Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Europace ; 23(11): 1767-1776, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34240134

RESUMEN

AIMS: Pulsed field ablation (PFA), a non-thermal ablative modality, may show different effects on the myocardial tissue compared to thermal ablation. Thus, this study aimed to compare the left atrial (LA) structural and mechanical characteristics after PFA vs. thermal ablation. METHODS AND RESULTS: Cardiac magnetic resonance was performed pre-ablation, acutely (<3 h), and 3 months post-ablation in 41 patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein (PV) isolation with PFA (n = 18) or thermal ablation (n = 23, 16 radiofrequency ablations, 7 cryoablations). Late gadolinium enhancement (LGE), T2-weighted, and cine images were analysed. In the acute stage, LGE volume was 60% larger after PFA vs. thermal ablation (P < 0.001), and oedema on T2 imaging was 20% smaller (P = 0.002). Tissue changes were more homogeneous after PFA than after thermal ablation, with no sign of microvascular damage or intramural haemorrhage. In the chronic stage, the majority of acute LGE had disappeared after PFA, whereas most LGE persisted after thermal ablation. The maximum strain on PV antra, the LA expansion index, and LA active emptying fraction declined acutely after both PFA and thermal ablation but recovered at the chronic stage only with PFA. CONCLUSION: Pulsed field ablation induces large acute LGE without microvascular damage or intramural haemorrhage. Most LGE lesions disappear in the chronic stage, suggesting a specific reparative process involving less chronic fibrosis. This process may contribute to a preserved tissue compliance and LA reservoir and booster pump functions.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Medios de Contraste , Fibrosis , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Atrios Cardíacos/cirugía , Humanos , Imagen por Resonancia Magnética
2.
Europace ; 23(9): 1391-1399, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33961027

RESUMEN

AIMS: Extra-atrial injury can cause complications after catheter ablation for atrial fibrillation (AF). Pulsed field ablation (PFA) has generated preclinical data suggesting that it selectively targets the myocardium. We sought to characterize extra-atrial injuries after pulmonary vein isolation (PVI) between PFA and thermal ablation methods. METHODS AND RESULTS: Cardiac magnetic resonance (CMR) imaging was performed before, acutely (<3 h) and 3 months post-ablation in 41 paroxysmal AF patients undergoing PVI with PFA (N = 18, Farapulse) or thermal methods (N = 23, 16 radiofrequency, 7 cryoballoon). Oesophageal and aortic injuries were assessed by using late gadolinium-enhanced (LGE) imaging. Phrenic nerve injuries were assessed from diaphragmatic motion on intra-procedural fluoroscopy. Baseline CMR showed no abnormality on the oesophagus or aorta. During ablation procedures, no patient showed phrenic palsy. Acutely, thermal methods induced high rates of oesophageal lesions (43%), all observed in patients showing direct contact between the oesophagus and the ablation sites. In contrast, oesophageal lesions were observed in no patient ablated with PFA (0%, P < 0.001 vs. thermal methods), despite similar rates of direct contact between the oesophagus and the ablation sites (P = 0.41). Acute lesions were detected on CMR on the descending aorta in 10/23 (43%) after thermal ablation, and in 6/18 (33%) after PFA (P = 0.52). CMR at 3 months showed a complete resolution of oesophageal and aortic LGE in all patients. No patient showed clinical complications. CONCLUSION: PFA does not induce any signs of oesophageal injury on CMR after PVI. Due to its tissue selectivity, PFA may improve safety for catheter ablation of AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Esófago/diagnóstico por imagen , Esófago/cirugía , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
3.
Circ Res ; 127(1): 170-183, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32716722

RESUMEN

Atrial fibrillation is the most common sustained cardiac arrhythmia and is associated with considerable morbidity and mortality. Electrically isolating the pulmonary veins from the left atrium by catheter ablation is superior to antiarrhythmic drug therapy for maintaining sinus rhythm, but its success varies depending on multiple factors, including arrhythmic burden. Although procedural outcomes have improved over the years, further gains are limited by a seemingly zero-sum relationship between effectiveness and safety, which is largely a product of the available technologies. Current energies used to create contiguous, transmural, and durable atrial lesions can result in serious complications if they reach the esophagus or phrenic nerve, for instance-structures that can be adjacent to the atrial myocardium, often within millimeters of the energy source. Consequently, high rates of pulmonary vein-left atrium reconnections are consistently seen in clinical studies and in clinical practice as operators appropriately forgo ablation effectiveness to protect patients from harm. However, as ablative technologies evolve to circumvent this stalemate, safer, and more effective pulmonary vein isolation seems increasingly realistic. Furthermore, the innovative nature of these technologies raises the prospect of markedly improved procedural efficiency, which could increase patient comfort, reduce operator occupational injuries, and enhance the use of health resources-all of which are increasingly important considerations particularly as the demand for catheter ablation for atrial fibrillation continues to rise. We herein review 3 promising candidate ablation technologies with the potential to revolutionize the management of patients with atrial fibrillation: electroporation (pulsed-field ablation), expandable lattice-tip radiofrequency ablation/electroporation, and ultra-low temperature cryoablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Animales , Humanos
4.
Circ Arrhythm Electrophysiol ; 13(3): e008303, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31977250

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) can be myocardium selective, potentially sparing the esophagus during left atrial ablation. In an in vivo porcine esophageal injury model, we compared the effects of newer biphasic PFA with radiofrequency ablation (RFA). METHODS: In 10 animals, under general anesthesia, the lower esophagus was deflected toward the inferior vena cava using an esophageal deviation balloon, and ablation was performed from within the inferior vena cava at areas of esophageal contact. Four discrete esophageal sites were targeted in each animal: 6 animals received 8 PFA applications/site (2 kV, multispline catheter), and 4 animals received 6 clusters of irrigated RFA applications (30 W×30 seconds, 3.5 mm catheter). All animals were survived to 25 days, sacrificed, and the esophagus submitted for pathological examination, including 10 discrete histological sections/esophagus. RESULTS: The animals weight increased by 13.7±6.2% and 6.8±6.3% (P=0.343) in the PFA and RFA cohorts, respectively. No PFA animals (0 of 6, 0%) developed abnormal in-life observations, but 1 of 4 RFA animals (25%) developed fever and dyspnea. On necropsy, no PFA animals (0 of 6, 0%) demonstrated esophageal lesions. In contrast, esophageal injury occurred in all RFA animals (4 of 4, 100%; P=0.005): a mean of 1.5 mucosal lesions/animal (length, -21.8±8.9 mm; width, -4.9±1.4 mm) were observed, including one esophago-pulmonary fistula and deep esophageal ulcers in the other animals. Histological examination demonstrated tissue necrosis surrounded by acute and chronic inflammation and fibrosis. The necrotic RFA lesions involved multiple esophageal tissue layers with evidence of arteriolar medial thickening and fibrosis of periesophageal nerves. Abscess formation and full-thickness esophageal wall disruptions were seen in areas of perforation/fistula. CONCLUSIONS: In this novel porcine model of esophageal injury, biphasic PFA induced no chronic histopathologic esophageal changes, while RFA demonstrated a spectrum of esophageal lesions including fistula and deep esophageal ulcers and abscesses.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Esófago/lesiones , Atrios Cardíacos/cirugía , Complicaciones Posoperatorias/prevención & control , Animales , Ablación por Catéter/efectos adversos , Modelos Animales de Enfermedad , Complicaciones Posoperatorias/etiología , Porcinos
5.
Europace ; 22(3): 434-439, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31876913

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel, non-thermal modality that selectively ablates myocardium with ultra-short electrical impulses while sparing collateral tissues. In a proof-of-concept study, the safety and feasibility of ventricular PFA were assessed using a prototype steerable, endocardial catheter. METHODS AND RESULTS: Under general anaesthesia, the left and right ventricles of four healthy swine were ablated using the 12-Fr deflectable PFA catheter and a deflectable sheath guided by electroanatomic mapping. Using the study catheter, electrograms were recorded for each site and pre-ablation and post-ablation pacing thresholds (at 2.0 ms pulse width) were recorded in two of four animals. After euthanasia at 35.5 days, the hearts were submitted for histology. The PFA applications (n = 39) resulted in significant electrogram reduction without ventricular arrhythmias. In ablation sites where it was measured, the pacing thresholds increased by >16.8 mA in the right ventricle (3 sites) and >16.1 mA in the left ventricle (7 sites), with non-capture at maximum amplitude (20 mA) observable in 8 of 10 sites. Gross measurements, available for 28 of 30 ablation sites, revealed average lesion dimensions to be 6.5 ± 1.7 mm deep by 22.6 ± 4.1 mm wide, with a maximum depth and width of 9.4 mm and 28.6 mm, respectively. In the PFA lesions, fibrous tissue homogeneously replaced myocytes with a narrow zone of surrounding myocytolysis and no overlying thrombus. When present, nerve fascicles and vasculature were preserved within surrounding fibrosis. CONCLUSION: We demonstrate that endocardial PFA can be focally delivered using this prototype catheter to create homogeneous, myocardium-specific lesions.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Animales , Arritmias Cardíacas , Endocardio , Ventrículos Cardíacos/cirugía , Miocardio , Porcinos , Taquicardia Ventricular/cirugía
6.
Circ Arrhythm Electrophysiol ; 12(12): e007781, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31826647

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is a uniquely tissue-selective, nonthermal cardiac ablation modality. Delivery parameters such as the electrical waveform composition and device design are critical to PFA's efficacy and safety, particularly tissue specificity. In a series of preclinical studies, we sought to examine the electrophysiological and histological effects of PFA and compare the safety and feasibility of durable pulmonary vein and superior vena cava (SVC) isolation between radiofrequency ablation and PFA waveforms. METHODS: A femoral venous approach was used to gain right and left atrial access under general anesthesia in healthy swine. Baseline potentials in right superior pulmonary and inferior common vein and in SVC were assessed. Bipolar PFA was performed with monophasic (PFAMono) and biphasic (PFABi) waveforms in 7 and 7 swine sequentially and irrigated radiofrequency ablation in 3 swine. Vein potentials were then assessed acutely, and at ≈10 weeks; histology was obtained. RESULTS: All targeted veins (n=46) were successfully isolated on the first attempt in all cohorts. The PFABi waveform induced significantly less skeletal muscle engagement. Pulmonary vein isolation durability was assessed in 28 veins: including the SVC, durability was significantly higher in the PFABi group (18/18 PFABi, 10/18 PFAMono, 3/6 radiofrequency, P=0.002). Transmurality rates were similar across groups with evidence of nerve damage only with radiofrequency. Pulmonary vein narrowing was noted only in the radiofrequency cohort. The phrenic nerve was spared in all cohorts but at the expense of incomplete SVC encirclement with radiofrequency. CONCLUSIONS: In this chronic porcine study, PFA-based pulmonary vein and SVC isolation were safe and efficacious with demonstrable sparing of nerves and venous tissue. This preclinical study provided the scientific basis for the first-in-human endocardial PFA studies.


Asunto(s)
Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Tórax/irrigación sanguínea , Vena Cava Superior/cirugía , Potenciales de Acción , Animales , Ablación por Catéter/efectos adversos , Femenino , Venas Pulmonares/patología , Venas Pulmonares/fisiopatología , Sus scrofa , Vena Cava Superior/patología , Vena Cava Superior/fisiopatología
7.
Biol Direct ; 9: 1, 2014 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-24405803

RESUMEN

BACKGROUND: A recent study argued, based on data on functional genome size of major phyla, that there is evidence life may have originated significantly prior to the formation of the Earth. RESULTS: Here a more refined regression analysis is performed in which 1) measurement error is systematically taken into account, and 2) interval estimates (e.g., confidence or prediction intervals) are produced. It is shown that such models for which the interval estimate for the time origin of the genome includes the age of the Earth are consistent with observed data. CONCLUSIONS: The appearance of life after the formation of the Earth is consistent with the data set under examination.


Asunto(s)
Planeta Tierra , Genoma , Modelos Genéticos , Evolución Molecular , Análisis de Regresión
8.
IEEE Trans Biomed Eng ; 49(2): 85-96, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12066887

RESUMEN

We have used agarose gel to develop a robust model of the intraparenchymal brain tissues for the purpose of simulating positive-pressure infusion of therapeutic agents directly into the brain. In parallel with that effort, we have synthesized a mathematical description of the infusion process on the basis of a poroelastic theory for the swelling of the tissues under the influence of the infusate's penetration into the interstitial space. Infusion line pressure measurements and video microscopy determinations of infusate volume of distribution within the gel demonstrate a good match between theory and experiment over a wide range of flow rates (0.5-10.0 microliters/min) and have clinical relevance for the convection-enhanced delivery of drugs into the brain without hindrance by the blood-brain barrier. We have put the brain phantom gel and the infusion measurement system into routine use in determining performance characteristics of novel types of neurosurgical catheters. This approach simplifies the catheter design process and helps to avoid some of the costs of in vivo testing. It also will allow validation of the elementary aspects of treatment planning systems that predict infusion distribution volumes on the basis of theoretical descriptions such as those derived from the poroelastic model.


Asunto(s)
Encéfalo/fisiología , Sistemas de Liberación de Medicamentos/métodos , Infusiones Parenterales/instrumentación , Infusiones Parenterales/métodos , Modelos Neurológicos , Catéteres de Permanencia , Sistemas de Liberación de Medicamentos/instrumentación , Elasticidad , Geles/química , Humanos , Microscopía por Video , Porosidad , Presión , Reología , Sefarosa/química , Factores de Tiempo , Viscosidad
SELECCIÓN DE REFERENCIAS