Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 12 de 12
1.
Sensors (Basel) ; 24(8)2024 Apr 09.
Article En | MEDLINE | ID: mdl-38676013

For the application of high-frequency current detection in power systems, such as very fast transient current, lightning current, partial discharge pulse current, etc., current sensors with a quick response are indispensable. Here, we propose a high-frequency magnetoelectric current sensor, which consists of a PZT piezoelectric ceramic and Metglas amorphous alloy. The proposed sensor is designed to work under d15 thickness-shear mode, with the resonant frequency around 1.029 MHz. Furthermore, the proposed sensor is fabricated as a high-frequency magnetoelectric current sensor. A comparative experiment is carried out between the tunnel magnetoresistance sensor and the magnetoelectric sensor, in the aspect of high-frequency current detection up to 3 MHz. Our experimental results demonstrate that the d15 thickness-shear mode magnetoelectric sensor has great potential for high-frequency current detection in smart grids.

2.
Nano Lett ; 24(6): 2003-2010, 2024 Feb 14.
Article En | MEDLINE | ID: mdl-38306120

Heat-assisted magnetic anisotropy engineering has been successfully used in selective magnetic writing and microwave amplification due to a large interfacial thermal resistance between the MgO barrier and the adjacent ferromagnetic layers. However, in spin-orbit torque devices, the writing current does not flow through the tunnel barrier, resulting in a negligible heating effect due to efficient heat dissipation. Here, we report a dramatically reduced switching current density of ∼2.59 MA/cm2 in flexible spin-orbit torque heterostructures, indicating a 98% decrease in writing energy consumption compared with that on a silicon substrate. The reduced driving current density is enabled by the dramatically decreased magnetic anisotropy due to Joule dissipation and the lower thermal conductivity of the flexible substrate. The large magnetic anisotropy could be fully recovered after the impulse, indicating retained high stability. These results pave the way for flexible spintronics with the otherwise incompatible advantages of low power consumption and high stability.

3.
ACS Appl Mater Interfaces ; 16(6): 7463-7469, 2024 Feb 14.
Article En | MEDLINE | ID: mdl-38300878

Control of magnetic anisotropy in thin films with perpendicular magnetic anisotropy is of paramount importance for the development of spintronics with ultralow-energy consumption and high density. Traditional magnetoelectric heterostructures utilized the synergistic effect of piezoelectricity and magnetostriction to realize the electric field control of magnetic anisotropy, resulting in additional fabrication and modulation processes and a complicated device architecture. Here, we have systematically investigated the electric current tuning of the magnetic properties of the metallic NiCo2O4 film with intrinsic perpendicular magnetic anisotropy. Ferrimagnetic-to-paramagnetic phase transition has been induced through Joule heating, resulting in a rapid decrease of both magnetic coercivity and moment. An ultralow current density of 2.5 × 104 A/cm2, which is 2 to 3 orders magnitude lower than that of conventional spin transfer torque devices, has been verified to be effective for the control of the magnetic anisotropy of NiCo2O4. Successful triggering of magnetic switching has been realized through the application of a current pulse. These findings provide new perspectives toward the electric control of magnetic anisotropy and design of spintronics with an ultralow driving current density.

4.
Nanomaterials (Basel) ; 13(24)2023 Dec 17.
Article En | MEDLINE | ID: mdl-38133055

The flexible electronics have application prospects in many fields, including as wearable devices and in structural detection. Spintronics possess the merits of a fast response and high integration density, opening up possibilities for various applications. However, the integration of miniaturization on flexible substrates is impeded inevitably due to the high Joule heat from high current density (1012 A/m2). In this study, a prototype flexible spintronic with device antiferromagnetic/ferromagnetic heterojunctions is proposed. The interlayer coupling strength can be obviously altered by sunlight soaking via direct photo-induced electron doping. With the assistance of a small magnetic field (±125 Oe), the almost 180° flip of magnetization is realized. Furthermore, the magnetoresistance changes (15~29%) of flexible spintronics on fingers receiving light illumination are achieved successfully, exhibiting the wearable application potential. Our findings develop flexible spintronic sensors, expanding the vision for the novel generation of photovoltaic/spintronic devices.

5.
Adv Sci (Weinh) ; 7(17): 2001368, 2020 Sep.
Article En | MEDLINE | ID: mdl-32999819

Low-temperature cofired ceramic technology is the prerequisite for producing advanced integrated piezoelectric devices that enable modern micro-electromechanical systems because of merits such as high level of compactness and ultralow drive voltage. However, piezoceramic structure with shear-type outputs, as a most fundamental functional electronic element, has never been successfully fabricated into multilayer form by the cofired method for decades. Technical manufacture requirements of parallel applied electric fields and polarization are theoretically incompatible with intrinsically orthogonal orientations in naturally occurring shear modes. Herein, inspired by the philosophy of building metamaterial from identical unit cells, an artificial prototype device with distinctive patterned electrodes and arrayed piezoceramic subunits is designed and fabricated, which is proved to perfectly generate synthetic face shear deformation. At the same drive voltage, an enhanced shear-type displacement output by over an order of magnitude is observed beyond previous d15-mode bulk elements. Further results of guided wave-based structural health monitoring and force sensing confirm that the methodology wipes out a tough piezoelectric technique barrier, and promises to fundamentally enlighten advances of integrated shear-mode piezoelectric devices for augmented actuation, sensing, and transduction applications.

6.
ACS Appl Mater Interfaces ; 12(7): 8855-8861, 2020 Feb 19.
Article En | MEDLINE | ID: mdl-31984722

The operation mechanism of giant magnetoresistance (GMR) sensors relies on the linear response of the magnetization direction to an external magnetic field. Since the magnetic anisotropy of ferromagnetic layers can be manipulated by a strain-mediated magnetoelectric coupling effect, we propose a tunable GMR magnetic field sensor design that allows for voltage tuning of the linear range and sensitivity. A spin valve structure Ru/CoFe/Cu/CoFe/IrMn/Ru is grown on a PMN-PT (011) substrate, and the magnetization directions of ferromagnetic layers can be controlled by an electric field. An adjustable linear magnetoresistance is therefore induced. Based on the magnetoelectric coupling effect and spin valve, we prepared tunable GMR magnetic field sensors with bridge structures. The linear sensing range of a DC magnetic field is enhanced 6 times by applying an electric field of 14 kV/cm. The electrically tunable GMR sensor fulfills the requirements to work at different magnetic field ranges in the same configuration, therefore exhibiting great potential for applications in the Internet of things.

7.
Research (Wash D C) ; 2019: 8232097, 2019.
Article En | MEDLINE | ID: mdl-31922139

Fast actuation with nanoprecision over a large range has been a challenge in advanced intelligent manufacturing like lithography mask aligner. Traditional stacked stage method works effectively only in a local, limited range, and vibration coupling is also challenging. Here, we design a dual mechanism multimodal linear actuator (DMMLA) consisted of piezoelectric and electromagnetic costator and coslider for producing macro-, micro-, and nanomotion, respectively. A DMMLA prototype is fabricated, and each working mode is validated separately, confirming its fast motion (0~50 mm/s) in macromotion mode, micromotion (0~135 µm/s) and nanomotion (minimum step: 0~2 nm) in piezoelectric step and servomotion modes. The proposed dual mechanism design and multimodal motion method pave the way for next generation high-precision actuator development.

8.
Sci Rep ; 7(1): 8592, 2017 08 17.
Article En | MEDLINE | ID: mdl-28819271

The magnetic flux gate sensors based on Faraday's Law of Induction are widely used for DC or extremely low frequency magnetic field detection. Recently, as the fast development of multiferroics and magnetoelectric (ME) composite materials, a new technology based on ME coupling effect is emerging for potential devices application. Here, we report a magnetoelectric flux gate sensor (MEFGS) for weak DC magnetic field detection for the first time, which works on a similar magnetic flux gate principle, but based on ME coupling effect. The proposed MEFGS has a shuttle-shaped configuration made of amorphous FeBSi alloy (Metglas) serving as both magnetic and magnetostrictive cores for producing a closed-loop high-frequency magnetic flux and also a longitudinal vibration, and one pair of embedded piezoelectric PMN-PT fibers ([011]-oriented Pb(Mg,Nb)O3-PbTiO3 single crystal) serving as ME flux gate in a differential mode for detecting magnetic anomaly. In this way, the relative change in output signal of the MEFGS under an applied DC magnetic anomaly of 1 nT was greatly enhanced by a factor of 4 to 5 in comparison with the previous reports. The proposed ME flux gate shows a great potential for magnetic anomaly detections, such as magnetic navigation, magnetic based medical diagnosis, etc.

9.
Adv Mater ; 29(19)2017 May.
Article En | MEDLINE | ID: mdl-28256753

Bulk-magnetoelectric (ME) composites consisting of various piezoelectric and piezomagnetic materials with (3-0), (3-1), (2-2), and (2-1) connectivity are proposed in a bid to realize strong ME coupling for next-generation electronic-device applications. Here, 1D (1-1) connectivity ME composites consisting of a [011]-oriented Pb(Mg,Nb)O3 -PbTiO3 (PMN-PT) single-crystal fiber laminated with laser-treated amorphous FeBSi alloy (Metglas) and operating in L-T mode (longitudinally magnetized and transversely poled) are reported, which exhibit an enhanced resonant ME coupling coefficient of ≈7000 V cm-1  Oe-1 , which is nearly seven times higher than the best result published previously, and also a superhigh magnetic sensitivity of 1.35 × 10-13 T (directly detected) at resonance at room temperature, representing a significant advance in bulk magnetoelectric materials. The theoretical analyses based on magnetic-circuit and equivalent-circuit methods show that the enhancement in ME coupling can be attributed to the reduction in resonance loss of laser-treated Metglas alloy due to nanocrystallization and the strong magnetic-flux-concentration effect in (1-1) configuration composites.

10.
Lab Chip ; 13(9): 1743-53, 2013 May 07.
Article En | MEDLINE | ID: mdl-23475014

Various microfluidic cell culture devices have been developed for in vitro cell studies because of their capabilities to reconstitute in vivo microenvironments. However, controlling flows in microfluidic devices is not straightforward due to the wide varieties of fluidic properties of biological samples. Currently, flow observations mainly depend on optical imaging and macro scale transducers, which usually require sophisticated instrumentation and are difficult to scale up. Without real time monitoring, the control of flows can only rely on theoretical calculations and numerical simulations. Consequently, these devices have difficulty in being broadly exploited in biological research. This paper reports a microfluidic device with embedded pressure sensors constructed using electrofluidic circuits, which are electrical circuits built by fluidic channels filled with ionic liquid. A microfluidic device culturing endothelial cells under various shear stress and hydrostatic pressure combinations is developed to demonstrate this concept. The device combines the concepts of electrofluidic circuits for pressure sensing, and an equivalent circuit model to design the cell culture channels. In the experiments, human umbilical vein endothelial cells (HUVECs) are cultured in the device with a continuous medium perfusion, which provides the combinatory mechanical stimulations, while the hydrostatic pressures are monitored in real time to ensure the desired culture conditions. The experimental results demonstrate the importance of real time pressure monitoring, and how both mechanical stimulations affect the HUVEC culture. This developed microfluidic device is simple, robust, and can be easily scaled up for high-throughput experiments. Furthermore, the device provides a practical platform for an in vitro cell culture under well-controlled and dynamic microenvironments.


Human Umbilical Vein Endothelial Cells , Microfluidic Analytical Techniques , Models, Biological , Stress, Physiological , Cells, Cultured , Electrodes , Human Umbilical Vein Endothelial Cells/cytology , Human Umbilical Vein Endothelial Cells/metabolism , Humans , Hydrostatic Pressure , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Pressure , Shear Strength
11.
Biomicrofluidics ; 7(6): 64104, 2013.
Article En | MEDLINE | ID: mdl-24396538

In this paper, we develop a microfluidic device capable of generating nitric oxide (NO) gradients for cell culture using spatially controlled chemical reactions. NO plays an essential role in various biological activities, including nervous, immune, and cardiovascular systems. The device developed in this paper can control NO gradients without utilizing expensive and hazardous high purity NO gas sources or direct addition of NO donors. Consequently, the device provides an efficient, cost-effective, robust, and stable platform to generate NO gradients for cell culture studies. In the experiments, NO gradients are first characterized using a NO-sensitive fluorescence dye, and cell experiments using aortic smooth muscle cells are conducted. The results demonstrate that the device can alter the intracellular NO concentrations and further affect the Ca(2+) concentration oscillation for the cells. The device developed in this paper provides a powerful platform for researchers better study the biological roles of NO and its spatial distribution using in vitro cell models with minimal instrumentation.

12.
Rev Sci Instrum ; 83(4): 045116, 2012 Apr.
Article En | MEDLINE | ID: mdl-22559585

We demonstrate a novel, vertical temperature-mapping incubator utilizing eight layers of thermoelectric (TE) modules mounted around a test tube. The temperature at each layer of the TE module is individually controlled to simulate the vertical temperature profile of geo-temperature variations with depth. Owing to the constraint of non-intrusion to the filled geo-samples, the temperature on the tube wall is adopted for measurement feedback. The design considerations for the incubator include spatial arrangement of the energy transfer mechanism, heating capacity of the TE modules, minimum required sample amount for follow-up instrumental or chemical analysis, and the constraint of non-intrusion to the geo-samples during incubation. The performance of the incubator is experimentally evaluated with two tube conditions and under four preset temperature profiles. Test tubes are either empty or filled with quartz sand, which has comparable thermal properties to the materials in the geo-environment. The applied temperature profiles include uniform, constant temperature gradient, monotonic-increasing parabolic, and parabolic. The temperature on the tube wall can be controlled between 20 °C and 90 °C with an averaged root mean squared error of 1 °C.


Electricity , Geological Phenomena , Microbiology/instrumentation , Microtechnology/instrumentation , Temperature , Ecosystem
...