1.
Int J Tuberc Lung Dis ; 22(8): 945-949, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29991406

RESUMEN

SETTING: National Mycobacterium Reference Laboratory, Borstel, Germany. OBJECTIVE: To evaluate the effectiveness of OMNIgene®â€¢SPUTUM (OM-S) reagent in comparison with a method using N-acetyl-L-cysteine-sodium hydroxide (NALC-NaOH) with regard to mycobacterial recovery and contamination of broth and solid cultures. DESIGN: Sputum samples from patients with tuberculosis and other respiratory diseases underwent decontamination with NALC-NaOH-based (MycoDDR™) or OM-S reagent. The decontamination procedure was assigned by block randomisation. Samples were inoculated on Löwenstein-Jensen, Stonebrink and MGIT™ (Mycobacterial Growth Indicator Tubes). Mycobacterial recovery from samples spiked with Mycobacterium tuberculosis following decontamination was determined. RESULTS: Eighty-five samples were randomised to NALC-NaOH and 84 to OM-S reagent. Mycobacterial recovery was significantly lower for samples processed with OM-S reagent compared with the NALC-NaOH method across all media types. Culture contamination was lower with NALC-NaOH reagent on solid media (9.4-12.9% vs. 28.6-29.8%). Growth was not observed in MGIT among samples spiked with 10 600-16 800 colony-forming units of M. tuberculosis following decontamination with OM-S reagent. CONCLUSION: Low mycobacterial recovery, especially in MGIT, observed in the present study suggests that OM-S reagent might not be compatible with the MGIT system. More extensive field evaluations of the OM-S reagent are warranted to demonstrate a significant benefit over currently used methods.


Asunto(s)
Descontaminación/métodos , Indicadores y Reactivos/química , Mycobacterium tuberculosis/aislamiento & purificación , Manejo de Especímenes/métodos , Esputo/microbiología , Técnicas Bacteriológicas , Alemania , Humanos , Laboratorios de Hospital , Transportes , Tuberculosis/diagnóstico
2.
Phys Med ; 32(12): 1594-1601, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27914781

RESUMEN

PURPOSE: Converting the measurable quantities to patient organ doses in projection radiography is usually based on a standard-sized patient model and a specific radiation quality, which are likely to differ from the real situation. Large inaccuracies can therefore be obtained in organ doses, because organ doses are dependent on the exposure parameters, exposure geometry and patient anatomy. In this study, the effect of radiation quality and patient thickness on the organ dose conversion factors were determined. METHODS: In this study, the posterior-anterior projection radiograph of the thorax was selected in order to determine the effect of radiation quality (tube voltages of 70-130kV and total filtrations of 3mmAl to 4mmAl+0.2 mmCu) and patient thickness (anterior-posterior thicknesses of 19.4-30.8cm) on the breast and lung dose conversion factors. For this purpose, Monte Carlo simulation programs ImpactMC and PCXMC were used with computed tomography examination data of adult male and female patients and mathematical hermaphrodite phantoms, respectively. RESULTS: Compared to the reference beam quality and patient thickness, the relative variation range in organ dose conversion factors was up to 74% for different radiation qualities and 122% for different patient thicknesses. CONCLUSIONS: Conversion factors should only be used with comprehensive understanding of the exposure conditions, considering the exposure parameters, exposure geometry and patient anatomy they are valid for. This study demonstrates that patient thickness-specific and radiation quality-specific conversion factors are needed in projection radiography.


Asunto(s)
Absorción de Radiación , Tamaño Corporal , Mama/efectos de la radiación , Pulmón/efectos de la radiación , Dosis de Radiación , Radiografía Torácica/métodos , Adulto , Mama/diagnóstico por imagen , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Método de Montecarlo , Fantasmas de Imagen , Incertidumbre
3.
Cardiovasc Intervent Radiol ; 36(1): 105-10, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22414984

RESUMEN

PURPOSE: Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection. METHODS: Twenty-three subjects with unresectable liver tumors, who were scheduled for protective occlusion of the GDA before radioembolization therapy, were included. The primary end point was to achieve a proximal occlusion of the GDA with only one detachable HydroCoil. Evaluated parameters were duration of deployment, and early (during the intervention) and late (7-21 days) occlusion rates of GDA. Secondary end points included complete duration of the intervention, amount of contrast medium used, fluoroscopy rates, and adverse effects. RESULTS: In all cases, the GDA was successfully occluded with only one HydroCoil. The selected diameter/length range was 4/10 mm in 2 patients, 4/15 mm in 6 patients, and 4/20 mm in 15 patients. HydroCoils were implanted, on average, 3.75 mm from the origin of the GDA (range 1.5-6.8 mm), with an average deployment time of 2:47 (median 2:42, range 2:30-3:07) min. In 21 (91%) of 23 patients, a complete occlusion of the GDA was achieved during the first 30 min after the coil implantation; however, in all patients, a late occlusion of the GDA was present after 6 to 29 days. No clinical or technical complications were reported. CONCLUSION: We demonstrated that occlusion of the GDA with a single HydroCoil is a safe procedure and successfully prevents extrahepatic embolization before radioembolization.


Asunto(s)
Arteriopatías Oclusivas/prevención & control , Embolización Terapéutica/instrumentación , Arteria Ilíaca/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Radiografía Intervencional/métodos , Terapia Recuperativa/métodos , Adulto , Angiografía/métodos , Estudios de Cohortes , Duodeno/irrigación sanguínea , Embolización Terapéutica/métodos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/radioterapia , Masculino , Persona de Mediana Edad , Proyectos Piloto , Prevención Primaria/métodos , Implantación de Prótesis/métodos , Radiografía Intervencional/instrumentación , Medición de Riesgo , Stents , Estómago/irrigación sanguínea , Tasa de Supervivencia , Resultado del Tratamiento
4.
Herzschrittmacherther Elektrophysiol ; 22(4): 233-6, 239-42, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22127540

RESUMEN

AIMS: We report our experience concerning lead performance and re-surgery rate of the Medtronic EnRhythm MRI SureScan pacemaker system (MRI-PM) in comparison to standard pacemaker (PM) systems and leads used at our institution. METHODS: All patients (except patients with transvenous left ventricular leads) with successful PM implantation performed at our institution from 1 March 2009 to 31 October 2009 were included in this analysis and followed until mid January 2010. Lead measurements (assessed at implantation, prehospital discharge interrogation (1st follow-up) and at the first scheduled out-patient follow-up (2nd follow-up) were compared between atrial leads 4592-53 cm and 5086MRI-52 cm (lead group 1), and between ventricular leads 4092-58 cm and 5086MRI-52 cm/-58 cm (lead group 2), respectively. Causes for re-operations were assessed and compared between patients with standard dual chamber PM (DC-PM) and the MRI-PM. RESULTS: A total of 140 patients (VVI-PM: 36 patients; DDD-PM: 102 patients; biventricular PM: 1 patient) were successfully implanted with a PM within the implantation period. Two patients with transvenous left ventricular leads were excluded from further analysis. In an atrial position, lead 4592 was implanted in 51 patients and lead 5086MRI-52 cm was implanted in 40 patients, respectively. Ventricular leads were lead 4092-58 cm (64 patients) and lead 5086MRI (41 patients), respectively. Patients were followed for 26 ± 11 weeks. Comparison of lead measurements of lead group 1 showed significant differences for pacing impedance and pacing threshold at implantation, and for sensing at the 2nd follow-up. Comparison of lead measurements within lead group 2 showed significant differences for pacing impedance at implantation, for pacing threshold at the 1st follow-up, and for sensing, pacing threshold, and impedance at the 2nd follow-up. All assessed mean values were favorable for all leads at any follow-up. The number of re-operations was high in both dual chamber PM groups, but did not differ significantly between the two groups (DC-PM: 5 patients, 8.5%; MRI-PM: 5 patients, 13.2%). CONCLUSION: Our study demonstrates favorable lead measurements of lead model 5086MRI in comparison to lead 4592 and 4092 in a short-term follow-up. The number of re-operations was higher in the MRI-PM group, but not statistically different in comparison with the standard dual chamber PM group.


Asunto(s)
Falla de Equipo/estadística & datos numéricos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Implantación de Prótesis/estadística & datos numéricos , Anciano , Austria/epidemiología , Quemaduras/epidemiología , Comorbilidad , Electrodos Implantados , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Incidencia , Masculino , Reoperación , Estudios Retrospectivos , Medición de Riesgo
5.
Radiologe ; 50(12): 1120, 1122-7, 2010 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-20844858

RESUMEN

The rapid technical advances in computed tomography have led to an increased number of clinical indications. Unfortunately, at the same time the radiation exposure to the population has also increased due to the increased total number of CT examinations. In the last few years various publications have demonstrated the feasibility of radiation dose reduction for CT examinations with no compromise in image quality and loss in interpretation accuracy. The majority of the proposed methods for dose optimization are easy to apply and are independent of the detector array configuration. This article reviews indication-dependent principles (e.g. application of reduced tube voltage for CT angiography, selection of the collimation and the pitch, reducing the total number of imaging series, lowering the tube voltage and tube current for non-contrast CT scans), manufacturer-dependent principles (e.g. accurate application of automatic modulation of tube current, use of adaptive image noise filter and use of iterative image reconstruction) and general principles (e.g. appropriate patient-centering in the gantry, avoiding over-ranging of the CT scan, lowering the tube voltage and tube current for survey CT scans) which lead to radiation dose reduction.


Asunto(s)
Angiografía/efectos adversos , Angiografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Humanos , Radiometría/métodos , Tecnología Radiológica/métodos
7.
Eur Respir J ; 35(4): 812-20, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19840956

RESUMEN

The aim of the present study was to better understand previously reported changes in lung function at high altitude. Comprehensive pulmonary function testing utilising body plethysmography and assessment of changes in closing volume were carried out at sea level and repeatedly over 2 days at high altitude (4,559 m) in 34 mountaineers. In subjects without high-altitude pulmonary oedema (HAPE), there was no significant difference in total lung capacity, forced vital capacity, closing volume and lung compliance between low and high altitude, whereas lung diffusing capacity for carbon monoxide increased at high altitude. Bronchoconstriction at high altitude could be excluded as the cause of changes in closing volume because there was no difference in airway resistance and bronchodilator responsiveness to salbutamol. There were no significant differences in these parameters between mountaineers with and without acute mountain sickness. Mild alveolar oedema on radiographs in HAPE was associated only with minor decreases in forced vital capacity, diffusing capacity and lung compliance and minor increases in closing volume. Comprehensive lung function testing provided no evidence of interstitial pulmonary oedema in mountaineers without HAPE during the first 2 days at 4,559 m. Data obtained in mountaineers with early mild HAPE suggest that these methods may not be sensitive enough for the detection of interstitial pulmonary fluid accumulation.


Asunto(s)
Mal de Altura/diagnóstico , Mal de Altura/fisiopatología , Altitud , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatología , Enfermedad Aguda , Adulto , Resistencia de las Vías Respiratorias , Femenino , Humanos , Rendimiento Pulmonar , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad , Modelos Biológicos , Montañismo , Pletismografía , Pruebas de Función Respiratoria , Espirometría , Capacidad Vital
8.
Eur Radiol ; 17(6): 1621-33, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17072616

RESUMEN

A nationwide survey was launched to investigate the use of fluoroscopy and establish national reference levels (RL) for dose-intensive procedures. The 2-year investigation covered five radiology and nine cardiology departments in public hospitals and private clinics, and focused on 12 examination types: 6 diagnostic and 6 interventional. A total of 1,000 examinations was registered. Information including the fluoroscopy time (T), the number of frames (N) and the dose-area product (DAP) was provided. The data set was used to establish the distributions of T, N and the DAP and the associated RL values. The examinations were pooled to improve the statistics. A wide variation in dose and image quality in fixed geometry was observed. As an example, the skin dose rate for abdominal examinations varied in the range of 10 to 45 mGy/min for comparable image quality. A wide variability was found for several types of examinations, mainly complex ones. DAP RLs of 210, 125, 80, 240, 440 and 110 Gy cm2 were established for lower limb and iliac angiography, cerebral angiography, coronary angiography, biliary drainage and stenting, cerebral embolization and PTCA, respectively. The RL values established are compared to the data published in the literature.


Asunto(s)
Fluoroscopía/normas , Radiometría/métodos , Diagnóstico por Imagen/normas , Relación Dosis-Respuesta en la Radiación , Humanos , Dosis de Radiación , Radiografía Intervencional/normas , Valores de Referencia , Piel/efectos de la radiación , Suiza
9.
Med Phys ; 33(10): 3637-9, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17089829

RESUMEN

In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.


Asunto(s)
Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Rayos Láser , Radiometría , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Espectrometría por Rayos X
10.
Ther Umsch ; 63(10): 639-45, 2006 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-17048182

RESUMEN

From conventional radiography to cross-sectional imaging methods, modern radiology offers a wide range of diagnostic tools for investigating patients with fever. To achieve the best results and to yield a correct diagnosis, the radiologist must tailor the diagnostic protocol individually for every patient. The decision on the most suitable imaging method, and the type and timing of contrast media strongly depends on the suspected diagnosis. Based on patient history and laboratory data, some modalities may be contraindicated or the patient may need a premedication. The authors give a short overview of diagnostic strategies in evaluating the most important causes of fever and point to the need of discussion and co-operation between clinicians and radiologists.


Asunto(s)
Diagnóstico por Imagen , Fiebre de Origen Desconocido/etiología , Medios de Contraste/administración & dosificación , Conducta Cooperativa , Diagnóstico Diferencial , Humanos , Anamnesis , Grupo de Atención al Paciente , Sensibilidad y Especificidad
11.
Kidney Int ; 70(1): 144-50, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16641929

RESUMEN

Hypoxia of renal medulla is a key factor implicated in the development of drug-induced renal failure. Drugs are known to influence renal hemodynamics and, subsequently, affect renal tissue oxygenation. Changes in renal oxygenation can be assessed non-invasively in humans using blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI). This study was designed to test the acute effects of administration of specific drugs in healthy human kidney oxygenation using BOLD-MRI. Acute changes in renal tissue oxygenation induced by the non-steroidal anti-inflammatory drug indomethacin, the iodinated radio-contrast media (RCM) iopromidum, and the calcineurin inhibitors cyclosporine micro-emulsion (CsA-ME) and tracrolimus were studied in 30 healthy volunteers. A modified Multi Echo Data Image Combination sequence was used to acquire 12 T(2)(*)-weighted images. Four coronal slices were selected to cover both kidneys. The mean R(2)(*) (1/T(2)(*)) values determined in medulla and cortex showed no significant changes induced by indomethacin and tacrolimus administration. CsA-ME decreased medullary (P=0.008) and cortical (P=0.004) R(2)(*) values 2 h after ingestion. Iopromidum caused a significant increase in medullary R(2)(*) within the first 20 min after injection (P<0.001), whereas no relevant changes were observed in renal cortex. None of the measurements showed left-right kidney differences. Significant differences in renal medullary oxygenation were evidenced between female and male subjects (P=0.013). BOLD-MRI was efficient to show effects of specific drugs in healthy renal tissue. Cyclosporine increased renal medullary oxygenation 2 h after ingestion of a single dose, whereas indomethacin and tacrolimus showed no effect on renal oxygenation. Injection of iodinated RCM decreased renal medullary oxygenation.


Asunto(s)
Médula Renal/irrigación sanguínea , Médula Renal/efectos de los fármacos , Imagen por Resonancia Magnética/métodos , Oxígeno/sangre , Xenobióticos/administración & dosificación , Adolescente , Adulto , Respiración de la Célula/efectos de los fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/efectos de los fármacos , Xenobióticos/toxicidad
12.
Med Phys ; 33(2): 411-20, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16532949

RESUMEN

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.


Asunto(s)
Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Niño , Análisis de Falla de Equipo , Humanos , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Radiometría , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Espectrometría por Rayos X
13.
Int J Legal Med ; 120(4): 233-40, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16328426

RESUMEN

The rapid development of computed tomography (CT) and magnetic resonance imaging (MRI) led to the introduction and establishment in postmortem investigations. The objectives of this preliminary study were to describe the imaging appearances of the early postmortem changes of blood after cessation of the circulation, such as sedimentation, postmortem clotting, and internal livores, and to give a few first suggestions on how to differentiate them from other forensic findings. In the Virtopsy project, 95 human corpses underwent postmortem imaging by CT and MRI prior to traditional autopsy and therefore 44 cases have been investigated in this study. Postmortem alterations as well as the forensic relevant findings of the blood, such as internal or subcutaneous bleedings, are presented on the basis of their imaging appearances in multislice CT and MRI.


Asunto(s)
Circulación Sanguínea , Patologia Forense , Imagen por Resonancia Magnética , Cambios Post Mortem , Tomografía Computarizada por Rayos X/métodos , Aorta/patología , Coagulación Sanguínea , Sedimentación Sanguínea , Atrios Cardíacos/patología , Ventrículos Cardíacos/patología , Humanos , Hígado/irrigación sanguínea , Hígado/patología , Pulmón/irrigación sanguínea , Pulmón/patología , Arteria Pulmonar/patología
14.
Neuroradiology ; 47(10): 721-9, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16136264

RESUMEN

Decisions about the treatment of neck pain are largely made on the basis of information gained from plain X-rays and magnetic resonance imaging (MRI), which are used routinely as part of preliminary investigation. We performed a descriptive cadaveric study to compare histology with radiography and MRI. We correlated plain radiography, disc height [Farfan index (FI)] and MRI findings with histology to assess the ability of radiology to detect significant pathologic lesions. The study included 52 motion segments from nine subjects over the age of 50, who underwent routine hospital autopsy. Disc degeneration was assessed by histology, radiography, disc height (FI: anterior disc height plus posterior disc height divided by anterioposterior diameter) and MRI using established grading systems. Most of the discs were classified radiologically as grade 1 (19/52), grade 2 (13/52), grade 3 (9/52) or grade 4 (3/52). Eight of the discs were graded as normal. The distribution of MRI grades was grade 0 (9/36), grade 1 (9/36), grade 2 (7/36), grade 3 (8/36) and grade 4 (3/36). Half of the discs (26/52) showed advanced (grade 4) degeneration histologically. FI correlated with histological grade (P = 0.013), MRI grade (P = 0.02) and radiological grade (P < 0.001) of degeneration. Radiological and histological grade of degeneration showed a weak correlation (r = 0.3, P = 0.033). MRI correlated with overall histological grade (r = 0.41, P = 0.015, n = 34). Histological features (e.g., tears, rim lesions, prolapse of nucleus material) were poorly recognised by MRI, which had a sensitivity for disc material prolapse and annulus tears of less than 40%. Our study showed that discs from patients over 50 years are histologically severely degenerated; however, these changes may not be detected by conventional radiography and MRI.


Asunto(s)
Vértebras Cervicales , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/patología , Imagen por Resonancia Magnética , Anciano , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía
15.
Radiat Prot Dosimetry ; 114(1-3): 188-91, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15933106

RESUMEN

The purpose of this study is to present a strategy to define the reference dose levels for fluoroscopic, dose-intensive examinations. This work is a part of the project of the Federal Office of Public Health of Switzerland to translate the guidelines of the International Commission on Radiological Protection and the European Union into action. The study will also be used to set reference dose levels on the basis of a national survey. All the fluoroscopic units, involved in the survey, were equipped with a KAP (kerma-area product) meter. All KAP meters were first calibrated to ensure the comparability of the dose measurements. The doses and the dose rates together with subjective image quality measurements were acquired in all the centres. Eight types of examination were chosen by a panel of radiologists, and each of the five centres involved agreed to monitor 20 patients per examination type. A wide variation in the dose and the image quality in fixed geometry was observed. For example, the skin dose rate for abdominal examinations varied in the range of 12-42 mGy min(-1) for comparable image quality. Average KAP values of 67, 178, 106, 102, 473, 205, 307 and 316 Gy cm2 were recorded for barium meal, abdominal angiography, cerebral angiography, barium enema, hepatic embolisation, biliary drainage, cerebral embolisation and femoral stenting, respectively. The values obtained in this limited study are generally higher than the ones available in the literature and strategies to optimise these studies have to be discussed. A strict control concerning the denomination of the examination type involved in such a study is mandatory to obtain reliable data. This can only be done through a close collaboration between physicians, radiographers and medical physicists.


Asunto(s)
Diagnóstico por Imagen/métodos , Fluoroscopía/métodos , Fluoroscopía/normas , Radiología Intervencionista/métodos , Radiometría/métodos , Angiografía/métodos , Diagnóstico por Imagen/normas , Relación Dosis-Respuesta en la Radiación , Humanos , Dosis de Radiación , Intensificación de Imagen Radiográfica , Radiología Intervencionista/normas , Radiometría/instrumentación , Estándares de Referencia , Suiza
16.
Skeletal Radiol ; 34(5): 279-84, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15586281

RESUMEN

OBJECTIVE: To determine the incidence of Harris lines in two medieval populations which inhabited the Canton of Berne, in Central Switzerland, and to compare the results with those of a contemporary population living in the same geographical area. A simplified method is described for measuring the age of the individual at the time of formation of Harris lines, with possible future applications. DESIGN AND PATIENTS: Radiographs of 112 well-preserved tibiae of skeletons of two medieval populations from the eighth to fifteenth centuries were reviewed for the incidence of Harris lines. The results were compared with those of 138 current patients living in the same geographic location in Central Switzerland. Age and gender of the medieval individual were determined using known anthropological methods. Age of bone at the time of formation of Harris lines was estimated according to the method of Maat. RESULTS: Harris lines were found in 88 of 112 (80%) of the examined medieval skeletons and in 28 of 138 (20%) of the living individuals. Higher incidences of Harris lines were found at the age of 2 years and at ages between 8 and 12 years in both populations. No gender difference was found regarding the incidence of Harris lines. In both populations the occurrence of Harris lines was associated with certain diseases such as degenerative bone disease, trauma, osteoporosis, rheumatoid arthritis, peripheral vascular diseases, rickets and bony deformities. CONCLUSION: A high incidence of Harris lines was found in the medieval population, perhaps reflecting difficult living and hygienic conditions, but also the poor care and neglect of the children population. Measuring the age of the individual at the time of formation of Harris lines is simple and may have future clinical applications in the paediatric population for medico-legal purposes. The application of Harris lines as a marker in follow-up of osteoporosis may need further evaluation.


Asunto(s)
Tibia/crecimiento & desarrollo , Tibia/patología , Adolescente , Adulto , Determinación de la Edad por el Esqueleto , Antropometría , Niño , Preescolar , Femenino , Estado de Salud , Historia Medieval , Humanos , Lactante , Masculino , Persona de Mediana Edad , Paleopatología , Suiza
17.
Ther Umsch ; 61(11): 665-70, 2004 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-15605459

RESUMEN

The most common causes of pulmonary edema are cardiac failure, renal failure and injury edema (diffuse alveolar damage). The injury edema typically shows airspace consolidation due to exsudation of fluid in the periphery of the lung with air bronchograms, no interstitial fluid accumulation can be found and only rarely pleural effusions are present. Cardiac and renal edemas often show a mixed interstitial and alveolar transudation without air bronchograms. Pleural effusions are often present. Both usually have an increased heart-size and an increased vascular pedicle width. To distinguish them better one has to look at the distribution of the pulmonary edema: The cardiac edema typically shows a gravitational and the renal edema a central distribution.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico por imagen , Alveolos Pulmonares/irrigación sanguínea , Edema Pulmonar/diagnóstico por imagen , Insuficiencia Renal/diagnóstico por imagen , Broncografía , Permeabilidad Capilar/fisiología , Diagnóstico Diferencial , Edema Cardíaco/diagnóstico por imagen , Edema Cardíaco/etiología , Insuficiencia Cardíaca/complicaciones , Humanos , Derrame Pleural/diagnóstico por imagen , Derrame Pleural/etiología , Alveolos Pulmonares/lesiones , Edema Pulmonar/etiología , Insuficiencia Renal/complicaciones , Factores de Riesgo , Tomografía Computarizada por Rayos X
18.
Ther Umsch ; 61(9): 557-62, 2004 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-15493115

RESUMEN

Imaging plays a key role in two longterm effects of hyperuricemia: those on the urinary tract and on the skeletal system. This overview concentrates on the diagnosis of urinary stones and of musculoskeletal gout. Urinary stones are negative on radiography, i.e., they cannot be differentiated from the surrounding tissues, and even at intravenous urography only non specific filling defects are shown that may be hard to differentiate from blood clots and papillary necrosis whereas computed tomography without a contrast agent is highly sensitive in detecting all types of stones whether negative or positive at radiography. Gout of the musculoskeletal system usually manifests as an acute gouty arthritis after a long-standing asymptomatic hyperuricemia. An intercritical phase may follow before new acute attacks and--in up to 50%--chronic gout develop. During acute gouty arthritis imaging is non-specific. The distribution pattern, the relation of soft tissue changes and osteolytic paraarticular changes, calcifications and the lack of osteoporosis are a typical, nearly pathognomonic constellation of chronic tophaceous gout. In selected cases CT or MRI may add critical local information.


Asunto(s)
Diagnóstico por Imagen , Gota/diagnóstico , Hiperuricemia/diagnóstico , Artritis Gotosa/sangre , Artritis Gotosa/diagnóstico , Diagnóstico Diferencial , Gota/sangre , Humanos , Hiperuricemia/sangre , Articulaciones/patología , Riñón/patología , Cálculos Renales/sangre , Cálculos Renales/diagnóstico , Pruebas de Función Renal , Sensibilidad y Especificidad , Ácido Úrico/sangre
20.
Forensic Sci Int ; 134(2-3): 109-14, 2003 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-12850403

RESUMEN

It is impossible to obtain a representative anatomical documentation of an entire body using classical X-ray methods, they subsume three-dimensional bodies into a two-dimensional level. We used the novel multislice-computed tomography (MSCT) technique in order to evaluate a case of homicide with putrefaction of the corpse before performing a classical forensic autopsy. This non-invasive method showed gaseous distension of the decomposing organs and tissues in detail as well as a complex fracture of the calvarium. MSCT also proved useful in screening for foreign matter in decomposing bodies, and full-body scanning took only a few minutes. In conclusion, we believe postmortem MSCT imaging is an excellent vizualisation tool with great potential for forensic documentation and evaluation of decomposed bodies.


Asunto(s)
Autopsia/métodos , Interpretación de Imagen Asistida por Computador , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Cambios Post Mortem , Tomografía Computarizada por Rayos X/métodos , Medicina Legal/métodos , Gases , Homicidio , Humanos , Fracturas Craneales/patología