Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985183

RESUMEN

OBJECTIVES: To evaluate a three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence using a long repetition time (TR) and constant flip angle (CFA) in differentiating between perilymph and endolymph in a phantom study, and unenhanced endolymphatic hydrops (EH) imaging in a patient study. METHODS: Three solutions in similar ion and protein concentrations with endolymph, perilymph, and cerebrospinal fluid were prepared for variable flip angle (VFA) 3D-FLAIR (TR 10,000 ms) and CFA (120°) 3D-FLAIR using different TR (10,000, 16,000, and 20,000 ms). Fifty-two patients with probable or definite Meniere's disease received unenhanced CFA (120°) 3D-FLAIR using a long TR (20,000 ms) and 4-h-delay enhanced CFA (120°) 3D-FLAIR (TR 16,000 ms). Image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of them were compared. Agreement in the evaluation of the EH degree between them was analyzed. RESULTS: In the phantom study, CNRs between perilymphatic and endolymphatic samples of VFA 3D-FLAIR (TR 10,000 ms) and CFA 3D-FLAIR (TR 10,000, 16,000, and 20,000 ms) were 6.66 ± 1.30, 17.90 ± 2.76, 23.87 ± 3.09, and 28.22 ± 3.15 (p < 0.001). In patient study, average score (3.65 ± 0.48 vs. 4.19 ± 0.40), SNR (34.56 ± 9.80 vs. 51.40 ± 11.27), and CNR (30.66 ± 10.55 vs. 45.08 ± 12.27) of unenhanced 3D-FLAIR were lower than enhanced 3D-FLAIR (p < 0.001). Evaluations of the two sequences showed excellent agreement in the cochlear and vestibule (Kappa value: 0.898 and 0.909). CONCLUSIONS: The CFA 3D-FLAIR sequence using a long TR could be used in unenhanced EH imaging with high accuracy. CLINICAL RELEVANCE STATEMENT: Unenhanced imaging of endolymphatic hydrops is valuable in the diagnosis and follow-up of patients, especially those who cannot receive contrast-enhanced MRI. KEY POINTS: Ion and protein concentration differences can be utilized in differentiating endolymph and perilymph on MRI. Endolymphatic and perilymphatic samples could be differentiated in vitro on this 3D-FLAIR sequence. This unenhanced 3D-FLAIR sequence is in excellent agreement with the enhanced constant flip angle 3D-FLAIR sequence.

2.
Magn Reson Imaging ; 109: 27-33, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38438094

RESUMEN

OBJECTIVE: The evaluate the feasibility of a novel deep learning-reconstructed ultra-fast respiratory-triggered T2WI sequence (DL-RT-T2WI) In liver imaging, compared with respiratory-triggered Arms-T2WI (Arms-RT-T2WI) and respiratory-triggered FSE-T2WI (FSE-RT-T2WI) sequences. METHODS: 71 patients with liver lesions underwent 3-T MRI and were prospectively enrolled. Two readers independently analyzed images acquired with DL-RT-T2WI, Arms-RT-T2WI, and FSE-RT-T2WI. The qualitative evaluation indicators, including overall image quality (OIQ), sharpness, noise, artifacts, lesion detectability (LC), lesion characterization (LD), cardiacmotion-related signal loss (CSL), and diagnostic confidence (DC), were evaluated in two readers, and further statistically compared using paired Wilcoxon rank-sum test among three sequences. RESULTS: 176 lesions were detected in DL-RT-T2W and Arms-RT-T2WI, and 175 were detected in FSE-RT-T2WI. The acquisition time of DL-RT-T2WI was improved by 4.8-7.9 folds compared to the other two sequences. The OIQ was scored highest for DL-RT-T2WI (R1, 4.61 ± 0.52 and R2, 4.62 ± 0.49), was significantly superior to Arms-RT-T2WI (R1, 4.30 ± 0.66 and R2, 4.34 ± 0.69) and FSE-RT-T2WI (R1, 3.65 ± 1.08 and R2, 3.75 ± 1.01). Artifacts and sharpness scored highest for DL-RT-T2WI, followed by Arms-RT-T2WI, and were lowest for FSE-RT-T2WI in both two readers. Noise and CSL for DL-RT-T2WI scored similar to Arms-RT-T2WI (P > 0.05) and were significantly superior to FSE-RT-T2WI (P < 0.001). Both LD and LC for DL-RT-T2WI were significantly superior to Arms-RT-T2WI and FSE-RT-T2WI in two readers (P < 0.001). DC for DL-RT-T2WI scored best, significantly superior to Arms-RT-T2WI (P < 0.010) and FSE-RT-T2WI (P < 0.001). CONCLUSIONS: The novel ultra-fast DL-RT-T2WI is feasible for liver imaging and lesion characterization and diagnosis, not only offers a significant improvement in acquisition time but also outperforms Arms-RT-T2WI and FSE-RT-T2WI concerning image quality and DC.


Asunto(s)
Aprendizaje Profundo , Neoplasias Hepáticas , Humanos , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Artefactos
3.
Foods ; 12(15)2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37569087

RESUMEN

In order to solve the problem of large image noise and unremarkable features caused by factors such as fluctuations in the power of a light source during the terahertz image acquisition of wheat, this paper proposes a THz image-denoising model called G-RRDB. Firstly, a module called Ghost-LKA is proposed by combining a large kernel convolutional attention mechanism module with a Ghost convolutional structure, which improves the characteristics of the network to acquire a global sensory field. Secondly, by integrating a spatial attention mechanism with channel attention, an attention module called DAB is proposed to enhance the network's attention to important features. Thirdly, the Ghost-LKA module and DAB module are combined with the baseline model, thus proposing the dense residual denoising network G-RRDB. Compared with traditional denoising networks, both the PSNR and SSIM are improved. The prediction accuracy of G-RRDB is verified through the classification of the VGG16 network, achieving a rate of 92.8%, which represents an improvement of 1.7% and 0.2% compared to the denoised images obtained from the baseline model and the combined baseline model with the DAB module, respectively. The experimental results demonstrate that G-RRDB, a THz image-denoising model based on dense residual structure for moldy wheat, exhibits excellent denoising performance.

4.
Acta Radiol ; 64(5): 1943-1949, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36423247

RESUMEN

BACKGROUND: Satisfactory magnetic resonance imaging (MRI) of those patients with involuntary head motion due to brain diseases is essential in avoiding missed diagnosis and guiding treatment. PURPOSE: To investigate the clinical feasibility of artificial intelligence-assisted compressed sensing single-shot fluid-attenuated inversion recovery (ACS-SS-FLAIR) in evaluating patients with involuntary head motion due to brain diseases, compared with the conventional T2-FLAIR with parallel imaging (PI-FLAIR). MATERIAL AND METHODS: A total of 33 uncooperative patients with brain disease were prospectively enrolled. Two readers independently reviewed images acquired with ACS-SS-FLAIR and PI-FLAIR at a 3.0-T MR scanner. In the aspects of qualitative evaluation of image quality, overall image quality and lesion conspicuity of ACS-SS-FLAIR and PI-FLAIR were assessed and then statistically compared by paired Wilcoxon rank-sum test. For quantitative evaluation, the relative contrast of lesion-to-cerebral parenchyma were calculated and compared. RESULTS: Overall image quality scores of ACS-SS-FLAIR evaluated by two readers were 2.94 ± 0.24 and 2.91 ± 0.29, respectively, both of which were significantly higher than that of PI-FLAIR, respectively (P < 0.001 and <0.001). Lesion conspicuity scores of were 2.74 ± 0.47 and 2.79 ± 0.44, both of which were significantly higher than that of PI-FLAIR, respectively (P < 0.001 and <0.001). In the quantitative evaluation for image quality, the relative contrast of lesion-to-cerebral parenchyma was 0.34 ± 0.09 in the ACS-SS-FLAIR sequence, significantly larger than that in the PI-FLAIR sequence (P = 0.001). CONCLUSION: The ACS-SS-FLAIR sequence is clinically feasible in the MRI workup of those patients with involuntary head motion due to brain diseases, showing shorter image acquisition time and better image quality compared with conventional PI-FLAIR.


Asunto(s)
Inteligencia Artificial , Encefalopatías , Humanos , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Encefalopatías/diagnóstico por imagen , Encefalopatías/patología , Movimiento (Física) , Encéfalo/diagnóstico por imagen , Encéfalo/patología
5.
Eur J Radiol ; 158: 110614, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36423365

RESUMEN

PURPOSE: To evaluate an optimized 3D-real IR sequence with a longer TR (16,000 ms) based on the modulated flip angle technique in refocused imaging with extended echo train (MATRIX) for the endolymphatic hydrops (EH) after intravenous (IV) single-dose gadolinium (Gd) administration, and compare it with a heavily T2-weighted 3D-FLAIR sequence with a constant flip angle. METHOD: The 3D-FLAIR and 3D-real IR sequences were performed in forty patients with definite Meniere's disease (MD) four hours after IV Gd administration. Image qualities of the two sequences were rated and compared. Contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs) of the two sequences were measured for quantitative comparison. EH was graded on the images of the two sequences by two radiologists. RESULTS: Scores and CNRs of the 3D-real IR were significantly higher than those of the 3D-FLAIR (P < 0.05). SNRs of the two sequences were comparable between the two groups. 3D-real IR had a higher inter- and intra-observer reliability for the grading of cochlear and vestibular EH than 3D-FLAIR. Using 3D-real IR sequence, the detection rate of EH of the whole labyrinth was higher than using 3D-FLAIR (86.6 % vs 73.3 %, p = 0.031). In the patients with unilateral MD, SNRs in the affected sides were significantly higher than the unaffected sides (P < 0.05). CONCLUSIONS: The optimized 3D-real IR with a longer TR is a robust sequence with an improved depiction of EH after IV administration of single-dose Gd. Compared with 3D-FLAIR, it may allow a more precise evaluation and grading of EH.


Asunto(s)
Hidropesía Endolinfática , Enfermedad de Meniere , Humanos , Reproducibilidad de los Resultados , Medios de Contraste , Hidropesía Endolinfática/diagnóstico por imagen , Enfermedad de Meniere/diagnóstico por imagen , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Gadolinio , Imagenología Tridimensional/métodos
6.
Eur J Radiol ; 139: 109729, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33905976

RESUMEN

PURPOSE: To investigate whether an isotropic T1-weighted gradient echo (T1-GRE) sequence using a compressed sensing (CS) technique during liver magnetic resonance imaging (MRI) can improve the image quality compared to that using a standard parallel imaging (PI) technique in patients with hepatocellular carcinoma (HCC). METHODS: Forty-nine patients with single pathologically confirmed HCC were included in the prospective study, who underwent a 3.0 T MRI including the two T1-GRE sequences (CS and PI). Qualitative analysis including the relative contrast (RC) of liver-to-lesion, liver-to-portal vein and liver-to-hepatic vein on pre-contrast and postcontrast (delayed phase) images were calculated. Respiratory motion artifact, gastrointestinal motion artifact and overall image quality were scored by using a 4-point scale. RESULTS: RC of liver-to-lesion, liver-to-portal vein and liver-to-hepatic vein measured on both pre-contrast and postcontrast phase images were significantly higher for CS than for PI. The scores of overall image quality was comparable between PI and CS (3.98 ±â€¯0.10vs 3.96 ±â€¯0.13, P = 0.083 for pre-contrast; 3.96 ±â€¯0.16 vs 3.93 ±â€¯0.17, P = 0.132 for postcontrast, respectively). The scores of gastrointestinal motion artifact was significantly higher for PI than for CS (3.92 ±â€¯0.21 vs 3.69 ±â€¯0.33 for pre-contrast; 3.86 ±â€¯0.21 vs 3.59 ±â€¯0.30 for postcontrast, P < 0.001 for both). The scores of respiratory motion artifact was significantly higher for PI only in pre-contrast sequence (3.97±0.11 vs 3.89 ±â€¯0.22, P = 0.002 for pre-contrast; 3.95 ±â€¯0.18 vs 3.90 ±â€¯0.22, P = 0.083 for postcontrast, respectively). CONCLUSIONS: Compared to the standard PI sequence, the CS technique can provide greater contrast in displaying HCCs and hepatic vessels in MRI without compromise of overall image quality.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Artefactos , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Estudios de Factibilidad , Humanos , Aumento de la Imagen , Imagenología Tridimensional , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA