1.
Radiol Cardiothorac Imaging ; 6(4): e230331, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38990132

RESUMEN

Purpose To compare parameters of left ventricular (LV) and right ventricular (RV) volume and function between a commercially available 0.55-T low-field-strength cardiac cine MRI scanner and a 1.5-T scanner. Materials and Methods In this prospective study, healthy volunteers (May 2022 to July 2022) underwent same-day cine imaging using both scanners (0.55 T, 1.5 T). Volumetric and functional parameters were assessed by two experts. After analyzing the results of a blinded crossover reader study of the healthy volunteers, 20 participants with clinically indicated cardiac MRI were prospectively included (November 2022 to February 2023). In a second blinded expert reading, parameters from clinical 1.5-T scans in these participants were compared with those same-day 0.55-T scans. Results are displayed as Bland-Altman plots. Results Eleven healthy volunteers (mean age: 33 years [95% CI: 27, 40]; four of 11 [36%] female, seven of 11 [64%] male) were included. Very strong mean correlation was observed (r = 0.98 [95% CI: 0.97, 0.98]). Average deviation between MRI systems was 1.6% (95% CI: 0.3, 2.9) for both readers. Twenty participants with clinically indicated cardiac MRI were included (mean age: 55 years [95% CI: 48, 62], six of 20 [30%] female, 14 of 20 [70%] male). Mean correlation was very strong (r = 0.98 [95% CI: 0.97, 0.98]). LV and RV parameters demonstrated an average deviation of 1.1% (95% CI: 0.1, 2.1) between MRI systems. Conclusion Cardiac cine MRI at 0.55 T yielded comparable results for quantitative biventricular volumetric and functional parameters compared with routine imaging at 1.5 T, if acquisition time is doubled. Keywords: Cardiac, Comparative Studies, Heart, Cardiovascular MRI, Cine, Myocardium Supplemental material is available for this article. ©RSNA, 2024.


Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Cinemagnética/instrumentación , Femenino , Masculino , Adulto , Estudios Prospectivos , Ventrículos Cardíacos/diagnóstico por imagen , Voluntarios Sanos , Estudios Cruzados
2.
Invest Radiol ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38857414

RESUMEN

OBJECTIVES: The aim of this study was to compare deep learning reconstructed (DLR) 0.55 T magnetic resonance imaging (MRI) quality, identification, and grading of structural anomalies and reader confidence levels with conventional 3 T knee MRI in patients with knee pain following trauma. MATERIALS AND METHODS: This prospective study of 26 symptomatic patients (5 women) includes 52 paired DLR 0.55 T and conventional 3 T MRI examinations obtained in 1 setting. A novel, commercially available DLR algorithm was employed for 0.55 T image reconstruction. Four board-certified radiologists reviewed all images independently and graded image quality, noted structural anomalies and their respective reporting confidence levels for the presence or absence, as well as grading of bone, cartilage, meniscus, ligament, and tendon lesions. Image quality and reader confidence levels were compared (P < 0.05, significant), and MRI findings were correlated between 0.55 T and 3 T MRI using Cohen kappa (κ). RESULTS: In reader's consensus, good image quality was found for DLR 0.55 T MRI and 3 T MRI (3.8 vs 4.1/5 points, P = 0.06). There was near-perfect agreement between 0.55 T DLR and 3 T MRI regarding the identification of structural anomalies for all readers (each κ ≥ 0.80). Substantial to near-perfection agreement between 0.55 T and 3 T MRI was reported for grading of cartilage (κ = 0.65-0.86) and meniscus lesions (κ = 0.71-1.0). High confidence levels were found for all readers for DLR 0.55 T and 3 T MRI, with 3 readers showing higher confidence levels for reporting cartilage lesions on 3 T MRI. CONCLUSIONS: In conclusion, new-generation 0.55 T DLR MRI provides good image quality, comparable to conventional 3 T MRI, and allows for reliable identification of internal derangement of the knee with high reader confidence.

3.
Radiologie (Heidelb) ; 2024 Jun 12.
Artículo en Alemán | MEDLINE | ID: mdl-38864874

RESUMEN

CLINICAL/METHODICAL ISSUE: Magnetic resonance imaging (MRI) is a central component of musculoskeletal imaging. However, long image acquisition times can pose practical barriers in clinical practice. STANDARD RADIOLOGICAL METHODS: MRI is the established modality of choice in the diagnostic workup of injuries and diseases of the musculoskeletal system due to its high spatial resolution, excellent signal-to-noise ratio (SNR), and unparalleled soft tissue contrast. METHODOLOGICAL INNOVATIONS: Continuous advances in hardware and software technology over the last few decades have enabled four-fold acceleration of 2D turbo-spin-echo (TSE) without compromising image quality or diagnostic performance. The recent clinical introduction of deep learning (DL)-based image reconstruction algorithms helps to minimize further the interdependency between SNR, spatial resolution and image acquisition time and allows the use of higher acceleration factors. PERFORMANCE: The combined use of advanced acceleration techniques and DL-based image reconstruction holds enormous potential to maximize efficiency, patient comfort, access, and value of musculoskeletal MRI while maintaining excellent diagnostic accuracy. ACHIEVEMENTS: Accelerated MRI with DL-based image reconstruction has rapidly found its way into clinical practice and proven to be of added value. Furthermore, recent investigations suggest that the potential of this technology does not yet appear to be fully harvested. PRACTICAL RECOMMENDATIONS: Deep learning-reconstructed fast musculoskeletal MRI examinations can be reliably used for diagnostic work-up and follow-up of musculoskeletal pathologies in clinical practice.

4.
Eur J Radiol Open ; 12: 100567, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38711678

RESUMEN

Objectives: To evaluate an optimized deep leaning-based image post-processing technique in lumbar spine MRI at 0.55 T in terms of image quality and image acquisition time. Materials and methods: Lumbar spine imaging was conducted on 18 patients using a 0.55 T MRI scanner, employing conventional (CDLR) and advanced (ADLR) deep learning-based post-processing techniques. Two musculoskeletal radiologists visually evaluated the images using a 5-point Likert scale to assess image quality and resolution. Quantitative assessment in terms of signal intensities (SI) and contrast ratios was performed by region of interest measurements in different body-tissues (vertebral bone, intervertebral disc, spinal cord, cerebrospinal fluid and autochthonous back muscles) to investigate differences between CDLR and ADLR sequences. Results: The images processed with the advanced technique (ADLR) were rated superior to the conventional technique (CDLR) in terms of signal/contrast, resolution, and assessability of the spinal canal and neural foramen. The interrater agreement was moderate for signal/contrast (ICC = 0.68) and good for resolution (ICC = 0.77), but moderate for spinal canal and neuroforaminal assessability (ICC = 0.55). Quantitative assessment showed a higher contrast ratio for fluid-sensitive sequences in the ADLR images. The use of ADLR reduced image acquisition time by 44.4%, from 14:22 min to 07:59 min. Conclusions: Advanced deep learning-based image reconstruction algorithms improve the visually perceived image quality in lumbar spine imaging at 0.55 T while simultaneously allowing to substantially decrease image acquisition times. Clinical relevance: Advanced deep learning-based image post-processing techniques (ADLR) in lumbar spine MRI at 0.55 T significantly improves image quality while reducing image acquisition time.

5.
Radiology ; 311(1): e240588, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38652029

RESUMEN

Supplemental material is available for this article. See also the article by Lenkinski and Rofsky in this issue. See also the article by McKee et al in this issue.


Asunto(s)
Gases de Efecto Invernadero , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/economía
6.
AJR Am J Roentgenol ; 222(6): e2430988, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38506540

RESUMEN

BACKGROUND. The energy demand of interventional imaging systems has historically been estimated using manufacturer-provided specifications rather than directly measured. OBJECTIVE. The purpose of this study was to investigate the energy consumption of interventional imaging systems and estimate potential savings in the carbon emissions and electricity costs of such systems through hypothetical operational adjustments. METHODS. An interventional radiology suite, neurointerventional suite, radiology fluoroscopy unit, two cardiology laboratories, and two urology fluoroscopy units were equipped with power sensors. Power measurement logs were extracted for a single 4-week period for each radiology and cardiology system (all between June 1, 2022, and November 28, 2022) and for the 2-week period from July 31, 2023, to August 13, 2023, for each urology system. Power statuses, procedure time stamps, and fluoroscopy times were extracted from various sources. System activity was divided into off, idle (no patient in room), active (patient in room for procedure), and net-imaging (active fluoroscopic image acquisition) states. Projected annual energy consumption was calculated. Potential annual savings in carbon emissions and electricity costs through hypothetical operational adjustments were estimated using published values for Switzerland. RESULTS. Across the seven systems, the mean power draw was 0.3-1.1, 0.7-7.4, 0.9-7.6, and 1.9-12.5 kW in the off, idle, active, and net-imaging states, respectively. Across systems, the off state, in comparison with the idle state, showed a decrease in the mean power draw of 0.2-6.9 kW (relative decrease, 22.2-93.2%). The systems had a combined projected annual energy consumption of 115,684 kWh (range, 3646-26,576 kWh per system). The systems' combined projected energy consumption occurring outside the net-imaging state accounted for 93.3% (107,978/115,684 kWh) of projected total energy consumption (range, 89.2-99.4% per system). A hypothetical operational adjustment whereby all systems would be switched from the idle state to the off state overnight and on weekends (versus being operated in idle mode 24 hours a day, 7 days a week) would yield the following potential annual savings: for energy consumption, 144,640 kWh; for carbon emissions, 18.6 metric tons of CO2 equivalent; and for electricity costs, US$37,896. CONCLUSION. Interventional imaging systems are energy intensive, having high consumption outside of image acquisition periods. CLINICAL IMPACT. Strategic operational adjustments (e.g., powering down idle systems) can substantially decrease the carbon emissions and electricity costs of interventional imaging systems.


Asunto(s)
Radiografía Intervencional , Humanos , Radiografía Intervencional/economía , Fluoroscopía/economía , Urología/economía , Cardiología/economía , Electricidad , Huella de Carbono
7.
Skeletal Radiol ; 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38441617

RESUMEN

Magnetic resonance imaging (MRI) is crucial for accurately diagnosing a wide spectrum of musculoskeletal conditions due to its superior soft tissue contrast resolution. However, the long acquisition times of traditional two-dimensional (2D) and three-dimensional (3D) fast and turbo spin-echo (TSE) pulse sequences can limit patient access and comfort. Recent technical advancements have introduced acceleration techniques that significantly reduce MRI times for musculoskeletal examinations. Key acceleration methods include parallel imaging (PI), simultaneous multi-slice acquisition (SMS), and compressed sensing (CS), enabling up to eightfold faster scans while maintaining image quality, resolution, and safety standards. These innovations now allow for 3- to 6-fold accelerated clinical musculoskeletal MRI exams, reducing scan times to 4 to 6 min for joints and spine imaging. Evolving deep learning-based image reconstruction promises even faster scans without compromising quality. Current research indicates that combining acceleration techniques, deep learning image reconstruction, and superresolution algorithms will eventually facilitate tenfold accelerated musculoskeletal MRI in routine clinical practice. Such rapid MRI protocols can drastically reduce scan times by 80-90% compared to conventional methods. Implementing these rapid imaging protocols does impact workflow, indirect costs, and workload for MRI technologists and radiologists, which requires careful management. However, the shift from conventional to accelerated, deep learning-based MRI enhances the value of musculoskeletal MRI by improving patient access and comfort and promoting sustainable imaging practices. This article offers a comprehensive overview of the technical aspects, benefits, and challenges of modern accelerated musculoskeletal MRI, guiding radiologists and researchers in this evolving field.

8.
Radiology ; 310(2): e232030, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38411520

RESUMEN

According to the World Health Organization, climate change is the single biggest health threat facing humanity. The global health care system, including medical imaging, must manage the health effects of climate change while at the same time addressing the large amount of greenhouse gas (GHG) emissions generated in the delivery of care. Data centers and computational efforts are increasingly large contributors to GHG emissions in radiology. This is due to the explosive increase in big data and artificial intelligence (AI) applications that have resulted in large energy requirements for developing and deploying AI models. However, AI also has the potential to improve environmental sustainability in medical imaging. For example, use of AI can shorten MRI scan times with accelerated acquisition times, improve the scheduling efficiency of scanners, and optimize the use of decision-support tools to reduce low-value imaging. The purpose of this Radiology in Focus article is to discuss this duality at the intersection of environmental sustainability and AI in radiology. Further discussed are strategies and opportunities to decrease AI-related emissions and to leverage AI to improve sustainability in radiology, with a focus on health equity. Co-benefits of these strategies are explored, including lower cost and improved patient outcomes. Finally, knowledge gaps and areas for future research are highlighted.


Asunto(s)
Inteligencia Artificial , Radiología , Humanos , Radiografía , Macrodatos , Cambio Climático
9.
Acad Radiol ; 31(6): 2456-2463, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38242732

RESUMEN

RATIONALE AND OBJECTIVES: To compare image quality and metal artifact severity at 0.55 T and 1.5 T MRI in patients with spinal implants following posterior fusion surgery. MATERIALS AND METHODS: 50 consecutive patients (mean age: 69 ±â€¯12 years) who underwent 0.55 T and 1.5 T MRI following posterior fusion surgery of the lumbar or thoracolumbar spine were included. Examinations used metal artifact reduction protocols from clinical routine. Images were rated by two fellowship-trained musculoskeletal radiologists for image quality, ability to assess the spinal canal and the neural foramina, and artifact severity on 5-point Likert scales. Additionally, differences in artifact severity and visibility of near-metal anatomy among implant sizes (1-level vs. 2-level vs. >2-levels) were evaluated. RESULTS: Signal/contrast (mean: 4.0 ±â€¯0.3 [0.55 T] vs. 4.4 ±â€¯0.6 [1.5 T]; p < .001) and resolution (3.8 ±â€¯0.5 vs. 4.2 ±â€¯0.7; p < .001) were rated lower at 0.55 T. The ability to assess the spinal canal (4.4 ±â€¯0.5 vs. 4.2 ±â€¯0.9; p = .69) and the neural foramina (3.8 ±â€¯0.5 vs. 3.8 ±â€¯0.9; p = .19) were however rated equally good with excellent interrater agreement (range: 0.84-0.94). Susceptibility artifacts were rated milder at 0.55 T (1.8 ±â€¯0.5 vs. 3.0 ±â€¯0.6; p < .001). For implant size-based subgroups, the visibility of near-metal anatomy decreased with implant length at 1.5 T, but remained unchanged at 0.55 T. In consequence, the spinal canal and neural foramina could be better assessed at 0.55 T in patients with multi-level implants (4.4 ±â€¯0.5 vs. 3.6 ±â€¯1.1; p < .001). CONCLUSION: Metal artifacts of spinal implants are substantially less pronounced at 0.55 T MRI. When examining patients with multi-level posterior fusion, this translates into a superior ability to assess near-metal anatomy, where 1.5 T MRI reaches diagnostic limitations.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Metales , Prótesis e Implantes , Humanos , Imagen por Resonancia Magnética/métodos , Anciano , Femenino , Masculino , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Persona de Mediana Edad
10.
Invest Radiol ; 59(4): 298-305, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37747455

RESUMEN

OBJECTIVES: The aim of this study was to compare the detection rate of and reader confidence in 0.55 T knee magnetic resonance imaging (MRI) findings with 3 T knee MRI in patients with acute trauma and knee pain. MATERIALS AND METHODS: In this prospective study, 0.55 T and 3 T knee MRI of 25 symptomatic patients (11 women; median age, 38 years) with suspected internal derangement of the knee was obtained in 1 setting. On the 0.55 T system, a commercially available deep learning image reconstruction algorithm was used (Deep Resolve Gain and Deep Resolve Sharp; Siemens Healthineers), which was not available on the 3 T system. Two board-certified radiologists reviewed all images independently and graded image quality parameters, noted MRI findings and their respective reporting confidence level for the presence or absence, as well as graded the bone, cartilage, meniscus, ligament, and tendon lesions. Image quality and reader confidence levels were compared ( P < 0.05 = significant), and clinical findings were correlated between 0.55 T and 3 T MRI by calculation of the intraclass correlation coefficient (ICC). RESULTS: Image quality was rated higher at 3 T compared with 0.55 T studies (each P ≤ 0.017). Agreement between 0.55 T and 3 T MRI for the detection and grading of bone marrow edema and fractures, ligament and tendon lesions, high-grade meniscus and cartilage lesions, Baker cysts, and joint effusions was perfect for both readers. Overall identification and grading of cartilage and meniscal lesions showed good agreement between high- and low-field MRI (each ICC > 0.76), with lower agreement for low-grade cartilage (ICC = 0.77) and meniscus lesions (ICC = 0.49). There was no difference in readers' confidence levels for reporting lesions of bone, ligaments, tendons, Baker cysts, and joint effusions between 0.55 T and 3 T (each P > 0.157). Reader reporting confidence was higher for cartilage and meniscal lesions at 3 T (each P < 0.041). CONCLUSIONS: New-generation 0.55 T knee MRI, with deep learning-aided image reconstruction, allows for reliable detection and grading of joint lesions in symptomatic patients, but it showed limited accuracy and reader confidence for low-grade cartilage and meniscal lesions in comparison with 3 T MRI.


Asunto(s)
Traumatismos de la Rodilla , Quiste Poplíteo , Humanos , Femenino , Adulto , Estudios Prospectivos , Quiste Poplíteo/patología , Traumatismos de la Rodilla/diagnóstico por imagen , Traumatismos de la Rodilla/patología , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/patología , Imagen por Resonancia Magnética/métodos
11.
J Magn Reson Imaging ; 59(4): 1149-1167, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37694980

RESUMEN

The environmental impact of magnetic resonance imaging (MRI) has recently come into focus. This includes its enormous demand for electricity compared to other imaging modalities and contamination of water bodies with anthropogenic gadolinium related to contrast administration. Given the pressing threat of climate change, addressing these challenges to improve the environmental sustainability of MRI is imperative. The purpose of this review is to discuss the challenges, opportunities, and the need for action to reduce the environmental impact of MRI and prepare for the effects of climate change. The approaches outlined are categorized as strategies to reduce greenhouse gas (GHG) emissions from MRI during production and use phases, approaches to reduce the environmental impact of MRI including the preservation of finite resources, and development of adaption plans to prepare for the impact of climate change. Co-benefits of these strategies are emphasized including lower GHG emission and reduced cost along with improved heath and patient satisfaction. Although MRI is energy-intensive, there are many steps that can be taken now to improve the environmental sustainability of MRI and prepare for the effects of climate change. On-going research, technical development, and collaboration with industry partners are needed to achieve further reductions in MRI-related GHG emissions and to decrease the reliance on finite resources. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 6.


Asunto(s)
Ambiente , Efecto Invernadero , Humanos
12.
Eur J Radiol ; 170: 111269, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38142572

RESUMEN

OBJECTIVES: Resource planning is a crucial component in hospitals, particularly in radiology departments. Since weather conditions are often described to correlate with emergency room visits, we aimed to forecast the amount of polytrauma-CTs using weather information. DESIGN: All polytrauma-CTs between 01/01/2011 and 12/31/2022 (n = 6638) were retrieved from the radiology information system. Local weather data was downloaded from meteoblue.com. The data was normalized and smoothened. Daily polytrauma-CT occurrence was stratified into below median and above median number of daily polytrauma-CTs. Logistic regression and machine learning algorithms (neural network, random forest classifier, support vector machine, gradient boosting classifier) were employed as prediction models. Data from 2012 to 2020 was used for training, data from 2021 to 2022 for validation. RESULTS: More polytrauma-CTs were acquired in summer compared with winter months, demonstrating a seasonal change (median: 2.35; IQR 1.60-3.22 vs. 2.08; IQR 1.36-3.03; p <.001). Temperature (rs = 0.45), sunshine duration (rs = 0.38) and ultraviolet light amount (rs = 0.37) correlated positively, wind velocity (rs = -0.57) and cloudiness (rs = -0.28) correlated negatively with polytrauma-CT occurrence (all p <.001). The logistic regression model for identification of days with above median number of polytrauma-CTs achieved an accuracy of 87 % on training data from 2011 to 2020. When forecasting the years 2021-2022 an accuracy of 65 % was achieved. A neural network and a support vector machine both achieved a validation accuracy of 72 %, whereas all classifiers regarded wind velocity and ultraviolet light amount as the most important parameters. CONCLUSION: It is possible to forecast above or below median daily number of polytrauma-CTs using weather data. CLINCICAL RELEVANCE STATEMENT: Prediction of polytrauma-CT examination volumes may be used to improve resource planning.


Asunto(s)
Traumatismo Múltiple , Radiología , Humanos , Estudios Retrospectivos , Tiempo (Meteorología) , Tomografía Computarizada por Rayos X , Traumatismo Múltiple/diagnóstico por imagen , Traumatismo Múltiple/epidemiología
13.
Eur Radiol ; 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-37982834

RESUMEN

OBJECTIVES: To automatically label chest radiographs and chest CTs regarding the detection of pulmonary infection in the report text, to calculate the number needed to image (NNI) and to investigate if these labels correlate with regional epidemiological infection data. MATERIALS AND METHODS: All chest imaging reports performed in the emergency room between 01/2012 and 06/2022 were included (64,046 radiographs; 27,705 CTs). Using a regular expression-based text search algorithm, reports were labeled positive/negative for pulmonary infection if described. Data for regional weekly influenza-like illness (ILI) consultations (10/2013-3/2022), COVID-19 cases, and hospitalization (2/2020-6/2022) were matched with report labels based on calendar date. Positive rate for pulmonary infection detection, NNI, and the correlation with influenza/COVID-19 data were calculated. RESULTS: Between 1/2012 and 2/2020, a 10.8-16.8% per year positive rate for detecting pulmonary infections on chest radiographs was found (NNI 6.0-9.3). A clear and significant seasonal change in mean monthly detection counts (102.3 winter; 61.5 summer; p < .001) correlated moderately with regional ILI consultations (weekly data r = 0.45; p < .001). For 2020-2021, monthly pulmonary infection counts detected by chest CT increased to 64-234 (23.0-26.7% per year positive rate, NNI 3.7-4.3) compared with 14-94 (22.4-26.7% positive rate, NNI 3.7-4.4) for 2012-2019. Regional COVID-19 epidemic waves correlated moderately with the positive pulmonary infection CT curve for 2020-2022 (weekly new cases: r = 0.53; hospitalizations: r = 0.65; p < .001). CONCLUSION: Text mining of radiology reports allows to automatically extract diagnoses. It provides a metric to calculate the number needed to image and to track the trend of diagnoses in real time, i.e., seasonality and epidemic course of pulmonary infections. CLINICAL RELEVANCE: Digitally labeling radiology reports represent previously neglected data and may assist in automated disease tracking, in the assessment of physicians' clinical reasoning for ordering radiology examinations and serve as actionable data for hospital workflow optimization. KEY POINTS: • Radiology reports, commonly not machine readable, can be automatically labeled with the contained diagnoses using a regular-expression based text search algorithm. • Chest radiograph reports positive for pulmonary infection moderately correlated with regional influenza-like illness consultations (weekly data; r = 0.45; p < .001) and chest CT reports with the course of the regional COVID-19 pandemic (new cases: r = 0.53; hospitalizations: r = 0.65; p < 0.001). • Rendering radiology reports into data labels provides a metric for automated disease tracking, the assessment of ordering physicians clinical reasoning and can serve as actionable data for workflow optimization.

14.
Eur Urol Focus ; 9(6): 891-893, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37758613

RESUMEN

It is estimated that the health care sector accounts for 4.0-8.5% of total global CO2 emissions, with medical imaging representing an energy-intensive contributor. We outline the carbon footprint of the imaging modalities most relevant to urology and list practical recommendations that can have a positive impact on sustainability. PATIENT SUMMARY: Energy use for medical imaging scans is a significant contributor to carbon emissions by the health care sector. Steps to improve sustainability can include choosing the least energy-intensive option among the scan types suitable for each patient and condition, and switching off equipment when it is not in use.


Asunto(s)
Huella de Carbono , Diagnóstico por Imagen , Humanos
15.
Eur Radiol ; 33(11): 7496-7506, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37542652

RESUMEN

OBJECTIVES: To investigate how a transition from free text to structured reporting affects reporting language with regard to standardization and distinguishability. METHODS: A total of 747,393 radiology reports dictated between January 2011 and June 2020 were retrospectively analyzed. The body and cardiothoracic imaging divisions introduced a reporting concept using standardized language and structured reporting templates in January 2016. Reports were segmented by a natural language processing algorithm and converted into a 20-dimension document vector. For analysis, dimensionality was reduced to a 2D visualization with t-distributed stochastic neighbor embedding and matched with metadata. Linguistic standardization was assessed by comparing distinct report types' vector spreads (e.g., run-off MR angiography) between reporting standards. Changes in report type distinguishability (e.g., CT abdomen/pelvis vs. MR abdomen) were measured by comparing the distance between their centroids. RESULTS: Structured reports showed lower document vector spread (thus higher linguistic similarity) compared with free-text reports overall (21.9 [free-text] vs. 15.9 [structured]; - 27.4%; p < 0.001) and for most report types, e.g., run-off MR angiography (15.2 vs. 1.8; - 88.2%; p < 0.001) or double-rule-out CT (26.8 vs. 10.0; - 62.7%; p < 0.001). No changes were observed for reports continued to be written in free text, e.g., CT head reports (33.2 vs. 33.1; - 0.3%; p = 1). Distances between the report types' centroids increased with structured reporting (thus better linguistic distinguishability) overall (27.3 vs. 54.4; + 99.3 ± 98.4%) and for specific report types, e.g., CT abdomen/pelvis vs. MR abdomen (13.7 vs. 37.2; + 171.5%). CONCLUSION: Structured reporting and the use of factual language yield more homogenous and standardized radiology reports on a linguistic level, tailored to specific reporting scenarios and imaging studies. CLINICAL RELEVANCE: Information transmission to referring physicians, as well as automated report assessment and content extraction in big data analyses, may benefit from standardized reporting, due to consistent report organization and terminology used for pathologies and normal findings. KEY POINTS: • Natural language processing and t-distributed stochastic neighbor embedding can transform radiology reports into numeric vectors, allowing the quantification of their linguistic standardization. • Structured reporting substantially increases reports' linguistic standardization (mean: - 27.4% in vector spread) and distinguishability (mean: + 99.3 ± 98.4% increase in vector distance) compared with free-text reports. • Higher standardization and homogeneity outline potential benefits of structured reporting for information transmission and big data analyses.


Asunto(s)
Procesamiento de Lenguaje Natural , Radiología , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Lingüística
16.
Quant Imaging Med Surg ; 13(7): 4284-4294, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37456296

RESUMEN

Background: Diffuse parenchymal liver diseases are contributing substantially to global morbidity and represent major causes of deaths worldwide. The aim of our study is to assess whether established hepatic fat and iron quantitation and relaxometry-based quantification of hepatocyte-specific contrast material as surrogate for liver function estimation allows to evaluate liver fibrosis. Methods: Retrospective consecutive study. Seventy-two healthy patients (mean age: 53 years) without known liver disease, 21 patients with temporary elevated liver enzymes (mean: 65 years) and 109 patients with biopsy proven liver fibrosis or cirrhosis (mean: 61 years), who underwent liver magnetic resonance imaging (MRI) with a hepatocyte-specific contrast agent [gadoxetate disodium, gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA), 0.25 mmol/mL Primovist, Bayer AG, Leverkusen, Germany] at 1.5 T (n=133) and at 3 T (n=69), were included. Fibrosis was classified using the histopathological meta-analysis of histological data in viral hepatitis (METAVIR) and the clinical Child-Pugh scores. Gd-concentration were quantified using T1 map-based calculations. Gd-concentration mapping was performed by using a Look-Locker approach prior to and 912±159 s after intravenous administration of hepatocyte specific contrast agent. Additionally, parenchymal fat fraction, R2*, bilirubin, gender and age were defined as predicting factors. Diagnostic accuracy was calculated in a monoparametric (linear regression, predictor: Gd-concentration) and multiparametric model (predictors: age, bilirubin level, iron overload, liver fat fraction, Gd concentration in the left and right liver lobe). Results: Mean Gd-concentration in the liver parenchyma was significantly higher for healthy patients ([Gd] =0.51 µmol/L) than for those with liver fibrosis or cirrhosis ([Gd] =0.31 µmol/L; P<0.0001) and with acute liver disease ([Gd] =0.28 µmol/L), though there were no significant differences for the latter two groups. There was a significant moderate negative correlation for the mean Gd-concentration and the METAVIR score (ρ=-0.44, P<0.0001) as well as for the Child-Pugh stage (ρ=-0.35, P<0.0001). There was a significant strong correlation between the bilirubin concentration and the Gd-concentration (ρ=-0.61, P<0.0001). The diagnostic accuracy for the discrimination of healthy patients and patients with known fibrosis or cirrhosis was 0.74 (0.71/0.60 sensitivity/specificity) in a monoparametric and 0.76 (0.85/0.61 sensitivity/specificity) in a machine learning based multiparametric model. Conclusions: T1 mapping-based quantification of hepatic Gd-EOB-DTPA concentrations performed in a multiparametric model shows promising diagnostic accuracy for the detection of fibrotic changes. Liver biopsy might be replaced by imaging examinations.

19.
Eur Radiol Exp ; 7(1): 5, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36750494

RESUMEN

BACKGROUND: To investigate hip implant-related metal artifacts on a 0.55-T system compared with 1.5-T and 3-T systems. METHODS: Total hip arthroplasty made of three different alloys were evaluated in a water phantom at 0.55, 1.5, and 3 T using routine protocols. Visually assessment (VA) was performed by three readers using a Likert scale from 0 (no artifacts) to 6 (extremely severe artifacts). Quantitative assessment (QA) was performed using the coefficient of variation (CoV) and the fraction of voxels within a threshold of the mean signal intensity compared to an automatically defined region of interest (FVwT). Agreement was evaluated using intra/inter-class correlation coefficient (ICC). RESULTS: Interreader agreement of VA was strong-to-moderate (ICC 0.74-0.82). At all field strengths (0.55-T/1.5-T/3-T), artifacts were assigned a lower score for titanium (Ti) alloys (2.44/2.9/2.7) than for stainless steel (Fe-Cr) (4.1/3.9/5.1) and cobalt-chromium (Co-Cr) alloys (4.1/4.1/5.2) (p < 0.001 for both). Artifacts were lower for 0.55-T and 1.5-T than for 3-T systems, for all implants (p ≤ 0.049). A strong VA-to-QA correlation was found (r = 0.81; p < 0.001); CoV was lower for Ti alloys than for Fe-Cr and Co-Cr alloys at all field strengths. The FVwT showed a negative correlation with VA (-0.68 < r < -0.84; p < 0.001). CONCLUSIONS: Artifact intensity was lowest for Ti alloys at 0.55 T. For other alloys, it was similar at 0.55 T and 1.5 T, higher at 3 T. Despite an inferior gradient system and a larger bore width, the 0.55-T system showed the same artifact intensity of the 1.5-T system.


Asunto(s)
Aleaciones , Metales , Titanio , Prótesis e Implantes , Imagen por Resonancia Magnética/métodos
20.
Acad Radiol ; 30(11): 2440-2446, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36841743

RESUMEN

RATIONALE AND OBJECTIVES: To assess the potential of 0.55T low-field MRI system in lumbar spine imaging with and without the use of additional advanced postprocessing techniques. MATERIALS AND METHODS: The lumbar spine of 14 volunteers (32.9 ± 3.6 years) was imaged both at 0.55T and 1.5T using sequences from clinical routine. On the 0.55T scanner system, additional sequences with simultaneous multi-slice acquisition and artificial intelligence-based postprocessing techniques were acquired. Image quality of all 28 examinations was assessed by three musculoskeletal radiologists with respect to signal/contrast, resolution, and assessability of the spinal canal and neuroforamina using a 5-point Likert scale (1 = non-diagnostic to 5 = perfect quality). Interrater agreement was evaluated with the Intraclass Correlation Coefficient and the Mann-Whitney U test (significance level: p < 0.05). RESULTS: Image quality at 0.55T was rated lower on the 5-point Likert scale compared to 1.5T regarding signal/contrast (mean: 4.16 ± 0.29 vs. 4.54 ± 0.29; p < 0.001), resolution (4.07 ± 0.31 vs. 4.49 ± 0.30; p < 0.001), assessability of the spinal canal (4.28 ± 0.13 vs. 4.73 ± 0.26; p < 0.001) and the neuroforamina (4.14 ± 0.28 vs. 4.70 ± 0.27; p < 0.001). Image quality for the AI-processed sagittal T1 TSE and T2 TSE at 0.55T was also rated slightly lower, but still good to perfect with a concomitant reduction in measurement time. Interrater agreement was good to excellent (range: 0.60-0.91). CONCLUSION: While lumbar spine image quality at 0.55T is perceived inferior to imaging at 1.5T by musculoskeletal radiologists, good overall examination quality was observed with high interrater agreement. Advanced postprocessing techniques may accelerate intrinsically longer acquisition times at 0.55T.