1.
J Clin Virol ; 154: 105222, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35797940

RESUMEN

BACKGROUND: Antigen testing has become an essential part of fighting the ongoing COVID-19 pandemic. With the continual increase in available tests, independent and extensive comparative evaluations using data from external quality assessment (EQA) studies to evaluate test performance between different users are required. OBJECTIVES: An EQA scheme was established to assess the sensitivity of antigen tests and the potential impact of circulating SARS-CoV-2 strains on their performance. STUDY DESIGN: Panels were prepared for three challenges in 2021 containing inactivated SARS-CoV-2-positive samples of various genetic strains (including variants of concern, VOCs) at different concentrations, and negative samples. Data was analysed based on qualitative testing results in relation to the antigen test used. RESULTS: Participants registered for each individual challenge in any combination. In total, 258 respondents from 27 countries worldwide were counted submitting 472 datasets. All core samples were correctly reported by 76.7 to 83.1% at participant level and by 73.5 to 83.8% at dataset level. Sensitivity differences could be shown in viral loads and SARS-CoV-2 strains/variants including the impact on performance by a B.1.1.7-like mutant strain with a deletion in the nucleoprotein gene. Lateral flow rapid antigen tests showed a higher rate of false negatives in general compared with automated point-of-care tests and laboratory ELISA/immunoassays. CONCLUSIONS: EQA schemes can provide valuable data to inform participants about weaknesses in their testing process or methods and support ongoing assay evaluations for regulatory approval or post-market surveillance.


Asunto(s)
COVID-19 , COVID-19/diagnóstico , Humanos , Pandemias , SARS-CoV-2/genética , Sensibilidad y Especificidad
2.
Euro Surveill ; 25(27)2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32672149

RESUMEN

Laboratory preparedness with quality-assured diagnostic assays is essential for controlling the current coronavirus disease (COVID-19) outbreak. We conducted an external quality assessment study with inactivated severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) samples to support clinical laboratories with a proficiency testing option for molecular assays. To analyse SARS-CoV-2 testing performance, we used an online questionnaire developed for the European Union project RECOVER to assess molecular testing capacities in clinical diagnostic laboratories.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Técnicas de Laboratorio Clínico/normas , Infecciones por Coronavirus/diagnóstico , Coronavirus/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Pandemias , Neumonía Viral/diagnóstico , Betacoronavirus , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Servicios de Laboratorio Clínico , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Brotes de Enfermedades , Europa (Continente) , Humanos , Pandemias/prevención & control , Neumonía Viral/epidemiología , Neumonía Viral/virología , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/normas , SARS-CoV-2 , Sensibilidad y Especificidad , Encuestas y Cuestionarios
3.
Viruses ; 10(9)2018 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-30216988

RESUMEN

Quality Control for Molecular Diagnostics (QCMD), an international provider for External Quality Assessment (EQA) programmes, has introduced a programme for molecular diagnostics of Zika virus (ZIKV) in 2016, which has been continuously offered to interested laboratories since that time. The EQA schemes provided from 2016 to 2018 revealed that 86.7% (92/106), 82.4% (89/108), and 88.2% (90/102) of the participating laboratories reported correct results for all samples, respectively in 2016, 2017, and 2018. The review of results indicated a need for improvement concerning analytical sensitivity and specificity of the test methods. Comparison with the outcomes of other EQA initiatives briefly summarized here show that continuous quality assurance is important to improve laboratory performance and to increase preparedness with reliable diagnostic assays for effective patient management, infection and outbreak control.


Asunto(s)
Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Infección por el Virus Zika/diagnóstico , Infección por el Virus Zika/virología , Virus Zika/genética , Brotes de Enfermedades , Historia del Siglo XXI , Humanos , Garantía de la Calidad de Atención de Salud , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Infección por el Virus Zika/historia , Infección por el Virus Zika/prevención & control
4.
Methods Mol Biol ; 943: 49-79, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23104281

RESUMEN

In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Técnicas Microbiológicas/normas , Técnicas de Diagnóstico Molecular/normas , Humanos , Ensayos de Aptitud de Laboratorios/normas , Personal de Laboratorio Clínico/educación , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA