1.
Med Phys ; 2024 May 16.
Article En | MEDLINE | ID: mdl-38753583

BACKGROUND: Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. PURPOSE: A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA). METHODS: Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS). RESULTS: For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. CONCLUSIONS: A detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.

2.
ArXiv ; 2024 Mar 13.
Article En | MEDLINE | ID: mdl-38560739

Background: Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. Purpose: A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA). Methods: Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS). Results: For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. Conclusions: A detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.

3.
J Med Imaging (Bellingham) ; 10(3): 033503, 2023 May.
Article En | MEDLINE | ID: mdl-37292190

Purpose: Motivated by emerging cone-beam computed tomography (CBCT) systems and scan orbits, we aim to quantitatively assess the completeness of data for 3D image reconstruction-in turn, related to "cone-beam artifacts." Fundamental principles of cone-beam sampling incompleteness are considered with respect to an analytical figure-of-merit [FOM, denoted tan(ψmin)] and related to an empirical FOM (denoted zmod) for measurement of cone-beam artifact magnitude in a test phantom. Approach: A previously proposed analytical FOM [tan(ψmin), defined as the minimum angle between a point in the 3D image reconstruction and the x-ray source over the scan orbit] was analyzed for a variety of CBCT geometries. A physical test phantom was configured with parallel disk pairs (perpendicular to the z-axis) at various locations throughout the field of view, quantifying cone-beam artifact magnitude in terms of zmod (the relative signal modulation between the disks). Two CBCT systems were considered: an interventional C-arm (Cios Spin 3D; Siemens Healthineers, Forcheim Germany) and a musculoskeletal extremity scanner; Onsight3D, Carestream Health, Rochester, United States)]. Simulations and physical experiments were conducted for various source-detector orbits: (a) a conventional 360 deg circular orbit, (b) tilted and untilted semi-circular (196 deg) orbits, (c) multi-source (three x-ray sources distributed along the z axis) semi-circular orbits, and (d) a non-circular (sine-on-sphere, SoS) orbit. The incompleteness of sampling [tan(ψmin)] and magnitude of cone-beam artifacts (zmod) were evaluated for each system and orbit. Results: The results show visually and quantitatively the effect of system geometry and scan orbit on cone-beam sampling effects, demonstrating the relationship between analytical tan(ψmin) and empirical zmod. Advanced source-detector orbits (e.g., three-source and SoS orbits) exhibited superior sampling completeness as quantified by both the analytical and the empirical FOMs. The test phantom and zmod metric were sensitive to variations in CBCT system geometry and scan orbit and provided a surrogate measure of underlying sampling completeness. Conclusion: For a given system geometry and source-detector orbit, cone-beam sampling completeness can be quantified analytically (in terms arising from Tuy's condition) and/or empirically (using a test phantom for quantification of cone-beam artifacts). Such analysis provides theoretical and practical insight on sampling effects and the completeness of data for emerging CBCT systems and scan trajectories.

4.
Med Phys ; 50(5): 2607-2624, 2023 May.
Article En | MEDLINE | ID: mdl-36906915

BACKGROUND: Image-guided neurosurgery requires high localization and registration accuracy to enable effective treatment and avoid complications. However, accurate neuronavigation based on preoperative magnetic resonance (MR) or computed tomography (CT) images is challenged by brain deformation occurring during the surgical intervention. PURPOSE: To facilitate intraoperative visualization of brain tissues and deformable registration with preoperative images, a 3D deep learning (DL) reconstruction framework (termed DL-Recon) was proposed for improved intraoperative cone-beam CT (CBCT) image quality. METHODS: The DL-Recon framework combines physics-based models with deep learning CT synthesis and leverages uncertainty information to promote robustness to unseen features. A 3D generative adversarial network (GAN) with a conditional loss function modulated by aleatoric uncertainty was developed for CBCT-to-CT synthesis. Epistemic uncertainty of the synthesis model was estimated via Monte Carlo (MC) dropout. Using spatially varying weights derived from epistemic uncertainty, the DL-Recon image combines the synthetic CT with an artifact-corrected filtered back-projection (FBP) reconstruction. In regions of high epistemic uncertainty, DL-Recon includes greater contribution from the FBP image. Twenty paired real CT and simulated CBCT images of the head were used for network training and validation, and experiments evaluated the performance of DL-Recon on CBCT images containing simulated and real brain lesions not present in the training data. Performance among learning- and physics-based methods was quantified in terms of structural similarity (SSIM) of the resulting image to diagnostic CT and Dice similarity metric (DSC) in lesion segmentation compared to ground truth. A pilot study was conducted involving seven subjects with CBCT images acquired during neurosurgery to assess the feasibility of DL-Recon in clinical data. RESULTS: CBCT images reconstructed via FBP with physics-based corrections exhibited the usual challenges to soft-tissue contrast resolution due to image non-uniformity, noise, and residual artifacts. GAN synthesis improved image uniformity and soft-tissue visibility but was subject to error in the shape and contrast of simulated lesions that were unseen in training. Incorporation of aleatoric uncertainty in synthesis loss improved estimation of epistemic uncertainty, with variable brain structures and unseen lesions exhibiting higher epistemic uncertainty. The DL-Recon approach mitigated synthesis errors while maintaining improvement in image quality, yielding 15%-22% increase in SSIM (image appearance compared to diagnostic CT) and up to 25% increase in DSC in lesion segmentation compared to FBP. Clear gains in visual image quality were also observed in real brain lesions and in clinical CBCT images. CONCLUSIONS: DL-Recon leveraged uncertainty estimation to combine the strengths of DL and physics-based reconstruction and demonstrated substantial improvements in the accuracy and quality of intraoperative CBCT. The improved soft-tissue contrast resolution could facilitate visualization of brain structures and support deformable registration with preoperative images, further extending the utility of intraoperative CBCT in image-guided neurosurgery.


Deep Learning , Humans , Pilot Projects , Uncertainty , Cone-Beam Computed Tomography/methods , Brain/diagnostic imaging , Brain/surgery , Image Processing, Computer-Assisted/methods , Algorithms
5.
Med Phys ; 49(11): 6840-6855, 2022 Nov.
Article En | MEDLINE | ID: mdl-35880711

PURPOSE: To investigate the effects of subject motion and gantry rotation speed on computed tomography (CT) image quality over a range of image acquisition speeds for fan-beam (FB) and cone-beam (CB) CT scanners, and quantify the geometric and dosimetric errors introduced by FB and CB sampling in the context of adaptive radiotherapy. METHODS: Images of motion phantoms were acquired using four CT scanners with gantry rotation speeds of 0.5 s/rotation (denoted FB-0.5), 1.9 s/rotation (FB-1.9), 16.6 s/rotation (CB-16.6), and 60.0 s/rotation (CB-60.0). A phantom presenting various tissue densities undergoing motion with 4-s period and ranging in amplitude from ±0.5 to ±10.0 mm was used to characterize motion artifacts (streaks), motion blur (edge-spread function, ESF), and geometric inaccuracy (excursion of insert centroids and distortion of known shape). An anthropomorphic abdomen phantom undergoing ±2.5-mm motion with 4-s period was used to simulate an adaptive radiotherapy workflow, and relative geometric and dosimetric errors were compared between scanners. RESULTS: At ±2.5-mm motion, phantom measurements demonstrated mean ± SD ESF widths of 0.6 ± 0.0, 1.3 ± 0.4, 2.0 ± 1.1, and 2.9 ± 2.0 mm and geometric inaccuracy (excursion) of 2.7 ± 0.4, 4.1 ± 1.2, 2.6 ± 0.7, and 2.0 ± 0.5 mm for the FB-0.5, FB-1.9, CB-16.6, and CB-60.0 scanners, respectively. The results demonstrated nonmonotonic trends with scanner speed for FB and CB geometries. Geometric and dosimetric errors in adaptive radiotherapy plans were largest for the slowest (CB-60.0) scanner and similar for the three faster systems (CB-16.6, FB-1.9, and FB-0.5). CONCLUSIONS: Clinically standard CB-60.0 demonstrates strong image quality degradation in the presence of subject motion, which is mitigated through faster CBCT or FBCT. Although motion blur is minimized for FB-0.5 and FB-1.9, such systems suffer from increased geometric distortion compared to CB-16.6. Each system reflects tradeoffs in image artifacts and geometric inaccuracies that affect treatment delivery/dosimetric error and should be considered in the design of next-generation CT-guided radiotherapy systems.


Tomography, X-Ray Computed
6.
IEEE Trans Med Robot Bionics ; 4(1): 28-37, 2022 Feb.
Article En | MEDLINE | ID: mdl-35368731

Conventional neuro-navigation can be challenged in targeting deep brain structures via transventricular neuroendoscopy due to unresolved geometric error following soft-tissue deformation. Current robot-assisted endoscopy techniques are fairly limited, primarily serving to planned trajectories and provide a stable scope holder. We report the implementation of a robot-assisted ventriculoscopy (RAV) system for 3D reconstruction, registration, and augmentation of the neuroendoscopic scene with intraoperative imaging, enabling guidance even in the presence of tissue deformation and providing visualization of structures beyond the endoscopic field-of-view. Phantom studies were performed to quantitatively evaluate image sampling requirements, registration accuracy, and computational runtime for two reconstruction methods and a variety of clinically relevant ventriculoscope trajectories. A median target registration error of 1.2 mm was achieved with an update rate of 2.34 frames per second, validating the RAV concept and motivating translation to future clinical studies.

7.
J Med Imaging (Bellingham) ; 8(3): 035001, 2021 May.
Article En | MEDLINE | ID: mdl-34124283

Purpose: A method for fluoroscopic guidance of a robotic assistant is presented for instrument placement in pelvic trauma surgery. The solution uses fluoroscopic images acquired in standard clinical workflow and helps avoid repeat fluoroscopy commonly performed during implant guidance. Approach: Images acquired from a mobile C-arm are used to perform 3D-2D registration of both the patient (via patient CT) and the robot (via CAD model of a surgical instrument attached to its end effector, e.g; a drill guide), guiding the robot to target trajectories defined in the patient CT. The proposed approach avoids C-arm gantry motion, instead manipulating the robot to acquire disparate views of the instrument. Phantom and cadaver studies were performed to determine operating parameters and assess the accuracy of the proposed approach in aligning a standard drill guide instrument. Results: The proposed approach achieved average drill guide tip placement accuracy of 1.57 ± 0.47 mm and angular alignment of 0.35 ± 0.32 deg in phantom studies. The errors remained within 2 mm and 1 deg in cadaver experiments, comparable to the margins of errors provided by surgical trackers (but operating without the need for external tracking). Conclusions: By operating at a fixed fluoroscopic perspective and eliminating the need for encoded C-arm gantry movement, the proposed approach simplifies and expedites the registration of image-guided robotic assistants and can be used with simple, non-calibrated, non-encoded, and non-isocentric C-arm systems to accurately guide a robotic device in a manner that is compatible with the surgical workflow.

8.
Med Phys ; 48(6): 2772-2789, 2021 Jun.
Article En | MEDLINE | ID: mdl-33660261

PURPOSE: The modulation transfer function (MTF) is widely used as an objective metric of spatial resolution of medical imaging systems. Despite advances in capability for three-dimensional (3D) isotropic spatial resolution in computed tomography (CT) and cone-beam CT (CBCT), MTF evaluation for such systems is typically reported only in the axial plane, and practical methodology for assessment of fully 3D spatial resolution characteristics is lacking. This work reviews fundamental theoretical relationships of two-dimensional (2D) and 3D spread functions and reports practical methods and test tools for analysis of 3D MTF in CBCT. METHODS: Fundamental aspects of 2D and 3D MTF measurement are reviewed within a common notational framework, and three MTF test tools with analysis code are reported and made available online (https://istar.jhu.edu/downloads/): (a) a multi-wire tool for measurement of the axial plane MTF [denoted as M T F ( f r ; φ = 0 ∘ ) , where φ is the measurement angle out of the axial plane] as a function of position in the axial plane; (b) a wedge tool for measurement of the MTF in any direction in the 3D Fourier domain [e.g.,  φ  = 45°, denoted as M T F ( f r ; φ = 45 ∘ ) ]; and (c) a sphere tool for measurement of the MTF in any or all directions in the 3D Fourier domain. Experiments were performed on a mobile C-arm with CBCT capability, showing that M T F ( f r ; φ = 45 ∘ ) yields an informative one-dimensional (1D) representation of the overall 3D spatial resolution characteristics, capturing important characteristics of the 3D MTF that might be missed in conventional analysis. The effects of anisotropic filters and detector readout mode were investigated, and the extent to which a system can be said to provide "isotropic" resolution was evaluated by quantitative comparison of MTF at various φ . RESULTS: All three test tools provided consistent measurement of M T F ( f r ; φ = 0 ∘ ) , and the wedge and sphere tools demonstrated how measurement of the MTF in directions outside the axial plane ( φ > 0 ∘ ) can reveal spatial resolution characteristics to which conventional axial MTF measurement is blind. The wedge tool was shown to reduce statistical measurement error compared to the sphere tool due to improved sampling, and the sphere tool was shown to provide a basis for measurement of the MTF in any or all directions (outside the null cone) from a single scan. The C-arm system exhibited non-isotropic spatial resolution with conventional non-isotropic 1D apodization filters (i.e., frequency cutoff filters) - which is common in CBCT - and implementation of isotropic 2D apodization yielded quantifiably isotropic MTF. Asymmetric pixel binning modes were similarly shown to impart non-isotropic effects on the 3D MTF, and the overall 3D MTF characteristics were evident in each case with a single, 1D measurement of the 1D M T F ( f r ; φ = 45 ∘ ). CONCLUSION: Three test tools and corresponding MTF analysis methods were presented within a consistent framework for analysis of 3D spatial resolution characteristics in a manner amenable to routine, practical measurements. Experiments on a CBCT C-arm validated many intuitive aspects of 3D spatial resolution and quantified the extent to which a CBCT system may be considered to have isotropic resolution. Measurement of M T F ( f r ; φ = 45 ∘ ) provided a practical 1D measure of the underlying 3D MTF characteristics and is extensible to other CT or CBCT systems offering high, isotropic spatial resolution.


Cone-Beam Computed Tomography , Tomography, X-Ray Computed , Phantoms, Imaging
9.
J Med Imaging (Bellingham) ; 8(5): 052103, 2021 Sep.
Article En | MEDLINE | ID: mdl-33732755

Purpose: Cone-beam computed tomography (CBCT) is commonly used in the operating room to evaluate the placement of surgical implants in relation to critical anatomical structures. A particularly problematic setting, however, is the imaging of metallic implants, where strong artifacts can obscure visualization of both the implant and surrounding anatomy. Such artifacts are compounded when combined with low-dose imaging techniques such as sparse-view acquisition. Approach: This work presents a dual convolutional neural network approach, one operating in the sinogram domain and one in the reconstructed image domain, that is specifically designed for the physics and setting of intraoperative CBCT to address the sources of beam hardening and sparse view sampling that contribute to metal artifacts. The networks were trained with images from cadaver scans with simulated metal hardware. Results: The trained networks were tested on images of cadavers with surgically implanted metal hardware, and performance was compared with a method operating in the image domain alone. While both methods removed most image artifacts, superior performance was observed for the dual-convolutional neural network (CNN) approach in which beam-hardening and view sampling effects were addressed in both the sinogram and image domain. Conclusion: The work demonstrates an innovative approach for eliminating metal and sparsity artifacts in CBCT using a dual-CNN framework which does not require a metal segmentation.

10.
Med Phys ; 48(6): 2760-2771, 2021 Jun.
Article En | MEDLINE | ID: mdl-33608927

PURPOSE: The purpose of this study was to quantify location and direction-dependent variations in the 3D modulation transfer function (MTF) of a high-resolution CT scanner with selectable focal spot sizes and resolution modes. METHODS: The Aquilion Precision CT scanner (Canon Medical Systems) has selectable 0.25 mm or 0.5 mm detectors (by binning) in both the axial (x-y) and detector array width (z) directions. For the x-y and z orientations, detectors are configured (x-y) = 0.5 mm/(z) = 0.5 mm for normal resolution (NR), 0.25/0.5 mm for high resolution (HR), and 0.25/0.25 mm for super high resolution (SHR). Six focal spots (FS1-FS6) range in size from 0.4 (x-y) × 0.5 mm (z) for FS1 to 1.6 × 1.4 mm for FS6. Phantoms fabricated from spherical objects were positioned at radial distances of 0, 4.0, 7.5, 11.0, 14.5, and 18.5 cm. Axial and helical acquisitions were utilized and reconstructed using filtered back projection with the FC18 "Body," FC30 "Bone," and FC81 "Bone Sharp" kernels. The reconstructions were used to measure a 1D slice of the 3D MTF by oversampling the 3D ESF in the axial plane [MTF(fr ); φ = 0°)], 45° out of the axial plane [MTF(fr ); φ = 45°)], in the longitudinal direction [MTF(fr ); φ = 80°)], and along the radial and azimuthal directions within the axial plane. RESULTS: The MTF(fr ); φ = 45°) drops to 10% (f10 ) at 1.20, 1.45, and 2.06 mm-1 for NR, HR, and SHR, respectively, for a helical acquisition with FS1, FC30, and r = 4 cm from the isocenter. The MTF(fr ); φ = 45°) includes contributions of both the axial-plane MTF (f10  = 1.10, 2.04, and 2.01 mm-1 ) and the longitudinal MTF (f10  = 1.17, 1.18, and 1.82 mm-1 ) for the NR, HR, and SHR modes, respectively. For SHR, the axial scan mode showed a 15-25% improvement over helical mode in the longitudinal resolution. Helical pitch, ranging from 0.569 to 1.381, did not appreciably affect the 3D resolution (<2%). The radial MTFs across the axial field of view (FOV) showed dependencies on the focal spot length in z; for example, for SHR with FS2 (0.6 × 0.6 mm), f10 at  r = 11 cm was within 17% of the value at r = 4 cm, but for SHR with FS3 (0.6 × 1.3), the reduction in f10 was 46% from 4 to 11 cm from the isocenter. The azimuthal MTF also decreased as r increased but less so for longer gantry rotation times and smaller focal spot dimensions in the axial plane. The longitudinal MTF was minimally affected (<11%) by position in the FOV and was principally affected by the focal spot length in the z-dimension. CONCLUSIONS: The 3D MTF was measured throughout the FOV of a high-resolution CT scanner, quantifying the advantages of different resolution modes and focal spot sizes on the axial-plane and longitudinal MTF. Reconstruction kernels were shown to impact axial-plane resolution, imparting non-isotropic 3D resolution characteristics. Focal spot size (both in x-y and in z) and gantry rotation time play important roles in preserving the high-resolution characteristics throughout the field of view for this new high-resolution CT scanner technology.


Bone and Bones , Tomography, X-Ray Computed , Phantoms, Imaging , Tomography Scanners, X-Ray Computed
11.
Phys Med Biol ; 66(5): 055008, 2021 02 17.
Article En | MEDLINE | ID: mdl-33477120

PURPOSE: A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. METHODS: A multi-slot collimator with tilted apertures was integrated into an O-arm system for long-length imaging. The multi-slot projective geometry leads to slight view disparity in both long-length projection images (referred to as 'line scans') and tomosynthesis 'slot reconstructions' produced using a weighted-backprojection method. The radiation dose for long-length imaging was measured, and the utility of long-length, intraoperative tomosynthesis was evaluated in phantom and cadaver studies. Leveraging the depth resolution provided by parallax views, an algorithm for 3D-2D registration of the patient and surgical devices was adapted for registration with line scans and slot reconstructions. Registration performance using single-plane or dual-plane long-length images was evaluated and compared to registration accuracy achieved using standard dual-plane radiographs. RESULTS: Longitudinal coverage of ∼50-64 cm was achieved with a single long-length slot scan, providing a field-of-view (FOV) up to (40 × 64) cm2, depending on patient positioning. The dose-area product (reference point air kerma × x-ray field area) for a slot scan ranged from ∼702-1757 mGy·cm2, equivalent to ∼2.5 s of fluoroscopy and comparable to other long-length imaging systems. Long-length scanning produced high-resolution tomosynthesis reconstructions, covering ∼12-16 vertebral levels. 3D image registration using dual-plane slot reconstructions achieved median target registration error (TRE) of 1.2 mm and 0.6° in cadaver studies, outperforming registration to dual-plane line scans (TRE = 2.8 mm and 2.2°) and radiographs (TRE = 2.5 mm and 1.1°). 3D registration using single-plane slot reconstructions leveraged the ∼7-14° angular separation between slots to achieve median TRE ∼2 mm and <2° from a single scan. CONCLUSION: The multi-slot configuration provided intraoperative visualization of long spine segments, facilitating target localization, assessment of global spinal alignment, and evaluation of long surgical constructs. 3D-2D registration to long-length tomosynthesis reconstructions yielded a promising means of guidance and verification with accuracy exceeding that of 3D-2D registration to conventional radiographs.


Imaging, Three-Dimensional/methods , Spine/diagnostic imaging , Spine/surgery , Surgery, Computer-Assisted , Tomography , Algorithms , Fluoroscopy , Humans , Intraoperative Period , Phantoms, Imaging
12.
J Appl Clin Med Phys ; 20(10): 187-200, 2019 Oct.
Article En | MEDLINE | ID: mdl-31578811

PURPOSE: The imaging performance and dose of a mobile CT scanner (Brainlab Airo®, Munich, Germany) is evaluated, with particular consideration to assessment of technique protocols for image-guided brachytherapy. METHOD: Dose measurements were performed using a 100-mm-length pencil chamber at the center and periphery of 16- and 32-cm-diameter CTDI phantoms. Hounsfield unit (HU) accuracy and linearity were assessed using materials of specified electron density (Gammex RMI, Madison, WI), and image uniformity, noise, and noise-power spectrum (NPS) were evaluated in a 20-cm-diameter water phantom as well as an American College of Radiology (ACR) CT accreditation phantom (Model 464, Sun Nuclear, Melbourne, FL). Spatial resolution (modulation transfer function, MTF) was assessed with an edge-spread phantom and visually assessed with respect to line-pair patterns in the ACR phantom and in structures of interest in anthropomorphic phantoms. Images were also obtained on a diagnostic CT scanner (Big Bore CT simulator, Philips, Amsterdam, Netherlands) for qualitative and quantitative comparison. The manufacturer's metal artifact reduction (MAR) algorithm was assessed in an anthropomorphic body phantom containing surgical instrumentation. Performance in application to brachytherapy was assessed with a set of anthropomorphic brachytherapy phantoms - for example, a vaginal cylinder and interstitial ring and tandem. RESULT: Nominal dose for helical and axial modes, respectively, was 56.4 and 78.9 mGy for the head protocol and 17.8 and 24.9 mGy for the body protocol. A high degree of HU accuracy and linearity was observed for both axial and helical scan modes. Image nonuniformity (e.g., cupping artifact) in the transverse (x,y) plane was less than 5 HU, but stitching artifacts (~5 HU) in the longitudinal (z) direction were observed in axial scan mode. Helical and axial modes demonstrated comparable spatial resolution of ~5 lp/cm, with the MTF reduced to 10% at ~0.38 mm-1 . Contrast-to-noise ratio was suitable to soft-tissue visualization (e.g., fat and muscle), but windmill artifacts were observed in helical mode in relation to high-frequency bone and metal. The MAR algorithm provided modest improvement to image quality. Overall, image quality appeared suitable to relevant clinical tasks in intracavitary and interstitial (e.g., gynecological) brachytherapy, including visualization of soft-tissue structures in proximity to the applicators. CONCLUSION: The technical assessment highlighted key characteristics of dose and imaging performance pertinent to incorporation of the mobile CT scanner in clinical procedures, helping to inform clinical deployment and technique protocol selection in brachytherapy. For this and other possible applications, the work helps to identify protocols that could reduce radiation dose and/or improve image quality. The work also identified areas for future improvement, including reduction of stitching, windmill, and metal artifacts.


Brachytherapy/instrumentation , Organs at Risk/radiation effects , Phantoms, Imaging , Radiotherapy, Image-Guided/instrumentation , Signal-To-Noise Ratio , Tomography Scanners, X-Ray Computed/statistics & numerical data , Tomography, X-Ray Computed/instrumentation , Algorithms , Brachytherapy/methods , Humans , Image Processing, Computer-Assisted/methods , Radiotherapy Dosage , Tomography, X-Ray Computed/methods
13.
Phys Med Biol ; 62(22): 8495-8520, 2017 Oct 27.
Article En | MEDLINE | ID: mdl-29077573

Recent advances in total variation (TV) technology enable accurate CT image reconstruction from highly under-sampled and noisy projection data. The standard iterative reconstruction algorithms, which work well in conventional CT imaging, fail to perform as expected in cone beam CT (CBCT) applications, wherein the non-ideal physics issues, including scatter and beam hardening, are more severe. These physics issues result in large areas of shading artifacts and cause deterioration to the piecewise constant property assumed in reconstructed images. To overcome this obstacle, we incorporate a shading correction scheme into low-dose CBCT reconstruction and propose a clinically acceptable and stable three-dimensional iterative reconstruction method that is referred to as the shading correction assisted iterative reconstruction. In the proposed method, we modify the TV regularization term by adding a shading compensation image to the reconstructed image to compensate for the shading artifacts while leaving the data fidelity term intact. This compensation image is generated empirically, using image segmentation and low-pass filtering, and updated in the iterative process whenever necessary. When the compensation image is determined, the objective function is minimized using the fast iterative shrinkage-thresholding algorithm accelerated on a graphic processing unit. The proposed method is evaluated using CBCT projection data of the Catphan© 600 phantom and two pelvis patients. Compared with the iterative reconstruction without shading correction, the proposed method reduces the overall CT number error from around 200 HU to be around 25 HU and increases the spatial uniformity by a factor of 20 percent, given the same number of sparsely sampled projections. A clinically acceptable and stable iterative reconstruction algorithm for CBCT is proposed in this paper. Differing from the existing algorithms, this algorithm incorporates a shading correction scheme into the low-dose CBCT reconstruction and achieves more stable optimization path and more clinically acceptable reconstructed image. The method proposed by us does not rely on prior information and thus is practically attractive to the applications of low-dose CBCT imaging in the clinic.


Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Pelvic Neoplasms/diagnostic imaging , Phantoms, Imaging , Radionuclide Imaging/methods , Algorithms , Artifacts , Humans
14.
Phys Med Biol ; 60(21): 8437-55, 2015 Nov 07.
Article En | MEDLINE | ID: mdl-26464343

Shading artifacts in CT images are caused by scatter contamination, beam-hardening effect and other non-ideal imaging conditions. The purpose of this study is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT images (e.g. cone-beam CT, low-kVp CT) without relying on prior information. The method is based on the general knowledge of the relatively uniform CT number distribution in one tissue component. The CT image is first segmented to construct a template image where each structure is filled with the same CT number of a specific tissue type. Then, by subtracting the ideal template from the CT image, the residual image from various error sources are generated. Since forward projection is an integration process, non-continuous shading artifacts in the image become continuous signals in a line integral. Thus, the residual image is forward projected and its line integral is low-pass filtered in order to estimate the error that causes shading artifacts. A compensation map is reconstructed from the filtered line integral error using a standard FDK algorithm and added back to the original image for shading correction. As the segmented image does not accurately depict a shaded CT image, the proposed scheme is iterated until the variation of the residual image is minimized. The proposed method is evaluated using cone-beam CT images of a Catphan©600 phantom and a pelvis patient, and low-kVp CT angiography images for carotid artery assessment. Compared with the CT image without correction, the proposed method reduces the overall CT number error from over 200 HU to be less than 30 HU and increases the spatial uniformity by a factor of 1.5. Low-contrast object is faithfully retained after the proposed correction. An effective iterative algorithm for shading correction in CT imaging is proposed that is only assisted by general anatomical information without relying on prior knowledge. The proposed method is thus practical and attractive as a general solution to CT shading correction.


Algorithms , Cone-Beam Computed Tomography/methods , Humans , Pelvis/diagnostic imaging , Phantoms, Imaging , Scattering, Radiation
...