1.
Appl Radiat Isot ; 67(2): 334-9, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19081263

RESUMEN

The RS 2400's cylindrical X-ray source yields dose rates high enough to allow the irradiator to replace widely used gamma irradiators. Except for the leftmost 5 cm, beam uniformity is within 10% at the tube surface. At maximum operating parameters, the beam has HVL(1)=13.66 mm aluminum, HC=0.47, and hv(eq)=88.5 keV. Maximum dose rates to tissue are 65 Gy min(-1)+/-3.1% at tube surface, 37 Gy min(-1)+/-3.1% at center of canisters, 14.1 Gy min(-1)+/-6.5% for thin-shelled oysters, and 12.3 Gy min(-1)+/-6.2% for thick-shelled oysters.


Asunto(s)
Irradiación de Alimentos , Ostreidae/efectos de la radiación , Esterilización/métodos , Animales , Irradiación de Alimentos/métodos , Irradiación de Alimentos/normas , Dosis de Radiación , Rayos X