Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
Diagnostics (Basel) ; 13(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36766647

RESUMEN

Urine sedimentation in the bladder can occur in various circumstances and can lead to urinary obstruction/stasis with associated pain. It is usually diagnosed with an ultrasound; however, CT is also used to assess the amount and to further check for urinary stones. Depending on the composition, urine sedimentation and stones can be treated medically by alkalinisation of the urine with potassium sodium hydrogen citrate in the case of uric acid-based sedimentation/stones. Due to technical developments and improved material differentiation and characterisation in CT imaging, dual-energy CT allows for differentiation of uric acid from calcium, which can be used for sedimentation/stone composition analysis. Subsequently, treatment decisions can be made based on the findings in dual-energy CT.

2.
Acad Radiol ; 30(10): 2110-2117, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36577605

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the bone mineral density (BMD) of the lumbar spine derived from dual-energy CT (DECT)-based volumetric material decomposition and its association with acute insufficiency fractures of the thoracolumbar spine. MATERIALS AND METHODS: L1 of 160 patients (77 men, 83 women; mean age 64.3 years, range, 22-94 years) who underwent third-generation dual-source DECT between January 2016 and December 2021 due to suspected insufficiency fractures was retrospectively analyzed. All depicted vertebrae were examined for signs of recent fractures. A dedicated DECT postprocessing software using material decomposition was applied for phantomless BMD assessment. Receiver-operating characteristic (ROC) analysis identified optimal BMD thresholds. Associations of BMD, sex, and age with the occurrence of insufficiency fractures were examined with logistic regression models. RESULTS: A DECT-derived BMD threshold of 120.40 mg/cm³ yielded 90.1% specificity and 59.32% sensitivity to differentiate patients with at least one insufficiency fracture from patients without fracture. No patient without fracture had a DECT-derived BMD below 85 mg/cm3. Lower DECT-derived bone mineral density was associated with an increased risk of insufficiency fractures (Odds ratio of 0.93, 95% CI, 0.91-0.96, p < 0.001). Overall ROC-derived AUC was 0.82 (p < 0.0001) for the differentiation of patients that sustained an insufficiency fracture from the control group. CONCLUSION: Dual-Energy CT-based BMD assessment can accurately differentiate patients with acute insufficiency fractures of the thoracolumbar spine from patients without fracture. This algorithm can be used for phantomless risk stratification of patients undergoing routine CT to sustain insufficiency fractures of the thoracolumbar spine The identified cut-off value of 120.4 mg/cm³ is in line with current American College of Radiology (ACR) recommendations to differentiate healthy individuals from those with reduced bone mineral density.


Asunto(s)
Fracturas por Estrés , Osteoporosis , Fracturas de la Columna Vertebral , Masculino , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Densidad Ósea , Estudios Retrospectivos , Prevalencia , Absorciometría de Fotón , Tomografía Computarizada por Rayos X , Vértebras Lumbares/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/epidemiología
3.
Diagnostics (Basel) ; 12(7)2022 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-35885585

RESUMEN

Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.

4.
Acad Radiol ; 29 Suppl 2: S108-S117, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33714665

RESUMEN

RATIONALE AND OBJECTIVES: Research on implementation of artificial intelligence (AI) in radiology workflows and its impact on reports remains scarce. In this study, we aim to assess if an AI platform would perform better than clinical radiology reports in evaluating noncontrast chest computed tomography (CT) scans. MATERIALS AND METHODS: Consecutive patients who had undergone noncontrast chest CT were retrospectively identified. The radiology reports were reviewed in a binary fashion for reporting of pulmonary lesions, pulmonary emphysema, aortic dilatation, coronary artery calcifications (CAC), and vertebral compression fractures (VCF). CT scans were then processed using an AI platform. The reports' findings and the AI results were subsequently compared to a consensus read by two board-certificated radiologists as reference. RESULTS: A total of 100 patients (mean age: 64.2 ± 14.8 years; 57% males) were included in this study. Aortic segmentation and calcium quantification failed to be processed by AI in 2 and 3 cases, respectively. AI showed superior diagnostic performance in identifying aortic dilatation (AI: sensitivity: 96.3%, specificity: 81.4%, AUC: 0.89) vs (Reports: sensitivity: 25.9%, specificity: 100%, AUC: 0.63), p <0.001; and CAC (AI: sensitivity: 89.8%, specificity: 100, AUC: 0.95) vs (Reports: sensitivity: 75.4%, specificity: 94.9%, AUC: 0.85), p = 0.005. Reports had better performance than AI in identifying pulmonary lesions (Reports: sensitivity: 97.6%, specificity: 100%, AUC: 0.99) vs (AI: sensitivity: 92.8%, specificity: 82.4%, AUC: 0.88), p = 0.024; and VCF (Reports: sensitivity:100%, specificity: 100%, AUC: 1.0) vs (AI: sensitivity: 100%, specificity: 63.7%, AUC: 0.82), p <0.001. A comparable diagnostic performance was noted in identifying pulmonary emphysema on AI (sensitivity: 80.6%, specificity: 66.7%. AUC: 0.74) and reports (sensitivity: 74.2%, specificity: 97.1%, AUC: 0.86), p = 0.064. CONCLUSION: Our results demonstrate that incorporating AI support platforms into radiology workflows can provide significant added value to clinical radiology reporting.


Asunto(s)
Fracturas por Compresión , Radiología , Fracturas de la Columna Vertebral , Anciano , Inteligencia Artificial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
5.
Acta Radiol ; 63(3): 328-335, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33657848

RESUMEN

BACKGROUND: High-resolution computed tomography (HRCT) is essential in narrowing the possible differential diagnoses of diffuse and interstitial lung diseases. PURPOSE: To investigate the value of a novel computer-based decision support system (CDSS) for facilitating diagnosis of diffuse lung diseases at HRCT. MATERIAL AND METHODS: A CDSS was developed that includes about 100 different illustrations of the most common HRCT signs and patterns and describes the corresponding pathologies in detail. The logical set-up of the software facilitates a structured evaluation. By selecting one or more CT patterns, the program generates a ranked list of the most likely differential diagnoses. Three independent and blinded radiology residents initially evaluated 40 cases with different lung diseases alone; after at least 12 weeks, observers re-evaluated all cases using the CDSS. RESULTS: In 40 patients, a total of 113 HRCT patterns were evaluated. The percentage of correctly classified patterns was higher with CDSS (96.8%) compared to assessment without CDSS (90.3%; P < 0.01). Moreover, the percentage of correct diagnosis (81.7% vs. 64.2%) and differential diagnoses (89.2% vs. 38.3%) were superior with CDSS compared to evaluation without CDSS (both P < 0.01). CONCLUSION: Addition of a CDSS using a structured approach providing explanations of typical HRCT patterns and graphical illustrations significantly improved the performance of trainees in characterizing and correctly identifying diffuse lung diseases.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Enfermedades Pulmonares/diagnóstico por imagen , Tomografía Computarizada Multidetector , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
6.
Eur Radiol ; 32(5): 3076-3084, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34713330

RESUMEN

OBJECTIVES: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. METHODS: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19-103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. RESULTS: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091-0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867-0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. CONCLUSIONS: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. KEY POINTS: •Dual-energy CT-derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).


Asunto(s)
Osteoporosis , Fracturas Osteoporóticas , Absorciometría de Fotón , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoporosis/complicaciones , Osteoporosis/diagnóstico por imagen , Osteoporosis/epidemiología , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/epidemiología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
7.
Acad Radiol ; 29(6): 880-887, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34266738

RESUMEN

PURPOSE: To assess the influence of intravenously injected contrast agent on bone mineral density (BMD) assessment in dual-source dual-energy CT. METHODS: This retrospective study included 1,031 patients (mean age, 53 ± 7 years; 519 women) who had undergone third-generation dual-source dual-energy CT in context of tumor staging between January 2019 and December 2019. Dedicated postprocessing software based on material decomposition was used for phantomless volumetric BMD assessment of trabecular bone of the lumbar spine. Volumetric trabecular BMD values derived from unenhanced and contrast-enhanced portal venous phase were compared by calculating correlation and agreement analyses using Pearson product-moment correlation, linear regression, and Bland-Altman plots. RESULTS: Mean BMD values were 115.53 ± 37.23 and 116.10 ± 37.78 mg/cm3 in unenhanced and contrast-enhanced dual-energy CT series, respectively. Values from contrast-enhanced portal venous phase differed not significantly from those of the unenhanced phase (p = 0.44) and showed high correlation (r = 0.971 [95% CI, 0.969-0.973]) with excellent agreement in Bland-Altman plots. Mean difference of the two phases was 0.61 mg/cm3 (95% limits of agreement, -17.14 and 18.36 mg/cm3). CONCLUSION: Portal venous phase dual-source dual-energy CT allows for accurate opportunistic BMD assessment of trabecular bone of the lumbar spine compared to unenhanced imaging. Therefore, dual-source CT may provide greater flexibility regarding BMD assessment in clinical routine and reduce radiation exposure by avoiding additional osteodensitometry examinations, as contrast-enhanced CT scans in context of tumor staging are increasingly performed in dual-energy mode.


Asunto(s)
Densidad Ósea , Medios de Contraste , Absorciometría de Fotón/métodos , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
8.
Eur Radiol ; 32(1): 561-571, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34215940

RESUMEN

OBJECTIVES: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. METHODS: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. RESULTS: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0-3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0-3) (p < .001). A cutoff value of - 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. CONCLUSIONS: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines. KEY POINTS: • In the setting of spinal trauma, dual-energy CT (DECT) is highly accurate in the evaluation of acute vertebral fractures and bone marrow edema presence and extent. • MRI provides moderate sensitivity and lower diagnostic confidence for the depiction of acute fracture lines, when compared to DECT, which might result in potentially inaccurate and underestimated severity assessment of injuries in certain cases when no fracture lines are visible on MRI. • DECT may represent a valid imaging alternative to MRI in specific settings of acute spinal trauma and in follow-up examinations, especially in elderly or unstable patients and in cases of subtle or complex orientated fracture lines.


Asunto(s)
Fracturas de la Columna Vertebral , Anciano , Médula Ósea , Edema/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos , Sensibilidad y Especificidad , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X
9.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34820684

RESUMEN

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Asunto(s)
Desplazamiento del Disco Intervertebral , Imagen Radiográfica por Emisión de Doble Fotón , Médula Ósea , Edema , Femenino , Humanos , Desplazamiento del Disco Intervertebral/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
10.
Eur Radiol Exp ; 5(1): 43, 2021 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-34608576

RESUMEN

BACKGROUND: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). METHODS: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. RESULTS: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984-0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. CONCLUSIONS: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.


Asunto(s)
Densidad Ósea , Tomografía Computarizada por Rayos X , Absorciometría de Fotón , Vértebras Lumbares/diagnóstico por imagen , Fantasmas de Imagen
11.
Eur Radiol Exp ; 5(1): 38, 2021 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-34476640

RESUMEN

Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of different body areas. The virtual non-calcium (VNCa) reconstruction algorithm has shown beneficial effects on the depiction of bone marrow pathologies such as bone marrow edema. Its main advantage is the ability to substantially increase the image contrast of structures that are usually covered with calcium mineral, such as calcified vessels or bone marrow, and to depict a large number of traumatic, inflammatory, infiltrative, and degenerative disorders affecting either the spine or the appendicular skeleton. Therefore, VNCa imaging represents another step forward for DECT to image conditions and disorders that usually require the use of more expensive and time-consuming techniques such as magnetic resonance imaging, positron emission tomography/CT, or bone scintigraphy. The aim of this review article is to explain the technical background of VNCa imaging, showcase its applicability in the different body regions, and provide an updated outlook on the clinical impact of this technique, which goes beyond the sole improvement in image quality.


Asunto(s)
Enfermedades de la Médula Ósea , Calcio , Médula Ósea , Humanos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
12.
Eur Radiol ; 31(12): 9221-9231, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34076743

RESUMEN

OBJECTIVES: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. METHODS: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. RESULTS: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89-0.96] vs 485/665 [73%; 95% CI, 0.67-0.80]), specificity (4775/4990 [96%; 95% CI, 0.90-0.98] vs 4066/4990 [82%; 95% CI, 0.79-0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93-0.98] vs 4551/5655 [81%; 95% CI, 0.74-0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). CONCLUSIONS: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT. KEY POINTS: • Color-coded VNCa reconstructions derived from third-generation dual-source dual-energy CT yielded significantly higher diagnostic accuracy for the assessment of thoracic disk herniation and spinal nerve root impingement compared to standard grayscale CT. • VNCa imaging provided higher diagnostic confidence and image quality at lower noise levels compared to standard grayscale CT. • Color-coded VNCa images may potentially serve as a viable imaging alternative to MRI under circumstances where MRI is unavailable or contraindicated.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Anciano , Médula Ósea , Edema , Femenino , Humanos , Estudios Retrospectivos , Sensibilidad y Especificidad
13.
Eur Radiol ; 31(7): 4428-4437, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33409799

RESUMEN

OBJECTIVES: To investigate the diagnostic accuracy of color-coded dual-energy CT virtual non-calcium (VNCa) reconstructions for the assessment of bone marrow edema (BME) of the scaphoid in patients with acute wrist trauma. METHODS: Our retrospective study included data from 141 patients (67 women, 74 men; mean age 43 years, range 19-80 years) with acute wrist trauma who had undergone third-generation dual-source dual-energy CT and 3-T MRI within 7 days. Eight weeks after assessment of conventional grayscale dual-energy CT scans for the presence of fractures, corresponding color-coded VNCa reconstructions were independently analyzed by the same six radiologists for the presence of BME. CT numbers on VNCa reconstructions were evaluated by a seventh radiologist. Consensus reading of MRI series by two additional radiologists served as the reference standard. RESULTS: MRI depicted 103 scaphoideal zones with BME in 76 patients. On qualitative analysis, VNCa images yielded high overall sensitivity (580/618 [94%]), specificity (1880/1920 [98%]), and accuracy (2460/2538 [97%]) for assessing BME as compared with MRI as reference standard. The interobserver agreement was excellent (κ = 0.98). CT numbers derived from VNCa images were significantly different in zones with and without edema (p < 0.001). A cutoff value of - 46 Hounsfield units provided a sensitivity of 91% and specificity of 97% for differentiating edematous scaphoid lesions. Receiver operating characteristic curve analysis revealed an overall area under the curve of 0.98. CONCLUSIONS: Qualitative and quantitative analyses showed excellent diagnostic accuracy of color-coded VNCa reconstructions for assessing traumatic BME of the scaphoid compared to MRI. KEY POINTS: • Color-coded virtual non-calcium (VNCa) reconstructions yield excellent diagnostic accuracy in assessing bone marrow edema of the scaphoid. • VNCa imaging enables detection of non-displaced fractures that are occult on standard grayscale CT. • Diagnostic confidence is comparable between VNCa imaging and MRI.


Asunto(s)
Médula Ósea , Hueso Escafoides , Adulto , Anciano , Anciano de 80 o más Años , Médula Ósea/diagnóstico por imagen , Calcio , Edema/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Hueso Escafoides/diagnóstico por imagen , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Adulto Joven
14.
Invest Radiol ; 56(4): 207-214, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33109918

RESUMEN

OBJECTIVES: The aim of this study was to investigative the diagnostic accuracy of colored dual-energy computed tomography (CT) virtual noncalcium (VNCa) series for analyzing cervical disk herniation compared with standard gray-scale CT images, with magnetic resonance imaging (MRI) serving as standard of reference. MATERIALS AND METHODS: Data from 57 patients who underwent noncontrast dual-source CT and 3.0-Tesla (T) MRI within 2 weeks between January 2017 and December 2018 were retrospectively analyzed. Five radiologists analyzed standard gray-scale dual-energy CT scans for the presence and degree of cervical disk herniation and spinal nerve root impingement. Readers reassessed scans after 8 weeks using colored VNCa series. Two experienced radiologists set the reference standard in consensus MRI reading sessions. Primary indices of diagnostic accuracy for both CT approaches were sensitivity and specificity, which were compared by application of the McNemar test. RESULTS: A total of 57 patients (mean age, 64 ± 11 years; 30 women) were evaluated (337 intervertebral disks). Magnetic resonance imaging indicated a total of 103 cervical disk herniations. The VNCa reconstructions had higher overall sensitivity compared with gray-scale CT (487/515 [95%; 95% confidence interval (CI), 91%-98%] vs 392/515 [76%; 95% CI, 70%-83%]), as well as higher specificity (1107/1170 [95%; 95% CI, 90%-99%] vs 906/1170 [77%; 95% CI, 72%-82%]) for assessing cervical disk herniation (all P < 0.001). The VNCa reconstructions had higher diagnostic accuracy for analyzing spinal nerve root impingement in comparison with gray-scale CT (sensitivity, 195/230 [85%; 95% CI, 79%-90%] vs 115/230 [50%; 95% CI, 40%-59%]; specificity, 1430/1455 [98%; 95% CI, 94%-100%] vs 1325/1455 [91%; 95% CI, 88%-98%]; accuracy, 1625/1685 [96%; 95% CI, 93%-99%] vs 1440/1685 [86%; 95% CI, 82%-90%]; all P < 0.001). CONCLUSIONS: Color-coded VNCa series improved the diagnostic accuracy for assessing cervical disk herniation and spinal nerve root impingement compared with standard gray-scale CT.


Asunto(s)
Médula Ósea , Edema , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
15.
Eur J Radiol ; 132: 109321, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33017775

RESUMEN

PURPOSE: To assess the diagnostic accuracy of phantomless dual-energy computed tomography (DECT)-based volumetric material decomposition to assess bone mineral density (BMD) of the lumbar spine for the detection of osteoporosis compared to Hounsfield unit (HU) measurements with dual x-ray absorptiometry (DXA) as reference standard. METHOD: A total of two hundred lumbar vertebrae in 53 patients (28 men, 25 women; mean age, 52 years, range, 23-87 years) who had undergone clinically-indicated third-generation dual-source DECT and DXA within 30 days were retrospectively analyzed. For volumetric BMD assessment, dedicated DECT postprocessing software using material decomposition was applied, which enables color-coded three-dimensional mapping of the trabecular BMD distribution. Manual HU measurements were performed by defining five trabecular regions of interest (ROI) per vertebra as suggested by literature. The DXA T-score served as standard of reference (osteoporosis: T < -2.5). Sensitivity, specificity and the area under the curve (AUC) were primary metrics of diagnostic accuracy. RESULTS: An optimal patient-based DECT-derived BMD cut-off of 84 mg/cm³ yielded 96 % sensitivity (22/23) and 93 % specificity (28/30) for detecting osteoporosis, while an optimal CT attenuation cut-off of 139 HU showed 65 % sensitivity (15/23) and 93 % specificity (28/30) for the detection of osteoporosis. Overall patient-based AUC were 0.930 (volumetric DECT) and 0.790 (HU analysis) (p < .001). Pearson's product-moment correlation showed higher correlation between DECT BMD and DXA values (r=0.780) compared to HU and DXA values (r=0.528) (p < .001). CONCLUSIONS: Phantomless volumetric DECT yielded significantly more accurate BMD assessment of the lumbar spine and superior diagnostic accuracy of osteoporosis compared to HU measurements.


Asunto(s)
Densidad Ósea , Tomografía Computarizada por Rayos X , Absorciometría de Fotón , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estándares de Referencia , Estudios Retrospectivos
16.
Invest Radiol ; 55(9): 619-627, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32776769

RESUMEN

Although artificial intelligence (AI) has been a focus of medical research for decades, in the last decade, the field of radiology has seen tremendous innovation and also public focus due to development and application of machine-learning techniques to develop new algorithms. Interestingly, this innovation is driven simultaneously by academia, existing global medical device vendors, and-fueled by venture capital-recently founded startups. Radiologists find themselves once again in the position to lead this innovation to improve clinical workflows and ultimately patient outcome. However, although the end of today's radiologists' profession has been proclaimed multiple times, routine clinical application of such AI algorithms in 2020 remains rare. The goal of this review article is to describe in detail the relevance of appropriate imaging data as a bottleneck for innovation, provide insights into the many obstacles for technical implementation, and give additional perspectives to radiologists who often view AI solely from their clinical role. As regulatory approval processes for such medical devices are currently under public discussion and the relevance of imaging data is transforming, radiologists need to establish themselves as the leading gatekeepers for evolution of their field and be aware of the many stakeholders and sometimes conflicting interests.


Asunto(s)
Aprendizaje Automático , Radiología/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Radiografía , Flujo de Trabajo
17.
Eur J Radiol ; 130: 109166, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32693314

RESUMEN

PURPOSE: Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA. METHODS: Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysis of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40 + . RESULTS: B-W/L and O-W/L for M70 were 580/210 and 560/200, and for M40+ were 1630/570 and 1560/550, respectively, higher than standard DE-CTA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding overall IQ (all p < 0.001). CONCLUSION: Application of O-W/L settings is mandatory to optimize subjective IQ of VMI reconstructions of DE-CTA.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Anciano , Arterias Carótidas/diagnóstico por imagen , Trastornos Cerebrovasculares/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
18.
Eur J Radiol ; 129: 109046, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32590258

RESUMEN

PURPOSE: To evaluate the diagnostic accuracy of color-coded dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of traumatic bone marrow edema in sacral insufficiency fracture (SIF). METHOD: Data from 52 consecutive patients (28 women, 24 men; mean age, 61 ±â€¯13 years; range, 49-94 years) who had undergone third-generation dual-source CT and 3-Tesla (T) MRI due to low back pain without adequate trauma were retrospectively evaluated. Five radiologists, blinded to MRI and clinical information, independently analyzed conventional grayscale dual-energy CT series for sacral fractures according to the Denis classification. Eight weeks later, readers re-assessed all scans using color-coded VNCa reconstructions for sacral bone marrow edema. CT numbers on VNCa reconstructions were measured by a sixth radiologist. One experienced radiologist (33 years of experience in musculoskeletal [MSK] imaging), blinded to CT and clinical information, defined the reference standard by analyzing the MRI scans. The primary indices for diagnostic accuracy were sensitivity, specificity, and the area under the curve (AUC). RESULTS: MRI revealed a total of 39 zones with SIF-associated bone marrow edema in 27 patients. In the qualitative analysis, VNCa showed high overall sensitivity (93 %) and specificity (95 %) for assessing SIF-associated bone marrow edema. The quantitative analysis of color-coded VNCa reconstructions revealed an overall AUC of 0.976. A cut-off value of -43 Hounsfield units provided a sensitivity of 85 % and a specificity of 95 % for differentiating bone marrow edema. CONCLUSIONS: Color-coded dual-energy CT VNCa reconstructions yield excellent diagnostic accuracy in the analysis of SIF-associated bone marrow edema compared to MRI.


Asunto(s)
Médula Ósea , Fracturas por Estrés , Anciano , Médula Ósea/diagnóstico por imagen , Edema/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
19.
J Clin Imaging Sci ; 10: 25, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32363087

RESUMEN

OBJECTIVE: Magnetic resonance enterography has achieved an increasingly importance in the evaluation of patients with Crohn's disease, although it is limited by high costs and prolonged scanning times. The aim of our work was to design a "fast" abbreviated MRE protocol and to compare it with the standard one. MATERIALS AND METHODS: A single-center retrospective study was performed on 73 patients with Crohn's disease who underwent MRE with standard protocol over a 7-month period. The images of the standard protocol were separated from those included in the proposed abbreviated one and independently evaluated by two radiologists with different years of experience in MRE imaging. Statistical analysis was performed with the Cohen kappa (κ) value, used to assess the agreement in case of categorical variables, the Lin's concordance correlation coefficient and Bland-Altman plot, in assessing the degree of agreement between numerical measurements, while the non- parametric Mann-Whitney U-test was used in comparing the evaluation times of the two protocols. RESULTS: The intraobserver evaluation showed a perfect agreement between the two protocols for presence, number and extension of lesions, abdominal complications, and excellent/perfect in identification of active inflammation.The interobserver reproducibility was excellent for overall presence and number of lesions, for the presence and number of lesions in any abdominal quadrant, inflammation, intestinal and extraintestinal complications, and lesions extension. CONCLUSION: The proposed protocol achieves comparable performance with standard MRE. Furthermore, it would carry potential benefits in terms of patient's comfort, time, and health-care costs savings.

20.
J Thorac Imaging ; 35 Suppl 1: S21-S27, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32317574

RESUMEN

The constantly increasing number of computed tomography (CT) examinations poses major challenges for radiologists. In this article, the additional benefits and potential of an artificial intelligence (AI) analysis platform for chest CT examinations in routine clinical practice will be examined. Specific application examples include AI-based, fully automatic lung segmentation with emphysema quantification, aortic measurements, detection of pulmonary nodules, and bone mineral density measurement. This contribution aims to appraise this AI-based application for value-added diagnosis during routine chest CT examinations and explore future development perspectives.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Aprendizaje Automático , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Flujo de Trabajo , Humanos , Pulmón/diagnóstico por imagen , Redes Neurales de la Computación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...