Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Magn Reson Med ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767321

RESUMEN

PURPOSE: To improve the spatial resolution and repeatability of a non-contrast MRI technique for simultaneous time resolved 3D angiography and perfusion imaging by developing an efficient 3D cone trajectory design. METHODS: A novel parameterized 3D cone trajectory design incorporating the 3D golden angle was integrated into 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) to achieve higher spatial resolution and sampling efficiency for both dynamic angiography and perfusion imaging with flexible spatiotemporal resolution. Numerical simulations and physical phantom scanning were used to optimize the cone design. Eight healthy volunteers were scanned to compare the original radial trajectory in 4D CAPRIA with our newly designed cone trajectory. A locally low rank reconstruction method was used to leverage the complementary k-space sampling across time. RESULTS: The improved sampling in the periphery of k-space obtained with the optimized 3D cone trajectory resulted in improved spatial resolution compared with the radial trajectory in phantom scans. Improved vessel sharpness and perfusion visualization were also achieved in vivo. Less dephasing was observed in the angiograms because of the short TE of our cone trajectory and the improved k-space sampling efficiency also resulted in higher repeatability compared to the original radial approach. CONCLUSION: The proposed 3D cone trajectory combined with 3D golden angle ordering resulted in improved spatial resolution and image quality for both angiography and perfusion imaging and could potentially benefit other applications that require an efficient sampling scheme with flexible spatial and temporal resolution.

2.
Magn Reson Med ; 92(2): 469-495, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38594906

RESUMEN

Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision-making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi-timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post-labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi-timepoint data can be acquired in the same scan time as single-PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single-PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi-timepoint ASL and provides robust recommendations for acquiring high-quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi-timepoint ASL data. Furthermore, we review the potential clinical applications where multi-timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.


Asunto(s)
Encéfalo , Circulación Cerebrovascular , Marcadores de Spin , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión
4.
Commun Med (Lond) ; 4(1): 38, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499690

RESUMEN

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a familial cardiac disease associated with ventricular arrhythmias and an increased risk of sudden cardiac death. Currently, there are no approved treatments that address the underlying genetic cause of this disease, representing a significant unmet need. Mutations in Plakophilin-2 (PKP2), encoding a desmosomal protein, account for approximately 40% of ARVC cases and result in reduced gene expression. METHODS: Our goal is to examine the feasibility and the efficacy of adeno-associated virus 9 (AAV9)-mediated restoration of PKP2 expression in a cardiac specific knock-out mouse model of Pkp2. RESULTS: We show that a single dose of AAV9:PKP2 gene delivery prevents disease development before the onset of cardiomyopathy and attenuates disease progression after overt cardiomyopathy. Restoration of PKP2 expression leads to a significant extension of lifespan by restoring cellular structures of desmosomes and gap junctions, preventing or halting decline in left ventricular ejection fraction, preventing or reversing dilation of the right ventricle, ameliorating ventricular arrhythmia event frequency and severity, and preventing adverse fibrotic remodeling. RNA sequencing analyses show that restoration of PKP2 expression leads to highly coordinated and durable correction of PKP2-associated transcriptional networks beyond desmosomes, revealing a broad spectrum of biological perturbances behind ARVC disease etiology. CONCLUSIONS: We identify fundamental mechanisms of PKP2-associated ARVC beyond disruption of desmosome function. The observed PKP2 dose-function relationship indicates that cardiac-selective AAV9:PKP2 gene therapy may be a promising therapeutic approach to treat ARVC patients with PKP2 mutations.


Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a heart disease that leads to abnormal heartbeats and a higher risk of sudden cardiac death. ARVC is often caused by changes in a gene called PKP2, that then makes less PKP2 protein. PKP2 protein is important for the normal structure and function of the heart. Human ARVC characteristics can be mimicked in a mouse model missing this gene. Given no therapeutic option, our goal was to test if adding a working copy of PKP2 gene in the heart of this mouse model, using a technique called gene therapy that can deliver genes to cells, could improve heart function. Here, we show that a single dose of PKP2 gene therapy can improve heart function and heartbeats as well as extend lifespan in mice. PKP2 gene therapy may be a promising approach to treat ARVC patients with PKP2 mutations.

5.
Magn Reson Med ; 92(2): 836-852, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38502108

RESUMEN

PURPOSE: Arterial spin labeling (ASL) is a widely used contrast-free MRI method for assessing cerebral blood flow (CBF). Despite the generally adopted ASL acquisition guidelines, there is still wide variability in ASL analysis. We explored this variability through the ISMRM-OSIPI ASL-MRI Challenge, aiming to establish best practices for more reproducible ASL analysis. METHODS: Eight teams analyzed the challenge data, which included a high-resolution T1-weighted anatomical image and 10 pseudo-continuous ASL datasets simulated using a digital reference object to generate ground-truth CBF values in normal and pathological states. We compared the accuracy of CBF quantification from each team's analysis to the ground truth across all voxels and within predefined brain regions. Reproducibility of CBF across analysis pipelines was assessed using the intra-class correlation coefficient (ICC), limits of agreement (LOA), and replicability of generating similar CBF estimates from different processing approaches. RESULTS: Absolute errors in CBF estimates compared to ground-truth synthetic data ranged from 18.36 to 48.12 mL/100 g/min. Realistic motion incorporated into three datasets produced the largest absolute error and variability between teams, with the least agreement (ICC and LOA) with ground-truth results. Fifty percent of the submissions were replicated, and one produced three times larger CBF errors (46.59 mL/100 g/min) compared to submitted results. CONCLUSIONS: Variability in CBF measurements, influenced by differences in image processing, especially to compensate for motion, highlights the significance of standardizing ASL analysis workflows. We provide a recommendation for ASL processing based on top-performing approaches as a step toward ASL standardization.


Asunto(s)
Encéfalo , Circulación Cerebrovascular , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Marcadores de Spin , Humanos , Circulación Cerebrovascular/fisiología , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Masculino , Femenino , Adulto , Algoritmos
6.
Angew Chem Int Ed Engl ; 63(11): e202318879, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38237056

RESUMEN

The extent of the influence that molecular curvature plays on the self-assembly of supramolecular polymers remains an open question in the field. We began addressing this fundamental question with the introduction of "carpyridines", which are saddle-shaped monomers that can associate with one another through π-π interactions and in which the rotational and translational movements are restricted. The topography displayed by the monomers led, previously, to the assembly of highly ordered 2D materials even in the absence of strong directional interactions such as hydrogen bonding. Here, we introduce a simple strategy to gain control over the dimensionality of the formed structures yielding classical unidimensional polymers. These have been characterized using well-established protocols allowing us to determine and confirm the self-assembly mechanism of both fibers and sheets. The calculated interaction energies are significantly higher than expected for flexible self-assembling units lacking classical "strong" non-covalent interactions. The versatility of this supramolecular unit to assemble into either supramolecular fibers or 2D sheets with strong association energies highlights remarkably well the potential and importance of molecular shape for the design of supramolecular materials and the applications thereof.

7.
Nat Commun ; 14(1): 4725, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37550281

RESUMEN

Two-dimensional (2D) materials are a key target for many applications in the modern day. Self-assembly is one approach that can bring us closer to this goal, which usually relies upon strong, directional interactions instead of covalent bonds. Control over less directional forces is more challenging and usually does not result in as well-defined materials. Explicitly incorporating topography into the design as a guiding effect to enhance the interacting forces can help to form highly ordered structures. Herein, we show the process of shape-assisted self-assembly to be consistent across a range of derivatives that highlights the restriction of rotational motion and is verified using a diverse combination of solid state analyses. A molecular curvature governed angle distribution nurtures monomers into loose columns that then arrange to form 2D structures with long-range order observed in both crystalline and soft materials. These features strengthen the idea that shape becomes an important design principle leading towards precise molecular self-assembly and the inception of new materials.

9.
Magn Reson Med ; 89(4): 1323-1341, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36255158

RESUMEN

PURPOSE: Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the SNR improvements from using larger flip angles, made possible by the shorter readout, are quantitatively investigated. METHODS: The SNR of a conventional protocol with nine Look-Locker readouts and a 4 × $$ \times $$ 3 time-encoded protocol with three Look-Locker readouts (giving nine matched timepoints) were compared using simulations and in vivo data. Both protocols were compared using readouts with constant flip angles (CFAs) and variable flip angles (VFAs), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored. RESULTS: The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared with CFAs by 25% and 21% for the conventional and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest that optimizing the background suppression could improve in vivo SNR by a further 16%. CONCLUSIONS: Time encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles, which can double the SNR compared with a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.


Asunto(s)
Imagenología Tridimensional , Angiografía por Resonancia Magnética , Angiografía por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Encéfalo , Marcadores de Spin , Circulación Cerebrovascular/fisiología , Algoritmos
10.
Sci Data ; 9(1): 543, 2022 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-36068231

RESUMEN

Arterial spin labeling (ASL) is a non-invasive MRI technique that allows for quantitative measurement of cerebral perfusion. Incomplete or inaccurate reporting of acquisition parameters complicates quantification, analysis, and sharing of ASL data, particularly for studies across multiple sites, platforms, and ASL methods. There is a strong need for standardization of ASL data storage, including acquisition metadata. Recently, ASL-BIDS, the BIDS extension for ASL, was developed and released in BIDS 1.5.0. This manuscript provides an overview of the development and design choices of this first ASL-BIDS extension, which is mainly aimed at clinical ASL applications. Discussed are the structure of the ASL data, focussing on storage order of the ASL time series and implementation of calibration approaches, unit scaling, ASL-related BIDS fields, and storage of the labeling plane information. Additionally, an overview of ASL-BIDS compatible conversion and ASL analysis software and ASL example datasets in BIDS format is provided. We anticipate that large-scale adoption of ASL-BIDS will improve the reproducibility of ASL research.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Neuroimagen , Humanos , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/normas , Neuroimagen/métodos , Reproducibilidad de los Resultados , Marcadores de Spin
11.
Magn Reson Med ; 88(5): 2021-2042, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35983963

RESUMEN

This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple-timepoint ASL, body ASL, and clinical ASL recommendations.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Circulación Cerebrovascular , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Marcadores de Spin
12.
Magn Reson Med ; 88(4): 1528-1547, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35819184

RESUMEN

This review article provides an overview of the current status of velocity-selective arterial spin labeling (VSASL) perfusion MRI and is part of a wider effort arising from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. Since publication of the 2015 consensus paper on arterial spin labeling (ASL) for cerebral perfusion imaging, important advancements have been made in the field. The ASL community has, therefore, decided to provide an extended perspective on various aspects of technical development and application. Because VSASL has the potential to become a principal ASL method because of its unique advantages over traditional approaches, an in-depth discussion was warranted. VSASL labels blood based on its velocity and creates a magnetic bolus immediately proximal to the microvasculature within the imaging volume. VSASL is, therefore, insensitive to transit delay effects, in contrast to spatially selective pulsed and (pseudo-) continuous ASL approaches. Recent technical developments have improved the robustness and the labeling efficiency of VSASL, making it a potentially more favorable ASL approach in a wide range of applications where transit delay effects are of concern. In this review article, we (1) describe the concepts and theoretical basis of VSASL; (2) describe different variants of VSASL and their implementation; (3) provide recommended parameters and practices for clinical adoption; (4) describe challenges in developing and implementing VSASL; and (5) describe its current applications. As VSASL continues to undergo rapid development, the focus of this review is to summarize the fundamental concepts of VSASL, describe existing VSASL techniques and applications, and provide recommendations to help the clinical community adopt VSASL.


Asunto(s)
Circulación Cerebrovascular , Angiografía por Resonancia Magnética , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Perfusión , Marcadores de Spin
13.
Nat Commun ; 13(1): 3681, 2022 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-35760814

RESUMEN

Self-assembly and molecular recognition are critical processes both in life and material sciences. They usually depend on strong, directional non-covalent interactions to gain specificity and to make long-range organization possible. Most supramolecular constructs are also at least partially governed by topography, whose role is hard to disentangle. This makes it nearly impossible to discern the potential of shape and motion in the creation of complexity. Here, we demonstrate that long-range order in supramolecular constructs can be assisted by the topography of the individual units even in the absence of highly directional interactions. Molecular units of remarkable simplicity self-assemble in solution to give single-molecule thin two-dimensional supramolecular polymers of defined boundaries. This dramatic example spotlights the critical function that topography can have in molecular assembly and paves the path to rationally designed systems of increasing sophistication.

14.
Magn Reson Med ; 87(6): 2667-2684, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35061920

RESUMEN

PURPOSE: Spatially selective arterial spin labeling (ASL) perfusion MRI is sensitive to arterial transit times (ATT) that can result in inaccurate perfusion quantification when ATTs are long. Velocity-selective ASL is robust to this effect because blood is labeled within the imaging region, allowing immediate label delivery. However, velocity-selective ASL cannot characterize ATTs, which can provide important clinical information. Here, we introduce a novel pulse sequence, called VESPA ASL, that combines velocity-selective and pseudo-continuous ASL to simultaneously label different pools of arterial blood for robust cerebral blood flow (CBF) and ATT measurement. METHODS: The VESPA ASL sequence is similar to velocity-selective ASL, but the velocity-selective labeling is made spatially selective, and pseudo-continuous ASL is added to fill the inflow time. The choice of inflow time and other sequence settings were explored. VESPA ASL was compared to multi-delay pseudo-continuous ASL and velocity-selective ASL through simulations and test-retest experiments in healthy volunteers. RESULTS: VESPA ASL is shown to accurately measure CBF in the presence of long ATTs, and ATTs < TI can also be measured. Measurements were similar to established ASL techniques when ATT was short. When ATT was long, VESPA ASL measured CBF more accurately than multi-delay pseudo-continuous ASL, which tended to underestimate CBF. CONCLUSION: VESPA ASL is a novel and robust approach to simultaneously measure CBF and ATT and offers important advantages over existing methods. It fills an important clinical need for noninvasive perfusion and transit time imaging in vascular diseases with delayed arterial transit.


Asunto(s)
Circulación Cerebrovascular , Imagen por Resonancia Magnética , Arterias/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Circulación Cerebrovascular/fisiología , Humanos , Imagen por Resonancia Magnética/métodos , Perfusión , Marcadores de Spin
15.
Angew Chem Int Ed Engl ; 61(10): e202116897, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34995402

RESUMEN

New strategies for synthesizing polyyne polyrotaxanes are being developed as an approach to stable carbyne "insulated molecular wires". Here we report an active metal template route to polyyne [3]rotaxanes, using dicobalt carbonyl masked alkyne equivalents. We synthesized two [3]rotaxanes, both with the same C28 polyyne dumbbell component, one with a phenanthroline-based macrocycle and one using a 2,6-pyridyl cycloparaphenylene nanohoop. The thermal stabilities of the two rotaxanes were compared with that of the naked polyyne dumbbell in decalin at 80 °C, and the nanohoop rotaxane was found to be 4.5 times more stable.

16.
Magn Reson Med ; 86(4): 2208-2219, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34009682

RESUMEN

PURPOSE: Previously, multi- post-labeling delays (PLD) pseudo-continuous arterial spin labeling (pCASL) protocols have been optimized for the estimation accuracy of the cerebral blood flow (CBF) with/without the arterial transit time (ATT) under a standard kinetic model and a normal ATT range. This study aims to examine the estimation errors of these protocols under the effects of macrovascular contamination, flow dispersion, and prolonged arrival times, all of which might differ substantially in elderly or pathological groups. METHODS: Simulated data for four protocols with varying degrees of arterial blood volume (aBV), flow dispersion, and ATTs were fitted with different kinetic models, both with and without explicit correction for macrovascular signal contamination (MVC), to obtain CBF and ATT estimates. Sensitivity to MVC was defined and calculated when aBV > 0.5%. A previously acquired dataset was retrospectively analyzed to compare with simulation. RESULTS: All protocols showed underestimation of CBF and ATT in the prolonged ATT range. With MVC, the protocol optimized for CBF only (CBFopt) had the lowest sensitivity value to MVC, 33.47% and 60.21% error per 1% aBV in simulation and in vivo, respectively, among multi-PLD protocols. All multi-PLD protocols showed a significant decrease in estimation error when an extended kinetic model was used. Increasing flow dispersion at short ATTs caused increasing CBF and ATT overestimation in all protocols. CONCLUSION: CBFopt was the least sensitive protocol to prolonged ATT and MVC for CBF estimation while maintaining reasonably good performance in estimating ATT. Explicitly including a macrovascular component in the kinetic model was shown to be a feasible approach in controlling for MVC.


Asunto(s)
Circulación Cerebrovascular , Imagen por Resonancia Magnética , Anciano , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Marcadores de Spin
17.
Neuroimage ; 223: 117246, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32853814

RESUMEN

Arterial Spin Labeling (ASL) is a non-invasive, non-contrast, perfusion imaging technique which is inherently SNR limited. It is, therefore, important to carefully design scan protocols to ensure accurate measurements. Many pseudo-continuous ASL (PCASL) protocol designs have been proposed for measuring cerebral blood flow (CBF), but it has not yet been demonstrated which design offers the most accurate and repeatable CBF measurements. In this study, a wide range of literature PCASL protocols were first optimized for CBF accuracy and then compared using Monte Carlo simulations and in vivo experiments. The protocols included single-delay, sequential and time-encoded multi-timepoint protocols, and several novel protocol designs, which are hybrids of time-encoded and sequential multi-timepoint protocols. It was found that several multi-timepoint protocols produced more confident, accurate, and repeatable CBF estimates than the single-delay protocol, while also generating maps of arterial transit time. Of the literature protocols, the time-encoded protocol with T1-adjusted label durations gave the most confident and accurate CBF estimates in vivo (16% and 40% better than single-delay), while the sequential multi-timepoint protocol was the most repeatable (20% more repeatable than single-delay). One of the novel hybrid protocols, HybridT1-adj, was found to produce the most confident, accurate and repeatable CBF estimates out of all the protocols tested in both simulations and in vivo (24%, 47%, and 28% more confident, accurate, and repeatable than single-delay in vivo). The HybridT1-adj protocol makes use of the best aspects of both time-encoded and sequential multi-timepoint protocols and should be a useful tool for accurately and efficiently measuring CBF.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Adulto , Femenino , Humanos , Masculino , Método de Montecarlo , Reproducibilidad de los Resultados , Marcadores de Spin , Adulto Joven
18.
Vet Rec ; 185(17): 543, 2019 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-31676621
19.
Magn Reson Med ; 81(4): 2474-2488, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30588656

RESUMEN

PURPOSE: Arterial spin labeling (ASL) MRI is a non-invasive perfusion imaging technique that is inherently SNR limited, so scan protocols ideally need to be rigorously optimized to provide the most accurate measurements. A general framework is presented for optimizing ASL experiments to achieve optimal accuracy for perfusion estimates and, if required, other hemodynamic parameters, within a fixed scan time. The effectiveness of this framework is then demonstrated by optimizing the post-labeling delays (PLDs) of a multi-PLD pseudo-continuous ASL experiment and validating the improvement using simulations and in vivo data. THEORY AND METHODS: A simple framework is proposed based on the use of the Cramér-Rao lower bound to find the protocol design which minimizes the predicted parameter estimation errors. Protocols were optimized for cerebral blood flow (CBF) accuracy or both CBF and arterial transit time (ATT) accuracy and compared to a conventional multi-PLD protocol, with evenly spaced PLDs, and a single-PLD protocol, using simulations and in vivo experiments in healthy volunteers. RESULTS: Simulations and in vivo data agreed extremely well with the predicted performance of all protocols. For the in vivo experiments, optimizing for just CBF resulted in a 48% and 15% decrease in CBF errors, relative to the reference multi-PLD and single-PLD protocols, respectively. Optimizing for both CBF and ATT reduced CBF errors by 37%, without a reduction in ATT accuracy, relative to the reference multi-PLD protocol. CONCLUSION: The presented framework can effectively design ASL experiments to minimize measurement errors based on the requirements of the scan.


Asunto(s)
Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Hemodinámica , Imagen por Resonancia Magnética/métodos , Marcadores de Spin , Adulto , Algoritmos , Encéfalo/irrigación sanguínea , Simulación por Computador , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Método de Montecarlo , Reproducibilidad de los Resultados , Adulto Joven
20.
Pharmacotherapy ; 37(5): 546-554, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28349575

RESUMEN

STUDY OBJECTIVE: To determine whether postoperative administration of low-dose intravenous naloxone decreases the incidence of postoperative nausea and vomiting (PONV) and its impact on postoperative opioid requirements and pain scores. DESIGN: Meta-analysis of nine randomized controlled trials. PATIENTS: A total of 946 adult and pediatric patients who received low-dose intravenous naloxone for 24 hours after various surgeries. MEASUREMENTS AND MAIN RESULTS: Systemic literature searches of the Cochrane Central Register of Controlled Trials, Evidence-Based Medicine Reviews, PubMed, and Ovid MEDLINE databases were conducted. Among the relevant studies, data extraction and bias assessment determined the trials for inclusion in this meta-analysis. Nine randomized controlled trials met inclusion criteria. Naloxone demonstrated a reduced risk of postoperative nausea (risk ratio [RR] 0.80, 95% confidence interval [CI] 0.67-0.95, p=0.01) in a pooled analysis of eight of the nine studies. However, naloxone did not decrease the risk of postoperative vomiting in a collective assessment of all nine trials (RR 0.83, 95% CI 0.63-1.09, p=0.18). Subgroup analysis of continuous-infusion naloxone found further reductions in nausea and vomiting, but these findings were limited to 186 of the 946 patients. Three studies recorded antiemetic doses and found an overall dose reduction (RR 0.64, 95% CI 0.42-0.96, p=0.03). Compared with controls, naloxone prophylaxis of PONV did not significantly change cumulative postoperative opioid needs (mean difference 0.29 mg, 95% CI -3.55 to 4.13 mg, p=0.88) among five trials, nor visual analog scale pain scores (mean difference -0.11, 95% CI -0.26 to 0.05, p=0.18) in six studies. CONCLUSION: This pooled analysis of data suggests that low-dose naloxone plays no role in preventing PONV, while exhibiting no significant effects on postoperative opioid needs and pain scores. The reduction demonstrated in postoperative nausea did not translate into decreases in postoperative vomiting.


Asunto(s)
Naloxona/administración & dosificación , Antagonistas de Narcóticos/administración & dosificación , Dolor Postoperatorio/prevención & control , Náusea y Vómito Posoperatorios/prevención & control , Profilaxis Pre-Exposición/métodos , Analgésicos Opioides/administración & dosificación , Humanos , Infusiones Intravenosas , Morfina/administración & dosificación , Dolor Postoperatorio/epidemiología , Náusea y Vómito Posoperatorios/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...