Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 32(9): 15215-15230, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38859178

RESUMEN

The significance of timing jitter stems from its pivotal role in enhancing the precision of applications like spectroscopy and frequency metrology. In this study, we introduce a comprehensive procedure for achieving low timing jitter values in mode-locked fiber laser systems, highlighting dispersion, intracavity pulse energy, pulse length, and spectral bandwidth as key parameters. Notably, we unveil the influence of fiber amplifier pump power on jitter, a factor neglected in established theories and recent experiments. Applying this procedure to a 200-MHz all-polarization-maintaining (PM) erbium-doped (Er:) nonlinear amplifying loop mirror (NALM) fiber laser system, we demonstrate an exceptionally low timing jitter of 14.25 attoseconds, measured using the balanced optical cross-correlation (BOC) technique and integrated from 10 kHz to 4 MHz. The implementation of our novel method offers the opportunity to improve jitter results in various fiber laser systems and increase the accuracy of fiber laser applications.

2.
Opt Express ; 28(10): 15023-15024, 2020 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-32403534

RESUMEN

In this erratum we correct errors in the scaling and caption of Fig. 4 in the original manuscript [1].

3.
Sci Rep ; 10(1): 2523, 2020 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-32054902

RESUMEN

Frequency combs have made optical metrology accessible to hundreds of laboratories worldwide and they have set new benchmarks in multi-species trace gas sensing for environmental, industrial and medical applications. However, current comb spectrometers privilege either frequency precision and sensitivity through interposition of a cw probe laser with limited tuning range, or spectral coverage and measurement time using the comb itself as an ultra-broadband probe. We overcome this restriction by introducing a comb-locked frequency-swept optical synthesizer that allows a continuous-wave laser to be swept in seconds over spectral ranges of several terahertz while remaining phase locked to an underlying frequency comb. This offers a unique degree of versatility, as the synthesizer can be either repeatedly scanned over a single absorption line to achieve ultimate precision and sensitivity, or swept in seconds over an entire rovibrational band to capture multiple species. The spectrometer enables us to determine line center frequencies with an absolute uncertainty of 30 kHz and at the same time to collect absorption spectra over more than 3 THz with state-of-the-art sensitivity of a few 10-10 cm-1. Beyond precision broadband spectroscopy, the proposed synthesizer is an extremely promising tool to force a breakthrough in terahertz metrology and coherent laser ranging.

4.
Opt Express ; 27(25): 36886-36902, 2019 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-31873460

RESUMEN

We introduce a simple and robust scheme for optical frequency transfer of an ultra-stable source light field via an optical frequency comb to a field at a target optical frequency, where highest stability is required, e.g., for the interrogation of an optical clock. The scheme relies on a topology for end-to-end suppression of the influence of optical path-length fluctuations, which is attained by actively phase-stabilized delivery, combined with common-path propagation. This approach provides a robust stability improvement without the need for additional isolation against environmental disturbances such as temperature, pressure or humidity changes. We measure residual frequency transfer instabilities by comparing the frequency transfers carried out with two independent combs simultaneously. Residual fractional frequency instabilities between two systems of 8 × 10-18 at 1 s and 3 × 10-21 at 105 s averaging time are observed. We discuss the individual noise contributions to the residual instability. The presented scheme is technically simple, robust against environmental parameter fluctuations and enables an ultra-stable frequency transfer, e.g., to optical clock lasers or to lasers in gravitational wave detectors.

5.
Opt Express ; 18(6): 6097-107, 2010 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-20389631

RESUMEN

We report on a first experimental study of the molecular properties of nematic liquid crystals in the terahertz range. In the beginning, we extract the frequency and temperature dependent refractive index and absorption coefficient of the cyanobiphenyls 5CB, 6CB and 7CB from terahertz time domain spectroscopy measurements and investigate the impact of the alkyl chain length on the macroscopic liquid crystal characteristics, focusing especially on the pronounced odd and even effect. Next, we deduce the principle polarizabilities and the order parameter S by applying Vuks' approximation and Haller's approach. On this basis, we calculate the main polarizabilities along the longitudinal and transverse axis and link the observed terahertz properties to the molecular structure of the liquid crystals.


Asunto(s)
Cristales Líquidos/química , Modelos Químicos , Simulación por Computador , Luz , Refractometría , Dispersión de Radiación , Radiación Terahertz
6.
Opt Express ; 18(2): 1613-7, 2010 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-20173988

RESUMEN

Most time-resolved optical experiments rely either on external mechanical delay lines or on two synchronized femtosecond lasers to achieve a defined temporal delay between two optical pulses. Here, we present a new method which does not require any external delay lines and uses only a single femtosecond laser. It is based on the cross-correlation of an optical pulse with a subsequent pulse from the same laser. Temporal delay between these two pulses is achieved by varying the repetition rate of the laser. We validate the new scheme by a comparison with a cross-correlation measurement carried out with a conventional mechanical delay line.


Asunto(s)
Tecnología de Fibra Óptica/instrumentación , Rayos Láser , Refractometría/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo/métodos
7.
Opt Express ; 17(9): 7377-82, 2009 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-19399116

RESUMEN

We demonstrate the first electronically switchable Bragg structure for THz frequencies. The structure works as stop-band filter and as mirror. It exhibits the 60 GHz broad stop-band around 300 GHz which can be removed by reorienting liquid crystal molecules in an external electric field. Our first proof-of-principle experiments agree very well with transfer matrix calculations.


Asunto(s)
Electrónica/instrumentación , Iluminación/instrumentación , Cristales Líquidos/química , Refractometría/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Radiación Terahertz
8.
Appl Opt ; 47(16): 3023-6, 2008 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-18516122

RESUMEN

We present a low cost terahertz (THz) spectrometer with coherent detection based on two simple and robust dipole antennas driven by two laser diodes. The spectrometer covers frequencies up to 1 THz, with a peak signal-to-noise ratio exceeding 40 dB for a lock-in integration time of 30 ms. We demonstrate that the thickness profile of a sample can be reconstructed from an acquired THz image.


Asunto(s)
Óptica y Fotónica , Espectrofotometría/métodos , Electrodos , Fenómenos Electromagnéticos , Diseño de Equipo , Rayos Láser , Polietileno/química , Control de Calidad , Proyectos de Investigación , Temperatura , Factores de Tiempo
10.
Opt Express ; 15(7): 4335-50, 2007 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-19532679

RESUMEN

We improve the existing data extraction algorithms for THz time-domain spectroscopy (THz TDS) in two aspects. On the one hand, we merge the up-to-date knowledge of THz TDS signal processing into a single powerful optical material parameter extraction algorithm. On the other hand, we introduce a novel iterative algorithm that further enhances the accuracy of the parameter extraction. In contrast to most of the published experiments, we are able to reliably investigate samples with thicknesses as small as 100microm, samples with low indexes of refraction, i.e. close to 1, as well as samples with sharp peaks in the material parameter curves.

11.
Opt Express ; 13(14): 5205-15, 2005 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-19498511

RESUMEN

We use terahertz time-domain spectroscopy (THz-TDS) to measure the far-infrared dielectric function of two artificial RNA single strands, composed of polyadenylic acid (poly-A) and polycytidylic acid (poly-C). We find a significant difference in the absorption between the two types of RNA strands, and we show that we can use this difference to record images of spot arrays of the RNA strands. Under controlled conditions it is possible to use the THz image to distinguish between the two RNA strands. We discuss the requirements to sample preparation imposed by the lack of sharp spectral features in the absorption spectra.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA