Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 18 de 18
1.
Article En | MEDLINE | ID: mdl-38508486

OBJECTIVE: Donation after circulatory death (DCD) donors offer the ability to expand the lung donor pool and ex vivo lung perfusion (EVLP) further contributes to this ability by allowing for additional evaluation and resuscitation of these extended criteria donors. We sought to determine the outcomes of recipients receiving organs from DCD EVLP donors in a multicenter setting. METHODS: This was an unplanned post hoc analysis of a multicenter, prospective, nonrandomized trial that took place during 2011 to 2017 with 3 years of follow-up. Patients were placed into 3 groups based off procurement strategy: brain-dead donor (control), brain-dead donor evaluated by EVLP, and DCD donors evaluated by EVLP. The primary outcomes were severe primary graft dysfunction at 72 hours and survival. Secondary outcomes included select perioperative outcomes, and 1-year and 3-years allograft function and quality of life measures. RESULTS: The DCD EVLP group had significantly higher incidence of severe primary graft dysfunction at 72 hours (P = .03), longer days on mechanical ventilation (P < .001) and in-hospital length of stay (P = .045). Survival at 3 years was 76.5% (95% CI, 69.2%-84.7%) for the control group, 68.3% (95% CI, 58.9%-79.1%) for the brain-dead donor group, and 60.7% (95% CI, 45.1%-81.8%) for the DCD group (P = .36). At 3-year follow-up, presence observed bronchiolitis obliterans syndrome or quality of life metrics did not differ among the groups. CONCLUSIONS: Although DCD EVLP allografts might not be appropriate to transplant in every candidate recipient, the expansion of their use might afford recipients stagnant on the waitlist a viable therapy.

2.
3.
Artif Organs ; 41(5): 424-430, 2017 May.
Article En | MEDLINE | ID: mdl-27782305

Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs.


Arterial Pressure , Blood Pressure Determination/methods , Heart-Assist Devices , Oximetry/methods , Adult , Female , Humans , Male , Middle Aged , Prospective Studies , Ultrasonography, Doppler/methods
4.
Ann Transl Med ; 4(11): 220, 2016 Jun.
Article En | MEDLINE | ID: mdl-27386494

A 69-year-old female with a history of a heart transplant 16 years prior, presented with a large left chest mass identified on fluoroscopy in the cardiac catheterization lab. The patient noted a 40 pound weight loss in one year. A chest X-ray (CXR) and chest computed tomography (CT) demonstrated a large complex cystic mass in the left chest. A CT guided aspiration was performed, and the cytology for the cyst fluid was negative for malignancy. The patient continued to have worsening shortness of breath, a repeat chest CT scan and magnetic resonance imaging (MRI) three months later, demonstrated a recurrence of the left pleural mass. Further, work-up was negative for tumor. A left video assisted thoracotomy exploration was performed and left thoracotomy was needed for the mass resection. The final pathology demonstrated a high grade osteosarcoma. The post-operative course was unremarkable.

5.
J Thorac Dis ; 8(1): E137-9, 2016 Jan.
Article En | MEDLINE | ID: mdl-26904243

Timing of surgical management of acute infective endocarditis is a major challenge, with respect to surgical complications, risks of recurrences and optimal valve repair or replacement. We present a case of a 24-year-old male with a history of intravenous drug abuse, who was referred to our center after 10 days of medical management of acute infective endocarditis. Upon arrival he was in septic shock, multi-organ failure, and mobile vegetations on the tricuspid valve with severe tricuspid regurgitation. He also had bilateral pulmonary infarcts and an ischemic stroke in the right parietal lobe. A successful percutaneous transcatheter mechanical vegetation debulking was performed followed by surgical valve replacement seven days later. This case introduces a new option in the management of right-sided endocarditis in critically ill patient, and demonstrates the technical feasibility of a debulking procedure in this setting, which led subsequently to a significant improvement in patient's condition, and he was ultimately able to undergo definitive surgery.

6.
J Thorac Dis ; 7(11): E552-4, 2015 Nov.
Article En | MEDLINE | ID: mdl-26716054

Extra corporeal membrane oxygenation (ECMO) has remarkably progressed over the recent years. It has become an invaluable tool in the care of adults and pediatric patients with severe cardiogenic shock. At the initiation of ECMO support, the left ventricular contractility is profoundly impaired. Inadequate right ventricular drainage and bronchial circulation can lead to left ventricular distension, with potential deleterious consequences, ranging from inadequate myocardial rest, pulmonary edema, or intracardiac clot formation. Therefore, it is of extreme importance to ensure an adequate left ventricular drainage. Here we present a case of LV thrombus developed while the patient is on central venoarterial (VA) ECMO.

7.
Artif Organs ; 39(12): 1051-5, 2015 Dec.
Article En | MEDLINE | ID: mdl-25864448

B-type natriuretic peptide (BNP) levels have been shown to predict ventricular arrhythmia (VA) and sudden death in patients with heart failure. We sought to determine whether BNP levels before left ventricular assist device (LVAD) implantation can predict VA post LVAD implantation in advanced heart failure patients. We conducted a retrospective study consisting of patients who underwent LVAD implantation in our institution during the period of May 2009-March 2013. The study was limited to patients receiving a HeartMate II or HeartWare LVAD. Acute myocardial infarction patients were excluded. We compared between the patients who developed VA within 15 days post LVAD implantation to the patients without VA. A total of 85 patients underwent LVAD implantation during the study period. Eleven patients were excluded (five acute MI, four without BNP measurements, and two discharged earlier than 13 days post LVAD implantation). The incidence of VA was 31%, with 91% ventricular tachycardia (VT) and 9% ventricular fibrillation. BNP remained the single most powerful predictor of VA even after adjustment for other borderline significant factors in a multivariate logistic regression model (P < 0.05). BNP levels are a strong predictor of VA post LVAD implantation, surpassing previously described risk factors such as age and VT in the past.


Heart Failure/therapy , Heart-Assist Devices/adverse effects , Natriuretic Peptide, Brain/blood , Tachycardia, Ventricular/etiology , Ventricular Fibrillation/etiology , Ventricular Function, Left , Biomarkers/blood , Female , Heart Failure/blood , Heart Failure/diagnosis , Heart Failure/physiopathology , Humans , Indiana , Logistic Models , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Factors , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/physiopathology
8.
Transplantation ; 99(10): 2190-5, 2015 Oct.
Article En | MEDLINE | ID: mdl-25769073

BACKGROUND: Acute cellular rejection (ACR) is a major early complication after lung transplantation (LT) and is a risk factor for chronic rejection. Induction immunosuppression has been used as a strategy to reduce early ACR. Recently, our LT program changed our primary induction protocol from basiliximab with standard maintenance immunosuppression to alemtuzumab induction with reduced dose maintenance immunosuppression. The objective of this study was to compare incidence of ACR after this change in the first 6 months after transplantation. METHODS: A retrospective, cohort review of patients 18 years or older, which received their first LT between January 2010 and September 2012. RESULTS: The primary outcome was comparison of average lung biopsy scores at 6 months. Secondary outcomes included development of grade A2 or higher rejection, infectious outcomes, overall graft and patient survival. At 6 months, the average biopsy score was significantly lower in the alemtuzumab group than the basiliximab group (0.12 ± 0.29 vs 0.74 ± 0.67; P < 0.0001) (Table 2). Grade 2 or higher rejection was significantly higher in the basiliximab group (P < 0.0001). CONCLUSIONS: Alemtuzumab provided superior outcomes in regard to average biopsy score and lower incidence of grade 2 or higher rejection at 6 months. There were no differences in infectious complications or overall graft or patient survival between the 2 groups.


Antibodies, Monoclonal, Humanized/administration & dosage , Antibodies, Monoclonal/administration & dosage , Immunosuppressive Agents/administration & dosage , Lung Transplantation , Recombinant Fusion Proteins/administration & dosage , Adult , Aged , Alemtuzumab , Basiliximab , Biopsy , Female , Graft Rejection/epidemiology , Humans , Immunosuppression Therapy , Male , Middle Aged , Retrospective Studies , Risk Factors , Transplant Recipients , Treatment Outcome
9.
ASAIO J ; 61(2): 156-60, 2015.
Article En | MEDLINE | ID: mdl-25485560

B-type natriuretic peptide (BNP)-guided therapy during the early postoperative period following left ventricular assist device (LVAD) implantation has not been well described in the literature. We conducted a retrospective cohort study consisting of consecutive patients who underwent LVAD implantation at our institution during May 2009 to March 2013. The study was limited to patients receiving HeartMate II (Thoratec) or HVAD (HeartWare) LVADs. Patients with acute myocardial infarction were excluded. We compared between patients with multiple postoperative BNP tests (BNP-guided therapy) and earlier period patients who typically had only a baseline BNP measurement (non-BNP-guided therapy). A total of 85 patients underwent LVAD implantation during the study period. Eight patients were excluded (five acute myocardial infarction, three without BNP measurements). The only differences in the baseline characteristics of BNP versus non-BNP-guided therapy included age and female gender. The postoperative length of hospital stay (LOS) in the BNP-guided therapy group was 5 days shorter when compared with the non-BNP-guided therapy group. In multivariate analysis, BNP-guided therapy remained a significant predictor of reduced LOS. The use of repeated BNP measurements during the early postoperative period was associated with a significantly lower LOS post LVAD implantation.


Heart Failure/blood , Heart Failure/surgery , Heart-Assist Devices , Natriuretic Peptide, Brain/blood , Biomarkers/blood , Cohort Studies , Female , Humans , Length of Stay , Male , Middle Aged , Multivariate Analysis , Retrospective Studies
10.
Clin Transplant ; 28(11): 1279-86, 2014 Nov.
Article En | MEDLINE | ID: mdl-25203694

Although recipient body mass index (BMI) and age are known risk factors for mortality after heart transplantation, how they interact to influence survival is unknown. Our study utilized the UNOS registry from 1997 to 2012 to define the interaction between BMI and age and its impact on survival after heart transplantation. Recipients were stratified by BMI: underweight (<18.5), normal weight (18.5-24.99), overweight (25-29.99), and either moderate (30-34.99), severe (35-39.99), or very severe (≥40) obesity. Recipients were secondarily stratified based on age: 18-40 (younger recipients), 40-65 (reference group), and ≥65 (advanced age recipients). Among younger recipients, being underweight was associated with improved adjusted survival (HR 0.902; p = 0.010) while higher mortality was seen in younger overweight recipients (HR 1.260; p = 0.005). However, no differences in adjusted survival were appreciated in underweight and overweight advanced age recipients. Obesity (BMI ≥ 30) was associated with increased adjusted mortality in normal age recipients (HR 1.152; p = 0.021) and even more so with young (HR 1.576; p < 0.001) and advanced age recipients (HR 1.292; p = 0.001). These results demonstrate that BMI and age interact to impact survival as age modifies BMI-mortality curves, particularly with younger and advanced age recipients.


Age Factors , Body Mass Index , Heart Failure/mortality , Heart Failure/surgery , Heart Transplantation/mortality , Adult , Aged , Databases, Factual , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Proportional Hazards Models , Retrospective Studies , Risk Factors , Survival Rate
11.
J Card Surg ; 29(5): 723-8, 2014 Sep.
Article En | MEDLINE | ID: mdl-25041692

BACKGROUND: Data are limited regarding the influence of donor age on outcomes after heart transplantation. We sought to determine if advanced donor age is associated with differences in survival after heart transplantation and how this compares to waitlist survival. METHODS: All adult heart transplants from 2000 to 2012 were identified using the United Network for Organ Sharing database. Donors were stratified into four age groups: 18-39 (reference group), 40-49, 50-54, and 55 and above. Propensity scoring was used to compare status IA waitlist patients who did not undergo transplantation with IA recipients who received hearts from advanced age donors. The primary outcome of interest was recipient survival and this was analyzed with multivariate Cox regression analysis and the Kaplan-Meier method. RESULTS: A total of 22,960 adult heart transplant recipients were identified. Recipients of hearts from all three older donor groups had significantly increased risk of mortality (HR, 1.187-1.426, all p < 0.001) compared to recipients from donors age 18 to 39. Additionally, propensity-matched status IA patients managed medically without transplantation had significantly worse adjusted survival than status IA recipients who received hearts from older donors age ≥55 (HR, 1.362, p < 0.001). CONCLUSIONS: Compared to donors aged 18-39, age 40 and above is associated with worse adjusted recipient survival in heart transplantation. This survival difference becomes more pronounced as age increases to above 55. However, the survival rate among status IA patients who receive hearts from advanced age donors (≥55) is significantly better compared to similar status IA patients who are managed without transplantation.


Heart Transplantation/mortality , Registries , Tissue Donors/statistics & numerical data , Tissue and Organ Procurement/organization & administration , Tissue and Organ Procurement/statistics & numerical data , Adolescent , Adult , Age Factors , Aged , Databases, Factual , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Propensity Score , Proportional Hazards Models , Risk , Survival Rate , Young Adult
12.
Europace ; 15(1): 11-7, 2013 Jan.
Article En | MEDLINE | ID: mdl-23233490

Ventricular arrhythmia (VA) is a significant factor in the clinical management of patients with congestive heart failure (CHF). Understanding the implications of VA in ventricular assist device-supported CHF patients is critical to appropriate clinical decision making in this special population. This article details research findings on this topic, and attempts to link them to practical patient management strategies.


Heart-Assist Devices/adverse effects , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/prevention & control , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/prevention & control , Ventricular Fibrillation/etiology , Ventricular Fibrillation/prevention & control , Humans
13.
J Surg Res ; 168(1): e149-53, 2011 Jun 01.
Article En | MEDLINE | ID: mdl-21109265

OBJECTIVE: Our purpose was to evaluate our results with CPAs in patients with infected grafts or primary arterial infection with emphasis on long-term durability of these grafts. METHODS: To evaluate the long-term durability of CPAs, clinical outcomes were analyzed following their use for either graft or primary arterial infections at a single institution over a 9-y period (2000-2009). The 30-d mortality rate, 90-d mortality rate, and the cause of early mortality were determined in each case. Among those surviving 90 d, the grafts were evaluated for subsequent failure. RESULTS: From 2000 through 2009, 51 patients with either infected prosthetic grafts (35) or primary arterial infections (15) received CPAs. One patient had infection of a previously placed thoracic allograft. Forty-three graft infections involved either the thoracic or abdominal aorta. Eleven patients presented with fulminant sepsis with systemic inflammatory response syndrome (SIRS), seven of whom died postoperatively. Eight patients presented with aorto-enteric, esophageal, or bronchial fistulae with infected prosthetic grafts. The 30-d mortality rate was 25.5% (11 deaths) seven of which occurred in patients with SIRS. The 90-d mortality rate was 41.4%. There were 10 graft failures, seven occurring in patients with aorto-enteric or bronchial fistulae all of whom had recurrent hemorrhage. The other three graft failures were due to anastomotic hemorrhage in the early postoperative period. Among those surviving 90 d, the mean follow-up was 46.4 mo (range 1-112 mo). No aneurysmal degeneration of the CPAs was noted. Only one subsequent allograft graft failure was noted among those surviving more than 90 d. CONCLUSIONS: CPAs are a suitable option in dealing with cardiovascular infections. Patients with enteric or bronchial fistulae are a difficult group to treat perhaps because of ongoing contamination of the allograft. The operative mortalities are largely determined by patient comorbidities (SIRS). Subsequent degeneration or infection of the CPAs is rare.


Cryopreservation , Graft Rejection/microbiology , Graft Rejection/surgery , Vascular Diseases/microbiology , Vascular Diseases/surgery , Vascular Grafting/methods , Adult , Aged , Aged, 80 and over , Aorta, Abdominal/transplantation , Aorta, Thoracic/transplantation , Carotid Arteries/transplantation , Female , Femoral Artery/transplantation , Fistula/microbiology , Fistula/mortality , Fistula/surgery , Graft Rejection/mortality , Humans , Male , Middle Aged , Postoperative Complications , Retrospective Studies , Sepsis/microbiology , Sepsis/mortality , Sepsis/surgery , Survival Rate , Time Factors , Treatment Outcome , Vascular Diseases/mortality , Vascular Grafting/adverse effects
14.
J Am Coll Cardiol ; 56(18): 1435-46, 2010 Oct 26.
Article En | MEDLINE | ID: mdl-20951319

Acute right ventricular (RV) failure is a frequent and serious clinical challenge in the intensive care unit. It is usually seen as a consequence of left ventricular failure, pulmonary embolism, pulmonary hypertension, sepsis, acute lung injury or after cardiothoracic surgery. The presence of acute RV failure not only carries substantial morbidity and mortality, but also complicates the use of commonly used treatment strategies in critically ill patients. In contrast to the left ventricle, the RV remains relatively understudied, and investigations of the treatment of isolated RV failure are rare and usually limited to nonrandomized observations. We searched PubMed for papers in the English language by using the search words right ventricle, right ventricular failure, pulmonary hypertension, sepsis, shock, acute lung injury, cardiothoracic surgery, mechanical ventilation, vasopressors, inotropes, and pulmonary vasodilators. These were used in various combinations. We read the abstracts of the relevant titles to confirm their relevance, and the full papers were then extracted. References from extracted papers were checked for any additional relevant papers. This review summarizes the general measures, ventilation strategies, vasoactive substances, and surgical as well as mechanical approaches that are currently used or actively investigated in the treatment of the acutely failing RV.


Heart Failure/diagnosis , Heart Failure/therapy , Ventricular Dysfunction, Right/diagnosis , Ventricular Dysfunction, Right/therapy , Acute Disease , Animals , Coronary Artery Bypass/methods , Coronary Artery Bypass/trends , Heart Failure/etiology , Humans , Treatment Outcome , Vasodilator Agents/therapeutic use , Ventricular Dysfunction, Right/complications
15.
N Engl J Med ; 361(23): 2241-51, 2009 Dec 03.
Article En | MEDLINE | ID: mdl-19920051

BACKGROUND: Patients with advanced heart failure have improved survival rates and quality of life when treated with implanted pulsatile-flow left ventricular assist devices as compared with medical therapy. New continuous-flow devices are smaller and may be more durable than the pulsatile-flow devices. METHODS: In this randomized trial, we enrolled patients with advanced heart failure who were ineligible for transplantation, in a 2:1 ratio, to undergo implantation of a continuous-flow device (134 patients) or the currently approved pulsatile-flow device (66 patients). The primary composite end point was, at 2 years, survival free from disabling stroke and reoperation to repair or replace the device. Secondary end points included survival, frequency of adverse events, the quality of life, and functional capacity. RESULTS: Preoperative characteristics were similar in the two treatment groups, with a median age of 64 years (range, 26 to 81), a mean left ventricular ejection fraction of 17%, and nearly 80% of patients receiving intravenous inotropic agents. The primary composite end point was achieved in more patients with continuous-flow devices than with pulsatile-flow devices (62 of 134 [46%] vs. 7 of 66 [11%]; P<0.001; hazard ratio, 0.38; 95% confidence interval, 0.27 to 0.54; P<0.001), and patients with continuous-flow devices had superior actuarial survival rates at 2 years (58% vs. 24%, P=0.008). Adverse events and device replacements were less frequent in patients with the continuous-flow device. The quality of life and functional capacity improved significantly in both groups. CONCLUSIONS: Treatment with a continuous-flow left ventricular assist device in patients with advanced heart failure significantly improved the probability of survival free from stroke and device failure at 2 years as compared with a pulsatile device. Both devices significantly improved the quality of life and functional capacity. (ClinicalTrials.gov number, NCT00121485.)


Heart Failure/therapy , Heart-Assist Devices , Actuarial Analysis , Adult , Aged , Aged, 80 and over , Cause of Death , Female , Heart Failure/mortality , Heart-Assist Devices/adverse effects , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Proportional Hazards Models , Prosthesis Design , Prosthesis Failure , Quality of Life , Stroke/etiology , Stroke/mortality , Stroke Volume
16.
J Cyst Fibros ; 7(4): 280-284, 2008 Jul.
Article En | MEDLINE | ID: mdl-18036998

UNLABELLED: Cystic fibrosis (CF) is an inherited disorder that presents in childhood as a multisystem disease. Pulmonary failure and pancreatic insufficiency, including CF related diabetes (CFRD) and exocrine insufficiency, are common complications of this disease. In this report we review the first three simultaneous lung and pancreas transplantations in CF patients with diabetes. METHODS: All three CF patients presented for evaluation for lung transplantation and had pancreatic insufficiency requiring enzyme supplementation and CFRD requiring insulin. All were severely malnourished and required nutritional supplementation. SURGICAL TECHNIQUE: In each case, the allografts were procured from a single cadaveric donor. Bilateral lung transplantation was performed first using two separate thoracic incisions. The pancreas transplant was performed with systemic venous drainage and enteric exocrine drainage. RESULTS: The pancreas allografts all functioned normally with normoglycemia independent of insulin. As a result of the enteric drainage of the pancreas allograft, supplemental pancreatic enzymes were no longer required. Despite several complications detailed in the manuscript, all three remain independent of supplemental oxygen, insulin and pancreatic enzyme replacement at 4, 6 and 14 months of follow-up. CONCLUSION: Simultaneous lung and pancreas transplantation in patients with CF can be performed successfully and provides the advantages of normoglycemia and improves nutrition for patients requiring lung transplantation.


Cystic Fibrosis/surgery , Diabetes Mellitus/surgery , Lung Transplantation , Pancreas Transplantation , Adult , Cystic Fibrosis/complications , Diabetes Mellitus/etiology , Female , Humans , Male
17.
J Thorac Cardiovasc Surg ; 133(2): 333-8, 2007 Feb.
Article En | MEDLINE | ID: mdl-17258558

OBJECTIVE: Leak after esophageal anastomosis or perforation repair prolongs hospitalization, prevents oral hydration and nutrition, and can produce localized infection or sepsis. This investigation reviews our experience treating postoperative esophageal leaks with the Polyflex esophageal stent (Boston Scientific, Natick, Mass). METHODS: Over a 30-month period, patients with a postoperative esophageal leak were treated with the Polyflex stent for leak occlusion. Leak occlusion was confirmed by means of esophagraphy. Patients were followed until their stent was removed and their esophageal leak had resolved. RESULTS: Twenty-one patients had 27 stents placed for leak occlusion after esophagectomy (n = 5), esophageal perforation (n = 5), surgical (n = 4) or endoscopic (n = 2) antireflux procedure, and esophageal diverticulectomy (n = 3) or myotomy (n = 2). The mean interval between surgical intervention and stent placement was 12 +/- 8 days (range, 3-31 days). Occlusion of the leak occurred in 20 patients. One patient experienced a dehiscence of the surgical esophageal perforation repair requiring esophageal diversion. Stent migration requiring repositioning (n = 3) or replacement (n = 4) occurred in 5 (24%) patients. Twenty (95%) stents were removed without residual leak (mean, 51 +/- 43 days; range, 15-175 days). One patient had a stricture after stent removal that required endoscopic dilatation. One patient in this series died. CONCLUSIONS: The Polyflex esophageal stent is an effective method for occluding a postoperative esophageal leak. It rapidly eliminates contamination of the mediastinum, pleura, and peritoneum; allows oral hydration and nutrition; and is easily removable. These stents also offer an appealing alternative to traditional esophageal diversion and subsequent reconstruction in patients with a persistent esophageal leak.


Esophageal Fistula/surgery , Esophageal Perforation/surgery , Esophagectomy/adverse effects , Stents , Adult , Aged , Aged, 80 and over , Anastomosis, Surgical/adverse effects , Anastomosis, Surgical/methods , Coated Materials, Biocompatible , Cohort Studies , Endoscopy/methods , Esophageal Diseases/diagnosis , Esophageal Diseases/surgery , Esophageal Fistula/etiology , Esophageal Perforation/etiology , Esophagectomy/methods , Esophagoscopy/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/physiopathology , Postoperative Complications/surgery , Risk Assessment , Silicones/pharmacology , Treatment Outcome
18.
Ann Thorac Surg ; 81(5): 1853-7; discussion 1857, 2006 May.
Article En | MEDLINE | ID: mdl-16631685

BACKGROUND: Plication of the hemidiaphragm for unilateral diaphragm paralysis is infrequently performed in adults. Barriers to diaphragm plication have included the perceived need for thoracotomy and uncertainty of the potential benefits. The purpose of this investigation was to assess the effects of video-assisted thoracoscopic diaphragm plication in symptomatic adult patients with unilateral diaphragm paralysis. METHODS: Patients with unilateral diaphragm paralysis underwent an evaluation that included a chest radiograph, fluoroscopic sniff test, pulmonary spirometry, and the Medical Research Council (MRC) dyspnea score. Patients with symptomatic unilateral diaphragm paralysis present for at least 6 months were offered video-assisted thoracoscopic diaphragm plication. Patients who underwent diaphragm plication as well as those who declined surgery were reassessed at 6 months with a chest radiograph, spirometry, and the MRC dyspnea score. RESULTS: Twenty-five patients underwent left (19) or right (6) diaphragm plication through video-assisted thoracoscopic diaphragm plication (22) or thoracotomy (3). There were no operative deaths. Mean hospital length of stay for diaphragm plication was 3.7 days for video-assisted thoracoscopic diaphragm plication and 5.4 days for thoracotomy. After diaphragm plication, mean forced vital capacity, forced expiratory volume at 1 second, functional residual capacity, and total lung capacity improved by 17%, 21.4%, 20.3%, and 16.1%, respectively (p < 005) at 6 months. Mean MRC dyspnea scores also significantly improved in the operative cohort (p < 0001). Seventeen patients in the surgical cohort had returned to work at 6 months. Seven patients treated without surgery displayed a trend toward more frequent hospitalizations and deteriorating pulmonary spirometry and MRC dyspnea scores during the follow-up period. CONCLUSIONS: Plication of the hemidiaphragm using minimally invasive techniques produced significant improvements in patients' functional status, pulmonary spirometry, and MRC dyspnea scores. Video-assisted thoracoscopic diaphragm plication should be considered appropriate therapy in symptomatic adult patients with unilateral diaphragm paralysis.


Diaphragm/surgery , Dyspnea/surgery , Respiratory Paralysis/surgery , Thoracic Surgery, Video-Assisted , Adult , Dyspnea/etiology , Female , Humans , Length of Stay , Male , Middle Aged , Recovery of Function , Respiratory Function Tests , Respiratory Paralysis/complications , Treatment Outcome
...