Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 202-7, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16604627

RESUMEN

Researchers at the INEEL, MSU, LLNL and UCD have undertaken development of MINERVA, a patient-centric, multi-modal, radiation treatment planning system, which can be used for planning and analysing several radiotherapy modalities, either singly or combined, using common treatment planning tools. It employs an integrated, lightweight plugin architecture to accommodate multi-modal treatment planning using standard interface components. The design also facilitates the future integration of improved planning technologies. The code is being developed with the Java programming language for interoperability. The MINERVA design includes the image processing, model definition and data analysis modules with a central module to coordinate communication and data transfer. Dose calculation is performed by source and transport plugin modules, which communicate either directly through the database or through MINERVA's openly published, extensible markup language (XML)-based application programmer's interface (API). All internal data are managed by a database management system and can be exported to other applications or new installations through the API data formats. A full computation path has been established for molecular-targeted radiotherapy treatment planning, with additional treatment modalities presently under development.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Lenguajes de Programación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos , Interfaz Usuario-Computador , Carga Corporal (Radioterapia) , Dosis de Radiación , Efectividad Biológica Relativa , Diseño de Software , Integración de Sistemas
2.
Appl Radiat Isot ; 61(5): 745-52, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15308138

RESUMEN

Researchers at the Idaho National Engineering and Environmental Laboratory and Montana State University have undertaken development of MINERVA, a patient-centric, multi-modal, radiation treatment planning system. This system can be used for planning and analyzing several radiotherapy modalities, either singly or combined, using common modality independent image and geometry construction and dose reporting and guiding. It employs an integrated, lightweight plugin architecture to accommodate multi-modal treatment planning using standard interface components. The MINERVA design also facilitates the future integration of improved planning technologies. The code is being developed with the Java Virtual Machine for interoperability. A full computation path has been established for molecular targeted radiotherapy treatment planning, with the associated transport plugin developed by researchers at the Lawrence Livermore National Laboratory. Development of the neutron transport plugin module is proceeding rapidly, with completion expected later this year. Future development efforts will include development of deformable registration methods, improved segmentation methods for patient model definition, and three-dimensional visualization of the patient images, geometry, and dose data. Transport and source plugins will be created for additional treatment modalities, including brachytherapy, external beam proton radiotherapy, and the EGSnrc/BEAMnrc codes for external beam photon and electron radiotherapy.


Asunto(s)
Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Neoplasias Encefálicas/radioterapia , Terapia Combinada , Gráficos por Computador , Humanos , Programas Informáticos , Interfaz Usuario-Computador
3.
Appl Radiat Isot ; 61(5): 805-10, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15308148

RESUMEN

This work evaluates the performance of two NCT treatment planning systems: NCTPlan, developed by the CNEA and the Harvard-MIT group, and SERA, developed by the INEEL/Montana State University group. The study was performed in some simple geometries with the therapeutical hyperthermal beam of the RA-6 facility at Bariloche, Argentina. The first geometry was a rectangular phantom and calculations and measurements were made along the central beam axis and along a parellel axis, 4 cm apart from the central beam axis. Measurements and calculations were also performed in a cylindrical phantom, to explore the behavior of the treatment planning systems in a geometry simulating an extremity, in accordance with the CNEA clinical protocol. Comments on differences in source definitions and cross sections libraries are also included in the text. It can be seen that both codes give acceptable results on the central beam axis and on a lateral axis, showing good agreement with experimental results.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Planificación de la Radioterapia Asistida por Computador , Argentina , Terapia por Captura de Neutrón de Boro/métodos , Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Neutrones Rápidos/uso terapéutico , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos
4.
Appl Radiat Isot ; 61(5): 993-6, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15308181

RESUMEN

An epithermal neutron beam facility for preclinical neutron capture therapy research has been constructed at the Washington State University TRIGA research reactor installation. Subsequent to a recent upgrade, this new facility offers a high-purity epithermal beam with intensity on the order of 1.2x10(9)n/cm(2)s. Key features include a fluoride-based design for the neutron filtering and moderating components as well as a novel collimator design that allows ease of assembly and disassembly of the beamline components.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Animales , Diseño de Equipo , Arquitectura y Construcción de Instituciones de Salud , Humanos , Washingtón
5.
Med Phys ; 27(2): 359-67, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10718140

RESUMEN

A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essentially the same fast-neutron physical depth-dose distribution as is produced by the current UW clinical system, but that also has an increased fraction of BNCT enhancement relative to the total therapeutic dose. The modified target is composed of a 5-millimeter layer of beryllium, followed by a 2.5-millimeter layer of tungsten, with a water-cooled copper backing. Measurements of the free-field neutron spectrum of the beam produced by the new target were performed using activation foils with a direct spectral unfolding technique. Water phantom measurements were performed using a tissue-equivalent ion chamber to characterize the fast-neutron depth-dose curve and sodium activation in soda-lime glass beads to characterize the thermal-neutron flux (and thus the expected neutron capture dose enhancement) as a function of depth. The results of the various measurements were quite consistent with expectations based on the design calculations for the modified target. The spectrum of the neutron beam produced by the new target features an enhanced low-energy flux component relative to the spectrum of the beam produced by the standard UW target. However, it has essentially the same high-energy neutron flux, with a reduced flux component in the mid-range of the energy spectrum. As a result, the measured physical depth-dose curve in a large water phantom has the same shape compared to the case of the standard UW clinical beam, but approximately twice the level of BNCT enhancement per unit background neutron dose at depths of clinical interest. In-vivo clinical testing of BNCT-enhanced fast-neutron therapy for canine lung tumors using the new beam was recently initiated.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neutrones Rápidos/uso terapéutico , Animales , Terapia por Captura de Neutrón de Boro/instrumentación , Ciclotrones , Enfermedades de los Perros/radioterapia , Perros , Diseño de Equipo , Hospitales Universitarios , Humanos , Aumento de la Imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/veterinaria , Fantasmas de Imagen , Oncología por Radiación , Washingtón , Agua