Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur J Vasc Endovasc Surg ; 50(1): 13-20, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26021529

RESUMEN

OBJECTIVES: Endovascular treatment of atherosclerotic obstruction of aortic arch branch origins (AABO) has largely replaced open surgery, but long-term outcome data are lacking. This study evaluated mid-term and long-term results of these procedures. DESIGN: Retrospective cohort study. MATERIALS AND METHODS: Patients underwent endovascular treatment for symptomatic atherosclerotic stenosis of AABO between 1995 and 2012. Technical success was defined as uncomplicated revascularization and residual stenosis ≤30%. The primary end point was freedom from restenosis ≥50% on Duplex ultrasonography or magnetic resonance angiography. Secondary end points were freedom from target lesion revascularization or recurrent symptoms. RESULTS: 144 lesions were treated in 114 patients (75 female; mean age 66.3 years), by percutaneous transluminal angioplasty (PTA) in 20 patients and PTA and stent in 117 patients (brachiocephalic artery [BCA] 9/54; left common carotid artery [LCCA] 0/7; left subclavian artery [LSA] 11/56). The lesion could not be passed in four patients, and in three patients the intervention was terminated before angioplasty. The 30-day technical success was 94.4%, without deaths or strokes. Mean follow-up was 52.0 months (range 2-163 months). Restenosis-free survival was 95.6%, 92.9%, 87.6%, and 83.2% at 12, 24, 48, and 60 months, respectively. Log-rank test showed no significant difference between PTA only and PTA with additional stent placement at any point (p = .375), nor between BCA (n = 51), LCCA (n = 6), or LSA (n = 57). During follow-up, 27 patients (23.7%) became symptomatic (15 BCA, 1 LCCA, and 11 LSA); 19 patients with a restenosis of the target lesion (mean 56.7 months). Symptom-free survival was 94.7%, 92.0%, 82.3%, and 77.9% at 12, 24, 48, and 60 months, respectively. CONCLUSION: Endovascular treatment of aortic arch branch origin obstruction is safe and efficacious in experienced hands and can be considered as the preferred treatment, with good mid-term durability. Recurrent symptomatic lesions can be treated safely by renewed endovascular means.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta/cirugía , Aterosclerosis/cirugía , Procedimientos Endovasculares , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inducción de Remisión , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
2.
Br J Radiol ; 85(1017): e616-21, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22919014

RESUMEN

OBJECTIVES: Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions. METHODS: PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml(-1)) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml(-1)). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs. RESULTS: Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383-494) and 288±41 Hounsfield units (range 202-367), respectively. CONCLUSIONS: PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction.


Asunto(s)
Válvula Aórtica/cirugía , Aortografía , Prótesis Valvulares Cardíacas/efectos adversos , Hemorragia/diagnóstico por imagen , Hemorragia/etiología , Suturas , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Animales , Diagnóstico Diferencial , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Técnicas In Vitro , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA