID-19 disease. We selected 73 of these 704 participants with reliable confirmation of COVID-19 by PCR testing and high-quality physiological data for algorithm training to identify onset of COVID-19 using machine learning classification. The algorithm identified COVID-19 an average of 2.75 days before participants sought diagnostic testing with a sensitivity of 82% and specificity of 63%. The receiving operating characteristic (ROC) area under the curve (AUC) was 0.819 (95% CI [0.809, 0.830]). Including continuous temperature yielded an AUC 4.9% higher than without this feature. For further validation, we obtained SARS CoV-2 antibody in a subset of participants and identified 10 additional participants who self-reported COVID-19 disease with antibody confirmation. The algorithm had an overall ROC AUC of 0.819 (95% CI [0.809, 0.830]), with a sensitivity of 90% and specificity of 80% in these additional participants. Finally, we observed substantial variation in accuracy based on age and biological sex. Findings highlight the importance of including temperature assessment, using continuous physiological features for alignment, and including diverse populations in algorithm development to optimize accuracy in COVID-19 detection from wearables.


Body Temperature , COVID-19/diagnosis , Wearable Electronic Devices , Adolescent , Adult , Aged , Aged, 80 and over , Algorithms , COVID-19/virology , Female , Humans , Male , Middle Aged , SARS-CoV-2/isolation & purification , Young Adult
...