1.
Invest Radiol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38949016

RESUMEN

OBJECTIVES: To evaluate the detectability of non-contrast-enhanced and contrast-enhanced spiral breast computed tomography ([non]-CE-SBCT) compared with mammography. Secondary objectives are to determine detectability depending on breast density and to evaluate appearance of breast malignancies according to BI-RADS descriptors. METHODS: This retrospective institutional review board-approved study included 90 women with 105 biopsy-proven malignant breast lesions. Breast density, BI-RADS descriptors, and detectability were evaluated by 2 independent readers. Diagnostic confidence was rated on a 4-point Likert scale. RESULTS: For readers 1 and 2, detectability was 83.8% and 80.0% for mammography, 99.1% and 99.1% for CE-SBCT ( P < 0.05), and 66.7% and 61.9% for non-CE-SBCT ( P < 0.05). With both readers, detectability in CE-SBCT was high for density A/B/C/D (both 100%/100%/100%/87.5%). Detectability of readers declined with increasing density for mammography (density A = 100%, B = 89.1% and 95.1%, C = 73.1%, D = 50.0% and 71.4%; P < 0.05) and for non-CE-SBCT (density A = 87.5% and 90.7%, B = 65.5% and 69.1%, C = 54.8% and 60.0%, D = 37.5%; P < 0.05). Mass lesions were detected with CT as often as with mammography, whereas architectural distortions and microcalcifications were detected less often with SBCT. Diagnostic confidence was very high or high in 97.2% for CE-SBCT, in 74.1% for non-CE-SBCT, and in 81.4% for mammography. CONCLUSIONS: Detectability and diagnostic confidence were very high in CE-SBCT, regardless of breast density. The detectability of non-CE-SBCT was lower than that of mammography and declined with increasing breast density.

2.
Diagnostics (Basel) ; 14(13)2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-39001317

RESUMEN

Diffusion-weighted imaging (DWI) combined with radiomics can aid in the differentiation of breast lesions. Segmentation characteristics, however, might influence radiomic features. To evaluate feature stability, we implemented a standardized pipeline featuring shifts and shape variations of the underlying segmentations. A total of 103 patients were retrospectively included in this IRB-approved study after multiparametric diagnostic breast 3T MRI with a spin-echo diffusion-weighted sequence with echoplanar readout (b-values: 50, 750 and 1500 s/mm2). Lesion segmentations underwent shifts and shape variations, with >100 radiomic features extracted from apparent diffusion coefficient (ADC) maps for each variation. These features were then compared and ranked based on their stability, measured by the Overall Concordance Correlation Coefficient (OCCC) and Dynamic Range (DR). Results showed variation in feature robustness to segmentation changes. The most stable features, excluding shape-related features, were FO (Mean, Median, RootMeanSquared), GLDM (DependenceNonUniformity), GLRLM (RunLengthNonUniformity), and GLSZM (SizeZoneNonUniformity), which all had OCCC and DR > 0.95 for both shifting and resizing the segmentation. Perimeter, MajorAxisLength, MaximumDiameter, PixelSurface, MeshSurface, and MinorAxisLength were the most stable features in the Shape category with OCCC and DR > 0.95 for resizing. Considering the variability in radiomic feature stability against segmentation variations is relevant when interpreting radiomic analysis of breast DWI data.

3.
Invest Radiol ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38923436

RESUMEN

OBJECTIVES: Clinical experience regarding the use of dedicated photon-counting breast CT (PC-BCT) for diagnosis of breast microcalcifications is scarce. This study systematically compares the detection and classification of breast microcalcifications using a dedicated breast photon-counting CT, especially designed for examining the breast, in comparison with digital breast tomosynthesis (DBT). MATERIALS AND METHODS: This is a prospective intraindividual study on women with DBT screening-detected BI-RADS-4/-5 microcalcifications who underwent PC-BCT before biopsy. PC-BCT images were reconstructed with a noninterpolated spatial resolution of 0.15 × 0.15 × 0.15 mm (reconstruction mode 1 [RM-1]) and with 0.3 × 0.3 × 0.3 mm (reconstruction mode 2 [RM-2]), plus thin-slab maximum intensity projection (MIP) reconstructions. Two radiologists independently rated the detection of microcalcifications in direct comparison with DBT on a 5-point scale. The distribution and morphology of microcalcifications were then rated according to BI-RADS. The size of the smallest discernible microcalcification particle was measured. For PC-BCT, the average glandular dose was determined by Monte Carlo simulations; for DBT, the information provided by the DBT system was used. RESULTS: Between September 2022 and July 2023, 22 participants (mean age, 61; range, 42-85 years) with microcalcifications (16 malignant; 6 benign) were included. In 2/22 with microcalcifications in the posterior region, microcalcifications were not detectable on PC-BCT, likely because they were not included in the PC-BCT volume. In the remaining 20 participants, microcalcifications were detectable. With high between-reader agreement (κ > 0.8), conspicuity of microcalcifications was rated similar for DBT and MIPs of RM-1 (mean, 4.83 ± 0.38 vs 4.86 ± 0.35) (P = 0.66), but was significantly lower (P < 0.05) for the remaining PC-BCT reconstructions: 2.11 ± 0.92 (RM-2), 2.64 ± 0.80 (MIPs of RM-2), and 3.50 ± 1.23 (RM-1). Identical distribution qualifiers were assigned for PC-BCT and DBT in 18/20 participants, with excellent agreement (κ = 0.91), whereas identical morphologic qualifiers were assigned in only 5/20, with poor agreement (κ = 0.44). The median size of smallest discernible microcalcification particle was 0.2 versus 0.6 versus 1.1 mm in DBT versus RM-1 versus RM-2 (P < 0.001), likely due to blooming effects. Average glandular dose was 7.04 mGy (PC-BCT) versus 6.88 mGy (DBT) (P = 0.67). CONCLUSIONS: PC-BCT allows reliable detection of in-breast microcalcifications as long as they are not located in the posterior part of the breast and allows assessment of their distribution, but not of their individual morphology.

4.
Rofo ; 2024 Jun 21.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-38906159

RESUMEN

Axillary lymphadenopathy (LA) after COVID-19 vaccination is now known to be a common side effect. In these cases, malignancy cannot always be excluded on the basis of morphological imaging criteria.Narrative review for decision-making regarding control and follow-up intervals for axillary LA according to currently published research. This article provides a practical overview of the management of vaccine-associated LA using image examples and a flowchart and provides recommendations for follow-up intervals. A particular focus is on patients presenting for diagnostic breast imaging. The diagnostic criteria for pathological lymph nodes (LN) are explained.Axillary LA is a common adverse effect after COVID-19 vaccination (0.3-53%). The average duration of LA is more than 100 days. LA is also known to occur after other vaccinations, such as the seasonal influenza vaccine. Systematic studies on this topic are missing. Other causes of LA after vaccination (infections, autoimmune diseases, malignancies) should be considered for the differential diagnosis. If the LA persists for more than 3 months after COVID-19 vaccination, a primarily sonographic follow-up examination is recommended after another 3 months. A minimally invasive biopsy of the LA is recommended if a clinically suspicious LN persists or progresses. In the case of histologically confirmed breast cancer, a core biopsy without a follow-up interval is recommended regardless of the vaccination, as treatment appropriate to the stage should not be influenced by follow-up intervals. For follow-up after breast cancer, the procedure depends on the duration of the LA and the woman's individual risk of recurrence.Vaccination history should be well documented and taken into account when evaluating suspicious LN. Biopsy of abnormal, persistent, or progressive LNs is recommended. Preoperative staging of breast cancer should not be delayed by follow-up. The risk of false-positive findings is accepted, and the suspicious LNs are histologically examined in a minimally invasive procedure. · The vaccination history must be documented (vaccine, date, place of application).. · If axillary LA persists for more than 3 months after vaccination, a sonographic follow-up examination is recommended after 3 months.. · Enlarged LNs that are persistent, progressive in size, or are suspicious on control sonography should be biopsied.. · Suspicious LNs should be clarified before starting oncological therapy, irrespective of the vaccination status, according to the guidelines and without delaying therapy.. · Wilpert C, Wenkel E, Baltzer PA et al. Vaccine-associated axillary lymphadenopathy with a focus on COVID-19 vaccines. Fortschr Röntgenstr 2024; DOI 10.1055/a-2328-7536.

5.
Diagnostics (Basel) ; 14(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38732348

RESUMEN

Several breast pathologies can affect the skin, and clinical pathways might differ significantly depending on the underlying diagnosis. This study investigates the feasibility of using diffusion-weighted imaging (DWI) to differentiate skin pathologies in breast MRIs. This retrospective study included 88 female patients who underwent diagnostic breast MRI (1.5 or 3T), including DWI. Skin areas were manually segmented, and the apparent diffusion coefficients (ADCs) were compared between different pathologies: inflammatory breast cancer (IBC; n = 5), benign skin inflammation (BSI; n = 11), Paget's disease (PD; n = 3), and skin-involved breast cancer (SIBC; n = 11). Fifty-eight women had healthy skin (H; n = 58). The SIBC group had a significantly lower mean ADC than the BSI and IBC groups. These differences persisted for the first-order features of the ADC (mean, median, maximum, and minimum) only between the SIBC and BSI groups. The mean ADC did not differ significantly between the BSI and IBC groups. Quantitative DWI assessments demonstrated differences between various skin-affecting pathologies, but did not distinguish clearly between all of them. More extensive studies are needed to assess the utility of quantitative DWI in supplementing the diagnostic assessment of skin pathologies in breast imaging.

6.
Sci Rep ; 14(1): 6391, 2024 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-38493266

RESUMEN

The purpose of this feasibility study is to investigate if latent diffusion models (LDMs) are capable to generate contrast enhanced (CE) MRI-derived subtraction maximum intensity projections (MIPs) of the breast, which are conditioned by lesions. We trained an LDM with n = 2832 CE-MIPs of breast MRI examinations of n = 1966 patients (median age: 50 years) acquired between the years 2015 and 2020. The LDM was subsequently conditioned with n = 756 segmented lesions from n = 407 examinations, indicating their location and BI-RADS scores. By applying the LDM, synthetic images were generated from the segmentations of an independent validation dataset. Lesions, anatomical correctness, and realistic impression of synthetic and real MIP images were further assessed in a multi-rater study with five independent raters, each evaluating n = 204 MIPs (50% real/50% synthetic images). The detection of synthetic MIPs by the raters was akin to random guessing with an AUC of 0.58. Interrater reliability of the lesion assessment was high both for real (Kendall's W = 0.77) and synthetic images (W = 0.85). A higher AUC was observed for the detection of suspicious lesions (BI-RADS ≥ 4) in synthetic MIPs (0.88 vs. 0.77; p = 0.051). Our results show that LDMs can generate lesion-conditioned MRI-derived CE subtraction MIPs of the breast, however, they also indicate that the LDM tended to generate rather typical or 'textbook representations' of lesions.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Humanos , Persona de Mediana Edad , Femenino , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Mama/patología , Examen Físico , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Retrospectivos
7.
Rofo ; 196(3): 228-230, 2024 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-38382500
8.
Eur J Radiol ; 173: 111352, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38330534

RESUMEN

PURPOSE: Broader clinical adoption of breast magnetic resonance imaging (MRI) faces challenges such as limited availability and high procedural costs. Low-field technology has shown promise in addressing these challenges. We report our initial experience using a next-generation scanner for low-field breast MRI at 0.55T. METHODS: This initial cases series was part of an institutional review board-approved prospective study using a 0.55T scanner (MAGNETOM Free.Max, Siemens Healthcare, Erlangen/Germany: height < 2 m, weight < 3.2 tons, no quench pipe) equipped with a seven-channel breast coil (Noras, Höchberg/Germany). A multiparametric breast MRI protocol consisting of dynamic T1-weighted, T2-weighted, and diffusion-weighted sequences was optimized for 0.55T. Two radiologists with 12 and 20 years of experience in breast MRI evaluated the examinations. RESULTS: Twelve participants (mean age: 55.3 years, range: 36-78 years) were examined. The image quality was diagnostic in all examinations and not impaired by relevant artifacts. Typical imaging phenotypes were visualized. The scan time for a complete, non-abbreviated breast MRI protocol ranged from 10:30 to 18:40 min. CONCLUSION: This initial case series suggests that low-field breast MRI is feasible at diagnostic image quality within an acceptable examination time.


Asunto(s)
Imagen por Resonancia Magnética , Imágenes de Resonancia Magnética Multiparamétrica , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Mama/patología
9.
Rofo ; 196(9): 939-944, 2024 Sep.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-38237631

RESUMEN

· Breast MRI is an essential part of breast imaging. · The recommendations for performing breast MRI have been updated. · A table provides a compact and quick overview. More detailed comments supplement the table.. · The "classic" breast MRI can be performed based on the recommendations. Tips for special clinical questions, such as implant rupture, mammary duct pathology or local lymph node status, are included.. CITATION FORMAT: · Wenkel E, Wunderlich P, Fallenberg E et al. Aktualisierung der Empfehlungen der AG Mammadiagnostik der Deutschen Röntgengesellschaft zur Durchführung der Mamma-MRT. Fortschr Röntgenstr 2024; 196: 939 - 944.


Asunto(s)
Neoplasias de la Mama , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/normas , Imagen por Resonancia Magnética/métodos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Alemania , Sociedades Médicas , Implantes de Mama , Radiología/normas , Mama/diagnóstico por imagen , Enfermedades de la Mama/diagnóstico por imagen
10.
Eur Radiol ; 34(7): 4752-4763, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38099964

RESUMEN

OBJECTIVES: To evaluate whether artifacts on contrast-enhanced (CE) breast MRI maximum intensity projections (MIPs) might already be forecast before gadolinium-based contrast agent (GBCA) administration during an ongoing examination by analyzing the unenhanced T1-weighted images acquired before the GBCA injection. MATERIALS AND METHODS: This IRB-approved retrospective analysis consisted of n = 2884 breast CE MRI examinations after intravenous administration of GBCA, acquired with n = 4 different MRI devices at different field strengths (1.5 T/3 T) during clinical routine. CE-derived subtraction MIPs were used to conduct a multi-class multi-reader evaluation of the presence and severity of artifacts with three independent readers. An ensemble classifier (EC) of five DenseNet models was used to predict artifacts for the post-contrast subtraction MIPs, giving as the input source only the pre-contrast T1-weighted sequence. Thus, the acquisition directly preceded the GBCA injection. The area under ROC (AuROC) and diagnostics accuracy scores were used to assess the performance of the neural network in an independent holdout test set (n = 285). RESULTS: After majority voting, potentially significant artifacts were detected in 53.6% (n = 1521) of all breast MRI examinations (age 49.6 ± 12.6 years). In the holdout test set (mean age 49.7 ± 11.8 years), at a specificity level of 89%, the EC could forecast around one-third of artifacts (sensitivity 31%) before GBCA administration, with an AuROC = 0.66. CONCLUSION: This study demonstrates the capability of a neural network to forecast the occurrence of artifacts on CE subtraction data before the GBCA administration. If confirmed in larger studies, this might enable a workflow-blended approach to prevent breast MRI artifacts by implementing in-scan personalized predictive algorithms. CLINICAL RELEVANCE STATEMENT: Some artifacts in contrast-enhanced breast MRI maximum intensity projections might be predictable before gadolinium-based contrast agent injection using a neural network. KEY POINTS: • Potentially significant artifacts can be observed in a relevant proportion of breast MRI subtraction sequences after gadolinium-based contrast agent administration (GBCA). • Forecasting the occurrence of such artifacts in subtraction maximum intensity projections before GBCA administration for individual patients was feasible at 89% specificity, which allowed correctly predicting one in three future artifacts. • Further research is necessary to investigate the clinical value of such smart personalized imaging approaches.


Asunto(s)
Artefactos , Neoplasias de la Mama , Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Medios de Contraste/administración & dosificación , Femenino , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Neoplasias de la Mama/diagnóstico por imagen , Adulto , Mama/diagnóstico por imagen , Gadolinio/administración & dosificación , Anciano , Aumento de la Imagen/métodos
12.
Eur Radiol ; 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-37999727

RESUMEN

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

13.
Diagnostics (Basel) ; 13(19)2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37835805

RESUMEN

BACKGROUND: Radiopaque breast markers cause artifacts in dedicated spiral breast-computed tomography (SBCT). This study investigates the extent of artifacts in different marker types and the feasibility of reducing artifacts through a metal artifact reduction (MAR) algorithm. METHODS: The pilot study included 18 women who underwent contrast-enhanced SBCT. In total, 20 markers of 4 different types were analyzed for artifacts. The extent of artifacts with and without MAR was measured via the consensus of two readers. Image noise was quantitatively evaluated, and the effect of MAR on the detectability of breast lesions was evaluated on a 3-point Likert scale. RESULTS: Breast markers caused significant artifacts that impaired image quality and the detectability of lesions. MAR decreased artifact size in all analyzed cases, even in cases with multiple markers in a single slice. The median length of in-plain artifacts significantly decreased from 31 mm (range 11-51 mm) in uncorrected to 2 mm (range 1-5 mm) in corrected images (p ≤ 0.05). Artifact size was dependent on marker size. Image noise in slices affected by artifacts was significantly lower in corrected (13.6 ± 2.2 HU) than in uncorrected images (19.2 ± 6.8 HU, p ≤ 0.05). MAR improved the detectability of lesions affected by artifacts in 5 out of 11 cases. CONCLUSION: MAR is feasible in SBCT and improves the image quality and detectability of lesions.

14.
Radiologie (Heidelb) ; 63(12): 916-924, 2023 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-37889284

RESUMEN

BACKGROUND: Contrast-enhanced mammography (CEM) is an imaging method that is able to improve visualization of intramammary tumors after peripheral venous administration of an iodine-containing contrast medium (ICM). OBJECTIVES AND METHODS: The current significance of CEM is discussed. RESULTS: Studies were able to show an advantage of CEM in the diagnosis of breast cancer compared to mammography, especially for women with dense breasts. Indications for CEM currently depend on the availability of magnetic resonance imaging (MRI). If MRI is available, CEM is indicated in those cases when MRI cannot be performed. Use of CEM for breast cancer screening is currently viewed critically. This view can change when results and updated assessments of large CEM studies in Europe and USA become available. Patients must be informed about the use of an ICM. As ICM administration for CEM is carried out in a similar manner to established imaging methods, the authors expect the use of ICM for CEM to be unproblematic as long as general contraindications are adhered to. CONCLUSIONS: In the future, CEM could have greater importance for the diagnosis of breast cancer, as this imaging method has diagnostic advantages compared to conventional mammography. A great advantage of CEM is its availability. For those who use breast MRI, CEM is helpful when MRI is not feasible due to contraindications or other reasons.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Mamografía/métodos , Mama/diagnóstico por imagen , Mama/patología , Medios de Contraste , Predicción
15.
Acta Radiol ; 64(11): 2881-2890, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37682521

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) provides high diagnostic sensitivity for breast cancer. However, MRI artifacts may impede the diagnostic assessment. This is particularly important when evaluating maximum intensity projections (MIPs), such as in abbreviated MRI (AB-MRI) protocols, because high image quality is desired as a result of fewer sequences being available to compensate for problems. PURPOSE: To describe the prevalence of artifacts on dynamic contrast enhanced (DCE) MRI-derived MIPs and to investigate potentially associated attributes. MATERIAL AND METHODS: For this institutional review board approved retrospective analysis, MIPs were generated from subtraction series and cropped to represent the left and right breasts as regions of interest. These images were labeled by three independent raters regarding the presence of MRI artifacts. MRI artifact prevalence and associations with patient characteristics and technical attributes were analyzed using descriptive statistics and generalized linear models (GLMMs). RESULTS: The study included 2524 examinations from 1794 patients (median age 50 years), performed on 1.5 and 3.0 Tesla MRI systems. Overall inter-rater agreement was kappa = 0.54. Prevalence of significant unilateral artifacts was 29.2% (736/2524), whereas bilateral artifacts were present in 37.8% (953/2524) of all examinations. According to the GLMM, artifacts were significantly positive associated with age (odds ratio [OR] = 1.52) and magnetic field strength (OR = 1.55), whereas a negative effect could be shown for body mass index (OR = 0.95). CONCLUSION: MRI artifacts on DCE subtraction MIPs of the breast, as used in AB-MRI, are a relevant topic. Our results show that, besides the magnetic field strength, further associated attributes are patient age and body mass index, which can provide possible targets for artifact reduction.


Asunto(s)
Artefactos , Neoplasias de la Mama , Humanos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Prevalencia , Mama/diagnóstico por imagen , Mama/patología , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/patología , Medios de Contraste
16.
Sci Rep ; 13(1): 10549, 2023 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-37386021

RESUMEN

The objective of this IRB approved retrospective study was to apply deep learning to identify magnetic resonance imaging (MRI) artifacts on maximum intensity projections (MIP) of the breast, which were derived from diffusion weighted imaging (DWI) protocols. The dataset consisted of 1309 clinically indicated breast MRI examinations of 1158 individuals (median age [IQR]: 50 years [16.75 years]) acquired between March 2017 and June 2020, in which a DWI sequence with a high b-value equal to 1500 s/mm2 was acquired. From these, 2D MIP images were computed and the left and right breast were cropped out as regions of interest (ROI). The presence of MRI image artifacts on the ROIs was rated by three independent observers. Artifact prevalence in the dataset was 37% (961 out of 2618 images). A DenseNet was trained with a fivefold cross-validation to identify artifacts on these images. In an independent holdout test dataset (n = 350 images) artifacts were detected by the neural network with an area under the precision-recall curve of 0.921 and a positive predictive value of 0.981. Our results show that a deep learning algorithm is capable to identify MRI artifacts in breast DWI-derived MIPs, which could help to improve quality assurance approaches for DWI sequences of breast examinations in the future.


Asunto(s)
Aprendizaje Profundo , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Imagen de Difusión por Resonancia Magnética , Mama/diagnóstico por imagen , Algoritmos
17.
Rofo ; 195(8): 699-706, 2023 08.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37348527

RESUMEN

PURPOSE: Breast imaging represents an integral part of radiology and is subject to strict quality controls. Regarding this, precise diagnostics including multimodal assessment by mammography, sonography, and MRI, including image-guided biopsy and localization procedures, is often decisive and must be performed by experts with profound knowledge and skills in all of these procedures.However, due to numerous restructurings, breast imaging has been shifted more and more towards large, specialized centers, resulting in less patient exposition and training opportunities for radiologists in smaller sites. The following whitepaper summarizes the current circumstances and discusses opinions of the participating societies. MATERIALS: Under the leadership of the German Roentgen Society (DRG) and with the participation of the DRG's AG Mammadiagnostik, the CAFRAD (Chefarztforum Radiologie), the KLR (Konferenz der Lehrstuhlinhaber für Radiologie e. V.), the DRG's Forum Junge Radiologie (FJR) and the Berufsverband der Deutschen Radiologen e. V. (BDR), possible solutions were discussed and consented for a structured training in breast radiology in the future. RESULTS: In addition to the teaching provided at the primary workplace, qualified training should be ensured through flexible, multi-institutional, interdisciplinary, and cross-sectoral collaboration. Furthermore, the integration of online case collections and close cooperation with certified breast cancer centers and mammography screening units is recommended. It is indispensible that online courses and case collections adhere to the standards of the national societies and include a maximum of one third of the required cases. CONCLUSION: In order to provide training in breast radiology at a high professional level, a paradigm shift with closer cooperation of all participants is necessary. This includes close collaboration of the breast imaging societies with the federal medical associations to establish new teaching concepts like e-learning in the training schedule of radiologists. KEY POINTS: · Breast diagnostics is an integral part of radiology training.. · Due to recent restructurings, smaller training centers have difficulties in meeting the case numbers demanded by the Specialist Training Regulations (WBO). Improved integration of the new structures and their adaptation to the needs of education are necessary to guarantee standardized high-quality training of young radiologists.. · The integration of certified case collections enables quality-assured training, even across regions in online-based formats. In accordance with the "blended learning principle", up to one-third of the required number of patient studies can be substituted with cases from a certified case collection.. · Legally secured short- and medium-term internships may complement training in radiology.. CITATION FORMAT: · Sauer ST, Bley TA, Wenkel E et al. Whitepaper: Training in Diagnostic and Interventional Breast Radiology. Fortschr Röntgenstr 2023; 195: 699 - 706.


Asunto(s)
Curriculum , Radiología Intervencionista , Humanos , Aprendizaje , Mamografía , Ultrasonografía
18.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37138190

RESUMEN

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mastectomía , Mastectomía Segmentaria , Mama , Imagen por Resonancia Magnética , Cuidados Preoperatorios
20.
Diagnostics (Basel) ; 13(6)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36980504

RESUMEN

BACKGROUND: In the German Mammography Screening Program, 62% of ductal carcinoma in situ (DCIS) and 38% of invasive breast cancers are associated with microcalcifications (MCs). Vacuum-assisted stereotactic breast biopsies are necessary to distinguish precancerous lesions from benign calcifications because mammographic discrimination is not possible. The aim of this study was to investigate if breast magnetic resonance imaging (MRM) could assist the evaluation of MCs and thus help reduce biopsy rates. METHODS: In this IRB-approved study, 58 women (mean age 58 +/- 24 years) with 59 suspicious MC clusters in the MG were eligible for this prospective single-center trial. Additional breast magnetic resonance imaging (MRI) was conducted before biopsy. RESULTS: The breast MRI showed a sensitivity of 86%, a specificity of 84%, a positive predictive value (PPV) of 75% and a negative predictive value (NPV) of 91% for the differentiation between benign and malignant in these 59 MCs found with MG. Breast MRI in addition to MG could increase the PPV from 36% to 75% compared to MG alone. The MRI examination led to nine additional suspicious classified lesions in the study cohort. A total of 55% (5/9) of them turned out to be malignant. A total of 32 of 59 (54 %) women with suspicious MCs and benign histology were classified as non-suspicious by MRI. CONCLUSION: An additionally performed breast MRI could have increased the diagnostic reliability in the assessment of MCs. Further, in our small cohort, a considerable number of malignant lesions without mammographically visible MCs were revealed.