Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 281
1.
J Microsc ; 294(3): 397-410, 2024 Jun.
Article En | MEDLINE | ID: mdl-38691400

In the dynamic landscape of scientific research, imaging core facilities are vital hubs propelling collaboration and innovation at the technology development and dissemination frontier. Here, we present a collaborative effort led by Global BioImaging (GBI), introducing international recommendations geared towards elevating the careers of Imaging Scientists in core facilities. Despite the critical role of Imaging Scientists in modern research ecosystems, challenges persist in recognising their value, aligning performance metrics and providing avenues for career progression and job security. The challenges encompass a mismatch between classic academic career paths and service-oriented roles, resulting in a lack of understanding regarding the value and impact of Imaging Scientists and core facilities and how to evaluate them properly. They further include challenges around sustainability, dedicated training opportunities and the recruitment and retention of talent. Structured across these interrelated sections, the recommendations within this publication aim to propose globally applicable solutions to navigate these challenges. These recommendations apply equally to colleagues working in other core facilities and research institutions through which access to technologies is facilitated and supported. This publication emphasises the pivotal role of Imaging Scientists in advancing research programs and presents a blueprint for fostering their career progression within institutions all around the world.


Research Personnel , Humans , Career Mobility , Biomedical Research/methods , Career Choice
2.
J Cardiovasc Magn Reson ; : 101045, 2024 May 23.
Article En | MEDLINE | ID: mdl-38795790

BACKGROUND: Novel treatment strategies are needed to improve the structure and function in the myocardium post infarction. In vitro-matured pluripotent stem cell-derived cardiomyocytes (PSC-CMs), have been shown to be a promising regenerative strategy. We hypothesized that mature PSC-CMs will have anisotropic structure and improved cell alignment when compared to immature PSC-CMs using magnetic resonance imaging (MRI) in a guinea pig model of cardiac injury. METHODS: Guinea pigs (n=16) were cryoinjured on day -10, followed by transplantation of either 108 polydimethylsiloxane-matured PSC-CMs (PDMS, n=6) or 108 immature tissue culture plastic-generated PSC-CMs (TCP, n=6) on day 0. Vehicle (sham-treated) subjects were injected with a pro-survival cocktail devoid of cells (n=4), while healthy controls (n=4) did not undergo cryoinjury or treatment. Animals were sacrificed on either day +14 or day +28 post transplantation. Animals were imaged ex vivo on a 7T Bruker MRI. A 3D Diffusion Tensor Imaging sequence was used to quantify structure via fractional anisotropy (FA), mean diffusivity (MD) and myocyte alignment measured by the standard deviation of the transverse angle (TA). RESULTS: MD and FA of mature PDMS grafts demonstrated anisotropy that were not significantly different than the healthy control hearts (MD=1.1 ± 0.12 ×10-3 mm2/s vs. 0.93 ± 0.01 ×10-3 mm2/s, p=0.4 and FA=0.22±0.05 vs. 0.26±0.001, p=0.5). Immature TCP grafts exhibited significantly higher MD than the healthy control (1.3 ± 0.08 ×10-3 mm2/s, p<0.05) and significantly lower FA than the control (0.12±0.02, p< 0.05) but were not different from mature PDMS grafts in this small cohort. TA of healthy controls showed low variability and were not significantly different than mature PDMS grafts (p=0.4) while immature TCP grafts were significantly different (p<0.001). DISCUSSION: DTI parameters of mature graft tissue trended towards that of the healthy myocardium, indicating the grafted cardiomyocytes may have a similar phenotype to healthy tissue. Contrast-enhanced MR images corresponded well to histological staining, demonstrating a non-invasive method of localizing the repopulated cardiomyocytes within the scar. CONCLUSIONS: The DTI measures within graft tissue were indicative of anisotropic structure, and showed greater myocyte organization compared to the scarred territory. These findings show that MRI is a valuable tool to assess structural impacts of regenerative therapies.

3.
Comput Med Imaging Graph ; 115: 102372, 2024 Mar 26.
Article En | MEDLINE | ID: mdl-38581959

PURPOSE: To investigate the feasibility of a deep learning algorithm combining variational autoencoder (VAE) and two-dimensional (2D) convolutional neural networks (CNN) for automatically quantifying hard tissue presence and morphology in multi-contrast magnetic resonance (MR) images of peripheral arterial disease (PAD) occlusive lesions. METHODS: Multi-contrast MR images (T2-weighted and ultrashort echo time) were acquired from lesions harvested from six amputated legs with high isotropic spatial resolution (0.078 mm and 0.156 mm, respectively) at 9.4 T. A total of 4014 pseudo-color combined images were generated, with 75% used to train a VAE employing custom 2D CNN layers. A Gaussian mixture model (GMM) was employed to classify the latent space data into four tissue classes: I) concentric calcified (c), II) eccentric calcified (e), III) occluded with hard tissue (h) and IV) occluded with soft tissue (s). Test image probabilities, encoded by the trained VAE were used to evaluate model performance. RESULTS: GMM component classification probabilities ranged from 0.92 to 0.97 for class (c), 1.00 for class (e), 0.82-0.95 for class (h) and 0.56-0.93 for the remaining class (s). Due to the complexity of soft-tissue lesions reflected in the heterogeneity of the pseudo-color images, more GMM components (n=17) were attributed to class (s), compared to the other three (c, e and h) (n=6). CONCLUSION: Combination of 2D CNN VAE and GMM achieves high classification probabilities for hard tissue-containing lesions. Automatic recognition of these classes may aid therapeutic decision-making and identifying uncrossable lesions prior to endovascular intervention.

4.
IEEE Trans Biomed Eng ; PP2024 Apr 22.
Article En | MEDLINE | ID: mdl-38648149

OBJECTIVE: Investigate the capacity of MRI to evaluate efficacy of radiofrequency (RF) ablations delivered to MRI-defined arrhythmogenic substrates. METHODS: Baseline MRI was performed at 3T including 3D LGE in a swine model of chronic myocardial infarct (N=8). MRI-derived maps of scar and heterogeneous tissue channels (HTCs) were generated using ADAS 3D. Animals underwent electroanatomic mapping and ablation of the left ventricle in CARTO3, guided by MRI-derived scar maps. Post-ablation MRI (in vivo at 3T in 5/8 animals; ex vivo at 1.5T in 3/8) included 3D native T1-weighted IR-SPGR (TI=700-800ms) to visualize RF lesions. T1-derived RF lesions were compared against excised tissue. The locations of T1-derived RF lesions were compared against CARTO ablation tags, and segment-wise sensitivity and specificity of lesion detection were calculated within the AHA 17-segment model. RESULTS: RF lesions were clearly visualized in HTCs, scar, and myocardium. Ablation patterns delivered in CARTO matched T1-derived RF lesion patterns with high sensitivity (88.9%) and specificity (94.7%), and were closely matched in registered MR-EP data sets, with a displacement of 5.4 ±3.8mm (N=152 ablation tags). CONCLUSION: Integrating MRI into ablative procedures for RF lesion assessment is feasible. Patterns of RF lesions created using a standard 3D EAM system are accurately reflected by MRI visualization in healthy myocardium, scar, and HTCs comprising the MRI-defined arrhythmia substrate. SIGNIFICANCE: MRI visualization of RF lesions can provide near-immediate (<24h) assessment of ablation, potentially indicating whether critical MRI-defined ventricular tachycardia substrates have been adequately ablated.

5.
Magn Reson Imaging ; 108: 40-46, 2024 May.
Article En | MEDLINE | ID: mdl-38309379

INTRODUCTION: Cardiac magnetic resonance imaging (MRI), including late gadolinium enhancement (LGE), plays an important role in the diagnosis and prognostication of ischemic and non-ischemic myocardial injury. Conventional LGE sequences require patients to perform multiple breath-holds and require long acquisition times. In this study, we compare image quality and assessment of myocardial LGE using an accelerated free-breathing sequence to the conventional standard-of-care sequence. METHODS: In this prospective cohort study, a total of 41 patients post Coronavirus 2019 (COVID-19) infection were included. Studies were performed on a 1.5 Tesla scanner with LGE imaging acquired using a conventional inversion recovery rapid gradient echo (conventional LGE) sequence followed by the novel accelerated free-breathing (FB-LGE) sequence. Image quality was visually scored (ordinal scale from 1 to 5) and compared between conventional and free-breathing sequences using the Wilcoxon rank sum test. Presence of per-segment LGE was identified according to the American Heart Association 16-segment myocardial model and compared across both conventional LGE and FB-LGE sequences using a two-sided chi-square test. The perpatient LGE extent was also evaluated using both sequences and compared using the Wilcoxon rank sum test. Interobserver variability in detection of per-segment LGE and per-patient LGE extent was evaluated using Cohen's kappa statistic and interclass correlation (ICC), respectively. RESULTS: The mean acquisition time for the FB-LGE sequence was 17 s compared to 413 s for the conventional LGE sequence (P < 0.001). Assessment of image quality was similar between both sequences (P = 0.19). There were no statistically significant differences in LGE assessed using the FB-LGE versus conventional LGE on a per-segment (P = 0.42) and per-patient (P = 0.06) basis. Interobserver variability in LGE assessment for FB-LGE was good for per-segment (= 0.71) and per-patient extent (ICC = 0.92) analyses. CONCLUSIONS: The accelerated FB-LGE sequence performed comparably to the conventional standard-of-care LGE sequence in a cohort of patients post COVID-19 infection in a fraction of the time and without the need for breath-holding. Such a sequence could impact clinical practice by increasing cardiac MRI throughput and accessibility for frail or acutely ill patients unable to perform breath-holding.


COVID-19 , Contrast Media , Humans , Gadolinium , Prospective Studies , Respiration , Magnetic Resonance Imaging/methods , Myocardium/pathology , COVID-19/diagnostic imaging
6.
IEEE Trans Med Imaging ; 43(1): 449-458, 2024 Jan.
Article En | MEDLINE | ID: mdl-37643100

Catheter based procedures are typically guided by X-Ray, which suffers from low soft tissue contrast and only provides 2D projection images of a 3D volume. Intravascular ultrasound (IVUS) can serve as a complementary imaging technique. Forward viewing catheters are useful for visualizing obstructions along the path of the catheter. The CathEye system mechanically steers a single-element transducer to generate a forward-looking surface reconstruction from an irregularly spaced 2-D scan pattern. The steerable catheter leverages an expandable frame with cables to manipulate the distal end independently of vessel tortuosity. The tip position is estimated by measuring the cable displacements and used to create surface reconstructions of the imaging workspace with the single-element transducer. CathEye's imaging capabilities were tested with an agar phantom and an ex vivo chronic total occlusion (CTO) sample while the catheter was confined to various tortuous paths. The CathEye maintained similar scan patterns regardless of path tortuosity and was able to recreate major features of the imaging targets, such as holes and extrusions. The feasibility of forward-looking IVUS with the CathEye is demonstrated in this study. The CathEye mechanism can be applied to other imaging modalities with field-of-view (FOV) limitations and represents the basis for an interventional device fully integrated with image guidance.


Catheters , Ultrasonography, Interventional , Ultrasonography/methods , Ultrasonography, Interventional/methods , Equipment Design , Phantoms, Imaging
7.
Front Cardiovasc Med ; 10: 1160183, 2023.
Article En | MEDLINE | ID: mdl-37790594

T1 mapping is becoming a staple magnetic resonance imaging method for diagnosing myocardial diseases such as ischemic cardiomyopathy, hypertrophic cardiomyopathy, myocarditis, and more. Clinically, most T1 mapping sequences acquire a single slice at a single cardiac phase across a 10 to 15-heartbeat breath-hold, with one to three slices acquired in total. This leaves opportunities for improving patient comfort and information density by acquiring data across multiple cardiac phases in free-running acquisitions and across multiple respiratory phases in free-breathing acquisitions. Scanning in the presence of cardiac and respiratory motion requires more complex motion characterization and compensation. Most clinical mapping sequences use 2D single-slice acquisitions; however newer techniques allow for motion-compensated reconstructions in three dimensions and beyond. To further address confounding factors and improve measurement accuracy, T1 maps can be acquired jointly with other quantitative parameters such as T2, T2∗, fat fraction, and more. These multiparametric acquisitions allow for constrained reconstruction approaches that isolate contributions to T1 from other motion and relaxation mechanisms. In this review, we examine the state of the literature in motion-corrected and motion-resolved T1 mapping, with potential future directions for further technical development and clinical translation.

8.
Ann Biomed Eng ; 51(12): 2812-2823, 2023 Dec.
Article En | MEDLINE | ID: mdl-37561231

Peripheral arterial diseases are commonly managed with endovascular procedures, which often face limitations in device control and visualization under X-ray fluoroscopy guidance. In response, we developed the CathCam, an angioscope integrated into an expandable cable-driven parallel mechanism to enhance real-time visualization, precise device positioning and catheter support for successful plaque crossing. The primary objective of this study was to assess and compare the performance of the novel CathCam with respect to conventional catheters and the CathPilot (i.e., CathCam without the angioscope), for applications in crossing chronic total occlusions (CTO). We first assessed the system in 3D-printed phantom models, followed by an ex vivo evaluation with CTO samples from a patient's superficial femoral artery. We measured and compared success rates, crossing times, and fluoroscopy times in both experiments. The CathCam demonstrated a 100% success rate in phantom experiments and a 75% success rate in ex vivo experiments with CTO samples, compared to conventional catheters, with 35% and 25% success rates, respectively. The average crossing times for the CathCam and the conventional catheter were 31 s and 502 s for the phantom experiments and 210 s and 511 s for the actual CTO lesions. The Cathcam also showed to be a reliable endovascular imaging approach in an in vivo experiment. Compared to conventional catheters, the CathCam significantly increased the success rate and reduced crossing and fluoroscopy times in both phantom and ex vivo setups. CathCam can potentially improve clinical outcomes for minimally invasive endovascular interventions by offering high-resolution real-time imaging alongside accurate device control.


Endovascular Procedures , Peripheral Arterial Disease , Humans , Angioscopes , Catheters , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Treatment Outcome , Chronic Disease
9.
Curr Protoc ; 3(6): e820, 2023 Jun.
Article En | MEDLINE | ID: mdl-37338194

The use of polychromatic immunofluorescent staining on whole-mount skin enables cell type characterization and aids in the delineation of the physiological and immunological strategies used by the skin to combat pathogens. Using whole-mount skin for polychromatic immunofluorescent staining removes the need for histological sectioning and enables the visualization of anatomical structures and immune cell types in three dimensions. Here we present a detailed protocol for immunostaining with fluorescence-conjugated primary antibodies in whole-mount skin to reveal structural landmarks and specific immune cell types using confocal laser scanning microscopy (CLSM) (Basic Protocol 1). The optimized staining panel reveals structural features such as blood vessels (CD31 antibody) and the lymphatic network (LYVE-1 antibody), in combination with MHCII antibodies for antigen-presenting cells (APCs), CD64 for macrophages and monocytes, CD103 for dendritic epidermal T cells (DETC), and CD326 for Langerhans cells (LC). Basic Protocol 2 describes image visualization pipelines using open-source software (ImageJ/FIJI), enabling four visualization options (z-projections, orthogonal views, 3D visualization, and animation). Basic Protocol 3 describes a quantitative analysis pipeline using CellProfiler to characterize the spatial relationship between cell types using mathematical indices such as Spatial Distribution Index (SDI), Neighborhood Frequency (NF), and Normalized Median Evenness (NME). These protocols will enable researchers to stain, record, analyze, and interpret data from whole-mount skin using commercially available reagents in a CLSM-equipped laboratory and freely available analysis software. © 2023 Wiley Periodicals LLC. Basic Protocol 1: Immunofluorescent staining and imaging for whole-mount mouse skin Basic Protocol 2: File rendering and visualization using FIJI Basic Protocol 3: Spatial image analysis using CellProfiler.


Imaging, Three-Dimensional , Skin , Animals , Mice , Imaging, Three-Dimensional/methods , Skin/diagnostic imaging , Staining and Labeling , Coloring Agents , Microscopy, Confocal/methods
10.
IEEE Trans Biomed Eng ; 70(11): 3116-3125, 2023 Nov.
Article En | MEDLINE | ID: mdl-37195835

OBJECTIVES: Peripheral endovascular revascularization procedures often fail due to technical limitations of guidewire support, steering, and visualization. The novel CathPilot catheter aims to address these challenges. This study assesses the safety and feasibility of the CathPilot and compares its performance to conventional catheters for peripheral vascular interventions. METHODS: The study compared the CathPilot to non-steerable and steerable catheters. The success rates and access times for a relevant target inside a tortuous vessel phantom model were assessed. The reachable workspace within the vessel and the guidewire's force delivery capabilities were also evaluated. To validate the technology, chronic total occlusion tissue samples were used ex vivo to compare crossing success rates with conventional catheters. Finally, in vivo experiments in a porcine aorta were conducted to evaluate safety and feasibility. RESULTS: The success rates for reaching the set targets were 31%, 69%, and 100% with the non-steerable catheter, the steerable catheter, and the CathPilot, respectively. CathPilot had a significantly larger reachable workspace, and allowed for up to four times higher force delivery and pushability. In crossing of chronic total occlusion samples, the CathPilot achieved a success rate of 83% and 100%, for fresh and fixed lesions respectively, which was also significantly higher than conventional catheters. The device was fully functional in the in vivo study, and there were no signs of coagulation or damage to the vessel wall. CONCLUSION: This study shows the safety and feasibility of the CathPilot system and its potential to reduce failure and complication rates in peripheral vascular interventions. The novel catheter outperformed conventional catheters in all defined metrics. This technology can potentially improve the success rate and outcome of peripheral endovascular revascularization procedures.

11.
Biology (Basel) ; 12(4)2023 Apr 14.
Article En | MEDLINE | ID: mdl-37106796

Human ageing is accompanied by poor responses to infection and decreased vaccine efficacy. While the causes of this can be attributed to defects in the immune system that increase with age, it is unknown whether mitochondrial dysfunction may also contribute to these phenomena. This study aims to assess mitochondrial dysfunction in CD4+ terminal effector memory T cells re-expressing CD45RA (TEMRA) cells and other CD4+ memory T cell subtypes, which are increased in number in the elderly population, with respect to how their metabolic responses to stimulation are altered compared to CD4+ naïve T cells. In this study, we show that CD4+ TEMRA cells exhibit altered mitochondrial dynamics compared to CD4+ naïve cells and CD4+ central and effector memory cells, with a 25% reduction in OPA1 expression. CD4+ TEMRA and memory cells show increased upregulation of Glucose transporter 1 following stimulation and higher levels of mitochondrial mass compared to CD4+ naïve T cells. Additionally, TEMRA cells exhibit a decrease in mitochondrial membrane potential compared to other CD4+ memory cell subsets by up to 50%. By comparing young to aged individuals, more significant mitochondria mass and lower membrane potential were observed in CD4+ TEMRA of young individuals. In conclusion, we suggest that CD4+ TEMRA cells may be impaired with respect to their metabolic response to stimulation, possibly contributing to impaired responses to infection and vaccination.

12.
IEEE Trans Biomed Eng ; 70(6): 1955-1966, 2023 06.
Article En | MEDLINE | ID: mdl-37015623

OBJECTIVE: Convolutional neural networks (CNNs) have demonstrated promise in automated cardiac magnetic resonance image segmentation. However, when using CNNs in a large real-world dataset, it is important to quantify segmentation uncertainty and identify segmentations which could be problematic. In this work, we performed a systematic study of Bayesian and non-Bayesian methods for estimating uncertainty in segmentation neural networks. METHODS: We evaluated Bayes by Backprop, Monte Carlo Dropout, Deep Ensembles, and Stochastic Segmentation Networks in terms of segmentation accuracy, probability calibration, uncertainty on out-of-distribution images, and segmentation quality control. RESULTS: We observed that Deep Ensembles outperformed the other methods except for images with heavy noise and blurring distortions. We showed that Bayes by Backprop is more robust to noise distortions while Stochastic Segmentation Networks are more resistant to blurring distortions. For segmentation quality control, we showed that segmentation uncertainty is correlated with segmentation accuracy for all the methods. With the incorporation of uncertainty estimates, we were able to reduce the percentage of poor segmentation to 5% by flagging 31-48% of the most uncertain segmentations for manual review, substantially lower than random review without using neural network uncertainty (reviewing 75-78% of all images). CONCLUSION: This work provides a comprehensive evaluation of uncertainty estimation methods and showed that Deep Ensembles outperformed other methods in most cases. SIGNIFICANCE: Neural network uncertainty measures can help identify potentially inaccurate segmentations and alert users for manual review.


Benchmarking , Neural Networks, Computer , Uncertainty , Magnetic Resonance Imaging/methods , Radiography , Image Processing, Computer-Assisted/methods
13.
J Magn Reson Imaging ; 58(6): 1777-1784, 2023 12.
Article En | MEDLINE | ID: mdl-36872614

BACKGROUND: The prevalence of abnormal cardiac magnetic resonance imaging (MRI) findings indicative of myocardial injury in patients who recovered from coronavirus disease 2019 (COVID-19) is currently unclear, with a high variability in the reported prevalence. PURPOSE: To assess the prevalence of myocardial injury after a COVID-19 infection. STUDY TYPE: Prospective, bicentric study. SUBJECTS: Seventy consecutive patients who recovered from COVID-19 and were previously hospitalized. Mean age was 57 years and 39% of the patients were female. Ten healthy controls and a comparator group of 75 nonischemic cardiomyopathy (NICM) patients were employed. FIELD STRENGTH/SEQUENCE: 1.5-T, steady-state free precession (SSFP) gradient-echo sequence, modified Look-Locker inversion recovery sequence with balanced SSFP readout, T2-prepared spiral readout sequence and a T1-weighted inversion recovery fast gradient-echo sequence was acquired ~4-5 months after recovery from COVID-19. ASSESSMENT: The SSFP sequence was utilized for the calculation of left and right ventricular volumes and ejection fractions (LVEF and RVEF) following manual endocardial contouring. T1 and T2 mapping was performed by pixel-wise exponential fitting, and T1 and T2 values were computed by manual contouring of the left ventricular endocardial and epicardial walls. Late gadolinium enhancement (LGE) images were graded qualitatively as LGE present or absent. STATISTICAL TESTS: T-tests and the χ2 or Fisher's exact tests were used to compare continuous and categorical variables respectively between the COVID-19 and NICM groups. Inter-rater agreement was evaluated by the intraclass correlation coefficient for continuous variables and Cohen's kappa test for LGE. RESULTS: Reduced RVEF occurred in 10%, LGE and elevated native T1 in 9%, reduced LVEF in 4%, and elevated T2 in 3% of COVID-19 patients, respectively. Patients with NICM had lower mean LVEF (41.6% ± 6% vs. 60% ± 7%), RVEF (46% ± 5% vs. 61% ± 9%), and a significantly higher prevalence of LGE (27% vs. 9%) when compared to those post-COVID-19. DATA CONCLUSION: Abnormal cardiac MRI findings may show a low prevalence in patients who recovered from COVID-19 and were previously hospitalized. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


COVID-19 , Cardiomyopathies , Heart Injuries , Humans , Female , Middle Aged , Male , Contrast Media , Prospective Studies , Prevalence , Gadolinium , Magnetic Resonance Imaging , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/epidemiology , Stroke Volume , Predictive Value of Tests , Myocardium , Magnetic Resonance Imaging, Cine
14.
Ann Biomed Eng ; 51(7): 1547-1557, 2023 Jul.
Article En | MEDLINE | ID: mdl-36808383

Conventional catheter-based interventions for treating peripheral artery disease suffer high failure and complication rates. The mechanical interactions with the anatomy constrain catheter controllability, while their length and flexibility limit their pushability. Also, the 2D X-ray fluoroscopy guiding these procedures fails to provide sufficient feedback about the device location relative to the anatomy. Our study aims to quantify the performance of conventional non-steerable (NS) and steerable (S) catheters in phantom and ex vivo experiments. In a 10 mm diameter, 30 cm long artery phantom model, with four operators, we evaluated the success rate and crossing time in accessing 1.25 mm target channels, the accessible workspace, and the force delivered through each catheter. For clinical relevance, we evaluated the success rate and crossing time in crossing ex vivo chronic total occlusions. For the S and NS catheters, respectively, users successfully accessed 69 and 31% of the targets, 68 and 45% of the cross-sectional area, and could deliver 14.2 and 10.2 g of mean force. Using a NS catheter, users crossed 0.0 and 9.5% of the fixed and fresh lesions, respectively. Overall, we quantified the limitations of conventional catheters (navigation, reachable workspace, and pushability) for peripheral interventions; this can serve as a basis for comparison with other devices.


Endovascular Procedures , Peripheral Arterial Disease , Humans , Catheters , Peripheral Arterial Disease/therapy , Phantoms, Imaging , Arteries , Equipment Design
15.
Methods Inf Med ; 62(3-04): 90-99, 2023 09.
Article En | MEDLINE | ID: mdl-36787885

BACKGROUND: Health care has evolved to support the involvement of individuals in decision making by, for example, using mobile apps and wearables that may help empower people to actively participate in their treatment and health monitoring. While the term "participatory health informatics" (PHI) has emerged in literature to describe these activities, along with the use of social media for health purposes, the scope of the research field of PHI is not yet well defined. OBJECTIVE: This article proposes a preliminary definition of PHI and defines the scope of the field. METHODS: We used an adapted Delphi study design to gain consensus from participants on a definition developed from a previous review of literature. From the literature we derived a set of attributes describing PHI as comprising 18 characteristics, 14 aims, and 4 relations. We invited researchers, health professionals, and health informaticians to score these characteristics and aims of PHI and their relations to other fields over three survey rounds. In the first round participants were able to offer additional attributes for voting. RESULTS: The first round had 44 participants, with 28 participants participating in all three rounds. These 28 participants were gender-balanced and comprised participants from industry, academia, and health sectors from all continents. Consensus was reached on 16 characteristics, 9 aims, and 6 related fields. DISCUSSION: The consensus reached on attributes of PHI describe PHI as a multidisciplinary field that uses information technology and delivers tools with a focus on individual-centered care. It studies various effects of the use of such tools and technology. Its aims address the individuals in the role of patients, but also the health of a society as a whole. There are relationships to the fields of health informatics, digital health, medical informatics, and consumer health informatics. CONCLUSION: We have proposed a preliminary definition, aims, and relationships of PHI based on literature and expert consensus. These can begin to be used to support development of research priorities and outcomes measurements.


Delivery of Health Care , Medical Informatics , Humans , Delphi Technique , Consensus , Surveys and Questionnaires
16.
Cardiovasc Eng Technol ; 14(3): 419-427, 2023 06.
Article En | MEDLINE | ID: mdl-36828976

PURPOSE: Accurate and reliable catheter navigation is important in formation of adequate lesions during radiofrequency cardiac catheter ablation. To inform future device design efforts and to characterize the limitations of conventional devices, the focus of this study is to assess and quantify the mechanical performance of manual ablation catheters for pulmonary vein isolation procedures within a phantom heart model. METHODS: We measured three important metrics: accuracy of catheter tip navigation to target anatomical landmarks at the pulmonary veins (PVs), orientation of the catheter relative to the tissue at the targets, and the delivered force values and their stability and variations at those targets. A stereovision system was used for navigational guidance and to measure the catheter's tip position and orientation relative to the targets. To measure force, piezoelectric sensors were used which were integrated at the targets, whereby operators were instructed to stabilize the catheter to achieve a chosen reference force value. RESULTS: An overall positioning accuracy of 1.57 ± 1.71 mm was achieved for all targets. No statistical significance was observed in position accuracy between the right and left PVs (p = 0.5138). The orientation of the catheter relative to tissue surface was 41° ± 21° with no statistical significance between targets. The overall force stability was 41 ± 6 g with higher difficulty in force stabilization in the right compared to the left PV (40 ± 8 vs. 43 ± 2 g, p < 0.0001). CONCLUSION: Based on our results, future improvements to manual catheter navigation for ablation should focus on improving device performance in orientation control and improved force stability.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Heart , Catheters , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Treatment Outcome , Equipment Design
17.
Int J Med Inform ; 170: 104908, 2023 02.
Article En | MEDLINE | ID: mdl-36502741

BACKGROUND: The purpose of educational recommendations is to assist in establishing courses and programs in a discipline, to further develop existing educational activities in the various nations, and to support international initiatives for collaboration and sharing of courseware. The International Medical Informatics Association (IMIA) has published two versions of its international recommendations in biomedical and health informatics (BMHI) education, initially in 2000 and revised in 2010. Given the recent changes to the science, technology, the needs of the healthcare systems, and the workforce of BMHI, a revision of the recommendations is necessary. OBJECTIVE: The aim of these updated recommendations is to support educators in developing BMHI curricula at different education levels, to identify essential skills and competencies for certification of healthcare professionals and those working in the field of BMHI, to provide a tool for evaluators of academic BMHI programs to compare and accredit the quality of delivered programs, and to motivate universities, organizations, and health authorities to recognize the need for establishing and further developing BMHI educational programs. METHOD: An IMIA taskforce, established in 2017, updated the recommendations. The taskforce included representatives from all IMIA regions, with several having been involved in the development of the previous version. Workshops were held at different IMIA conferences, and an international Delphi study was performed to collect expert input on new and revised competencies. RESULTS: Recommendations are provided for courses/course tracks in BMHI as part of educational programs in biomedical and health sciences, health information management, and informatics/computer science, as well as for dedicated programs in BMHI (leading to bachelor's, master's, or doctoral degree). The educational needs are described for the roles of BMHI user, BMHI generalist, and BMHI specialist across six domain areas - BMHI core principles; health sciences and services; computer, data and information sciences; social and behavioral sciences; management science; and BMHI specialization. Furthermore, recommendations are provided for dedicated educational programs in BMHI at the level of bachelor's, master's, and doctoral degrees. These are the mainstream academic programs in BMHI. In addition, recommendations for continuing education, certification, and accreditation procedures are provided. CONCLUSION: The IMIA recommendations reflect societal changes related to globalization, digitalization, and digital transformation in general and in healthcare specifically, and center on educational needs for the healthcare workforce, computer scientists, and decision makers to acquire BMHI knowledge and skills at various levels. To support education in BMHI, IMIA offers accreditation of quality BMHI education programs. It supports information exchange on programs and courses in BMHI through its Working Group on Health and Medical Informatics Education.


Education, Medical , Medical Informatics , Humans , Curriculum , Educational Status , Health Education
18.
Radiol Artif Intell ; 4(6): e210294, 2022 Nov.
Article En | MEDLINE | ID: mdl-36523641

Purpose: To design and evaluate an automated deep learning method for segmentation and analysis of cardiac MRI T1 maps with use of synthetic T1-weighted images for MRI relaxation-based contrast augmentation. Materials and Methods: This retrospective study included MRI scans acquired between 2016 and 2019 from 100 patients (mean age ± SD, 55 years ± 13; 72 men) across various clinical abnormalities with use of a modified Look-Locker inversion recovery, or MOLLI, sequence to quantify native T1 (T1native), postcontrast T1 (T1post), and extracellular volume (ECV). Data were divided into training (n = 60) and internal (n = 40) test subsets. "Synthetic" T1-weighted images were generated from the T1 exponential inversion-recovery signal model at a range of optimal inversion times, yielding high blood-myocardium contrast, and were used for contrast-based image augmentation during training and testing of a convolutional neural network for myocardial segmentation. Automated segmentation, T1, and ECV were compared with experts with use of Dice similarity coefficients (DSCs), correlation coefficients, and Bland-Altman analysis. An external test dataset (n = 147) was used to assess model generalization. Results: Internal testing showed high myocardial DSC relative to experts (0.81 ± 0.08), which was similar to interobserver DSC (0.81 ± 0.08). Automated segmental measurements strongly correlated with experts (T1native, R = 0.87; T1post, R = 0.91; ECV, R = 0.92), which were similar to interobserver correlation (T1native, R = 0.86; T1post, R = 0.94; ECV, R = 0.95). External testing showed strong DSC (0.80 ± 0.09) and T1native correlation (R = 0.88) between automatic and expert analysis. Conclusion: This deep learning method leveraging synthetic contrast augmentation may provide accurate automated T1 and ECV analysis for cardiac MRI data acquired across different abnormalities, centers, scanners, and T1 sequences.Keywords: MRI, Cardiac, Tissue Characterization, Segmentation, Convolutional Neural Network, Deep Learning Algorithms, Machine Learning Algorithms, Supervised Learning Supplemental material is available for this article. © RSNA, 2022.

19.
J Cardiovasc Magn Reson ; 24(1): 65, 2022 11 21.
Article En | MEDLINE | ID: mdl-36404335

BACKGROUND: Cardiovascular magnetic resonance (CMR) is an important diagnostic test used in the evaluation of patients with heart failure (HF). However, the demographics and clinical characteristics of those undergoing CMR for evaluation of HF are unknown. Further, the impact of CMR on subsequent HF patient care is unclear. The goal of this study was to describe the characteristics of patients undergoing CMR for HF and to determine the extent to which CMR leads to changes in downstream patient management by comparing pre-CMR indications and post-CMR diagnoses. METHODS: We utilized the Society for Cardiovascular Magnetic Resonance (SCMR) Registry as our data source and abstracted data for patients undergoing CMR scanning for HF indications from 2013 to 2019. Descriptive statistics (percentages, proportions) were performed on key CMR and clinical variables of the patient population. The Fisher's exact test was used when comparing categorical variables. The Wilcoxon rank sum test was used to compare continuous variables. RESULTS: 3,837 patients were included in our study. 94% of the CMRs were performed in the United States with China, South Korea and India also contributing cases. Median age of HF patients was 59.3 years (IQR, 47.1, 68.3 years) with 67% of the scans occurring on women. Almost 2/3 of the patients were scanned on 3T CMR scanners. Overall, 49% of patients who underwent CMR scanning for HF had a change between the pre-test indication and post CMR diagnosis. 53% of patients undergoing scanning on 3T had a change between the pre-test indication and post CMR diagnosis when compared to 44% of patients who were scanned on 1.5T (p < 0.01). CONCLUSION: Our results suggest a potential impact of CMR scanning on downstream diagnosis of patients referred for CMR for HF, with a larger potential impact on those scanned on 3T CMR scanners.


Heart Failure , Humans , Female , Predictive Value of Tests , Magnetic Resonance Spectroscopy , Heart Failure/diagnostic imaging , Heart Failure/therapy , Magnetic Resonance Imaging/methods , Registries
20.
Stud Health Technol Inform ; 300: 64-76, 2022 Oct 26.
Article En | MEDLINE | ID: mdl-36300403

This paper highlights some of the challenges, achievements and collaborations using health informatics education and research as a change agent in which I have been involved over the last 40 years. The Open Software Library (OSL) was a specialist publisher of Computer-Based Training materials (CBT) mainly authored by nurses and medics. The "Rainbow" series of distance learning materials, "Using Information in Managing the Nursing Resource" sold over 55,000 copies. It was utilized as the basis for seven Universities' Certificate and Diploma programmes and in-house training by the NHS to encourage organisational change. Workshops at Manchester University's HSMU focusing on evaluation studies highlighted that most NHS IT projects failed because of human and organisational issues rather than IT. This led to the development of a master's degree in Health Informatics shared between four European Universities. IMIA conferences, Working Groups and the development of the IMIA approved Education Recommendations and the IMIA Knowledge Base are effectively used worldwide.


Education, Distance , Medical Informatics , Humans , Medical Informatics/education , Curriculum , Universities , Organizational Innovation
...