Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Biol Chem ; 286(14): 12407-16, 2011 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-21266572

RESUMEN

Phospholipase C (PLC) enzymes are an important family of regulatory proteins involved in numerous cellular functions, primarily through hydrolysis of the polar head group from inositol-containing membrane phospholipids. U73122 (1-(6-((17ß-3-methoxyestra-1,3,5(10)-trien-17-yl)amino)hexyl)-1H-pyrrole-2,5-dione), one of only a few small molecules reported to inhibit the activity of these enzymes, has been broadly applied as a pharmacological tool to implicate PLCs in diverse experimental phenotypes. The purpose of this study was to develop a better understanding of molecular interactions between U73122 and PLCs. Hence, the effects of U73122 on human PLCß3 (hPLCß3) were evaluated in a cell-free micellar system. Surprisingly, U73122 increased the activity of hPLCß3 in a concentration- and time-dependent manner; up to an 8-fold increase in enzyme activity was observed with an EC50=13.6±5 µm. Activation of hPLCß3 by U73122 required covalent modification of cysteines as evidenced by the observation that enzyme activation was attenuated by thiol-containing nucleophiles, l-cysteine and glutathione. Mass spectrometric analysis confirmed covalent reaction with U73122 at eight cysteines, although maximum activation was achieved without complete alkylation; the modified residues were identified by LC/MS/MS peptide sequencing. Interestingly, U73122 (10 µm) also activated hPLCγ1 (>10-fold) and hPLCß2 (∼2-fold); PLCδ1 was neither activated nor inhibited. Therefore, in contrast to its reported inhibitory potential, U73122 failed to inhibit several purified PLCs. Most of these PLCs were directly activated by U73122, and a simple mechanism for the activation is proposed. These results strongly suggest a need to re-evaluate the use of U73122 as a general inhibitor of PLC isozymes.


Asunto(s)
Estrenos/farmacología , Inhibidores de Fosfodiesterasa/farmacología , Pirrolidinonas/farmacología , Fosfolipasas de Tipo C/metabolismo , Secuencia de Aminoácidos , Activación Enzimática/efectos de los fármacos , Estrenos/química , Humanos , Datos de Secuencia Molecular , Inhibidores de Fosfodiesterasa/química , Pirrolidinonas/química , Fosfolipasas de Tipo C/química
2.
Proc Natl Acad Sci U S A ; 105(8): 2773-8, 2008 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-18287036

RESUMEN

Analysis of the x-ray crystal structure of mono-substituted acetylenic thienopyrimidine 6 complexed with the ErbB family enzyme ErbB-4 revealed a covalent bond between the terminal carbon of the acetylene moiety and the sulfhydryl group of Cys-803 at the solvent interface. The identification of this covalent adduct suggested that acetylenic thienopyrimidine 6 and related analogs might also be capable of forming an analogous covalent adduct with EGFR, which has a conserved cysteine (797) near the ATP binding pocket. To test this hypothesis, we treated a truncated, catalytically competent form of EGFR (678-1020) with a structurally related propargylic amine (8). An investigation of the resulting complex by mass spectrometry revealed the formation of a covalent complex of thienopyrimidine 8 with Cys-797 of EGFR. This finding enabled us to readily assess the irreversibility of various inhibitors and also facilitated a structure-activity relationship understanding of the covalent modifying potential and biological activity of a series of acetylenic thienopyrimidine compounds with potent antitumor activity. Several ErbB family enzyme and cell potent 6-ethynyl thienopyrimidine kinase inhibitors were found to form covalent adducts with EGFR.


Asunto(s)
Alquinos/metabolismo , Compuestos de Anilina/metabolismo , Receptores ErbB/metabolismo , Modelos Moleculares , Pirimidinas/metabolismo , Animales , Proliferación Celular/efectos de los fármacos , Cristalografía por Rayos X , Relación Dosis-Respuesta a Droga , Femenino , Isatina/análogos & derivados , Isatina/metabolismo , Espectrometría de Masas , Ratones , Ratones SCID , Estructura Molecular , Pirimidinas/toxicidad , Proteínas Tirosina Quinasas Receptoras/metabolismo , Relación Estructura-Actividad , Ensayos Antitumor por Modelo de Xenoinjerto
3.
J Mass Spectrom ; 42(2): 139-49, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17221927

RESUMEN

Characterization of recombinant protein purification fractions and final products by liquid chromatography-mass spectrometry (LC/MS) are requested more frequently each year. A protein open-access (OA) LC/MS system was developed in our laboratory to meet this demand. This paper compares the system that we originally implemented in our facilities in 2003 to the one now in use, and discusses, in more detail, recent enhancements that have improved its robustness, reliability, and data reporting capabilities. The system utilizes instruments equipped with reversed-phase chromatography and an orthogonal accelerated time-of-flight mass spectrometer fitted with an electrospray source. Sample analysis requests are accomplished using a simple form on a web-enabled laboratory information management system (LIMS). This distributed form is accessible from any intranet-connected company desktop computer. Automated data acquisition and processing are performed using a combination of in-house (OA-Self Service, OA-Monitor, and OA-Analysis Engine) and vendor-supplied programs (AutoLynx, and OpenLynx) located on acquisition computers and off-line processing workstations. Analysis results are then reported via the same web-based LIMS. Also presented are solutions to problems not addressed on commercially available, small-molecule OA-LC/MS systems. These include automated transforming of mass-to-charge (m/z) spectra to mass spectra and automated data interpretation that considers minor variants to the protein sequence-such as common post-translational modifications (PTMs). Currently, our protein OA-LC/MS platform runs on five LC/MS instruments located in three separate GlaxoSmithKline R&D sites in the US and UK. To date, more than 8000 protein OA-LC/MS samples have been analyzed. With these user friendly and highly automated OA systems in place, mass spectrometry plays a key role in assessing the quality of recombinant proteins, either produced at our facilities or bought from external sources, without dedicating extensive amounts of analyst resource.


Asunto(s)
Anhidrasas Carbónicas/química , Caseínas/química , Procesamiento Automatizado de Datos , Gestión de la Información , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Bovinos , Cromatografía Líquida de Alta Presión , Mapeo Peptídico , Proteínas Recombinantes/química , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray/instrumentación
4.
Rapid Commun Mass Spectrom ; 19(2): 241-9, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15609371

RESUMEN

Each year increasing numbers of proteins are submitted for routine characterization by liquid chromatography/mass spectrometry (LC/MS). This paper reports a solution that transforms routine LC/MS analysis of proteins into a fully automated process that significantly reduces analyst intervention. The solution developed, protein open-access (OA) LC/MS, consists of web-enabled sample submission and registration, automated data processing, data interpretation, and report generation. Sample submissions and results are recorded in a LIMS that utilizes an Oracle database. The protein sequence is captured during the sample submission process, stored in the database, and utilized to determine the theoretical protein molecular weight. This calculated mass is used to set the parameters for transformation of the mass-to-charge spectra to the mass domain and evaluate the presence or absence of the desired protein. Three protein OA-LC/MS instruments have been deployed in our facility to support protein characterization, purification, and modification efforts.


Asunto(s)
Mioglobina/análisis , Mapeo Peptídico/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Cromatografía Líquida de Alta Presión , Bases de Datos de Proteínas , Humanos , Mioglobina/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...