Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Mass Spectrom Adv Clin Lab ; 32: 24-30, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38405411

RESUMEN

Introduction: Therapeutic drug monitoring of infliximab has become the standard of care for inflammatory bowel disease in the setting of loss of response to therapy, and occasionally in proactive therapy personalization. Measurement of infliximab by tryptic peptide HPLC-MS/MS has been available since 2015, mostly in reference laboratories. Objectives: Here, we present method improvements to our original published method leading to a more efficient, robust, and high throughput tryptic peptide HPLC-MS/MS assay for infliximab quantitation. Methods: Deidentified residual serum samples submitted for clinical testing were used for method comparison and infliximab was spiked into normal human serum for performance studies. Improvements included the addition of a stable isotope labeled full length infliximab internal standard (IS) replacing a surrogate IS, and immunoenrichment using Melon Gel for immunoglobulins replacing the saturated ammonium sulfate precipitation. Digestion and chromatography were optimized, and automation was added. The method improvements were validated to include precision, accuracy, reportable range, linearity, and analytical sensitivity. Results: The digestion time was reduced from overnight to 1 h. The assay analytical measuring range (AMR) remained the same throughout improvements, 1-100 µg/mL, with linearity of 0.98x + 0.50, R2 = 1.00. Intra- and inter-assay imprecision were less than 5 % CV at four different concentrations. Accuracy was assessed with 106 patients within the AMR; Passing-Bablok Regression yielded a slope of 1.00 and a y-intercept of 0.25. Turnaround time was reduced by 1 day, and imprecision of three levels of quality control trended down after new method implementation. Conclusions: Method improvements including automation have allowed for assay completion in half a day, improving robustness and turnaround time.

2.
Mayo Clin Proc Innov Qual Outcomes ; 6(5): 458-464, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36160640

RESUMEN

One of the treatment options for complement-mediated thrombotic microangiopathy (CM-TMA), also known as atypical hemolytic uremic syndrome, is the administration of the C5 complement inhibitor eculizumab. In vivo studies have reported a complete complement blockade with eculizumab serum concentrations above 50 µg/mL in the case of atypical hemolytic uremic syndrome. The eculizumab trough levels and C5 functional activity were monitored in patients with CM-TMA being treated with eculizumab. For those with eculizumab trough concentrations of more than 100 µg/mL, the frequency of eculizumab 1200-mg doses was decreased. In this article, we describe the pharmacologic monitoring data with the use of C5 functional activity and mass spectrometric assessments of eculizumab to allow for a tailored eculizumab schedule for 10 patients with CM-TMA. In 9 out of 10 (90%) patients with a standard administration schedule, eculizumab trough concentrations were more than 100 µg/mL. At the time of the last eculizumab follow-up (median, 250 days; range, 85-898 days), the interval between eculizumab infusions was extended to every 3-6 weeks for 8 patients; no disease relapse was found with the modified dosing interval. Altering the administration of maintenance eculizumab from every 2-3 weeks to 3-6 weeks yields a savings of $78,185 per patient for a 6-month eculizumab treatment course. Although larger standardized cohorts are necessary to confirm these findings, our data suggest that monitoring eculizumab levels in conjunction with C5 assessment allows for safe modification of eculizumab dosing and results in considerable cost savings.

3.
Mayo Clin Proc ; 97(2): 294-307, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34887112

RESUMEN

OBJECTIVES: To verify the analytical performance of a new mass spectrometry-based method, termed MASS-FIX, when screening for plasma cell disorders in a routine clinical laboratory. PATIENTS AND METHODS: Results from 19,523 unique patients tested for an M-protein between July 24, 2018, and March 6, 2020, by a combination serum protein electrophoresis (SPEP) and MASS-FIX were examined for consistency with pretest implementation performance. MASS-FIX's ability to verify abnormal results from SPEP and free light chain measurements was then compared with that of immunofixation electrophoresis (IFE) using a separate cohort of 52,586 patients tested by SPEP/IFE during the same period. RESULTS: Overall, 62.4% of our cohort was negative for an M-protein. Importantly, 7.3% of all specimens had an M spike on SPEP (0.1 to 8.5 g/dL) and MASS-FIX detected an M-protein in all these samples. Of all samples, 30.3% had M-proteins that were detected by MASS-FIX but the SPEP finding was too small for quantification. Of the positive samples, 5.7% contained a therapeutic monoclonal antibody. Of the positive samples, 4.1% had an N-glycosylated light chain (biomarker of high-risk plasma cell disorders). MASS-FIX confirmed a higher percentage of SPEP abnormalities than IFE. MASS-FIX was slightly more sensitive than IFE when confirming an M-protein in samples with an abnormal free light chain ratio. MASS-FIX had a very low sample repeat rate (1.5%). MASS-FIX was highly automatable resulting in a higher number of samples/technologist/day than IFE (∼30% more). CONCLUSION: Overall, MASS-FIX was successful in maintaining validation characteristics. MASS-FIX was more sensitive in confirming SPEP abnormalities when compared with IFE. Ability to detect therapeutic monoclonal antibodies and glycosylated light chains was distinctly advantageous.


Asunto(s)
Cadenas Ligeras de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Paraproteinemias/diagnóstico , Biomarcadores/sangre , Electroforesis de las Proteínas Sanguíneas/métodos , Femenino , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Paraproteinemias/sangre , Sensibilidad y Especificidad
4.
J Mass Spectrom Adv Clin Lab ; 21: 10-18, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34820672

RESUMEN

INTRODUCTION: Ravulizumab (RAVUL) is a new complement inhibitor, with a difference of 4 amino acids in the heavy chain from a predecessor compound, eculizumab (ECUL). OBJECTIVES: First, to utilize mass spectrometry (MS) to characterize RAVUL and verify differences from its predecessor and, second, to validate and implement a lab developed test (LDT) for RAVUL that will allow for quantitative therapeutic monitoring. METHODS: A time-of-flight mass spectrometer (TOF-MS) was used to characterize and differentiate the molecular weight differences between RAVUL and ECUL by both digest and reduction experiments. In parallel, an LDT for RAVUL was validated and implemented utilizing IgG4 enrichment with light chain detection and quantitation on a high throughput orbitrap MS platform. RESULTS: The TOF-MS platform allowed for the mass difference between RAVUL and ECUL to be verified along with providing a proof of concept for a new intact protein quantitation software. An LDT on an orbitrap MS was validated and implemented using intact light chain quantitation, with the limitation that it cannot differentiate between ECUL and RAVUL. The LDT has an analytical measuring range from 5 to 600 mcg/mL, inter-assay imprecision of ≤13% CV (n = 13) and accuracy with <4% error from expected values (n = 20). CONCLUSION: The TOF-MS is a versatile development platform that can be used to characterize and verify the molecular weight differences between the ECUL and RAVUL heavy chains. Routine laboratory testing for RAVUL was viable using an orbitrap-MS to quantitate using the mass of the intact light chain. These two platforms, combined, provide incomparable value in development of LDTs for the clinical laboratory.

5.
Clin Biochem ; 97: 67-73, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34384797

RESUMEN

BACKGROUND: Plasma cell disorders (PCDs) are typically characterized by excessive production of a single immunoglobulin, defined as a monoclonal protein (M-protein). Some patients have more than one identifiable M-protein, termed biclonal. Traditional immunofixation electrophoresis (IFE) cannot distinguish if two bands of the same isotype represent biclonal proteins or M-proteins with some other feature. A novel assay using immunoenrichment coupled to matrix-assisted laser desorption ionization time-of-flight mass-spectrometry (Mass-Fix) was applied to determine whether two bands of the same isotype represented (1) monomers and dimers of a single M-protein, (2) an M-protein plus a therapeutic monoclonal antibody (t-mAb), (3) an M-protein with light chain glycosylation, or (4) two distinct biclonal M-proteins. METHODS: Patient samples with two bands of the same isotype identified by IFE were enriched using nanobodies against IgG, IgA, IgM, or κ and λ light chains then analyzed by Mass-Fix. Light chain masses were used to differentiate IgGκ M-proteins from t-mAbs. Mass differences between peaks were calculated to identify N-glycosylation or matrix adducts. High-resolution mass spectrometry was used as a comparator method in a subset of samples. RESULTS: Eighty-one residual samples were collected. For IgA, 93% (n = 25) were identified as monoclonal. For IgG, 67% (n = 24) were monoclonal, and 33% (n = 12) were truly biclonal. Among the monoclonal IgGs, the second band represented a glycosylated form for 21% (n = 5), while 33% (n = 8) had masses consistent with a t-mAb. 44% (n = 8) of IgM samples were biclonal, and 56% (n = 10) were monoclonal, of which one was glycosylated. CONCLUSIONS: We demonstrate the utility of mass spectrometry in the characterization of multiple IFE bands of the same isotype. Improved reporting accuracy of M-proteins is useful for monitoring of patients with PCDs.


Asunto(s)
Anticuerpos Monoclonales/sangre , Inmunoelectroforesis/métodos , Proteínas de Mieloma/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales/química , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/química , Masculino , Persona de Mediana Edad , Mieloma Múltiple/sangre , Proteínas de Mieloma/química , Multimerización de Proteína , Espectrometría de Masa por Ionización de Electrospray
8.
J Allergy Clin Immunol Pract ; 9(9): 3293-3307.e6, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34033983

RESUMEN

Knowledge related to the biology of inborn errors of immunity and associated laboratory testing methods continues to expand at a tremendous rate. Despite this, many patients with inborn errors of immunity suffer for prolonged periods of time before identification of their underlying condition, thereby delaying appropriate care. Understanding that test selection and optimal evaluation for patients with recurrent infections or unusual patterns of inflammation can be unclear, we present a document that distills relevant clinical features of immunologic disease due to inborn errors of immunity and related appropriate and available test options. This document is intended to serve the practicing clinical immunologist and, in turn, patients by describing best available test options for initial and expanded immunologic evaluations across the disease spectrum. Our goal is to demystify the process of evaluating patients with suspected immune dysfunction and to enable more rapid and accurate diagnosis of such individuals.


Asunto(s)
Laboratorios , Enfermedades de Inmunodeficiencia Primaria , Humanos , Inflamación , Motivación , Reinfección
9.
Clin Biochem ; 92: 61-66, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33691184

RESUMEN

OBJECTIVE: To explore the possibility of using a combination of a rapid MALDI-TOF-MS method (Mass-Fix) in conjunction with higher resolution LC-ESI-QTOF-MS (miRAMM) measurements to discriminate the IgG kappa M-protein from daratumumab, elotuzumab and isatuximab in myeloma patients. DESIGN & METHODS: 86 patients with an IgG kappa M-protein were spiked with therapeutic levels of the drugs and examined by Mass-Fix and miRAMM to establish the percent of cases that could be resolved by each method. The method was then applied to 21 samples from patients receiving one of the drugs. RESULTS: Mass-Fix was capable of resolving the t-mAb from M-protein for 87 percent of the spiked samples. For the cases unresolved by Mass-Fix, miRAMM was capable of resolving the remaining drug interferences. The 21 IgG kappa myeloma patients that were receiving the drugs were all resolved by Mass-Fix. CONCLUSION: This proposed algorithm allows use of a clinical available assay (Mass-Fix) while maximizing the number of cases that can accurately resolve the t-mAb from the M-protein.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Anticuerpos Monoclonales , Mieloma Múltiple , Proteínas de Mieloma/aislamiento & purificación , Anticuerpos Monoclonales/administración & dosificación , Anticuerpos Monoclonales/sangre , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/sangre , Antineoplásicos/administración & dosificación , Antineoplásicos/sangre , Electroforesis de las Proteínas Sanguíneas , Cromatografía Liquida , Humanos , Mieloma Múltiple/sangre , Mieloma Múltiple/tratamiento farmacológico , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
10.
Blood Cancer J ; 11(3): 50, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-33664227

RESUMEN

Immunoenrichment-based matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS), termed MASS-FIX, offers several advantages over immunofixation for the detection and isotyping of serum monoclonal protein, including superior sensitivity and specificity, the ability to differentiate therapeutic monoclonal antibodies, and the rapid identification of light chain (LC) N-glycosylation. We identified 6315 patients with MASS-FIX performed at our institution since 2018. Of these, 4118 patients (65%) with a wide array of plasma cell disorders (PCD), including rare monoclonal gammopathies of clinical significance, had a positive MASS-FIX. Two-hundred twenty-one (5%) of the MASS-FIX positive patients had evidence of LC N-glycosylation, which was more commonly identified in IgM heavy chain isotype, kappa LC isotype, and in diagnoses of immunoglobulin light chain (AL) amyloidosis and cold agglutinin disease (CAD) compared to other PCD. This cross-sectional study describes the largest cohort of patients to undergo MASS-FIX in routine clinical practice. Our findings demonstrate the widespread utility of this assay, and confirm that LC N-glycosylation should prompt suspicion for AL amyloidosis and CAD in the appropriate clinical context.


Asunto(s)
Paraproteinemias/sangre , Anciano , Estudios Transversales , Femenino , Glicosilación , Humanos , Cadenas Pesadas de Inmunoglobulina/sangre , Cadenas Ligeras de Inmunoglobulina/análisis , Cadenas Ligeras de Inmunoglobulina/sangre , Inmunoglobulina M/análisis , Inmunoglobulina M/sangre , Cadenas kappa de Inmunoglobulina/análisis , Cadenas kappa de Inmunoglobulina/sangre , Masculino , Persona de Mediana Edad , Paraproteinemias/diagnóstico , Paraproteínas/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
11.
J Immunol Methods ; 490: 112944, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33321132

RESUMEN

Ravulizumab is a new C5 inhibitor therapeutic monoclonal antibody with a longer half-life than eculizumab. Monitoring complete complement blockade by eculizumab has allowed personalized therapy in specific settings. Similar action is expected with ravulizumab. Ravulizumab has 4 different amino acids from eculizumab, which allow greater affinity for the FcRn immunoglobulin receptor and change the affinity of the molecule for C5. Here we investigate if clinical lab tests traditionally used to monitor complement blockade for eculizumab are appropriate for monitoring complement blockade caused by ravulizumab. De-identified serum samples with known normal complement activity were spiked with increasing amounts of ravulizumab, from zero to 1000 µg/mL. Measurement of classical pathway function (CH50) and C5 function using a liposome method (Wako Diagnostics) showed >50% complement inhibition starting with 50 µg/mL of ravulizumab, but inhibition >95% of complement activity was not achieved, with residual measurements of 11% at 700 µg/mL. In contrast, measurement of alternative pathway function using an ELISA (AH50, Wieslab) showed alternative pathway function inhibition of 80% at 50 µg/mL of ravulizumab and > 95% at 200 µg/mL, which is consistent with expected therapeutic concentrations of ravulizumab >175 µg/mL. If replicated in patient sera, AH50 could be a suitable therapeutic monitoring tool.


Asunto(s)
Anticuerpos Monoclonales Humanizados/uso terapéutico , Síndrome Hemolítico Urémico Atípico/tratamiento farmacológico , Inactivadores del Complemento/uso terapéutico , Inmunoensayo/métodos , Adulto , Anticuerpos Monoclonales Humanizados/farmacología , Complemento C5/antagonistas & inhibidores , Inactivadores del Complemento/farmacología , Vía Clásica del Complemento , Antígenos de Histocompatibilidad Clase I/metabolismo , Humanos , Liposomas/metabolismo , Masculino , Monitorización Inmunológica , Medicina de Precisión , Receptores Fc/metabolismo
12.
Lab Med ; 52(4): 315-328, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33283241

RESUMEN

OBJECTIVE: Regulations for clinical laboratories in the United States are complex. The goal of this review is to improve the clarity of laboratory-developed test (LDT) regulation to facilitate innovation. METHODS: A literature and regulation review of current legislation for compliance by U.S. clinical laboratories was performed, and examples of the steps to implement LDTs within compliance with the regulatory environment are shared. RESULTS: Many federal and state jurisdictions are critical to the functionality of a laboratory in addition to upcoming potential promulgation of the Verifying Accurate Leading-Edge IVCT Development Act. Increased regulation, although imperative to maintain consistent, high-standard clinical care, could mean additional costs for developers and healthcare while also hindering innovation. CONCLUSION: An extensive discussion of proposed regulations for LDTs needs to occur. Laboratory testing requires the sustained use of innovative methods at a cost that will permit continued, timely, uninterrupted high-quality service.


Asunto(s)
Servicios de Laboratorio Clínico , Laboratorios Clínicos , Humanos , Estados Unidos , United States Food and Drug Administration
14.
Clin Chem Lab Med ; 58(6): 864-872, 2020 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-31756160

RESUMEN

Background While quantitation methods for small-molecule and tryptic peptide bottom-up mass spectrometry (MS) have been well defined, quantitation methods for top-down or middle-up MS approaches have not been as well defined. Therapeutic monoclonal antibodies (t-mAbs) are a group of proteins that can be used to both demonstrate the advantages of top-down or middle-up detection methods over classic tryptic peptide bottom-up along with the growing need for robust quantitation strategies/software for these top-down or middle-up methods. Bottom-up proteolytic digest methods for the t-mAbs tend to suffer from challenges such as limited peptide selection due to potential interference from the polyclonal immunoglobulin background, complicated workflows, and inadequate sensitivity and specificity without laborious purification steps, and therefore have prompted the search for new detection and quantitation methods. Time-of-flight along with Orbitrap MS have recently evolved from the research and/or pharmaceutical setting into the clinical laboratory. With their superior mass measurement accuracy, resolution and scanning speeds, these are ideal platforms for top-down or middle-up characterization and quantitation. Methods We demonstrate a validated, robust, middle-up protein subunit detection and quantitation method for the IgG1 t-mAb, vedolizumab (VEDO), which takes advantage of the high resolution of the Orbitrap MS detection and quantitation software to increase specificity. Results Validated performance characteristics met pre-defined acceptance criteria with simple workflows and rapid turnaround times: characteristics necessary for implementation into a high-volume clinical MS laboratory. Conclusions While the extraction method can easily be used with other IgG1 t-mAbs, the detection and quantitation method may become an option for measurement of other proteins.


Asunto(s)
Anticuerpos Monoclonales Humanizados/análisis , Espectrometría de Masas/métodos , Subunidades de Proteína/química , Humanos , Programas Informáticos
17.
Clin Chem ; 65(8): 1015-1022, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31171529

RESUMEN

BACKGROUND: Free light chain (FLC) quantification is the most analytically sensitive blood-based method commercially available to diagnose and monitor patients with plasma cell disorders (PCDs). However, instead of directly detecting monoclonal FLCs (mFLCs), FLC assays indirectly assess clonality based on quantifying κ and λ FLCs and determination of the к/λ FLC ratio. Often an abnormal FLC ratio is the only indication of a PCD, and confirmation by a direct method increases diagnostic confidence. The aim of this study was to develop an analytically sensitive method for direct detection of mFLCs. METHODS: Patient sera (n = 167) previously assessed by nephelometric FLC quantification and immunofixation electrophoresis (IFE) were affinity enriched for IgG, IgA, and total and free κ and λ light chains and subjected to MALDI-TOF MS. Relative analytical sensitivity of these methods was determined using serially diluted sera containing mFLCs. RESULTS: In sera with abnormal FLC ratios (n = 127), 43% of monoclonal proteins were confirmed by IFE, 57% by MALDI-TOF MS without FLC enrichment, and 87% with FLC enrichment MALDI-TOF MS. In sera with normal FLC ratios (n = 40), the FLC MALDI-TOF MS method identified 1 patient with an mFLC. Serial dilution and analysis of mFLC containing sera by IFE, nephelometry, and FLC MALDI-TOF MS demonstrated that FLC MALDI-TOF MS analysis had the highest analytical sensitivity. CONCLUSIONS: FLC immunoenrichment coupled to MALDI-TOF MS enables direct detection of mFLCs and significantly increases the confirmation of abnormal serum FLC ratios over IFE and MALDI-TOF MS without FLC enrichment, thereby providing added confidence for diagnosing FLC PCDs.


Asunto(s)
Anticuerpos Monoclonales/sangre , Cadenas Ligeras de Inmunoglobulina/sangre , Paraproteinemias/sangre , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Cadenas kappa de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Inmunoglobulinas/sangre , Proteínas de Mieloma/análisis , Nefelometría y Turbidimetría , Sensibilidad y Especificidad
18.
Mayo Clin Proc ; 93(10): 1351-1362, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30286829

RESUMEN

OBJECTIVE: To investigate the clinical utility of a 9-analyte complement serology panel (COMS) covering complement function (CH50 and AH50), components (C3, C4), factor B (CFB), factor H, and activation markers (C4d, Bb, and soluble membrane attack complex) for the diagnosis of atypical hemolytic uremic syndrome (aHUS). METHODS: Physician orders for COMS from January 19, 2015, through November 4, 2016, were reviewed. Demographic characteristics, patient diagnosis, and laboratory parameters were recorded. RESULTS: There were 177 COMS orders for 147 patients. The median patient age was 44.9 years (range, 0.9-88.0 years). Common reasons for ordering COMS included monitoring and diagnosis of C3 glomerulopathy and renal dysfunction and differentiation of aHUS from other thrombotic microangiopathies (TMAs). Forty-four patients had COMS ordered for TMAs: 8 had aHUS and all had 1 or more abnormalities within the alternative pathway of complement. Although the sensitivity of this finding for the diagnosis of aHUS is 100%, the specificity is only 28%, with a positive likelihood ratio of 1.39. Patients with aHUS had lower CH50, C3, and CFB than did those with secondary non-aHUS TMA (all P<.01). A combined CFB of 20.9 mg/dL or less and CH50 of 56% or less led to sensitivity of 75% with increased specificity of 88.9% and a diagnostic odds ratio of 24. CONCLUSION: A COMS abnormality should not be interpreted in isolation. In conjunction with clinical presentation, a decrease in both CFB and CH50 may be an important clue to support the diagnosis of aHUS.


Asunto(s)
Síndrome Hemolítico Urémico Atípico , Activación de Complemento/inmunología , Ensayo de Actividad Hemolítica de Complemento , Proteínas del Sistema Complemento/inmunología , Monitorización Inmunológica/métodos , Adulto , Síndrome Hemolítico Urémico Atípico/diagnóstico , Síndrome Hemolítico Urémico Atípico/inmunología , Sistemas de Información en Laboratorio Clínico/estadística & datos numéricos , Ensayo de Actividad Hemolítica de Complemento/métodos , Ensayo de Actividad Hemolítica de Complemento/estadística & datos numéricos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Microangiopatías Trombóticas/diagnóstico
19.
J Immunol Methods ; 461: 15-22, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30031798

RESUMEN

Thrombotic microangiopathies (TMA) are a class of disorders characterized by microangiopathic hemolytic anemia, non-immune thrombocytopenia, and organ dysfunction. One type of TMA is atypical hemolytic uremic syndrome (aHUS) a disorder caused by hyper-activation of the alternative complement pathway due to over activation of C3 convertases and loss of complement regulatory mechanisms. The pathophysiological mechanism of aHUS involves increased continuous spontaneous hydrolysis of C3 to C3b which leads to tissue deposition of C3b, the membrane attack complex formation and subsequent tissue injury. The underlying susceptibility factors to aHUS include acquired autoantibodies or germline mutations in complement proteins or their regulators. Currently there are no clear diagnostic criteria for aHUS. Diagnosis involves ruling out other causes of TMA and incorporating complement serologic and genetic data. TPE has been used to treat aHUS; however, clinical improvement in these patents is far less than in patients with thrombotic thrombocytopenic purpura. Furthermore, there is a higher rate of progression to end stage renal disease with almost half of patients progressing despite TPE. For those, another option for treatment is eculizumab, a monoclonal antibody that blocks complement C5. Eculizumab has proven effective in aHUS and dramatically changed the prognosis of this syndrome. In this review the clinical presentation, diagnosis and management of aHUS are highlighted with three clinical cases.


Asunto(s)
Anticuerpos Monoclonales Humanizados/uso terapéutico , Síndrome Hemolítico Urémico Atípico , Complemento C3b/metabolismo , Complemento C5/metabolismo , Vía Alternativa del Complemento/efectos de los fármacos , Síndrome Hemolítico Urémico Atípico/sangre , Síndrome Hemolítico Urémico Atípico/diagnóstico , Síndrome Hemolítico Urémico Atípico/tratamiento farmacológico , Síndrome Hemolítico Urémico Atípico/genética , Complemento C5/antagonistas & inhibidores , Complemento C5/genética , Humanos , Pronóstico
20.
J Immunol Methods ; 460: 63-71, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29935209

RESUMEN

BACKGROUND: Eculizumab (ECU) blocks complement C5 cleavage, preventing the formation of C5a and the cytolytic effects of the membrane attack complex. The presence of ECU in blood impacts routine complement tests used to monitor treatment. METHODS: Residual serum samples with normal total complement (CH50) and residual citrate plasma with normal PT/APTT were spiked with ECU at varied concentrations ranging from 25 to 600 µg/mL. In addition, seventy-one samples from patients on ECU were obtained. Artificial and patient samples were analyzed for CH50 and C5 function (Wako Diagnostics), C5 concentration (Quidel), AH50 (Wieslab ELISA) and sMAC (Quidel). ECU concentration was measured by mass spectrometry for all patients. RESULTS: Complement blockage by ECU was evident in spiked artificial samples. At 25 µg/mL ECU, partial complement blockage was observed in CH50, AH50 and C5 function in serum. Complete blockage defined by undetectable AH50 (<10%) occurred at 100 µg/mL ECU. C5 concentrations remained the same regardless of ECU. sMAC results stayed around 81% of baseline in serum and 47% in citrate plasma with 50µg/mL ECU. Patient samples had ECU ranging from <5 to 1220 µg/mL. In all patients with ECU >100 µg/mL, C5 function was <29 U/mL. CONCLUSIONS: The spiked sera and patient samples showed complement blockage with CH50, AH50 and C5 function assays when ECU >100 µg/mL. CH50, AH50 or C5 function assays can serve as indicators for the pharmacodynamic effects of eculizumab. Allied to ECU concentration, laboratory studies may be helpful to tailor therapy.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Activación de Complemento/efectos de los fármacos , Complemento C5/metabolismo , Complejo de Ataque a Membrana del Sistema Complemento/metabolismo , Pruebas Inmunológicas , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/farmacocinética , Síndrome Hemolítico Urémico Atípico/sangre , Síndrome Hemolítico Urémico Atípico/tratamiento farmacológico , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...