Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Radiother Oncol ; 196: 110318, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38702015

RESUMEN

BACKGROUND AND PURPOSE: The use of Stereotactic Body Radiation Therapy (SBRT) in lung cancer is increasing. However, there is no consensus on the most appropriate treatment planning and delivery practice for lung SBRT. To gauge the range of practice, quantify its variability and identify where consensus might be achieved, ESTRO surveyed the medical physics community. MATERIALS AND METHODS: An online survey was distributed to ESTRO's physicist membership in 2022, covering experience, dose and fractionation, target delineation, dose calculation and planning practice, imaging protocols, and quality assurance. RESULTS: Two-hundred and forty-four unique answers were collected after data cleaning. Most respondents were from Europe the majority of which had more than 5 years' experience in SBRT. The large majority of respondents deliver lung SBRT with the VMAT technique on C-arm Linear Accelerators (Linacs) employing daily pre-treatment CBCT imaging. A broad spectrum of fractionation schemes were reported, alongside an equally wide range of dose prescription protocols. A clear preference was noted for prescribing to 95% or greater of the PTV. Several issues emerged regarding the dose calculation algorithm: 22% did not state it while 24% neglected to specify the conditions under which the dose was calculated. Contouring was usually performed on Maximum or Average Intensity Projection images while dose was mainly computed on the latter. No clear indications emerged for plan homogeneity, complexity, and conformity assessment. Approximately 40% of the responders participated in inter-centre credentialing of SBRT in the last five years. Substantial differences emerged between high and low experience centres, with the latter employing less accurate algorithms and older equipment. CONCLUSION: The survey revealed an evident heterogeneity in numerous aspects of the clinical implementation of lung SBRT treatments. International guidelines and codes of practice might promote harmonisation.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Radiocirugia/métodos , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Encuestas y Cuestionarios , Dosificación Radioterapéutica , Fraccionamiento de la Dosis de Radiación , Radioterapia de Intensidad Modulada/métodos , Europa (Continente)
2.
Artículo en Inglés | MEDLINE | ID: mdl-38549466

RESUMEN

BACKGROUND: The American Nurses Credentialing Center's (ANCC's) Practice Transition Accreditation Program (PTAP) establishes standards for nurse residency programs to elevate and optimize the skills, knowledge, and attitudes of new nurses participating in nurse residency programs. Evidence-based practice (EBP) is foundational to providing safe nursing care. One of the National Academy of Medicine's (NAM's) 2020 goals stated that 90% of clinical decisions would be supported by the best available evidence to attain the best patient outcomes. Nurse residency programs can benefit from evidence-based strategies to develop EBP competencies in new nurses. AIMS: The purpose of this scoping review was to synthesize the literature around strategies for incorporating EBP into nurse residency programs across the United States. METHODS: This scoping review was informed by the JBI (formerly known as the Joanna Briggs Institute) methodology for scoping reviews. Searches were conducted by a health science librarian in PubMed and CINAHL with Full Text. Keywords and their synonyms, Medical Subject Headings (MeSH; PubMed), and Subject Headings (CINAHL with Full Text) were used. Covidence, a literature review management program, was used to organize the literature and manage the review. Title, abstract, and full-text reviews were completed within Covidence using three teams of two independent reviewers. RESULTS: Four hundred and thirty-eight citations were imported into Covidence. Ten articles were retained for the final review. Three strategies for incorporating EBP into nurse residency programs emerged from the literature: (1) exposure of nurse residents to existing organizational resources, (2) completion of online EBP modules, and (3) completion of an EBP project. LINKING ACTION TO EVIDENCE: The incorporation of EBP competencies in nurse residency programs aligns with NAM's and ANCC's goals, yet a paucity of evidence exists to guide curriculum development in nurse residency programs. This scoping review corroborates the need for further research to inform best practices for implementing EBP into nurse residency programs.

3.
iScience ; 27(4): 109395, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38510122

RESUMEN

Although aging, repeat mild traumatic brain injury (RmTBI), and microbiome modifications independently change social behavior, there has been no investigation into their cumulative effects on social behavior and neuroplasticity within the prefrontal cortex. Therefore, we examined how microbiome depletion prior to RmTBI affected social behavior and neuroplasticity in adolescent and adult rats. Play, temperament analysis, elevated plus maze, and the hot/cold plate assessed socio-emotional function. Analyses of perineuronal nets (PNNs) and parvalbumin (PV) interneurons was completed. Social-emotional deficits were more pronounced in adults, with microbiome depletion attenuating social behavior deficits associated with RmTBI in both age groups. Microbiome depletion increased branch length and PNN arborization within the PFC but decreased the overall number of PNNs. Adults and males were more vulnerable to RmTBI. Interestingly, microbiome depletion may have attenuated the changes to neuroplasticity and subsequent social deficits, suggesting that the microbiome is a viable, but age-specific, target for RmTBI therapeutics.

4.
Clin Transl Radiat Oncol ; 36: 132-139, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36034326

RESUMEN

Purpose: To describe cardiac exposure from breast cancer radiotherapy regimens used during 1970-2009 for the development of dose-response relationships and to consider the associated radiation-risks using existing dose-response relationships. Material and methods: Radiotherapy charts for 771 women in the Netherlands selected for case control studies of heart disease after breast cancer radiotherapy were used to reconstruct 44 regimens on a typical CT-dataset. Doses were estimated for the whole heart (WH), left ventricle (LV) and cardiac valves. Results: For breast/chest wall radiotherapy average WH doses decreased during 1970-2009. For internal mammary chain (IMC) radiotherapy WH doses were highest during the 1980s and 1990s when direct anterior fields were used and reduced in the 2000s when oblique fields were introduced. Average doses varied substantially for IMC regimens (WH 2-33 Gy, LV < 1-23 Gy). For cardiac valves, at least one valve received >30 Gy from most regimens. Conclusions: Radiation-risks of IHD from breast/chest wall regimens likely reduced during 1970-2009. Direct anterior IMC regimens likely increased the risks of IHD and VHD over this time period but the use of oblique IMC fields from 2003 may have lowered these risks. These data provide a unique opportunity to develop dose-response relationships.

5.
Pract Radiat Oncol ; 9(3): 158-171, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30690085

RESUMEN

PURPOSE: Incidental cardiac exposure during radiation therapy may cause heart disease. Dose-response relationships for cardiac structures (segments) may show which ones are most sensitive to radiation. Radiation-related cardiac injury can take years to develop; thus, studies need to involve women treated using 2-dimensional planning, with segment doses estimated using a typical computed tomography (CT) scan. We assessed whether such segment doses are accurate enough to use in dose-response relationships using the radiation therapy charts of women with known segment injury. We estimated interregimen and interpatient segment dose variability and segment dose correlations. METHODS AND MATERIALS: The radiation therapy charts of 470 women with cardiac segment injury after breast cancer radiation therapy were examined, and 41 regimens were identified. Regimens were reconstructed on a typical CT scan. Doses were estimated for 5 left ventricle (LV) and 10 coronary artery segments. Correlations between cardiac segments were estimated. Interpatient dose variation was assessed in 10 randomly selected CT scans for left regimens and in 5 for right regimens. RESULTS: For the typical CT scan, interregimen segment dose variation was substantial (range, LV segments <1-39 Gy; coronary artery segments <1-48 Gy). In 10 CT scans, interpatient segment dose variation was higher for segments near field borders (range, 3-47 Gy) than other segments (range, <2 Gy). Doses to different left-anterior descending coronary artery (LADCA) segments were highly correlated with each other, as were doses to different LV segments. Also, LADCA segment doses were highly correlated with doses to LV segments usually supplied by the LADCA. For individual regimens there was consistency in hotspot location and segment ranking of higher-versus-lower dose. CONCLUSIONS: The scope for developing quantitative cardiac segment dose-response relationships in patients who had 2-dimensional planning is limited because different segment doses are often highly correlated, and segment-specific dose uncertainties are not independent of each other. However, segment-specific doses may be reliably used to rank segments according to higher-versus-lower doses.


Asunto(s)
Neoplasias de la Mama/radioterapia , Corazón/efectos de la radiación , Traumatismos por Radiación/etiología , Planificación de la Radioterapia Asistida por Computador/efectos adversos , Relación Dosis-Respuesta en la Radiación , Estudios Epidemiológicos , Femenino , Humanos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X
6.
Phys Med ; 47: 129-138, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29331227

RESUMEN

Stereotactic body radiotherapy (SBRT) for lung tumours has been gaining wide acceptance in lung cancer. Here, we review the technological evolution of SBRT delivery in lung cancer, from the first treatments using the stereotactic body frame in the 1990's to modern developments in image guidance and motion management. Finally, we discuss the impact of current technological approaches on the requirements for quality assurance as well as future technological developments.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Radiocirugia/métodos , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
7.
Int J Radiat Oncol Biol Phys ; 99(3): 729-737, 2017 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29280467

RESUMEN

PURPOSE: Radiation therapy dose escalation using a simultaneous integrated boost (SIB) is predicted to improve local tumor control in esophageal cancer; however, any increase in acute hematologic toxicity (HT) could limit the predicted improvement in patient outcomes. Proton therapy has been shown to significantly reduce HT in lung cancer patients receiving concurrent chemotherapy. Therefore, we investigated the potential of bone marrow sparing with protons for esophageal tumors. METHODS AND MATERIALS: Twenty-one patients with mid-esophageal cancer who had undergone conformal radiation therapy (3D50) were selected. Two surrogates for bone marrow were created by outlining the thoracic bones (bone) and only the body of the thoracic vertebrae (TV) in Eclipse. The percentage of overlap of the TV with the planning treatment volume was recorded for each patient. Additional plans were created retrospectively, including a volumetric modulated arc therapy (VMAT) plan with the same dose as for 3D50; a VMAT SIB plan with a dose prescription of 62.5 Gy to the high-risk subregion within the planning treatment volume; a reoptimized TV-sparing VMAT plan; and a proton therapy plan with the same SIB dose prescription. The bone and TV dose metrics were recorded and compared across all plans and variations with respect to PTV and percentage of overlap for each patient. RESULTS: The 3D50 plans showed the highest bone mean dose and TV percentage of volume receiving ≥30 Gy (V30Gy) for each patient. The VMAT plans irradiated a larger bone V10Gy than did the 3D50 plans. The reoptimized VMAT62.5 VT plans showed improved sparing of the TV volume, but only the proton plans showed significant sparing for bone V10Gy and bone mean dose, especially for patients with a larger PTV. CONCLUSIONS: The results of the present study have shown that proton therapy can reduced bone marrow toxicity.


Asunto(s)
Médula Ósea/efectos de la radiación , Quimioradioterapia/métodos , Neoplasias Esofágicas/terapia , Tratamientos Conservadores del Órgano/métodos , Terapia de Protones/métodos , Traumatismos por Radiación/prevención & control , Radioterapia de Intensidad Modulada/métodos , Neoplasias Esofágicas/diagnóstico por imagen , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/efectos de la radiación
8.
Br J Radiol ; 90(1076): 20160939, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28540739

RESUMEN

Oxygen distribution is a major determinant of treatment success in radiotherapy, with well-oxygenated tumour regions responding by up to a factor of three relative to anoxic volumes. Conversely, tumour hypoxia is associated with treatment resistance and negative prognosis. Tumour oxygenation is highly heterogeneous and difficult to measure directly. The recent advent of functional hypoxia imaging modalities such as fluorine-18 fluoromisonidazole positron emission tomography have shown promise in non-invasively determining regions of low oxygen tension. This raises the prospect of selectively increasing dose to hypoxic subvolumes, a concept known as dose painting. Yet while this is a promising approach, oxygen-mediated radioresistance is inherently a multiscale problem, and there are still a number of substantial challenges that must be overcome if hypoxia dose painting is to be successfully implemented. Current imaging modalities are limited by the physics of such systems to have resolutions in the millimetre regime, whereas oxygen distribution varies over a micron scale, and treatment delivery is typically modulated on a centimetre scale. In this review, we examine the mechanistic basis and implications of the radiobiological oxygen effect, the factors influencing microscopic heterogeneity in tumour oxygenation and the consequent challenges in the interpretation of clinical hypoxia imaging (in particular fluorine-18 fluoromisonidazole positron emission tomography). We also discuss dose-painting approaches and outline challenges that must be addressed to improve this treatment paradigm.


Asunto(s)
Hipoxia/fisiopatología , Misonidazol/análogos & derivados , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Tomografía de Emisión de Positrones , Fármacos Sensibilizantes a Radiaciones , Hipoxia de la Célula , Humanos , Dosificación Radioterapéutica
9.
Radiother Oncol ; 122(3): 416-422, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28233564

RESUMEN

BACKGROUND AND PURPOSE: The heart is a complex anatomical organ and contouring the cardiac substructures is challenging. This study presents a reproducible method for contouring left ventricular and coronary arterial segments on radiotherapy CT-planning scans. MATERIAL AND METHODS: Segments were defined from cardiology models and agreed by two cardiologists. Reference atlas contours were delineated and written guidelines prepared. Six radiation oncologists tested the atlas. Spatial variation was assessed using the DICE similarity coefficient (DSC) and the directed Hausdorff average distance (d→H,avg). The effect of spatial variation on doses was assessed using six different breast cancer regimens. RESULTS: The atlas enabled contouring of 15 cardiac segments. Inter-observer contour overlap (mean DSC) was 0.60-0.73 for five left ventricular segments and 0.10-0.53 for ten coronary arterial segments. Inter-observer contour separation (mean d→H,avg) was 1.5-2.2mm for left ventricular segments and 1.3-5.1mm for coronary artery segments. This spatial variation resulted in <1Gy dose variation for most regimens and segments, but 1.2-21.8Gy variation for segments close to a field edge. CONCLUSIONS: This cardiac atlas enables reproducible contouring of segments of the left ventricle and main coronary arteries to facilitate future studies relating cardiac radiation doses to clinical outcomes.


Asunto(s)
Neoplasias de la Mama/radioterapia , Corazón/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Vasos Coronarios/efectos de la radiación , Femenino , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/efectos de la radiación , Humanos
10.
Int J Radiat Oncol Biol Phys ; 95(1): 199-207, 2016 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27084641

RESUMEN

PURPOSE: Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. METHODS AND MATERIALS: For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV)50Gy or PTV62.5Gy (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose-volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. RESULTS: SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D98 was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D98 was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D98 was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D98 was lower by 0.3% to 2.2% of the prescribed GTV dose. CONCLUSIONS: The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial.


Asunto(s)
Neoplasias Esofágicas/radioterapia , Tratamientos Conservadores del Órgano/métodos , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Puntos Anatómicos de Referencia/diagnóstico por imagen , Huesos/diagnóstico por imagen , Neoplasias Esofágicas/patología , Corazón/efectos de la radiación , Humanos , Pulmón/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/prevención & control , Radiografía , Dosificación Radioterapéutica , Errores de Configuración en Radioterapia , Incertidumbre
11.
Radiat Oncol ; 10: 236, 2015 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-26586375

RESUMEN

PURPOSE: Using radiobiological modelling to estimate normal tissue toxicity, this study investigates the effects of dose escalation for concurrent chemoradiation therapy (CRT) in lower third oesophageal tumours on the stomach. METHODS AND MATERIALS: 10 patients with lower third oesophageal cancer were selected from the SCOPE 1 database (ISCRT47718479) with a mean planning target volume (PTV) of 348 cm(3). The original 3D conformal plans (50 Gy3D) were compared to newly created RapidArc plans of 50 GyRA and 60 GyRA, the latter using a simultaneous integrated boost (SIB) technique using a boost volume, PTV2. Dose-volume metrics and estimates of normal tissue complication probability (NTCP) were compared. RESULTS: There was a significant increase in NTCP of the stomach wall when moving from the 50 GyRA to the 60 GyRA plans (11-17 %, Wilcoxon signed rank test, p = 0.01). There was a strong correlation between the NTCP values of the stomach wall and the volume of the stomach wall/PTV 1 and stomach wall/PTV2 overlap structures (R = 0.80 and R = 0.82 respectively) for the 60 GyRA plans. CONCLUSION: Radiobiological modelling suggests that increasing the prescribed dose to 60 Gy may be associated with a significantly increased risk of toxicity to the stomach. It is recommended that stomach toxicity be closely monitored when treating patients with lower third oesophageal tumours with 60 Gy.


Asunto(s)
Neoplasias Esofágicas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Estómago/efectos de la radiación , Humanos , Modelos Teóricos , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/prevención & control , Dosificación Radioterapéutica
12.
Radiat Oncol ; 9: 286, 2014 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-25533761

RESUMEN

AIM: To investigate systematic changes in dose arising when treatment plans optimised using the Anisotropic Analytical Algorithm (AAA) are recalculated using Acuros XB (AXB) in patients treated with definitive chemoradiotherapy (dCRT) for locally advanced oesophageal cancers. BACKGROUND: We have compared treatment plans created using AAA with those recalculated using AXB. Although the Anisotropic Analytical Algorithm (AAA) is currently more widely used in clinical routine, Acuros XB (AXB) has been shown to more accurately calculate the dose distribution, particularly in heterogeneous regions. Studies to predict clinical outcome should be based on modelling the dose delivered to the patient as accurately as possible. METHODS: CT datasets from ten patients were selected for this retrospective study. VMAT (Volumetric modulated arc therapy) plans with 2 arcs, collimator rotation ± 5-10° and dose prescription 50 Gy / 25 fractions were created using Varian Eclipse (v10.0). The initial dose calculation was performed with AAA, and AXB plans were created by re-calculating the dose distribution using the same number of monitor units (MU) and multileaf collimator (MLC) files as the original plan. The difference in calculated dose to organs at risk (OAR) was compared using dose-volume histogram (DVH) statistics and p values were calculated using the Wilcoxon signed rank test. The potential clinical effect of dosimetric differences in the gross tumour volume (GTV) was evaluated using three different TCP models from the literature. RESULTS: PTV Median dose was apparently 0.9 Gy lower (range: 0.5 Gy - 1.3 Gy; p < 0.05) for VMAT AAA plans re-calculated with AXB and GTV mean dose was reduced by on average 1.0 Gy (0.3 Gy -1.5 Gy; p < 0.05). An apparent difference in TCP of between 1.2% and 3.1% was found depending on the choice of TCP model. OAR mean dose was lower in the AXB recalculated plan than the AAA plan (on average, dose reduction: lung 1.7%, heart 2.4%). Similar trends were seen for CRT plans. CONCLUSIONS: Differences in dose distribution are observed with VMAT and CRT plans recalculated with AXB particularly within soft tissue at the tumour/lung interface, where AXB has been shown to more accurately represent the true dose distribution. AAA apparently overestimates dose, particularly the PTV median dose and GTV mean dose, which could result in a difference in TCP model parameters that reaches clinical significance.


Asunto(s)
Algoritmos , Neoplasias Esofágicas/radioterapia , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Esofágicas/diagnóstico por imagen , Humanos , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Probabilidad , Dosificación Radioterapéutica/normas , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
13.
Int J Radiat Oncol Biol Phys ; 90(2): 423-9, 2014 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-25304796

RESUMEN

PURPOSE: This study investigated the trade-off in tumor coverage and organ-at-risk sparing when applying dose escalation for concurrent chemoradiation therapy (CRT) of mid-esophageal cancer, using radiobiological modeling to estimate local control and normal tissue toxicity. METHODS AND MATERIALS: Twenty-one patients with mid-esophageal cancer were selected from the SCOPE1 database (International Standard Randomised Controlled Trials number 47718479), with a mean planning target volume (PTV) of 327 cm(3). A boost volume, PTV2 (GTV + 0.5 cm margin), was created. Radiobiological modeling of tumor control probability (TCP) estimated the dose required for a clinically significant (+20%) increase in local control as 62.5 Gy/25 fractions. A RapidArc (RA) plan with a simultaneously integrated boost (SIB) to PTV2 (RA62.5) was compared to a standard dose plan of 50 Gy/25 fractions (RA50). Dose-volume metrics and estimates of normal tissue complication probability (NTCP) for heart and lungs were compared. RESULTS: Clinically acceptable dose escalation was feasible for 16 of 21 patients, with significant gains (>18%) in tumor control from 38.2% (RA50) to 56.3% (RA62.5), and only a small increase in predicted toxicity: median heart NTCP 4.4% (RA50) versus 5.6% (RA62.5) P<.001 and median lung NTCP 6.5% (RA50) versus 7.5% (RA62.5) P<.001. CONCLUSIONS: Dose escalation to the GTV to improve local control is possible when overlap between PTV and organ-at-risk (<8% heart volume and <2.5% lung volume overlap for this study) generates only negligible increase in lung or heart toxicity. These predictions from radiobiological modeling should be tested in future clinical trials.


Asunto(s)
Quimioradioterapia/efectos adversos , Fraccionamiento de la Dosis de Radiación , Neoplasias Esofágicas/terapia , Corazón/efectos de la radiación , Pulmón/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Quimioradioterapia/métodos , Neoplasias Esofágicas/patología , Estudios de Factibilidad , Humanos , Modelos Biológicos , Probabilidad , Carga Tumoral
14.
Int J Radiat Oncol Biol Phys ; 88(5): 1148-53, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24529713

RESUMEN

PURPOSE: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. METHODS AND MATERIALS: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D99) delivered to 99% of the planning target volume (PTV) was determined. RESULTS: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D99, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). CONCLUSIONS: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Neumonitis por Radiación/prevención & control , Radioterapia Conformacional/instrumentación , Radioterapia Conformacional/métodos , Relación Dosis-Respuesta en la Radiación , Tomografía Computarizada Cuatridimensional , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Riesgo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
PLoS One ; 8(11): e81027, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24282564

RESUMEN

The H1N1 subtype of influenza A virus has caused two of the four documented pandemics and is responsible for seasonal epidemic outbreaks, presenting a continuous threat to public health. Co-circulating antigenically divergent influenza strains significantly complicates vaccine development and use. Here, by combining evolutionary, structural, functional, and population information about the H1N1 proteome, we seek to answer two questions: (1) do residues on the protein surfaces evolve faster than the protein core residues consistently across all proteins that constitute the influenza proteome? and (2) in spite of the rapid evolution of surface residues in influenza proteins, are there any protein regions on the protein surface that do not evolve? To answer these questions, we first built phylogenetically-aware models of the patterns of surface and interior substitutions. Employing these models, we found a single coherent pattern of faster evolution on the protein surfaces that characterizes all influenza proteins. The pattern is consistent with the events of inter-species reassortment, the worldwide introduction of the flu vaccine in the early 80's, as well as the differences caused by the geographic origins of the virus. Next, we developed an automated computational pipeline to comprehensively detect regions of the protein surface residues that were 100% conserved over multiple years and in multiple host species. We identified conserved regions on the surface of 10 influenza proteins spread across all avian, swine, and human strains; with the exception of a small group of isolated strains that affected the conservation of three proteins. Surprisingly, these regions were also unaffected by genetic variation in the pandemic 2009 H1N1 viral population data obtained from deep sequencing experiments. Finally, the conserved regions were intrinsically related to the intra-viral macromolecular interaction interfaces. Our study may provide further insights towards the identification of novel protein targets for influenza antivirals.


Asunto(s)
Evolución Biológica , Subtipo H1N1 del Virus de la Influenza A/metabolismo , Proteínas Virales/metabolismo , Subtipo H1N1 del Virus de la Influenza A/clasificación , Subtipo H1N1 del Virus de la Influenza A/genética , Filogenia , Proteínas Virales/genética
16.
Pain Med ; 14(12): 1918-32, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24102928

RESUMEN

OBJECTIVE: To compare the efficacy of high-dose (3,600 mg/day) vs low-dose (1,200 mg/day) oral gabapentin enacarbil (GEn) on pain intensity in adults with postherpetic neuralgia (PHN) and a history of inadequate response to ≥1,800 mg/day gabapentin. DESIGN: Multicenter, randomized, double-blind, crossover study (NCT00617461). SETTING: Thirty-five outpatient centers in Germany and the United States. SUBJECTS: Subjects aged ≥18 years with a diagnosis of PHN. METHODS: During a 2-week baseline period, subjects received open-label treatment with 1,800 mg/day gabapentin. Subjects who had a mean 24-hour average pain intensity score ≥4 during the last 7 days of the baseline period were randomized to receive GEn (1,200 or 3,600 mg/day) for treatment period 1 (28 days), followed by GEn 2,400 mg/day (4 days), and the alternate GEn dose for treatment period 2 (28 days). RESULTS: There was a modest but significant improvement in pain intensity scores with GEn 3,600 mg vs 1,200 mg (adjusted mean [90% confidence interval] treatment difference, -0.29 [-0.48 to -0.10]; P = 0.013). The difference in efficacy between doses was observed primarily in subjects who received the higher dose during treatment period 2; certain aspects of the study design may have contributed to this outcome. Plasma steady-state gabapentin exposure during GEn treatment was as expected and consistent between treatment periods. No new safety signals or adverse event trends relating to GEn exposure were identified. CONCLUSIONS: While the overall results demonstrated efficacy in a PHN population, the differences between treatment periods confound the interpretation. These findings could provide insight into future trial designs.


Asunto(s)
Analgésicos/administración & dosificación , Carbamatos/administración & dosificación , Neuralgia Posherpética/tratamiento farmacológico , Profármacos/administración & dosificación , Ácido gamma-Aminobutírico/análogos & derivados , Adulto , Anciano , Anciano de 80 o más Años , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Resultado del Tratamiento , Ácido gamma-Aminobutírico/administración & dosificación
18.
Radiother Oncol ; 107(2): 200-6, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23647755

RESUMEN

BACKGROUND AND PURPOSE: Contouring of target volumes varies significantly in radiotherapy of pancreatic ductal adenocarcinoma (PDAC). There is a lack of consensus as to whether elective lymph nodes (eLN's) should be included or not in the planning target volume (PTV). In the present study we analyzed the dosimetric coverage of the eLN's and organs at risk (OAR) by comparing four different contouring guidelines. METHODS AND MATERIALS: PTVs were delineated with (Oxford and RTOG guidelines) or without (Michigan and SCALOP guidelines) including the eLNs in eleven patients with PDAC. eLNs included the peripancreatic, paraaortic, paracaval, celiac trunk, superior mesenteric and portal vein clinical target volumes (CTVs). A 3D-CRT plan (50.40 Gy in 28 fractions) was performed to analyze and compare the dosimetric coverage of all eLNs and OAR between the 4 contouring guidelines. RESULTS: The size of Oxford and RTOG PTVs was comparable and significantly larger than the SCALOP and Michigan PTVs. Interestingly the eLNs received a significant amount of incidental dose irradiation by PTV-based plans that only aimed to treat the tumor without the eLNs. The dosimetric coverage of eLN presented a large variability according to the respective contouring methods. The difference in the size of the 4 PTVs was reflected to the dose distribution at the OAR. CONCLUSIONS: Our study provides important information regarding the impact of different contouring guidelines on the dose distribution to the eLNs and the OAR in patients with locally advanced PDAC treated with radiotherapy.


Asunto(s)
Adenocarcinoma/radioterapia , Carcinoma Ductal Pancreático/radioterapia , Neoplasias Pancreáticas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Carcinoma Ductal Pancreático/patología , Humanos , Órganos en Riesgo , Neoplasias Pancreáticas/patología , Guías de Práctica Clínica como Asunto , Dosificación Radioterapéutica , Carga Tumoral
19.
J Pain ; 14(6): 590-603, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23602345

RESUMEN

UNLABELLED: Gabapentin enacarbil (GEn) is an actively transported prodrug of gabapentin that provides sustained, dose-proportional exposure to gabapentin. This randomized, double-blind, parallel-group, placebo-controlled study evaluated the safety and efficacy of 3 different maintenance doses of oral GEn in subjects with postherpetic neuralgia. Adults with a 24-hour average pain intensity score of ≥4.0 received GEn 1,200 mg, 2,400 mg, 3,600 mg, or placebo for 14 weeks (including a 1-week up-titration, 12-week maintenance, and 1-week taper). The primary endpoint was change from baseline to end of maintenance treatment in mean 24-hour average pain intensity score. The intent-to-treat population consisted of 371 subjects (GEn 1,200 mg = 107, 2,400 mg = 82, 3,600 mg = 87, placebo = 95). With regard to the primary endpoint, all 3 GEn treatment groups demonstrated a statistically significant difference relative to placebo. The adjusted mean change from baseline for the treatment groups ranged from -2.36 to -2.72 versus -1.66 for the placebo group. Exposure-response modeling suggested an ED50 around 1,200 mg/day, which was consistent with historical findings reported for gabapentin. The most commonly reported adverse events were dizziness and somnolence. All studied doses of GEn significantly improved pain associated with postherpetic neuralgia as compared to placebo and were well tolerated. PERSPECTIVE: GEn provides clinically important pain relief with doses from 1,200 mg to 3,600 mg and is generally well tolerated and efficacious. As an actively transported prodrug of gabapentin, it provides dose-proportional and extended exposure to gabapentin.


Asunto(s)
Anestésicos/uso terapéutico , Carbamatos/uso terapéutico , Neuralgia Posherpética/diagnóstico , Neuralgia Posherpética/tratamiento farmacológico , Ácido gamma-Aminobutírico/análogos & derivados , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven , Ácido gamma-Aminobutírico/uso terapéutico
20.
Nature ; 492(7428): 256-60, 2012 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-23235880

RESUMEN

Soybean (Glycine max (L.) Merr.) is an important crop that provides a sustainable source of protein and oil worldwide. Soybean cyst nematode (Heterodera glycines Ichinohe) is a microscopic roundworm that feeds on the roots of soybean and is a major constraint to soybean production. This nematode causes more than US$1 billion in yield losses annually in the United States alone, making it the most economically important pathogen on soybean. Although planting of resistant cultivars forms the core management strategy for this pathogen, nothing is known about the nature of resistance. Moreover, the increase in virulent populations of this parasite on most known resistance sources necessitates the development of novel approaches for control. Here we report the map-based cloning of a gene at the Rhg4 (for resistance to Heterodera glycines 4) locus, a major quantitative trait locus contributing to resistance to this pathogen. Mutation analysis, gene silencing and transgenic complementation confirm that the gene confers resistance. The gene encodes a serine hydroxymethyltransferase, an enzyme that is ubiquitous in nature and structurally conserved across kingdoms. The enzyme is responsible for interconversion of serine and glycine and is essential for cellular one-carbon metabolism. Alleles of Rhg4 conferring resistance or susceptibility differ by two genetic polymorphisms that alter a key regulatory property of the enzyme. Our discovery reveals an unprecedented plant resistance mechanism against a pathogen. The mechanistic knowledge of the resistance gene can be readily exploited to improve nematode resistance of soybean, an increasingly important global crop.


Asunto(s)
Glycine max/genética , Glycine max/parasitología , Interacciones Huésped-Parásitos , Nematodos/fisiología , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo , Secuencia de Aminoácidos , Animales , Análisis Mutacional de ADN , Orden Génico , Silenciador del Gen , Prueba de Complementación Genética , Glicina Hidroximetiltransferasa/genética , Glicina Hidroximetiltransferasa/metabolismo , Haplotipos , Modelos Moleculares , Datos de Secuencia Molecular , Proteínas de Plantas/química , Polimorfismo Genético/genética , Estructura Terciaria de Proteína , Sitios de Carácter Cuantitativo/genética , Glycine max/enzimología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA