Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rapid Commun Mass Spectrom ; 30(15): 1787-96, 2016 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-27426455

RESUMEN

RATIONALE: It is well known that the organic anion transporting polypeptide 1B1 (OATP1B1) plays a major role in the hepatic uptake of a range of drugs. To this end, it is pivotal that the potential for new molecular entities (NMEs) to inhibit OATP1B1 activity be assessed during early drug discovery. The work reported herein describes the development of a high-throughput analytical method to measure the clinically relevant probe substrate, pitavastatin, for the in vitro assessment of OATP1B1 inhibition. METHODS: Development of an analytical method capable of very fast throughput was crucial for the success of this assay and was accomplished using a system which combines direct, on-line solid-phase extraction (SPE) with highly sensitive, label-free tandem mass spectrometry (MS/MS)-based detection. Mass spectrometry analysis of pitavastatin, along with the stable isotopically labeled internal standard d5-pitavastatin, was conducted using positive electrospray ionization (ESI) in selected reaction monitoring (SRM) mode. RESULTS: The on-line SPE-MS/MS platform demonstrated similar sensitivity, selectivity, reproducibility, linearity and robustness to existing methodologies while achieving analytical cycle times of 10.4 seconds per well. Sensitivity exceeded what was necessary for our assay conditions, with a determined lower limit of quantification (LLOQ) for pitavastatin of 10 pM (picomolar) in assay matrix. Furthermore, the potency of multiple reference compounds was shown to be within 2-fold of IC50 values generated from liquid chromatography (LC)/MS/MS-based literature values. CONCLUSIONS: A very fast and robust analytical method was successfully developed for the measurement of the clinically relevant OATP1B1 substrate, pitavastatin. The successful development and implementation of this very important early liability screen has helped to facilitate judicious lead candidate progression and will ultimately help build a greater understanding of OATP1B1-NME interactions, in general. Copyright © 2016 John Wiley & Sons, Ltd.


Asunto(s)
Cromatografía Liquida , Descubrimiento de Drogas , Transportador 1 de Anión Orgánico Específico del Hígado/efectos de los fármacos , Espectrometría de Masas en Tándem , Humanos , Reproducibilidad de los Resultados , Extracción en Fase Sólida
2.
Rapid Commun Mass Spectrom ; 25(9): 1231-40, 2011 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-21488121

RESUMEN

The evaluation of interactions between drug candidates and transporters such as P-glycoprotein (P-gp) has gained considerable interest in drug discovery and development. Inhibition of P-gp can be assessed by performing bi-directional permeability studies with in vitro P-gp-expressing cellular model systems such as Caco-2 (human colon carcinoma) cells, using digoxin as a substrate probe. Existing methodologies include either assaying (3)H-digoxin with liquid scintillation counting (LSC) detection or assaying non-labeled digoxin with liquid chromatography-tandem mass spectrometric (LC-MS/MS) analysis at a speed of several minutes per sample. However, it is not feasible to achieve a throughput high enough using these approaches to sustain an early liability screen that generates more than a thousand samples on a daily basis. To address this challenge, we developed an ultrafast (9 s per sample) bioanalytical method for digoxin analysis using RapidFire™, an on-line solid-phase extraction (SPE) system, with MS/MS detection. A stable isotope labeled analog, d3-digoxin, was used as internal standard to minimize potential ionization matrix effect during the RF-MS/MS analysis. The RF-MS/MS method was more than 16 times faster than the LC-MS/MS method but demonstrated similar sensitivity, selectivity, reproducibility, linearity and robustness. P-gp inhibition results of multiple validation compounds obtained with this RF-MS/MS method were in agreement with those generated by both the LC-MS/MS method and the (3)H-radiolabel assay. This method has been successfully deployed to assess P-gp inhibition potential as an important early liability screen for drug-transporter interaction.


Asunto(s)
Miembro 1 de la Subfamilia B de Casetes de Unión a ATP/antagonistas & inhibidores , Cromatografía Liquida/métodos , Digoxina/análisis , Ensayos Analíticos de Alto Rendimiento/métodos , Espectrometría de Masas en Tándem/métodos , Miembro 1 de la Subfamilia B de Casetes de Unión a ATP/metabolismo , Células CACO-2 , Ciclosporina/química , Ciclosporina/farmacología , Digoxina/química , Digoxina/metabolismo , Descubrimiento de Drogas/métodos , Descubrimiento de Drogas/normas , Humanos , Modelos Lineales , Modelos Biológicos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Extracción en Fase Sólida , Tritio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA