Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Membranes (Basel) ; 14(6)2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38921489

RESUMEN

The commercial ultrafiltration polyethersulfone (PES) membranes (10 and 100 kDa) blended with polyvinylpyrrolidone (PVP) were applied for the filtration of car wash wastewater. Periodical membrane rinsing with water did not prevent fouling and a decrease in permeate flux was observed. Fouling was reduced by washing the membranes with cleaning agents, which are used in car washes to clean wheels and remove insects. In addition to surfactants, these agents contain NaOH, hence the pH value of cleaning solutions was over 11. Long-term contact with such solutions resulted in the removal of PVP from the membrane matrix and an increase in pore size. The PES membranes were soaked in an alkaline solution (pH = 11.5) for 20 months, after which the 200 kDa dextran rejection decreased from 95% to 80%. To compare with the static degradation conditions, 8 weeks of alkaline agent filtration was realized, after which the dextran (200 kDa) rejection decreased below 50%. This indicated that the cross-flow of alkaline agents can accelerate the removal of components building the membrane matrix. Despite membrane degradation, the separation efficiency (the rejection of chemical oxygen demand-COD, turbidity, and surfactants) during the treatment of synthetic car wash wastewater was similar to that obtained for pristine membranes.

2.
Membranes (Basel) ; 14(2)2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38392654

RESUMEN

Polyethersulfone (PES) is a polymer popularly used to produce ultrafiltration (UF) membranes. PES is relatively hydrophobic; thus, hydrophilic ingredients are added to the membrane matrix to reduce the fouling intensity. Ingredients such as polyvinylpyrrolidone (PVP) reduce the resistance of PES to NaOH solutions. This study investigated the possibility of using PES membranes for the separation of alkaline cleaning solutions. For this purpose, self-made PES membranes and commercial ultrafiltration PES membranes (UE10-10 kDa and UE50-100 kDa) containing PVP additive were used. The membranes were soaked for 18 months in alkaline (pH = 11.3-11.5) solutions of car washing fluids. It has been found that long-term contact with these solutions caused changes in the structure of the surface layer, especially of membranes containing PVP. As a result, the separation of dextran (100-200 kDa) decreased by 30-40% for PES membranes, 30-40% for UE10 and 40-60% for UE50. Despite these changes, the separation efficiency (rejection of COD, NTU and anionic surfactants) of synthetic car wash wastewater (mixture of surfactants and hydrowax) was similar to the results obtained for pristine membranes.

3.
Sensors (Basel) ; 23(13)2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37447982

RESUMEN

The article presents an algorithm for the multi-domain visual recognition of an indoor place. It is based on a convolutional neural network and style randomization. The authors proposed a scene classification mechanism and improved the performance of the models based on synthetic and real data from various domains. In the proposed dataset, a domain change was defined as a camera model change. A dataset of images collected from several rooms was used to show different scenarios, human actions, equipment changes, and lighting conditions. The proposed method was tested in a scene classification problem where multi-domain data were used. The basis was a transfer learning approach with an extension style applied to various combinations of source and target data. The focus was on improving the unknown domain score and multi-domain support. The results of the experiments were analyzed in the context of data collected on a humanoid robot. The article shows that the average score was the highest for the use of multi-domain data and data style enhancement. The method of obtaining average results for the proposed method reached the level of 92.08%. The result obtained by another research team was corrected.


Asunto(s)
Robótica , Algoritmos , Aprendizaje , Iluminación , Redes Neurales de la Computación
4.
Phys Eng Sci Med ; 46(2): 897-902, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37185808

RESUMEN

Quality control in mammography is a very important element. One of the parameters indicating the appropriate image quality is the threshold image contrast. The CDMAM phantom is used to measure this parameter. It is currently available in two versions 3.4 and 4.0. The aim of this work is to compare the threshold image contrast readings obtained with the CDMAM 3.4 and CDMAM 4.0 phantoms. In the measurements, 9 CDMAM 4.0 phantoms were used to check the difference in indications of individual copies. The phantom whose readings were closest to the average of all readings was used for comparative measurements with the CDMAM 3.4 phantom. Measurements were made on 40 mammography devices. The obtained images were read with the software provided by the phantom manufacturer and the CDMAM Analysis v2.3.0 (NCCPM) software. The average percentage difference between the minimum and maximum values indicated by the CDMAM 4.0 phantoms was 10.09%. Using the CDMAM Analysis v2.3.0 (NCCPM) software, the average difference in readings between the CDMAM 3.4 and CDMAM 4.0 phantoms is 7.93%, and when using the software provided by the phantom manufacturer, it is as much as 60.15%. The obtained results of the threshold image contrast are affected by the type of software used for reading and the accuracy of the execution of individual elements of the phantom. It is recommended to use CDMAM Analysis v2.3.0 (NCCPM) software or the latest software provided by the phantom manufacturer to read the phantom images.


Asunto(s)
Mamografía , Intensificación de Imagen Radiográfica , Intensificación de Imagen Radiográfica/métodos , Programas Informáticos , Fantasmas de Imagen , Control de Calidad
5.
Membranes (Basel) ; 13(1)2023 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-36676887

RESUMEN

In the present study, the membrane distillation (MD) process was studied with the use of commercial polytetrafluoroethylene (PTFE) capillary membranes. For this purpose, both solutions with NaCl concentrations up to 300 g/L and brines contaminated with oil (70-120 mg/L) were used as feeds. The membrane's wetting resistance was tested by conducting long-term experiments for over 3500 h. Using detailed studies, it has been shown that increasing the salt concentration from 35 to 300 g/L resulted in a 50% reduction in the permeate flux. Nevertheless, the membranes retained 100% of the salt rejection after 2000 h of the module's operation. Moreover, it has been found that performing the MD process with brines contaminated with oil (120 mg/L) led to the wetting of some membranes pores, which it turn resulted in an increase in the distillate's conductivity to 450 µS/cm after 700 h running the process. The mechanism of pore wetting by oil droplets adsorbed on the membrane's surface was presented. Finally, the proposed method of membrane cleaning with the use of a solvent allowed restoring the initial MD module's performance. Consequently, both the permeate flux and distillate conductivity were stable during the MD of the feed containing 35 g/L of NaCl over the next 280 h.

6.
Radiol Oncol ; 55(2): 212-220, 2021 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-33600676

RESUMEN

BACKGROUND: Patients with left breast cancer who undergo radiotherapy have a non-negligible risk of developing radiation-induced cardiovascular disease (CVD). Cardioprotection can be achieved through better treatment planning protocols and through respiratory gating techniques, including deep inspiration breath hold (DIBH). Several dosimetric studies have shown that DIBH reduces the cardiac dose, but clinical data confirming this effect is limited. The aim of the study was to compare the mean heart dose (MHD) in patients with left breast cancer who underwent radiotherapy at our institution as we transitioned from non-gated free-breathing (FB) radiotherapy to gated radiotherapy (FB-GRT), and finally to DIBH. PATIENTS AND METHODS: Retrospective study involving 2022 breast cancer patients who underwent radiotherapy at West Pomeranian Oncology Center in Szczecin from January 1, 2014 through December 31, 2017. We compared the MHD in these patients according to year of treatment and technique. RESULTS: Overall, the MHD for patients with left breast cancer in our cohort was 3.37 Gy. MHD values in the patients treated with DIBH were significantly lower than in patients treated with non-gated FB (2.1 vs. 3.48 Gy, p < 0.0001) and gated FB (3.28 Gy, p < 0.0001). The lowest MHD values over the four-year period were observed in 2017, when nearly 85% of left breast cancer patients were treated with DIBH. The proportion of patients exposed to high (> 4 Gy) MHD values decreased every year, from 40% in 2014 to 7.9% in 2017, while the percentage of patients receiving DIBH increased. CONCLUSIONS: Compared to free-breathing techniques (both gated and non-gated), DIBH reduces the mean radiation dose to the heart in patients with left breast cancer. These findings support the use of DIBH in patients with left breast cancer treated with radiotherapy.


Asunto(s)
Contencion de la Respiración , Corazón/efectos de la radiación , Inhalación , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/prevención & control , Neoplasias de Mama Unilaterales/radioterapia , Intervalos de Confianza , Femenino , Humanos , Dosis de Radiación , Radioterapia de Intensidad Modulada/tendencias , Estudios Retrospectivos , Factores de Tiempo
7.
Int J Infect Dis ; 104: 239-241, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33359672

RESUMEN

Cowpox is a rare zoonosis transmitted to humans mainly from cats. The disease usually causes skin lesions; however, the ocular form may lead to other serious complications. We describe a case of cowpox in a rare location of the upper eyelid of an immunocompetent male, which lead to necrosis of the upper eyelid, keratitis and leucomatous opacity, and the neovascularization of the cornea. The patient underwent several surgeries, including reconstruction surgery of the eyelids, correction of the medial canthus, and corneal neurotization with supraorbicular nerve transplantation. Suspicion of cowpox should be made in patients where there are poorly healing skin lesions accompanied by a painful black eschar with erythema and local lymphadenopathy. Ocular cowpox may lead to serious complications and possibly mimic anthrax. Diagnosis of cowpox can be confirmed by detection of cowpox virus DNA by polymerase chain reaction. Patients should be advised to protect themselves while handling sick animals.


Asunto(s)
Virus de la Viruela Vacuna/aislamiento & purificación , Viruela Vacuna/diagnóstico , Párpados/virología , Adulto , Animales , Carbunco/diagnóstico , Gatos , Viruela Vacuna/patología , Viruela Vacuna/transmisión , ADN Viral/aislamiento & purificación , Diagnóstico Diferencial , Párpados/patología , Párpados/cirugía , Humanos , Masculino , Necrosis/diagnóstico , Reacción en Cadena de la Polimerasa , Procedimientos de Cirugía Plástica/métodos , Piel/patología , Zoonosis/diagnóstico , Zoonosis/transmisión
8.
Pulse (Basel) ; 9(3-4): 83-88, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35083174

RESUMEN

INTRODUCTION: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on cardiovascular health, as well as to assess whether high signal resolution (HSR) pulse oximetry could be used as a prognostic indicator of radiotherapy toxicity. METHODS: A total of 19 patients treated with radiotherapy to the lung or left breast were analyzed. Pulse oximetry was performed on all eligible patients (before and after the administration of a radiation dose) using the PULS-HSR program, which increases the resolution of the pulse wave recording. RESULTS: Among the analyzed variables, we found the total dose administered to the target, as well as the treatment duration, significantly positively correlated with the change in ventricle/aorta volume ratio. The ventricle/aorta volume ratio parameter is the ratio between the area under the HSR pulse wave generated by the contraction of the left ventricle until the aortic valve closes and the area of the HSR pulse wave responsible for expansion and contraction of the aorta. CONCLUSION: The pilot study indicates HSR pulse oximetry, especially the ventricle/aorta volume ratio parameter, as a potential prognostic indicator of toxicity from radiation for breast and lung cancers.

9.
Rep Pract Oncol Radiother ; 26(6): 899-905, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34992861

RESUMEN

BACKGROUND: The present paper reports on analysis of 184 patients who were diagnosed with endometrial cancer. The main objective of this study was to address parameter Vrec(30Gy) which determines a volume of the rectum irradiated with a dose of 30 Gy during radiotherapy. MATERIALS AND METHODS: All patients were irradiated with an IMRT technique on linear accelerators. The planning target volume (PTV) contour was determined by a radiation oncologist. The clinical target volume (CTV) was drawn on CT images obtained in a prone position. For statistical analysis, appropriate tests (e.g. the Shapiro-Wilk, Wilcoxon) were used. RESULTS AND DISCUSSION: The performed analysis showed that the recommended condition for Vrec(30Gy) is met only in 3% of patients and the observed median value exceeds 90%. The obtained results were compared with the studies in which the Vrec(30Gy) values were related to various radiotherapy techniques. CONCLUSIONS: The analysis showed that the condition for Vrec(30Gy) is satisfied in the case of only 3% of patients. Due to the difficulty with meeting the condition, it should be reconsidered based on real results.

10.
IDCases ; 21: e00798, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32461903

RESUMEN

Many species of microorganisms of various human pathogenicity have been identified in the oral cavities of dogs and cats. One of them is Capnocytophaga canimorsus, a Gram-negative bacterium of the Flavobacteriacae family, with unique abilities to forage sugars from host tissues and avoid the host immune response. Although C. canimorsus may be isolated from the oral cavities of most dogs and cats, severe human infection is very rare according to studies (0.67 cases/million/year). A canine or feline bite is the most common source of infection. At the highest risk are asplenic or functionally asplenic patients as well as individuals with cirrhosis or a history of alcohol abuse. We report a fatal case of C. canimorsus sepsis in a patient with a spleen.

11.
J Ophthalmol ; 2018: 4691417, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30155282

RESUMEN

PURPOSE: This randomized, observer-masked, crossover study investigated the effect of two hyaluronic acid/trehalose-based containing formulations, with different physical properties, on the signs and symptoms in patients with moderate to severe dry eye disease (DED). METHODS: In one group, patients received a mixture of sodium hyaluronate and trehalose (HT, Thealoz Duo®) for use during the day. In the other group, patients received a more viscous formulation consisting of hyaluronic acid, trehalose, and carbomer (HTC-gel, Thealoz Duo Gel) to use pro re nata. Both groups used HTC-gel before going to bed. Clinical standard tests for DED were performed at the beginning and end of each one-week period. Further, patient satisfaction including quality of sleep was assessed using a visual analogue scale. RESULTS: Corneal fluorescein and conjunctival lissamine green staining scores decreased, and tear breakup time (BUT) increased for both groups (p < 0.001 each). Mean instillation frequency was 3.1 ± 2.6 drops/day when using HT and 1.9 ± 2.2 drops/day when using HTC-gel (p=0.02). A significant improvement in the quality of sleep was observed with both treatments (p=0.01). CONCLUSIONS: Our results show improvement in signs and symptoms of DED in both groups. While instillation of HTC-gel resulted in a lower instillation frequency, both formulations of trehalose showed good clinical efficacy. This trial is registered with NCT02980913.

12.
Br J Ophthalmol ; 102(12): 1679-1683, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29472236

RESUMEN

BACKGROUND/AIMS: There is considerable interest in novel techniques to quantify choroidal blood flow (CBF) in humans. In the present study, we investigated a novel technique to measure CBF based on laser speckle flowgraphy (LSFG) in healthy subjects. METHODS: This study included 31 eyes of 31 healthy, non-smoking subjects aged between 19 and 74 years. A commercial LSFG instrument was used to measure choroidal vessel diameter (CVD) and relative flow volume (RFV) in choroidal vessels that were identified on fundus photos, an approach that was used previously only for retinal vessels. The reproducibility and the effect of isometric exercise on these parameters were investigated. The latter was compared with measurement of subfoveal CBF using laser Doppler flowmetry (LDF). RESULTS: Intraclass correlation coefficients for CVD and RFV were higher than 0.8 indicating excellent reproducibility. During isometric exercise, we observed an increase in ocular perfusion pressure of approximately 60% (P<0.001). The increase in RFV and CBF was lower, but also highly significant versus baseline (at minute 6 of isometric exercise: RFV 10.5%±4.2%, CBF 8.3%±3.6%; P<0.001 each) indicating choroidal autoregulation. CONCLUSION: LSFG may be a novel approach to study blood flow in choroidal vessels. Data are reproducible and show good agreement with LDF data. TRIAL REGISTRATION NUMBER: NCT02102880, Results.


Asunto(s)
Coroides/irrigación sanguínea , Flujometría por Láser-Doppler , Flujo Sanguíneo Regional/fisiología , Adolescente , Adulto , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Ejercicio Físico/fisiología , Femenino , Voluntarios Sanos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
13.
Oxid Med Cell Longev ; 2017: 8023935, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29147464

RESUMEN

Long-term fluoroquinolone-associated disability (FQAD) after fluoroquinolone (FQ) antibiotic therapy appears in recent years as a significant medical and social problem, because patients suffer for many years after prescribed antimicrobial FQ treatment from tiredness, concentration problems, neuropathies, tendinopathies, and other symptoms. The knowledge about the molecular activity of FQs in the cells remains unclear in many details. The effective treatment of this chronic state remains difficult and not effective. The current paper reviews the pathobiochemical properties of FQs, hints the directions for further research, and reviews the research concerning the proposed treatment of patients. Based on the analysis of literature, the main directions of possible effective treatment of FQAD are proposed: (a) reduction of the oxidative stress, (b) restoring reduced mitochondrion potential ΔΨm,


Asunto(s)
Antibacterianos , Fluoroquinolonas , Potencial de la Membrana Mitocondrial/efectos de los fármacos , Enfermedades Mitocondriales , Estrés Oxidativo/efectos de los fármacos , Antibacterianos/efectos adversos , Antibacterianos/uso terapéutico , Fluoroquinolonas/efectos adversos , Fluoroquinolonas/uso terapéutico , Humanos , Enfermedades Mitocondriales/inducido químicamente , Enfermedades Mitocondriales/metabolismo , Enfermedades Mitocondriales/patología , Enfermedades Mitocondriales/terapia
14.
Invest Ophthalmol Vis Sci ; 58(12): 5022-5029, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28973374

RESUMEN

Purpose: To investigate the effects of intravitreal 0.7 mg dexamethasone implants (Ozurdex) on arterial and venous oxygen saturation, retinal vessel diameter, and retrobulbar blood flow velocity in patients with macular edema (ME) due to retinal vein occlusion (RVO). Methods: This prospective, nonrandomized clinical trial included 40 eyes of 40 patients with ME due to RVO. Measurements of arterial and venous oxygen saturation and retinal vessel diameters were performed using the Dynamic Vessel Analyzer. The main outcome measure was the retinal arteriovenous oxygen difference, calculated as the difference between arterial and venous oxygenation. Color Doppler imaging was performed for measuring peak systolic velocity (PSV), end diastolic velocity (EDV), and resistive index (RI) in ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary arteries (PCAs). Follow-up was monthly for 6 months following an initial dexamethasone implant injection. As statistical analysis, a mixed model was performed to investigate the effect treatment. Results: The arteriovenous oxygen difference showed a significant increase (P < 0.01). Arterial oxygenation and vessel diameter did not respond to the treatment (P > 0.05), while the venous oxygen saturation and diameter decreased significantly (P < 0.01) compared to baseline. The retrobulbar blood flow velocities PSV, EDV, and RI showed no change in the OA, CRA, and PCA (P > 0.05). Conclusions: In patients with RVO, intravitreal dexamethasone treatment leads to an increase in arteriovenous oxygen saturation difference indicating improved retinal oxygenation. Arterial oxygenation and vessel diameter showed no response, whereas venous oxygenation and vessel diameter decreased after treatment.


Asunto(s)
Antiinflamatorios/farmacología , Dexametasona/farmacología , Edema Macular/tratamiento farmacológico , Oxígeno/metabolismo , Retina/efectos de los fármacos , Oclusión de la Vena Retiniana/tratamiento farmacológico , Vasos Retinianos/efectos de los fármacos , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Implantes de Medicamentos , Femenino , Humanos , Edema Macular/etiología , Edema Macular/metabolismo , Edema Macular/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Flujo Sanguíneo Regional/efectos de los fármacos , Retina/metabolismo , Oclusión de la Vena Retiniana/metabolismo , Oclusión de la Vena Retiniana/fisiopatología , Vasos Retinianos/fisiopatología
15.
PLoS One ; 12(9): e0184772, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28898284

RESUMEN

The aim of the present study was to investigate regulation of blood flow (BF) in the optic nerve head (ONH) and a peripapillary region (PPR) during an isometric exercise-induced increase in ocular perfusion pressure (OPP) using laser speckle flowgraphy (LSFG) in healthy subjects. For this purpose, a total of 27 subjects was included in this study. Mean blur rate in tissue (MT) was measured in the ONH and in a PPR as well as relative flow volume (RFV) in retinal arteries (ART) and veins (VEIN) using LSFG. All participants performed isometric exercise for 6 minutes during which MT and mean arterial pressure were measured every minute. From these data OPP and pressure/flow curves were calculated. Isometric exercise increased OPP, MTONH and MTPRR. The relative increase in OPP (78.5 ± 19.8%) was more pronounced than the increase in BF parameters (MTONH: 18.1 ± 7.7%, MTPRR: 21.1 ± 8.3%, RFVART: 16.5 ±12.0%, RFVVEIN: 17.7 ± 12.4%) indicating for an autoregulatory response of the vasculature. The pressure/flow curves show that MTONH, MTPRR, RFVART, RFVVEIN started to increase at OPP levels of 51.2 ± 2.0%, 58.1 ± 2.4%, 45.6 ± 1.9% and 45.6 ± 1.9% above baseline. These data indicate that ONHBF starts to increase at levels of approx. 50% increase in OPP: This is slightly lower than the values we previously reported from LDF data. Signals from the PPR may have input from both, the retina and the choroid, but the relative contribution is unknown. In addition, retinal BF appears to increase at slightly lower OPP values of approximately 45%. LSFG may be used to study ONH autoregulation in diseases such as glaucoma. TRIAL REGISTRATION: ClinicalTrials.gov NCT02102880.


Asunto(s)
Ejercicio Físico , Nervio Óptico/fisiología , Vasos Retinianos/fisiología , Adolescente , Adulto , Presión Sanguínea , Femenino , Humanos , Contracción Isométrica , Flujometría por Láser-Doppler/métodos , Masculino , Nervio Óptico/diagnóstico por imagen , Flujo Sanguíneo Regional , Vasos Retinianos/diagnóstico por imagen
16.
Diabetologia ; 60(8): 1534-1540, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28547132

RESUMEN

AIMS/HYPOTHESIS: The aim of this study was to compare retinal oxygen extraction in individuals with diabetes with no or mild non-proliferative diabetic retinopathy and healthy age- and sex-matched volunteers. METHODS: A total of 24 participants with type 1 diabetes and 24 healthy age- and sex-matched volunteers were included in this cross-sectional study. Retinal oxygen extraction was measured by combining total retinal blood flow measurements using a custom-built bi-directional Doppler optical coherence tomography system with measurements of oxygen saturation using spectroscopic reflectometry. Based on previously published mathematical modelling, the oxygen content in retinal vessels and total retinal oxygen extraction were calculated. RESULTS: Total retinal blood flow was higher in diabetic participants (46.4 ± 7.4 µl/min) than in healthy volunteers (40.4 ± 5.3 µl/min, p = 0.002 between groups). Oxygen content in retinal arteries was comparable between the two groups, but oxygen content in retinal veins was higher in participants with diabetes (0.15 ± 0.02 ml O2/ml) compared with healthy control participants (0.13 ± 0.02 ml O2/ml, p < 0.001). As such, the arteriovenous oxygen difference and total retinal oxygen extraction were reduced in participants with diabetes compared with healthy volunteers (total retinal oxygen extraction 1.40 ± 0.44 vs 1.70 ± 0.47 µl O2/min, respectively, p = 0.03). CONCLUSIONS/INTERPRETATION: Our data indicate early retinal hypoxia in individuals with type 1 diabetes with no or mild diabetic retinopathy as compared with healthy control individuals. Further studies are required to fully understand the potential of the technique in risk stratification and treatment monitoring. TRIAL REGISTRATION: ClinicalTrials.gov NCT01843114.


Asunto(s)
Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/patología , Retinopatía Diabética/metabolismo , Retinopatía Diabética/patología , Oxígeno/metabolismo , Retina/metabolismo , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Masculino , Flujo Sanguíneo Regional/fisiología , Adulto Joven
17.
Acta Ophthalmol ; 95(4): e307-e313, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27989018

RESUMEN

PURPOSE: To compare the effect of a single drop of different lubricant eye gels on tear film thickness (TFT) as measured with ultrahigh-resolution optical coherence tomography (UHR-OCT) in patients with mild-to-moderate dry eye disease (DED). METHODS: The study followed a randomized, single-masked, observer-blinded parallel group design. Patients received a single dose of either unpreserved trehalose 3% + hyaluronic acid 0.15% (TH), hyaluronic acid 0.2% (HA) or polyethylene glycol 0.4% + propylene glycol 0.3% (PP) eye drops. In total, 60 patients were included and TFT was measured using a custom-built UHR-OCT system. RESULTS: The mean TFT at baseline was 3.5 ± 0.7 µm. There was a significant difference in the time-course of TFT between the three groups (p = 0.001 between groups). Ten minutes after instillation, TFT increased by 155.8 ± 86.6%, 65.7 ± 71.5% and 33.4 ± 19.6% in the PP, TH and HA group, respectively (p < 0.001 between groups). Thirty minutes after instillation, the effect of all three different agents on TFT was comparable. Sixty and 120 min after administration, a significant increase in TFT was only seen for the TH group, but not for the other products (60 min: p < 0.021 between groups; 120 min: p < 0.037 between groups). CONCLUSION: In conclusion, we observed differences in TFT after administration of the lubricant gels. Ten minutes after instillation, a pronounced increase in TFT was observed in all groups. As compared to the other products, the combination of trehalose 3% + hyaluronic acid 0.15% offers a significantly longer increase in TFT indicating for a longer residence time.


Asunto(s)
Síndromes de Ojo Seco/tratamiento farmacológico , Geles/administración & dosificación , Aumento de la Imagen , Lubricantes/administración & dosificación , Lágrimas/química , Tomografía de Coherencia Óptica/métodos , Adulto , Anciano , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/metabolismo , Femenino , Humanos , Ácido Hialurónico/administración & dosificación , Masculino , Persona de Mediana Edad , Soluciones Oftálmicas , Polietilenglicoles/administración & dosificación , Método Simple Ciego , Tensoactivos/administración & dosificación , Lágrimas/efectos de los fármacos , Viscosuplementos/administración & dosificación , Adulto Joven
18.
PLoS One ; 11(12): e0168190, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27959905

RESUMEN

PURPOSE: To assess the feasibility and reliability of Laser Speckle Flowgraphy (LSFG) to measure ocular perfusion in a sample of healthy white subjects and to elucidate the age-dependence of the parameters obtained. METHODS: This cross-sectional study included 80 eyes of 80 healthy, non-smoking white subjects of Western European descent between 19 and 79 years of age. A commercial LSFG instrument was applied to measure ocular blood flow at the optic nerve head (ONH) three successive times before and after pharmacological pupil dilation. The mean blur rate (MBR), a measure of relative blood flow velocity, was obtained for different regions of the ONH. Eight parameters of ocular perfusion derived from the pulse-waveform analysis of MBR including blowout time (BOT) and falling rate (FR) were also recorded. RESULTS: Artifact-free LSFG images meeting the quality criteria for automated image analysis were obtainable in 93.8% without pupil dilation and in 98.8% with pharmacological pupil dilation. Measurements of MBR showed excellent repeatability with intraclass correlation coefficients ≥ 0.937 and were barely affected by pupil dilation. The majority of pulse-waveform derived variables exhibited equally high repeatability. MBR-related blood flow indices exhibited significant age dependence (p<0.001). FR (r = 0.747, p<0.001) and BOT (r = -0.714, p<0.001) most strongly correlated with age. CONCLUSIONS: LSFG represents a reliable method for the quantitative assessment of ocular blood flow in white subjects. Our data affirms that the LSFG-derived variables FR and BOT may be useful biomarkers for age-related changes in ocular perfusion.


Asunto(s)
Flujometría por Láser-Doppler , Disco Óptico/irrigación sanguínea , Adolescente , Adulto , Factores de Edad , Anciano , Artefactos , Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Estudios Transversales , Femenino , Voluntarios Sanos , Hemodinámica , Humanos , Procesamiento de Imagen Asistido por Computador , Rayos Láser , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Pigmentación , Pupila/fisiología , Flujo Sanguíneo Regional/fisiología , Reproducibilidad de los Resultados , Factores Sexuales , Factores de Tiempo , Población Blanca , Adulto Joven
19.
Invest Ophthalmol Vis Sci ; 57(13): 5417-5425, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27756076

RESUMEN

PURPOSE: This study evaluated the validity of retinal perfusion measurements using laser speckle flowgraphy (LSFG) by means of in vitro experiments and direct comparison with dual-beam Doppler optical coherence tomography (D-OCT) in a healthy Caucasian population. METHODS: The flow velocity of scattering solution pumped through a glass capillary was measured at 17 different flow velocities (range, 0.5-47 mm/s) using LSFG. The flow within the glass capillary was produced by a computer-controlled infusion pump. In vivo, three consecutive LSFG scans were obtained in 20 eyes of 20 healthy Caucasian subjects before and after pharmacological pupil dilation. Relative flow volume (RFV), the primary output parameter of LSFG, was comparatively validated relative to absolute measurements of retinal blood flow and velocity as obtained from D-OCT. RESULTS: In the in vitro experiments, RFV was found to saturate at a level of approximately 700 arbitrary units (au) or 23.5 mm/s of actual velocity. In vivo, RFV was in significant agreement with absolute blood flow measurements as obtained from D-OCT in arteries (r = 0.69, P = 0.001) and veins (r = 0.74, P < 0.001). However, linear regression analysis revealed significant positive zero offset values for RFV of 223.4 and 282.7 au in arteries and veins, respectively. CONCLUSIONS: Measurements of RFV were successfully obtainable, reproducible, and not influenced by pharmacological pupil dilation. Nevertheless, our data revealed flaws in the LSFG method of measuring retinal perfusion in Caucasians. Adjustment to the technique is required to address apparent issues with RFV, especially saturation effects with higher arterial flow rates. The present dataset may provide a valuable tool to do so. (Clinicaltrials.gov number NCT02582411).


Asunto(s)
Flujometría por Láser-Doppler/métodos , Flujo Sanguíneo Regional/fisiología , Vasos Retinianos/fisiología , Tomografía de Coherencia Óptica/métodos , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Vasos Retinianos/diagnóstico por imagen
20.
JAMA Ophthalmol ; 134(10): 1169-1176, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27584715

RESUMEN

IMPORTANCE: Corneal abrasions are frequent after standard (epithelium-off [epi-off]) corneal collagen cross-linking (CXL) in patients with progressive keratoconus. A new matrix therapy agent (ReGeneraTing Agent [RGTA]) has been developed to promote corneal wound healing. OBJECTIVE: To assess the effect of the new type of matrix therapy agent on corneal wound healing after epi-off CXL in patients with keratoconus. DESIGN, SETTING, AND PARTICIPANTS: This double-masked randomized clinical trial enrolled 40 patients with keratoconus undergoing epi-off CXL from July 18, 2014, to October 21, 2015, when the last follow-up was completed. The analysis of the intention-to-treat population was performed at the Department of Clinical Pharmacology in cooperation with the Center for Medical Physics and Biomedical Engineering and the Department of Ophthalmology and Optometry of the Medical University of Vienna. INTERVENTIONS: Patients were randomized to receive the matrix therapy agent or hyaluronic acid-containing eyedrops, 0.1%, every other day starting immediately after surgery. The size of the corneal defect was measured using ultrahigh-resolution optical coherence tomography (OCT) and slitlamp photography (SLP) with fluorescein staining. MAIN OUTCOMES AND MEASURES: Corneal wound healing rate, defined as the size of the defect over time. RESULTS: Among the 40 patients undergoing epi-off CXL (31 men; 9 women; mean [SD] age, 31 [10] years), wound healing was significantly faster in the matrix therapy agent group compared with the hyaluronic acid group (4.4 vs 6.1 days; mean difference, 1.7 days; 95% CI, 0.25-3.15 days; P = .008). The defect size was smaller in the matrix therapy agent group than in the hyaluronic acid group as measured with OCT (12.4 vs 23.9 mm2; mean difference, 11.6 mm2; 95% CI, 0.8-23.5 mm2; P = .045) and SLP (11.9 vs 23.5 mm2; mean difference, 11. 6 mm2; 95% CI, 1.3-22.9 mm2; P = .03). A correlation between the defect size measured with OCT and SLP was found (r = 0.89; P < .001). No ocular or serious adverse events occurred. CONCLUSIONS AND RELEVANCE: Use of a new matrix therapy agent appears to improve corneal wound healing after CXL in patients with keratoconus. Monitoring of corneal wound healing using ultrahigh-resolution OCT might be an attractive alternative to SLP because OCT provides an objective and 3-dimensional evaluation of the corneal defect. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT02119039.


Asunto(s)
Colágeno/uso terapéutico , Reactivos de Enlaces Cruzados/uso terapéutico , Epitelio Corneal/efectos de los fármacos , Queratocono/tratamiento farmacológico , Cicatrización de Heridas/efectos de los fármacos , Adolescente , Adulto , Epitelio Corneal/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Ácido Hialurónico/uso terapéutico , Queratocono/diagnóstico , Masculino , Persona de Mediana Edad , Soluciones Oftálmicas , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Viscosuplementos/uso terapéutico , Agudeza Visual , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...