J Clin Virol ; 161: 105423, 2023 04.
Article En | MEDLINE | ID: mdl-36934591

BACKGROUND: Human Respiratory Syncytial Virus (RSV) infections pose a significant risk to human health worldwide, especially for young children. Whole genome sequencing (WGS) provides a useful tool for global surveillance to better understand the evolution and epidemiology of RSV and provide essential information that may impact on antibody treatments, antiviral drug sensitivity and vaccine effectiveness. OBJECTIVES: Here we report the development of a rapid and simplified amplicon-based one-step multiplex reverse-transcription polymerase chain reaction (mRT-PCR) for WGS of both human RSV-A and RSV-B viruses. STUDY DESIGN: Two mRT-PCR reactions for each sample were designed to generate amplicons for RSV WGS. This new method was tested and evaluated by sequencing 206 RSV positive clinical samples collected in Australia in 2020 and 2021 with RSV Ct values between 10 and 32. RESULTS: In silico analysis and laboratory testing revealed that the primers used in the new method covered most of the currently circulating RSV-A and RSV-B. Amplicons generated were suitable for both Illumina and Oxford Nanopore Technologies (ONT) NGS platforms. A success rate of 83.5% with a full coverage for the genome of 98 RSV-A and 74 RSV-B was achieved from all clinical samples tested. CONCLUSIONS: This assay is simple to set up, robust, easily scalable in sample preparation and relatively inexpensive, and as such, provides a valuable addition to existing NGS RSV WGS methods.


Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , Child , Humans , Child, Preschool , Respiratory Syncytial Virus, Human/genetics , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Virus Infections/epidemiology , Multiplex Polymerase Chain Reaction , Antiviral Agents , Sensitivity and Specificity
2.
ACS Appl Mater Interfaces ; 14(2): 2501-2509, 2022 Jan 19.
Article En | MEDLINE | ID: mdl-34990107

Rapid serology platforms are essential in disease pandemics for a variety of applications, including epidemiological surveillance, contact tracing, vaccination monitoring, and primary diagnosis in resource-limited areas. Laboratory-based enzyme-linked immunosorbent assay (ELISA) platforms are inherently multistep processes that require trained personnel and are of relatively limited throughput. As an alternative, agglutination-based systems have been developed; however, they rely on donor red blood cells and are not yet available for high-throughput screening. Column agglutination tests are a mainstay of pretransfusion blood typing and can be performed at a range of scales, ranging from manual through to fully automated testing. Here, we describe a column agglutination test using colored microbeads coated with recombinant SARS-CoV-2 spike protein that agglutinates when incubated with serum samples collected from patients recently infected with SARS-CoV-2. After confirming specific agglutination, we optimized centrifugal force and time to distinguish samples from uninfected vs SARS-CoV-2-infected individuals and then showed concordant results against ELISA for 22 clinical samples, and also a set of serial bleeds from one donor at days 6-10 postinfection. Our study demonstrates the use of a simple, scalable, and rapid diagnostic platform that can be tailored to detect antibodies raised against SARS-CoV-2 and can be easily integrated with established laboratory frameworks worldwide.


Agglutination Tests/methods , Antibodies, Viral/immunology , COVID-19 Serological Testing/methods , Diagnostic Tests, Routine/methods , Recombinant Proteins/immunology , Spike Glycoprotein, Coronavirus/immunology , Early Diagnosis , Humans , Sensitivity and Specificity
3.
ACS Sens ; 5(8): 2596-2603, 2020 08 28.
Article En | MEDLINE | ID: mdl-32672954

High-throughput and rapid serology assays to detect the antibody response specific to severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) in human blood samples are urgently required to improve our understanding of the effects of COVID-19 across the world. Short-term applications include rapid case identification and contact tracing to limit viral spread, while population screening to determine the extent of viral infection across communities is a longer-term need. Assays developed to address these needs should match the ASSURED criteria. We have identified agglutination tests based on the commonly employed blood typing methods as a viable option. These blood typing tests are employed in hospitals worldwide, are high-throughput, fast (10-30 min), and automated in most cases. Herein, we describe the application of agglutination assays to SARS-CoV-2 serology testing by combining column agglutination testing with peptide-antibody bioconjugates, which facilitate red cell cross-linking only in the presence of plasma containing antibodies against SARS-CoV-2. This simple, rapid, and easily scalable approach has immediate application in SARS-CoV-2 serological testing and is a useful platform for assay development beyond the COVID-19 pandemic.


Agglutination Tests/methods , Betacoronavirus/isolation & purification , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests/methods , Antibodies, Viral/blood , Betacoronavirus/immunology , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Humans , Pandemics , SARS-CoV-2 , Time Factors
4.
Clin Chem Lab Med ; 58(8): 1372-1380, 2020 07 28.
Article En | MEDLINE | ID: mdl-32145056

Background Laboratories use quality control (QC) testing to monitor the extent of normal variation. Assay lot number changes contribute the greatest amount of variation in infectious disease serology testing. An unexpected change in six lots of an anti-HCV assay allowed the determination of the effect these lot changes made to the assay's clinical sensitivity. Methods Two sets of seroconversion samples comprising of 44 individual samples and 9 external quality assessment scheme (EQAS) samples, all positive to anti-HCV, were tested in affected and unaffected assay lots, and the difference in the quantitative and qualitative results of the samples was analyzed. Results Of 44 low-positive seroconversion samples tested in affected and unaffected assay lots, only three samples had results reported below the assay cutoff when tested on two of the six affected assay lot. A further sample had results below the cutoff for only one affected lot. None of the EQAS samples reported false-negative results. Samples having a signal to cutoff value of less than 6.0 generally had lower results in the affected lots compared with the unaffected lots. Conclusions Unexpected changes in QC reactivity related to variation, in particular assay lot changes, may affect patient results. This study demonstrated that QConnect Limits facilitated the detection of an unexpectedly large variation in QC test results, allowed for the identification of the root cause of the change, and showed that the risk associated with the change was low but credible. The use of evidence-based QC program is essential to detect changes in test systems.


Hepatitis C Antibodies/blood , Hepatitis C/diagnosis , Quality Control , Hepatitis C/immunology , Humans , Sensitivity and Specificity
...