Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 57
1.
Toxicology ; 505: 153837, 2024 May 17.
Article En | MEDLINE | ID: mdl-38763426

Tetrabromobisphenol A (TBBPA) has become a topic of public attention due to its pervasive detection in the environment and organisms in recent decades. However, limited information is available regarding the toxicity of TBBPA on reproductive ability of male mammals. Herein, the reproductive toxicity of TBBPA was investigated in male rats to fill the knowledge gap. In this study, male rats were exposed to TBBPA (0, 10, 100, and 1000 mg/kg) for 6 weeks. Subsequently, body and organ indexes, histopathological evaluation of testis and epididymis, ultrastructural observation of sperm, testosterone and progesterone levels, and oxidative stress indicators were conducted to reveal corresponding mechanisms. Results obtained showed that compare to the control group, the body weight, testes weight, epididymis weight, seminal vesicle and coagulation glands weight of rats in the 1000 mg/kg group lost 8.30%, 16.84%, 20.16%, 19.72% and 26.42%, respectively. Intriguingly, exposure to TBBPA (10, 100, 100 mg/kg) resulted in substantial pathological damage in testis, epididymis and sperm. TBBPA exposure also increased malondialdehyde (MDA) and hydrogen peroxide (H2O2) contents, as well as superoxide dismutase (T-SOD) and catalase (CAT) activities in testicular tissue. What's more, the testosterone and progesterone levels in male rat serum were significantly decreased after exposure to TBBPA for 6 weeks. Meanwhile, results of molecular docking showed that TBBPA has a strong affinity with estrogen receptors (ERs). These findings demonstrated that TBBPA exposure negatively impacts the reproductive ability of male rats, thus providing new insights for risk assessment for reproductive health under TBBPA exposure.

2.
Europace ; 2024 May 27.
Article En | MEDLINE | ID: mdl-38801673

AIM: Radiofrequency ablation (RFA) is used as a first-line therapy for accessory pathways (APs). However, data regarding the effects of pulsed field ablation (PFA) on APs are limited. We sought to evaluate the acute procedural and 6-month success and safety of PFA in a cohort of patients with APs. METHODS AND RESULTS: A focal contact-force sensing PFA catheter was used for patients with APs. PFA generator generated a bipolar and biphasic waveform (± 1000 V) with a duration of 100 ms from the tip of PFA catheter. 100% acute procedural success was achieved in 10 conscious patients with APs (7 left anterolateral, 2 left inferolateral, and 1 right posteroseptal APs) including 6 (60%) patients after an initial application. The average total ablation time was 6.3 ± 4.9 seconds for 4.7 ± 1.8 ablation sites (ASs), including 3.1 ± 2.4 seconds at targets and 3.2 ± 2.9 seconds at 3.2 ± 2 bolus ASs. The mean skin-to-skin time was 59.3 ± 15.5 minutes, and PFA catheter dwell time was 29.4 ± 7.8 minutes. One patient encountered transient sinus arrest during PFA due to parasympathetic overexcitation. Sinus rhythm was restored in all patients without any significant adverse events during short-term follow-up. CONCLUSIONS: PFA of APs was feasible, effective, and safe. Its efficiency was remarkable for its ultrarapid termination of AP conduction. Further studies are warranted to prove whether utilization of PFA with current parameters can extend to manifold APs ablation.

3.
Heliyon ; 10(8): e28801, 2024 Apr 30.
Article En | MEDLINE | ID: mdl-38638993

Objective: To investigate the association between air pollutants and the incidence of tuberculosis (TB) through a systematic review and meta-analysis, and to provide directions for future research and prevention of TB. Methods: A search was conducted for all literature related to the incidence of TB and air pollution in the database. We screened the retrieved articles and proceeded statistical analyses using random effects models to investigate the relationships between five air pollutants (PM2.5, PM10, SO2, NO2 and O3) and the incidence of TB. Results: The initial search identified 100 pieces of literature and 9 studies met the screening criteria after the screening. The single-day lagged risk ratio (RR) and 95% Confidence Intervals (CIs) for the combined effects estimates are as follows: PM2.5: 1.059 (0.966, 1.160); PM10: 1.000 (0.996, 1.004); SO2: 0.980 (0.954, 1.007); NO2: 1.011 (0.994, 1.027); O3: 0.994 (0.980,1.008). The cumulative lagged results for these five pollutants are listed like this: PM2.5: 1.095 (0.983, 1.219); PM10: 1.035 (1.006, 1.066); SO2: 0.964 (0.830, 1.121); NO2: 1.037 (1.010, 1.065); O3: 0.982 (0.954, 1.010). Conclusion: The single-day lag effects of PM2.5, PM10, SO2, NO2, and O3 are not statistically significantly relevant for the occurrence of TB. However, the cumulative lag results show that both PM10 and NO2 contribute to the prevalence of TB, while the statistical relationship between the cumulative lag effects of PM2.5, SO2, and O3 and the onset of TB remains unknown.

4.
Water Res ; 253: 121253, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38350193

Human activities have long impacted the health of Earth's rivers and lakes. These inland waters, crucial for our survival and productivity, have suffered from contamination which allows the formation and spread of antibiotic-resistant genes (ARGs) and consequently, ARG-carrying pathogens (APs). Yet, our global understanding of waterborne pathogen antibiotic resistance remains in its infancy. To shed light on this, our study examined 1240 metagenomic samples from both open and closed inland waters. We identified 22 types of ARGs, 19 types of mobile genetic elements (MGEs), and 14 types of virulence factors (VFs). Our findings showed that open waters have a higher average abundance and richness of ARGs, MGEs, and VFs, with more robust co-occurrence network compared to closed waters. Out of the samples studied, 321 APs were detected, representing a 43 % detection rate. Of these, the resistance gene 'bacA' was the most predominant. Notably, AP hotspots were identified in regions including East Asia, India, Western Europe, the eastern United States, and Brazil. Our research underscores how human activities profoundly influence the diversity and spread of resistome. It also emphasizes that both abiotic and biotic factors play pivotal roles in the emergence of ARG-carrying pathogens.


Anti-Bacterial Agents , Genes, Bacterial , Humans , Drug Resistance, Microbial/genetics , Anti-Bacterial Agents/pharmacology , Metagenomics , Metagenome
5.
Environ Res ; 249: 118337, 2024 May 15.
Article En | MEDLINE | ID: mdl-38325783

Microorganisms are integral to freshwater ecological functions and, reciprocally, their activity and diversity are shaped by the ecosystem state. Yet, the diversity of bacterial community and its driving factors at a large scale remain elusive. To bridge this knowledge gap, we delved into an analysis of 16S RNA gene sequences extracted from 929 water samples across China. Our analyses revealed that inland water bacterial communities showed a weak latitudinal diversity gradient. We found 530 bacterial genera with high relative abundance of hgcI clade. Among them, 29 core bacterial genera were identified, that is strongly linked to mean annual temperature and nutrient loadings. We also detected a non-linear response of bacterial network complexity to the increasing of human pressure. Mantel analysis suggested that MAT, HPI and P loading were the major factors driving bacterial communities in inland waters. The map of taxa abundance showed that the abundant CL500-29 marine group in eastern and southern China indicated high eutrophication risk. Our findings enhance our understanding of the diversity and large-scale biogeographic pattern of bacterial communities of inland waters and have important implications for microbial ecology.


Bacteria , RNA, Ribosomal, 16S , China , Bacteria/genetics , Bacteria/classification , Bacteria/isolation & purification , RNA, Ribosomal, 16S/analysis , RNA, Ribosomal, 16S/genetics , Biodiversity , Water Microbiology , Fresh Water/microbiology
6.
Heart Rhythm ; 2024 Jan 23.
Article En | MEDLINE | ID: mdl-38272283

BACKGROUND: Data regarding left atrial appendage closure (LAAC) in patients with left atrial appendage (LAA) thrombus are limited. Recently published cases have mostly been guided by transesophageal echocardiography. Intracardiac echocardiography (ICE) is now widely used during LAAC procedures. OBJECTIVE: This is the first study to report the feasibility of LAAC in patients with LAA thrombus guided by ICE. METHODS: Patients with persistent LAA thrombus despite anticoagulation or contraindications to anticoagulation who underwent a modified ICE-guided LAAC procedure between June 2021 and April 2023 were included. Periprocedural events and clinical outcomes during follow-up were recorded. RESULTS: A total of 12 patients (mean age 65 ± 7 years; 92% male) were included: 10 with persistent LAA thrombus and 2 with contraindications to anticoagulation. Most of the thrombus was at the apex (n = 6), followed by the body (n = 3) and the ostium (n = 3). A LAmbre device was used and successfully implanted in all patients with the guidance of ICE. No thrombotic material was retrieved from patients with the protection of cerebral protection device (n = 11). No patient experienced severe periprocedural complications. All patients completed transesophageal echocardiography follow-up, and no device-related thrombus or peridevice leak > 3 mm was detected. None of the patients experienced stroke/transient ischemic attack, systemic embolism, or major bleeding events during a median follow-up of 147 days (interquartile range 80-306 days). CONCLUSION: LAAC using the LAmbre device guided by ICE may be feasible in patients with LAA thrombus when performed by experienced operators.

7.
J Formos Med Assoc ; 123(5): 600-605, 2024 May.
Article En | MEDLINE | ID: mdl-38238125

BACKGROUND: The diameter and shape of the left atrial appendage (LAA) orifices may influence occluder selection and the outcomes of left atrial appendage closure (LAAC) procedure. This study aimed to evaluate the impact of LAA orifice diameter on the safety and efficacy of LAAC using the LAmbre device. METHODS: A total of 133 patients with nonvalvular atrial fibrillation (AF) who underwent LAAC with the LAmbre device between June 2018 and June 2020 were included in this study. The patients were categorized into two groups based on the maximal diameter of the LAA orifice: the large LAA group (n = 45) with a maximal orifice diameter of ≥31 mm, and the normal LAA group (n = 88) with a maximal orifice diameter of <31 mm. The study assessed periprocedural characteristics and long-term clinical follow-up. RESULTS: Successful implantation of the LAmbre device was observed in all patients. The incidence of periprocedural peridevice leakage (PDL) was significantly higher in the large LAA group (P < 0.001), while the incidence of acute pericardial effusion (PE) during the procedure was comparable between the two groups (P = 1.000). After a mean follow-up period of 4.8 ± 1.7 years, three patients in the large LAA group developed delayed PE, while no patients in the normal LAA group did (P = 0.037). Additionally, a larger LAA maximal orifice diameter was associated with a higher prevalence of PDL (P = 0.001) and PE (including both acute and delayed PE) (P = 0.027). The optimal cutoff value of the LAA maximal orifice diameter for predicting PDL and PE after LAAC with the LAmbre device was determined to be 30 mm. CONCLUSION: The findings suggest that the LAmbre device is a safe and feasible option for occluding the LAA, regardless of its orifice diameter. However, it is important to note that a larger LAA orifice diameter may increase the risk of PDL and delayed PE.


Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Female , Male , Aged , Middle Aged , Septal Occluder Device/adverse effects , Retrospective Studies , Treatment Outcome , Aged, 80 and over , Echocardiography, Transesophageal , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Left Atrial Appendage Closure
8.
Can J Cardiol ; 2024 Jan 17.
Article En | MEDLINE | ID: mdl-38242530

BACKGROUND: Pulsed field ablation (PFA) is primarily used for treatment of atrial fibrillation as it provides better safety and efficacy. However, there are limited data available on the use of PFA for paroxysmal supraventricular tachycardia (PSVT). The study sought to describe the outcomes of PSVT ablation with a novel focal contact force (CF)-sensing PFA. METHODS: In this first-in-human pilot study, a focal CF-sensing PFA catheter was used for mapping and ablation navigated with an electroanatomic mapping system (EAMS). Pulsed field energy was delivered as biphasic/bipolar electrical pulse trains with 2000 V/delivery. CF was controlled from 2 g to 10 g during PFA. RESULTS: Procedural acute success was achieved without general anaesthesia or conscious sedation in all 10 patients, including 7 patients diagnosed with typical atrioventricular nodal re-entrant tachycardias and 3 patients with orthodromic reciprocating tachycardias. Successful target ablation time was 2.0 ± 0.5 seconds per patient, and the acute procedural success at the first single site was achieved in 5 patients. The mean skin-to-skin procedure time was 79.4 ± 15 minutes, PFA catheter dwell time was 50.1 ± 14 minutes, and fluoroscopy time was 6.2 ± 7 minutes. Maintenance of sinus rhythm was observed in all patients within 6-month follow-up. No serious adverse events occurred in any subjects during PFA or during the 6-month follow-up. CONCLUSIONS: A focal CF-sensing PFA catheter could effectively, rapidly, and safely ablate PSVT in conscious patients. CLINICAL TRIAL REGISTRATION: NCT05770921.

9.
Clin Cardiol ; 47(1): e24169, 2024 Jan.
Article En | MEDLINE | ID: mdl-37804320

BACKGROUND: Catheter ablation (CA) combined with left atrial appendage closure (LAAC) has emerged as a promising method to relieve symptoms while reducing the incidence of stroke in selected high-risk patients with atrial fibrillation (AF). HYPOTHESIS: We aimed to investigate the clinical outcomes of combined CA and LAAC in elderly patients. METHODS: A total of 316 patients with symptomatic drug-refractory AF who underwent combined CA and LAAC between January 2016 and December 2020 were retrospectively included. Baseline characteristics, periprocedural complications, and clinical events during follow-up were recorded and compared between patients aged ≥ 75 years (n = 66) and <75 years (n = 250). RESULTS: Pulmonary vein isolation and satisfactory LAAC were achieved in all patients. No patients experienced death or stroke/transient ischemic stroke periprocedurally. After a median follow-up of 12.2 (6.7-24.4) months and 11.9 (5.5-23.6) months, the rate of sinus rhythm maintenance was comparable between the two groups (≥75 years: 78.8% vs. <75 years: 80.8%; log-rank test, p = 0.674). The median follow-up periods for clinical outcomes were 27.9 (9.3-44.8) months and 25.2 (10.8-45.7) months, respectively. In patients aged ≥ 75 years, one suffered ischemic stroke, and one experienced major bleeding event. In patients aged < 75 years, four had ischemic stroke, and eight had major bleeding events. Two patients aged < 75 years died during follow-up, while none of the patients aged ≥ 75 years died. CONCLUSIONS: Combining CA and LAAC was feasible, safe and effective in elderly patients with AF.


Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Ischemic Stroke , Septal Occluder Device , Stroke , Aged , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Retrospective Studies , Left Atrial Appendage Closure , Treatment Outcome , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Septal Occluder Device/adverse effects , Stroke/etiology , Stroke/prevention & control , Hemorrhage/etiology , Ischemic Stroke/etiology , Ischemic Stroke/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods
10.
ACS Nano ; 18(1): 798-808, 2024 Jan 09.
Article En | MEDLINE | ID: mdl-38149592

Electrochemical capacitors have faced the limitations of low energy density for decades, owing to the low capacity of electric double-layer capacitance (EDLC)-type positive electrodes. In this work, we reveal the functions of interlayer confined water in iron vanadate (FeV3O8.7·nH2O) for sodium-ion storage in nonaqueous electrolyte. Using an electrochemical quartz crystal microbalance, in situ Raman, and ex situ X-ray diffraction and X-ray photoelectron spectroscopy, we demonstrate that both nonfaradaic (surficial EDLC) and faradaic (pseudocapacitance-dominated Na+ intercalation) processes are involved in the charge storages. The interlayer confined water is able to accelerate the fast Na+ intercalations and is highly stable (without the removal of water or co-intercalation of [Na-diglyme]+) in the nonaqueous environment. Furthermore, coupling the pseudocapacitive FeV3O8.7·nH2O with EDLC-type activated carbon (FeVO-AC) as the positive electrode brings comprehensive enhancements, displaying the enlarged compaction density of ∼2 times, specific capacity of ∼1.5 times, and volumetric capacity of ∼3 times compared to the AC electrode. Furthermore, the as-assembled hybrid sodium-ion capacitor, consisting of an FeVO-AC positive electrode and a mesocarbon microbeads negative electrode, shows a high energy density of 108 Wh kg-1 at 108 W kg-1 and 15.3 Wh kg-1 at 8.3 kW kg-1. Our results offer an emerging route for improving both specific and volumetric energy densities of electrochemical capacitors.

11.
Front Cardiovasc Med ; 10: 1223064, 2023.
Article En | MEDLINE | ID: mdl-37649670

Background: Marshall vein ethanol infusion (MVEI) as an additional therapy to conventional catheter ablation (CA) has been proved to be efficacious in patients with persistent atrial fibrillation (PeAF). However, whether empirical MVEI could be the first-line strategy in mitral isthmus (MI) ablation has seldom been investigated. Here, we aim to compare the efficacy, safety, and long-term outcomes between provisional and empirical MVEI in PeAF patients undergoing the index MI ablation procedure. Methods: We enrolled 133 patients with PeAF either in the provisional group (n = 38, MVEI was performed when conventional endocardial and/or epicardial ablation procedures were inadequate to achieve bidirectional MI block) or in the empirical group (n = 95, MVEI was performed empirically before MI CA). Results: All of the baseline characteristics were comparable. Less spontaneous or inducible atrial tachycardias (ATs) were encountered in the empirical group of patients (P < 0.001). More epicardial ablations were applied (26.3% vs. 9.5%, P = 0.016) and a higher incidence of CA-facilitated restoration of sinus rhythm was recorded (86.8% vs. 11.7%, P < 0.001) in the provisional group of patients. Although more fluoroscopy time (6.4[4.2, 9.3] vs. 9.5[5.9, 11.6] min, P = 0.019) and radiation exposure (69.0[25.3, 160.2] vs. 122.0[62.5, 234.1] mGy, P = 0.010) were documented in the empirical group with comparable procedure time, less time (455.9 ± 192.2 vs. 366.5 ± 161.3 s, P = 0.038) was consumed to achieve bidirectional MI block during endocardial ablation in the provisional group. Incidences of procedure-related complications were similar between the two groups. During a 16.5 ± 4.4-month follow-up, the empirical group of patients showed a significantly higher rate of freedom from AT recurrence (95.8% vs. 81.6%, log-rank P = 0.003), while the rate of freedom from AF or atrial tachyarrhythmias (combining AF and AT) was similar. Both univariate (HR 0.19, 95% CI 0.05-0.64, P = 0.008) and multivariate (HR 0.25, 95% CI 0.07-0.92, P = 0.037) Cox regression analyses indicated that empirical MVEI was independently associated with lower long-term AT recurrence. Conclusion: Among patients with PeAF who underwent the index MI ablation procedure, empirical MVEI could reduce endocardial MI ablation time and provide greater long-term freedom from AT recurrence.

12.
Int Heart J ; 64(4): 632-640, 2023.
Article En | MEDLINE | ID: mdl-37518344

Atrial fibrillation (AF) is the most common arrhythmia that is harmful to human health. This study aims to explore the relationship between myosin light chain 4 (MYL4) and AF recurrence after radiofrequency ablation (RFA). Patients with AF (n = 85) were enrolled, and healthy subjects (n = 90) with normal sinus rhythm and no previous history of AF were selected as controls. The serum levels of MYL4, transforming growth factor (TGF) -ß1, and procollagen type-I C-terminal propeptide (PICP) were determined. The correlation between MYL4 and atrial fibrosis remodeling indicators (TGF-ß1/PICP) and left atrial diameter (LAD) was analyzed. The influence of MYL4 on AF recurrence after RFA was evaluated, and the independent correlation between them was assessed. Patients with AF and the controls showed no significant differences in age, gender, body mass index, systolic blood pressure, diastolic blood pressure, left ventricular ejection fraction, triglycerides, total cholesterol, high-density lipoprotein, low-density lipoprotein, white blood cell count, neutrophil/lymphocyte ratio, brain natriuretic peptide, and history of smoking, drinking, hypertension, and diabetes (P > 0.05), but with increased LAD in patients with AF (P < 0.01). Serum MYL4 level was reduced in patients with AF (0.6 ± 0.2) compared with that of controls (0.1 ± 0.6) (P < 0.01), and it was negatively correlated with TGF-ß1, PICP, and LAD (r = -0.2389, P < 0.05; r = -0.5174, P < 0.01; r = -0.3191; P < 0.01). Low levels of MYL4 increased the risk of AF recurrence after RFA (χ2 = 16.64; P < 0.0001). A low MYL4 level in patients with AF showed a poorer prognosis. Serum MYL4 level and AF type were independent risk factors affecting AF recurrence after RFA.


Atrial Fibrillation , Catheter Ablation , Radiofrequency Ablation , Humans , Myosin Light Chains , Recurrence , Stroke Volume , Transforming Growth Factor beta1 , Treatment Outcome , Ventricular Function, Left
13.
Adv Sci (Weinh) ; 10(26): e2301980, 2023 09.
Article En | MEDLINE | ID: mdl-37424042

Antibiotic overuse and the subsequent environmental contamination of residual antibiotics poses a public health crisis via an acceleration in the spread of antibiotic resistance genes (ARGs) through horizontal gene transfer. Although the occurrence, distribution, and driving factors of ARGs in soils have been widely investigated, little is known about the antibiotic resistance of soilborne pathogens at a global scale. To explore this gap, contigs from 1643 globally sourced metagnomes are assembled, yielding 407 ARG-carrying pathogens (APs) with at least one ARG; APs are detected in 1443 samples (sample detection rate of 87.8%). The richness of APs is greater in agricultural soils (with a median of 20) than in non-agricultural ecosystems. Agricultural soils possess a high prevalence of clinical APs affiliated with Escherichia, Enterobacter, Streptococcus, and Enterococcus. The APs detected in agricultural soils tend to coexist with multidrug resistance genes and bacA. A global map of soil AP richness is generated, where anthropogenic and climatic factors explained AP hot spots in East Asia, South Asia, and the eastern United States. The results herein advance this understanding of the global distribution of soil APs and determine regions prioritized to control soilborne APs worldwide.


Metagenomics , Soil , Ecosystem , Soil Microbiology , Anti-Bacterial Agents
15.
Front Cardiovasc Med ; 10: 1188322, 2023.
Article En | MEDLINE | ID: mdl-37346285

Background: Pericardial effusion (PE) is an uncommon but serious complication that occurs following percutaneous left atrial appendage closure (LAAC). There are few data regarding PE following implantation of the LAmbre device for LAAC. Methods: Patients with nonvalvular atrial fibrillation (AF) undergoing percutaneous LAAC using the LAmbre device at the Arrhythmia Center of Ningbo First Hospital from October 2017 to March 2021 were retrospectively reviewed (n = 133). PE was defined as acute if diagnosed ≤7 days post LAAC (n = 3, 2.3%) or delayed if diagnosed >7 days post LAAC (n = 3, 2.3%). The clinical characteristics and procedural data were compared between patients with PE (PE group, n = 6) and without PE (non-PE group, n = 127). The predictors of PE were analyzed by logistic regression. Results: All patients with PE recovered following treatment by pericardiocentesis. Patients with PE were found to have a higher incidence of congestive heart failure (50.0% vs. 13.4%, P = 0.044) and had larger measured LAA orifice diameters (33.5 mm ± 6.0 mm vs. 28.3 mm ± 5.2 mm, P = 0.018) and landing zone diameters (27.8 mm ± 4.8 mm vs. 23.9 mm ± 4.8 mm, P = 0.054) compared with those without PE. The diameters of the device umbrellas (31.7 mm ± 5.6 mm vs. 26.9 mm ± 5.0 mm, P = 0.026) and covers (36.3 mm ± 4.6 mm vs. 33.4 mm ± 4.0 mm, P = 0.075) implanted were larger in the PE group compared to the non-PE group. Univariate logistic regression revealed that congestive heart failure (OR = 6.47, 95% CI = 1.21-34.71, P = 0.029) and LAA maximal orifice diameter (OR = 1.22, 95% CI = 1.02-1.45, P = 0.027) were both associated with PE following LAmbre device implantation. Conclusions: In this single-center experience, both acute and delayed PE were uncommon in patients with AF following LAmbre device implantation. Congestive heart failure and a larger LAA orifice were identified as predictors for the occurrence of PE.

16.
Article En | MEDLINE | ID: mdl-36892868

The optimal carrier concentration of thermoelectric materials increases with increasing temperature. However, conventional aliovalent doping usually provides an approximately constant carrier concentration over the whole temperature range, which can only match the optimal carrier concentration in a narrow temperature range. In this work, n-type indium and aluminum codoped PbTe were prepared with high-pressure synthesis, followed by spark plasma sintering. While Al doping can provide a roughly constant carrier concentration with varying temperatures, In doping can trap electrons at low temperatures and release them at high temperatures, thus optimizing the carrier concentration over a broad temperature range. As a result, both electrical transport properties and thermal conductivity are optimized, and a significantly enhanced thermoelectric performance is achieved in InxAl0.02Pb0.98Te. The optimal In0.008Al0.02Pb0.98Te shows a peak ZT of 1.3 and an average ZT of 1, with a decent conversion efficiency of 14%. Current work demonstrates that optimizing carrier concentration with varying temperatures is effective to enhance the thermoelectric performance of n-type PbTe.

17.
Environ Pollut ; 316(Pt 1): 120690, 2023 Jan 01.
Article En | MEDLINE | ID: mdl-36403871

Freshwater microorganisms and their interactions are important drivers of nutrient cycling that are in turn affected by nutrient status, causing shifts in microbial community diversity, composition, and interactions. However, the impact of water trophic status on bacterial-archaeal interdomain interactions remains poorly understood. This study focused on the impact of trophic status, as characterized by trophic state index (TSI), on the interdomain interactions of freshwater microbial communities from 45 ponds in Hangzhou. Our results showed that the mesotrophic wetland bordering on lightly eutrophic (Hemu: TSI of 49; lightly eutrophic is defined as 50 ≤ TSI <60) harbored a much more complex bacterial-archaeal interdomain network, which showed significantly (P < 0.05) higher connectivity than the wetlands with lower (TSI of 38) or higher (TSI of 57) trophic levels. Notably, light eutrophication strengthened the network modules' negative associations with organic carbon through some network hubs, which could trigger carbon loss in wetlands. We also detected a non-linear response of interdomain network complexity to the increasing of nutrients with a turning point of approximately TSI 50. Quantitative estimates of community assembly processes and structural equation modelling analysis indicated that chlorophyll-a, total nitrogen, and total phosphorus could regulate interdomain network complexity (50% of the variation explanation rate) by driving microbial community assembly. This study demonstrates that microbial interdomain network complexity could be used as a bioindicator for ecological changes, which would helpful for improving ecological assessment of the freshwater eutrophication.


Environmental Monitoring , Microbiota , Environmental Monitoring/methods , Eutrophication , Fresh Water , Carbon
18.
Clin Cardiol ; 46(2): 134-141, 2023 Feb.
Article En | MEDLINE | ID: mdl-36378742

BACKGROUND: The Watchman device is the most widely used occluder but is indicated in atrial fibrillation (AF) patients with a maximal left atrial appendage (LAA) orifice diameter between 17 and 31 mm. We aimed to compare the long-term safety and efficacy of left atrial appendage closure (LAAC) between patients with a small LAA (<17 mm) and those with an indicated LAA (17-31 mm) measured by transesophageal echocardiography (TEE). METHODS: A total of 369 AF patients treated with LAAC between March 2015 and February 2019 were included and divided into two groups based on the maximal LAA orifice diameter measured by TEE: small LAA group (n = 22) and indicated LAA group (n = 347). Periprocedural complications and long-term clinical outcomes were compared. RESULTS: The Watchman device was successfully implanted in all patients. Mean device compression was higher in the small LAA group. Four patients (1.2%) in the indicated LAA group experienced pericardial effusion, and none experienced pericardial effusion in the small LAA group. Device-related thrombus was detected in one (4.5%) patient in the small LAA group and five (1.4%) in the indicated LAA group (p = .310). After a mean follow-up period of 4.1 ± 1.6 years, one patient in the small LAA group (4.5%; 1.1/100 person-years) and four in the indicated LAA group (1.2%; 0.3/100 person-years) suffered an ischemic stroke (p = .266). CONCLUSIONS: The safety and efficacy of LAAC with the Watchman device were comparable between patients with small and indicated LAA orifice diameters measured by TEE.


Atrial Appendage , Atrial Fibrillation , Pericardial Effusion , Humans , Echocardiography, Transesophageal , Treatment Outcome , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Pericardial Effusion/etiology , Cardiac Catheterization/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications
19.
J Formos Med Assoc ; 122(8): 707-713, 2023 Aug.
Article En | MEDLINE | ID: mdl-36463080

BACKGROUND: Pericardial effusion or pericardial tamponade (PE/PT) is a relatively common complication of left atrial appendage closure (LAAC). However, delayed PE/PT is rare with limited data. The aim of the study was to analyze the incidence and clinical consequences of delayed PE/PT following LAAC. METHODS: Patients with nonvalvular AF who were successfully implanted with LAAC devices from October 2014 to April 2021 were consecutively screened. Subjects experiencing delayed PE/PT after LAAC were included. All treatment sessions of the subjects were recorded in detail. After discharge, the patients were followed up for clinical outcomes. RESULTS: A total of 748 patients with successful LAAC [nitinol cage device (475 Watchman 2.5), nitinol plug device (131 ACP and 142 LAmbre)] were screened. Six patients experienced delayed PE/PT (1 Watchman, 2 ACP, 3 LAmbre). The incidence of delayed PE/PT was higher in patients with a nitinol plug device (1.8% vs. 0.2%, P = 0.027). Bloody PE only occurred in patients with a nitinol plug device (5/273, 1.8%). All the patients accepted pericardiocentesis and discontinuing antithrombotic medication, and none of the patients died or needed cardiac surgery. All patients were followed up for 810 (598, 1174) days after discharge. None of them developed constrictive pericarditis or thromboembolic or major bleeding events. CONCLUSION: Delayed PE/PT is rare but can occur, and the incidence of delayed bloody PE/PT for the nitinol plug device was higher than that for the nitinol cage device. The strategy of emergency pericardiocentesis combined with discontinuing antithrombotic medication may be effective for delayed bloody PE/PT.


Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Pericardial Effusion , Stroke , Humans , Pericardial Effusion/etiology , Pericardial Effusion/complications , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Treatment Outcome , Atrial Appendage/surgery , Fibrinolytic Agents , Cardiac Surgical Procedures/adverse effects , Stroke/etiology
20.
Environ Sci Pollut Res Int ; 30(4): 10426-10443, 2023 Jan.
Article En | MEDLINE | ID: mdl-36076137

Most of the studies are focused on influenza and meteorological factors for influenza. There are still few studies focused on the relationship between pollution factors and influenza, and the results are not consistent. This study conducted distributed lag nonlinear model and attributable risk on the relationship between influenza and pollution factors, aiming to quantify the association and provide a basis for the prevention of influenza and the formulation of relevant policies. Environmental data in Shijiazhuang from 2014 to 2019, as well as the data on hospital-confirmed influenza, were collected. When the concentration of PM2.5 was the highest (621 µg/m3), the relative risk was the highest (RR: 2.39, 95% CI: 1.10-5.17). For extremely high concentration PM2.5 (348 µg/m3), analysis of cumulative lag effect showed statistical significance from cumulative lag0-1 to lag0-6 day, and the minimum cumulative lag effect appeared in lag0-2 (RR: 0.760, 95% CI: 0.655-0.882). In terms of ozone, the RR value was 2.28(1.19,4.38), when O3 concentration was 310 µg/m3, and the RR was 1.65(1.26,2.15), when O3 concentration was 0 µg/m3. The RR of this lag effect increased with the increase of lag days, and reached the maximum at lag0-7 days, RR and 95% CI of slightly low concentration and extremely high concentration were 1.217(1.108,1.337) and 1.440(1.012,2.047), respectively. Stratified analysis showed that there was little difference in gender, but in different age groups, the cumulative lag effect of these two pollutants on influenza was significantly different. Our study found a non-linear relationship between two pollutants and influenza; slightly low concentrations were more associated with contaminant-related influenza. Health workers should encourage patients to get the influenza vaccine and wear masks when going out during flu seasons.


Air Pollutants , Air Pollution , Environmental Pollutants , Influenza Vaccines , Influenza, Human , Ozone , Humans , Ozone/analysis , Air Pollutants/analysis , Air Pollution/analysis , Incidence , Particulate Matter/analysis , Influenza, Human/epidemiology , Influenza Vaccines/analysis , Risk Factors , Environmental Pollutants/analysis , China/epidemiology , Environmental Exposure/analysis
...