Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JACC Case Rep ; 10: 101760, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36974056

RESUMEN

The authors report a closed-chest, transcatheter large-vessel connection (hepatic conduit to azygous vein) to reverse pulmonary arteriovenous malformations in a 10-year-old patient after Fontan for heterotaxy/interrupted inferior vena cava, with an increase in oxygen saturation from 78% to 96%. Computational fluid dynamics estimated a 14-fold increase in hepatic blood flow to the left pulmonary artery (from 1.3% to 14%). (Level of Difficulty: Advanced.).

2.
Ann Biomed Eng ; 48(10): 2400-2411, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32415483

RESUMEN

Thrombosis in post-transcatheter aortic valve replacement (TAVR) patients has been correlated with flow stasis in the neo-sinus. This study investigated the effect of the post-TAVR geometry on flow stasis. Computed tomography angiography of 155 patients who underwent TAVR using a SAPIEN 3 were used to identify patients with and without thrombosis, and quantify thrombus volumes. Six patients with 23-mm SAPIEN 3 valves were then selected from the cohort and used to create patient-specific post-TAVR computational fluid dynamic models. Regions of flow stasis (%Volstasis, velocities below 0.05 m/s) were identified. The results showed that all post-TAVR anatomical measurements were significantly different in patients with and without thrombus, but only sinus diameter had a linear correlation with thrombus volume (r = 0.471, p = 0.008). A linear correlation was observed between %Volstasis and thrombus volume (r = 0.821, p = 0.007). The combination of anatomy and valve deployment created a unique geometry in each patient, which when combined with patient-specific cardiac output, resulted in distinct flow patterns. While parametric studies have shown individual anatomical or deployment metrics may relate to flow stasis, the combined effects of these metrics potentially contributes to the biomechanical environment promoting thrombosis, therefore hemodynamic studies of TAVR should account for these patient-specific factors.


Asunto(s)
Circulación Coronaria , Modelos Cardiovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Simulación por Computador , Femenino , Humanos , Masculino , Trombosis/diagnóstico por imagen , Trombosis/fisiopatología
3.
Ann Biomed Eng ; 47(6): 1422-1434, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30859434

RESUMEN

Computational modeling can be used to improve understanding of tricuspid valve (TV) biomechanics and supplement knowledge gained from benchtop and large animal experiments. The aim of this study was to develop a computational model of the TV using high resolution micro-computed tomography (µCT) imaging and fluid-structure interaction simulations. A three-dimensional TV model, incorporating detailed leaflet and chordal geometries, was reconstructed from µCT images of an excised porcine TV obtained under diastolic conditions. The leaflets were described using non-linear stress-strain relations and chordal properties were iteratively adjusted until valve closure was obtained. The leaflet coaptation zone obtained from simulation of valve closure was validated against µCT images of the TV captured at peak systole. The computational model was then used to simulate a regurgitant TV morphology and investigate changes in closure dynamics. Overall, the mean stresses in the leaflet belly region and the chordae tendinae of the regurgitant TV were 7% and 3% higher than the same regions of the normal TV. The maximum principal strain in the leaflet belly of the regurgitant TV was also 9% higher than the same regions of the normal TV. It is anticipated that this computational model can be used in future studies for further understanding of TV biomechanics and associated percutaneous repairs.


Asunto(s)
Modelos Cardiovasculares , Válvula Tricúspide/fisiología , Animales , Simulación por Computador , Análisis de Elementos Finitos , Porcinos , Válvula Tricúspide/diagnóstico por imagen , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...