Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
BMC Ophthalmol ; 24(1): 341, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39138420

RESUMEN

BACKGROUNDS: Iris nodules are frequently noted as clinical manifestations of neurofibromatosis type 1 but the other intraocular manifestations are rare. The purpose of this study is to present a patient with a phthisic eye who underwent enucleation for a cosmetic reason after 15-year follow-up and also to review 14 patients with enucleation described in the literature. CASE PRESENTATION: A 17-year-old man with neurofibromatosis type 1 from infancy underwent the enucleation of phthisic left eye and also had the resection of eyelid subcutaneous mass lesions on the left side for a cosmetic reason. He had undergone four-time preceding surgeries for eyelid and orbital mass reduction on the left side in childhood and had developed total retinal detachment 10 years previously. Pathologically, the enucleated eye showed massive retinal gliosis positive for both S-100 and glial fibrillary acidic protein (GFAP) in the area with involvement of the detached retinal neuronal layer, together with a more fibrotic lesion along the choroid which were, in contrast, negative for both S-100 and GFAP. The choroid, ciliary body, and iris did not show apparent neurofibroma while episcleral neurofibroma was present. LITERATURE REVIEW: In review of enucleated eyes of 14 patients in the literature, buphthalmic eyes with early-onset glaucoma on the unilateral side was clinically diagnosed in 9 patients who frequently showed varying extent of hemifacial neurofibromatosis which involved the eyelid and orbit on the same side. Pathologically, neurofibromas in varying extent were found in the choroid of 12 patients. One patient showed choroidal malignant melanoma on the left side and fusiform enlargement of the optic nerve on the right side suspected of optic nerve glioma. The phthisic eye in another patient showed massive retinal gliosis similar to the present patient. CONCLUSIONS: In summary of the 15 patients with neurofibromatosis type 1, including the present patient, buphthalmic or phthisic eyes with no vision were enucleated for cosmetic reasons and showed choroidal neurofibroma in most patients and massive retinal gliosis in two patients including the present patient.


Asunto(s)
Enucleación del Ojo , Neurofibromatosis 1 , Humanos , Masculino , Adolescente , Neurofibromatosis 1/complicaciones , Neurofibromatosis 1/diagnóstico , Neurofibromatosis 1/patología , Estudios de Seguimiento
2.
Sci Rep ; 14(1): 3792, 2024 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-38360913

RESUMEN

In onion thrips Thrips tabaci, reduced sensitivity of the sodium channel caused by several sodium channel mutations have been correlated with pyrethroid resistance. For this study, using mitochondrial cytochrome c oxidase subunit I gene sequences, we examined the phylogenetic relation among a total of 52 thelytokous and arrhenotokous strains with different genotypes of the sodium channel mutations. Then, we used flow cytometry to estimate their ploidy. Results showed that the strains are divisible into three groups: diploid thelytoky, triploid thelytoky, and diploid arrhenotoky. Using 23 whole genome resequencing data obtained from 20 strains out of 52, we examined their genetic relation further using principal component analysis, admixture analysis, and a fixation index. Results showed that diploid and triploid thelytokous groups are further classifiable into two based on the sodium channel mutations harbored by the respective group members (strains). The greatest genetic divergence was observed between thelytokous and arrhenotokous groups with a pair of T929I and K1774N. Nevertheless, they shared a genomic region with virtually no polymorphism around the sodium channel gene loci, suggesting a hard selective sweep. Based on these findings, we discuss the evolutionary origin and distribution of the sodium channel mutations in T. tabaci.


Asunto(s)
Thysanoptera , Animales , Cebollas , Filogenia , Triploidía , Aminoácidos/metabolismo , Mutación , Canales de Sodio/metabolismo
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(2): 207-215, 2024 Feb 20.
Artículo en Japonés | MEDLINE | ID: mdl-38148020

RESUMEN

PURPOSE: We created a phantom and analysis program for the assessment of IGRT positional accuracy. We verified the accuracy of analysis and the practicality of this evaluation method at several facilities. METHOD: End-to-end test was performed using an in-house phantom, and EPID images were acquired after displacement by an arbitrary amount using a micrometer, with after image registration as the reference. The difference between the center of the target and the irradiated field was calculated using our in-house analysis program and commercial software. The end-to-end test was conducted at three facilities, and the IGRT positional accuracy evaluation was verified. RESULT: The maximum difference between the displacement of the target determined from the EPID image and the arbitrary amount of micrometer displacement was 0.24 mm for the in-house analysis program and 0.30 mm for the commercial software. The maximum difference between the center of the target and the irradiation field on EPID images acquired at the three facilities was 0.97 mm. CONCLUSION: The proposed evaluation method using our in-house phantom and analysis program can be used for the assessment of IGRT positional accuracy.


Asunto(s)
Radioterapia Guiada por Imagen , Radioterapia Guiada por Imagen/métodos , Fantasmas de Imagen , Programas Informáticos
4.
Med Phys ; 51(3): 1571-1582, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38112216

RESUMEN

BACKGROUND: Inadequate computed tomography (CT) number calibration curves affect dose calculation accuracy. Although CT number calibration curves registered in treatment planning systems (TPSs) should be consistent with human tissues, it is unclear whether adequate CT number calibration is performed because CT number calibration curves have not been assessed for various types of CT number calibration phantoms and TPSs. PURPOSE: The purpose of this study was to investigate CT number calibration curves for mass density (ρ) and relative electron density (ρe ). METHODS: A CT number calibration audit phantom was sent to 24 Japanese photon therapy institutes from the evaluating institute and scanned using their individual clinical CT scan protocols. The CT images of the audit phantom and institute-specific CT number calibration curves were submitted to the evaluating institute for analyzing the calibration curves registered in the TPSs at the participating institutes. The institute-specific CT number calibration curves were created using commercial phantom (Gammex, Gammex Inc., Middleton, WI, USA) or CIRS phantom (Computerized Imaging Reference Systems, Inc., Norfolk, VA, USA)). At the evaluating institute, theoretical CT number calibration curves were created using a stoichiometric CT number calibration method based on the CT image, and the institute-specific CT number calibration curves were compared with the theoretical calibration curve. Differences in ρ and ρe over the multiple points on the curve (Δρm and Δρe,m , respectively) were calculated for each CT number, categorized for each phantom vendor and TPS, and evaluated for three tissue types: lung, soft tissues, and bones. In particular, the CT-ρ calibration curves for Tomotherapy TPSs (ACCURAY, Sunnyvale, CA, USA) were categorized separately from the Gammex CT-ρ calibration curves because the available tissue-equivalent materials (TEMs) were limited by the manufacturer recommendations. In addition, the differences in ρ and ρe for the specific TEMs (ΔρTEM and Δρe,TEM , respectively) were calculated by subtracting the ρ or ρe of the TEMs from the theoretical CT-ρ or CT-ρe calibration curve. RESULTS: The mean ± standard deviation (SD) of Δρm and Δρe,m for the Gammex phantom were -1.1 ± 1.2 g/cm3 and -0.2 ± 1.1, -0.3 ± 0.9 g/cm3 and 0.8 ± 1.3, and -0.9 ± 1.3 g/cm3 and 1.0 ± 1.5 for lung, soft tissues, and bones, respectively. The mean ± SD of Δρm and Δρe,m for the CIRS phantom were 0.3 ± 0.8 g/cm3 and 0.9 ± 0.9, 0.6 ± 0.6 g/cm3 and 1.4 ± 0.8, and 0.2 ± 0.5 g/cm3 and 1.6 ± 0.5 for lung, soft tissues, and bones, respectively. The mean ± SD of Δρm for Tomotherapy TPSs was 2.1 ± 1.4 g/cm3 for soft tissues, which is larger than those for other TPSs. The mean ± SD of Δρe,TEM for the Gammex brain phantom (BRN-SR2) was -1.8 ± 0.4, implying that the tissue equivalency of the BRN-SR2 plug was slightly inferior to that of other plugs. CONCLUSIONS: Latent deviations between human tissues and TEMs were found by comparing the CT number calibration curves of the various institutes.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Calibración , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Cabeza , Huesos , Fantasmas de Imagen
5.
Clin Case Rep ; 11(12): e8364, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38130855

RESUMEN

Key Clinical Message: It is important to stain acid-fact bacilli on the smear of abscess puncture in addition to Gram stain to detect nontuberculous and tuberculous mycobacteria in the early phase since both can cause rare and challenging extrapulmonary manifestations. Abstract: A 56-year-old otherwise healthy woman developed abscess from dacryocystitis in the right lower eyelid. The smear of puncture fluid showed acid-fast bacilli and Mycobacterium abscessus was identified after a month. The early start of clarithromycin/ethambutol was switched to clarithromycin/levofloxacin. Debridement specimen after 7-month treatment showed granulomatous tissue with no bacilli.

6.
Med Phys ; 50(4): 2488-2498, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36609669

RESUMEN

BACKGROUND: Artificial intelligence (AI)-based gamma passing rate (GPR) prediction has been proposed as a time-efficient virtual patient-specific QA method for the delivery of volumetric modulation arc therapy (VMAT). However, there is a limitation that the GPR value loses the locational information of dose accuracy. PURPOSE: The objective was to predict the failing points in the gamma distribution and the GPR using a synthesized gamma distribution of VMAT QA with a deep convolutional generative adversarial network (GAN). METHODS: The fluence maps of 270 VMAT beams for prostate cancer were measured using an electronic portal imaging device and analyzed using gamma evaluation with 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances. The 270 gamma distributions were divided into two datasets: 240 training datasets for creating a model and 30 test datasets for evaluation. The image prediction network for the fluence maps calculated by the treatment planning system (TPS) to the gamma distributions was created using a GAN. The sensitivity, specificity, and accuracy of detecting failing points were evaluated using measured and synthesized gamma distributions. In addition, the difference between measured GPR (mGPR) and predicted GPR (pGPR) values calculated from the synthesized gamma distributions was evaluated. RESULTS: The root mean squared errors between mGPR and pGPR were 1.0%, 2.1%, 3.5%, and 3.6% for the 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances, respectively. The accuracies for detecting failing points were 98.9%, 96.9%, 94.7%, and 93.7% for 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances, respectively. The sensitivity and specificity were the highest for 1%/0.5-mm and 3%/2-mm tolerances, which were 82.7% and 99.6%, respectively. CONCLUSIONS: We developed a novel system using a GAN to generate a synthesized gamma distribution-based patient-specific VMAT QA. The system is promising from the point of view of quality assurance in radiotherapy because it shows high performance and can detect failing points.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Radioterapia de Intensidad Modulada/métodos , Inteligencia Artificial , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Garantía de la Calidad de Atención de Salud
7.
Acta Med Okayama ; 76(5): 597-603, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36352808

RESUMEN

Gender affirming surgery (GAS) has important impacts for people with gender incongruence (GI), both physically and socially. As the societal acceptance of gender diversity spreads, the number of individuals with GI who wish to be identified as the gender of their choice is increasing. Indeed, many elderly people who have lived a long time with GI now wish to undergo GAS, but face greater surgical risks due to greater burdens of underlying medical conditions. Generally, vaginoplasty is performed for transwomen; however, this surgery is time-consuming and involves heavy bleeding, and thus, should be avoided in elderly people. A less invasive technique is needed. In this article, we describe a new, less invasive genital feminizing surgical technique for transwomen with reports from two clinical cases. We present this novel technique as a safe, aesthetic, and cost-effective option for gender-affirming surgery for transwomen.


Asunto(s)
Cirugía de Reasignación de Sexo , Personas Transgénero , Femenino , Humanos , Anciano , Análisis Costo-Beneficio , Cirugía de Reasignación de Sexo/métodos , Estética , Genitales
8.
Cytotechnology ; 74(6): 623-634, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36389282

RESUMEN

To reduce the immunogenicity of ß-lactoglobulin (BLG), we prepared single amino acid substituted recombinant BLG mutants (BLG/P126A, BLG/V128D and BLG/D129A) in the methylotrophic yeast Pichia Pastris by fusion of the cDNA to the sequence coding for the α-factor signal peptide from Saccharomyces cerevisiae. Isoelectric points of single amino acid substituted BLGs were lower than that of native BLG. CD spectra indicated that the secondary structure of BLG had maintained native structure in single amino acid substituted BLGs. Fluorescence studies indicated that the conformation around Trp had not changed in single amino acid substituted BLGs. Anti-BLG antibody response was evaluated after immunization to C57BL/6 mice. Antibody response was reduced after immunization with BLG/P126A, BLG/V128D and BLG/D129A. And novel immunogenicity was not observed in the experiments. T cell proliferative response was evaluated in C57BL/6 mice, and it was clarified that BLG mutants also showed low response. Methods employed in this study was considered to be very effective to reduce immunogenicity of BLG.

9.
Phys Eng Sci Med ; 45(4): 1073-1081, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36202950

RESUMEN

To predict the gamma passing rate (GPR) of the three-dimensional (3D) detector array-based volumetric modulated arc therapy (VMAT) quality assurance (QA) for prostate cancer using a convolutional neural network (CNN) with the 3D dose distribution. One hundred thirty-five VMAT plans for prostate cancer were selected: 110 plans were used for training and validation, and 25 plans were used for testing. Verification plans were measured using a helical 3D diode array (ArcCHECK). The dose distribution on the detector element plane of these verification plans was used as input data for the CNN model. The measured GPR (mGPR) values were used as the training data. The CNN model comprises eighteen layers and predicted GPR (pGPR) values. The mGPR and pGPR values were compared, and a cumulative frequency histogram of the prediction error was created to clarify the prediction error tendency. The correlation coefficients of pGPR and mGPR were 0.67, 0.69, 0.66, and 0.73 for 3%/3-mm, 3%/2-mm, 2%/3-mm, and 2%/2-mm gamma criteria, respectively. The respective mean±standard deviations of pGPR-mGPR were -0.87±2.18%, -0.65±2.93%, -0.44±2.53%, and -0.71±3.33%. The probabilities of false positive error cases (pGPR < mGPR) were 72%, 60%, 68%, and 56% for each gamma criterion. We developed a deep learning-based prediction model of the 3D detector array-based VMAT QA for prostate cancer, and evaluated the accuracy and tendency of prediction GPR. This model can provide a proactive estimation for the results of the patient-specific QA before the verification measurement.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Garantía de la Calidad de Atención de Salud , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia
10.
Phys Med ; 99: 22-30, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35605415

RESUMEN

PURPOSE: Treatment planning for ion therapy involves the conversion of computed tomography number (CTN) into a stopping-power ratio (SPR) relative to water. The purpose of this study was to create a CTN-to-SPR calibration table using a stoichiometric CTN calibration model with a three-parameter fit model for ion therapy, and to demonstrate its effectiveness by comparing it with a conventional stoichiometric CTN calibration model. METHODS: We inserted eight tissue-equivalent materials into a CTN calibration phantom and used six CT scanners at five radiotherapy institutes to scan the phantom. We compared the theoretical CTN-to-SPR calibration tables created using the three-parameter fit and conventional models to the measured CTN-to-SPR calibration table in three tissue types: lung, adipose/muscle, and cartilage/spongy bone. We validated the estimated SPR differences in all cases and in a worst-case scenario, which revealed the largest estimated SPR difference in lung tissue. RESULTS: For all cases, the means ± standard deviations of the estimated SPR difference for the three-parameter fit method model were -0.1 ± 1.0%, 0.3 ± 0.7%, and 2.4 ± 0.6% for the lung, adipose/muscle, and cartilage/spongy bone, respectively. For the worst-case scenario, the estimated SPR differences of the conventional and the three-parameter fit models were 2.9% and -1.4% for the lung tissue, respectively. CONCLUSIONS: The CTN-to-SPR calibration table of the three-parameter fit model was consistent with that of the measurement and decreased the calibration error for low-density tissues, even for the worst-case scenario.


Asunto(s)
Tomografía Computarizada por Rayos X , Agua , Calibración , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos
11.
Sci Rep ; 12(1): 309, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013357

RESUMEN

Most protocols for lymphatic imaging of the lower limb conventionally inject tracer materials only into the interdigital space; however, recent studies indicate that there are four independent lymphatic vessel groups (anteromedial, anterolateral, posteromedial, and posterolateral) in the lower limb. Thus, three additional injection sites are needed for lymphatic imaging of the entire lower limb. We aimed to validate a multiple injection designed protocol and demonstrate its clinical benefits. Overall, 206 lower limbs undergoing indocyanine green fluorescent lymphography with the new injection protocol were registered retrospectively. To assess the influence of predictor variables on the degree of severity, multivariable logistic regression models were used with individual known risk factors. Using a generalized linear model, the area under the curve (AUC) of the conventional clinical model, comprising known severity risk factors, was compared with that of the modified model that included defects in the posterolateral and posteromedial groups. Multivariable logistic regression models showed a significant difference for the posteromedial and posterolateral groups. The AUC of the modified model was significantly improved compared to that of the conventional clinical model. Finding defects in the posteromedial and posterolateral groups is a significant criterion for judging lymphedema severity and introducing a new lymphedema severity classification.


Asunto(s)
Colorantes Fluorescentes/administración & dosificación , Verde de Indocianina/administración & dosificación , Extremidad Inferior/diagnóstico por imagen , Vasos Linfáticos/diagnóstico por imagen , Linfedema/diagnóstico por imagen , Linfografía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inyecciones Subcutáneas , Linfedema/clasificación , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
12.
J Vasc Surg Venous Lymphat Disord ; 10(3): 728-737.e3, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34592477

RESUMEN

OBJECTIVE: Indocyanine green (ICG) fluorescent lymphography might be useful for assessing patients undergoing lymphatic surgery for secondary lymphedema. The present clinical trial aimed to confirm whether ICG fluorescent lymphography would be useful in evaluating lymphedema, identifying lymphatic vessels suitable for anastomosis, and confirming patency of lymphaticovenular anastomosis in patients with secondary lymphedema. METHODS: The present phase III, multicenter, single-arm, open-label, clinical trial (HAMAMATSU-ICG study) investigated the accuracy of lymphedema diagnosis via ICG fluorescent lymphography compared with lymphoscintigraphy, rate of identification of lymphatic vessels at the incision site, and efficacy for confirming patency of lymphaticovenular anastomosis. The external diameter of the identified lymphatic vessels and the distance from the skin surface to the lymphatic vessels using preoperative ICG fluorescent lymphography were measured intraoperatively under surgical microscopy. RESULTS: When the clinical decision for surgery at each research site was made, the standard diagnosis of lymphedema was considered correct. For the 26 upper extremities, a central judgment committee who was unaware of the clinical presentation confirmed the imaging diagnosis was accurate for 100.0% of cases, whether the assessments had been performed via lymphoscintigraphy or ICG lymphography. In contrast, for the 88 lower extremities, the accuracy of the diagnosis compared with the diagnosis by the central judgment committee was 70.5% and 88.2% for lymphoscintigraphy and ICG lymphography, respectively. The external diameter of the identified lymphatic vessels was significantly greater in the lower extremities than in the upper extremities (0.54 ± 0.21 mm vs 0.42 ± 0.14 mm; P < .0001). Also, the distance from the skin surface to the lymphatic vessels was significantly longer in the lower extremities than in the upper extremities (5.8 ± 3.5 mm vs 4.4 ± 2.6 mm; P = .01). For 263 skin incisions, with the site placement determined using ICG fluorescent lymphography, the rate of identification of lymphatics vessels suitable for anastomosis was 97.7% (95% confidence interval, 95.1%-99.2%). A total of 267 lymphaticovenular anastomoses were performed. ICG fluorescent lymphography was judged as "useful" for confirming patency after the anastomosis in 95.1% of the cases. CONCLUSIONS: ICG fluorescent lymphography could be useful for improving the treatment of patients with secondary lymphedema from the outpatient setting to surgery.


Asunto(s)
Vasos Linfáticos , Linfedema , Colorantes , Humanos , Verde de Indocianina , Vasos Linfáticos/diagnóstico por imagen , Vasos Linfáticos/cirugía , Linfedema/diagnóstico por imagen , Linfedema/etiología , Linfedema/cirugía , Linfografía/métodos , Microcirugia/métodos
14.
Intern Med ; 59(16): 2067-2070, 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32389944

RESUMEN

Odontogenic infections, generally caused by dental caries and periodontal disease, can result in fatal illness. We herein report a 71-year-old Japanese woman with type 2 diabetes and hemodialysis who suffered from multiple dentofacial abscesses mainly caused by multidrug-resistant Streptococcus oralis. She complained of pain and swelling of her face, with an extraoral fistula from the left cheek. Following 3 surgical debridement procedures and partial mandibulectomy, in addition to 12 weeks of antimicrobial therapy, the multiple dentofacial abscesses were ameliorated. A combination of surgical and antimicrobial treatments following an early diagnosis is essential for reducing further complications.


Asunto(s)
Absceso/complicaciones , Absceso/microbiología , Diabetes Mellitus Tipo 2/complicaciones , Diálisis Renal , Infecciones Estreptocócicas/complicaciones , Anciano , Farmacorresistencia Bacteriana Múltiple , Femenino , Humanos , Infecciones Estreptocócicas/terapia , Streptococcus oralis
15.
Plast Reconstr Surg Glob Open ; 8(4): e2797, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32440453

RESUMEN

BACKGROUND: Multidirectional cranial distraction osteogenesis (MCDO) can achieve a desired shape for deformities of the cranium. In the past, visual estimation was used to reflect on the actual skull, but it was time-consuming and inaccurate. Here we demonstrate an effective osteotomy navigation method using surgical guides made from a dental impression silicone. METHODS: Seven patients who underwent MCDO between August 2013 and September 2016 were included in the study. Five cases involved utilization of the surgical guide for osteotomy. Three-dimensional (3D) printed cranium models were made using 3D computed tomography (3DCT) imaging data and dental impression silicone sheets were molded using the printed cranium models. These surgical guides were sterilized and used for intraoperative osteotomy design. Vertical distance between nasion/porion and osteotomy lines were calculated using 3D printed cranial models and postoperative 3DCT images to assess reproducibility. RESULTS: The average surgical time/design time was 535/37.0 minutes for the nonsurgical guide group and 486.8/11.8 minutes for the surgical guide group (SG).Treatment using the surgical guide was significantly shorter in terms of operative time and time required for design. For the vertical distance comparison, the average distance was 5.7mm (SD = 0.3) in the non-SG and 2.5mm (SD = 0.44) in the SG, and SG was more accurate. CONCLUSIONS: Shorter operative times and higher reproducibility rates could be achieved by using the proposed surgical guide, which is accurate, low-cost, and easily accessible.

16.
Artículo en Japonés | MEDLINE | ID: mdl-32307365

RESUMEN

In order to correct the lateral effect caused by the light source of the flatbed scanner in the Gafchromic film EBT3, the usefulness of the correction method using the average value of the correction coefficient considering the scan directions were evaluated. EBT3 was scanned from four directions to measure the optical density (OD) of the red, blue, and, red/blue components and the correction coefficient were calculated. For the correction coefficients, average values were calculated for the purpose of use, when the scan directions could not be aligned (average lateral effect correction). Correction accuracy was verified with the pass rate of gamma analysis (3 mm/3%, threshold 30%) of the dose distribution using the EBT3 film irradiated with the step pattern. OD of the red, blue, and, red/blue components in the scanning vertical direction tended to be higher in the center than in the peripheral portion. The pass rate of the step pattern was the red component's before correction, from 26.9 to 45.1% (before correction), from 84.1 to 96.7% (after correction), the red/blue component, from 37.6 to 48.4% (before correction) and from 84.4 to 96.7% (after correction). When using the correction coefficient using the average value, the pass rate was 89.8% for the red component and 94.7% for the red/blue component. The lateral effect correction improves the accuracy of the dose distribution verification, and the correction coefficient using the average value is useful when the scanning direction is different from that at the time of obtaining the dose concentration curve.


Asunto(s)
Algoritmos , Dosimetría por Película , Calibración , Cintigrafía
17.
Rep Pract Oncol Radiother ; 25(3): 376-381, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32322176

RESUMEN

PURPOSE: We investigated the feasibility of robust optimization for volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) for liver cancer in comparison with planning target volume (PTV)-based optimized plans. Treatment plan quality, robustness, complexity, and accuracy of dose delivery were assessed. METHODS: Ten liver cancer patients were selected for this study. PTV-based optimized plans with an 8-mm PTV margin and robust optimized plans with an 8-mm setup uncertainty were generated. Plan perturbed doses were evaluated using a setup error of 8 mm in all directions from the isocenter. The dosimetric comparison parameters were clinical target volume (CTV) doses (D98%, D50%, and D2%), liver doses, and monitor unit (MU). Plan complexity was evaluated using the modulation complexity score for VMAT (MCSv). RESULTS: There was no significant difference between the two optimizations with respect to CTV doses and MUs. Robust optimized plans had a higher liver dose than did PTV-based optimized plans. Plan perturbed dose evaluations showed that doses to the CTV for the robust optimized plans had small variations. Robust optimized plans were less complex than PTV-based optimized plans. Robust optimized plans had statistically significant fewer leaf position errors than did PTV-based optimized plans. CONCLUSIONS: Comparison of treatment plan quality, robustness, and plan complexity of both optimizations showed that robust optimization could be feasibile for VMAT of liver cancer.

18.
Med Phys ; 47(4): 1509-1522, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32026482

RESUMEN

PURPOSE: In photon radiation therapy, computed tomography (CT) numbers are converted into values for mass density (MD) or relative electron density to water (RED). CT-MD or CT-RED calibration tables are relevant for human body dose calculation in an inhomogeneous medium. CT-MD or CT-RED calibration tables are influenced by patient imaging (CT scanner manufacturer, scanning parameters, and patient size), the calibration process (tissue-equivalent phantom manufacturer, and selection of tissue-equivalent material), differences between tissue-equivalent materials and standard tissues, and the dose calculation algorithm applied; however, a CT number calibration audit has not been established. The purposes of this study were to develop a postal audit phantom, and to establish a CT number calibration audit process. METHODS: A conventional stoichiometric calibration conducts a least square fit of the relationships between the MD, material weight, and measured CT number, using two parameters. In this study, a new stoichiometric CT number calibration scheme has been empirically established, using three parameters to harmonize the calculated CT number with the measured CT number for air and lung tissue. In addition, the suitable material set and the minimal number of materials required for stoichiometric CT number calibration were determined. The MDs and elemental weights from the International Commission on Radiological Protection Publication 110 were used as standard tissue data, to generate the CT-MD and CT-RED calibration tables. A small-sized, CT number calibration phantom was developed for a postal audit, and stoichiometric CT number calibration with the phantom was compared to the CT number calibration tables registered in the radiotherapy treatment planning systems (RTPSs) associated with five radiotherapy institutions. RESULTS: When a least square fit was performed for the stoichiometric CT number calibration with the three parameters, the calculated CT number showed better agreement with the measured CT number. We established stoichiometric CT number calibration using only two materials because the accuracy of the process was determined not by the number of used materials but by the number of elements contained. The stoichiometric CT number calibration was comparable to the tissue-substitute calibration, with a dose difference less than 1%. An outline of the CT number calibration audit was demonstrated through a multi-institutional study. CONCLUSIONS: We established a new stoichiometric CT number calibration method for validating the CT number calibration tables registered in RTPSs. We also developed a CT number calibration phantom for a postal audit, which was verified by the performances of multiple CT scanners located at several institutions. The new stoichiometric CT number calibration has the advantages of being performed using only two materials, and decreasing the difference between the calculated and measured CT numbers for air and lung tissue. In the future, a postal CT number calibration audit might be achievable using a smaller phantom.


Asunto(s)
Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X/instrumentación , Calibración , Proyectos Piloto
19.
Radiology ; 294(1): 223-229, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31746690

RESUMEN

Background Most lymphatic imaging examinations of the lower limb require intradermal or subcutaneous injection of tracer material into the foot to demonstrate the lymphatic vessels; however, no standard protocol exists, and single or multiple injections are applied at different sites. Purpose To determine the three-dimensional relationships between each lymphatic group of the lower limb and corresponding regional lymph nodes. Materials and Methods A total of 130 lower limbs (55 from men and 75 from women) from 83 fresh human cadavers were studied. Lymphatic vessels were first visualized by using indocyanine green fluorescent lymphography with 19 injection sites in the foot, classified into four distinct lymphatic groups (anteromedial, anterolateral, posteromedial, and posterolateral); dilute oil-based contrast material was then injected. Next, specimens were scanned with CT and three-dimensional images were analyzed. Results The anteromedial and anterolateral lymphatic groups of the lower-leg lymphatic vessels were independent of each other and connected to different regional lymph nodes in the inguinal region. The posteromedial group and the anteromedial group in the lower leg drained to the same inguinal lymph nodes. Only the posterolateral group of lymphatic vessels in the lower leg drained to the popliteal lymph nodes. Leg lymphatic drainage pathways were independent of genital pathways. Conclusion Standard injection sites at the web spaces between the toes did not help visualize some lymph nodes of the lower leg. Additional injection sites in the medial, lateral, and posterior aspect of the foot would be better for evaluating the whole lymphatic pathways and regional lymph nodes and for improving understanding of leg lymphedema. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Weiss and Liddel in this issue.


Asunto(s)
Imagenología Tridimensional/métodos , Extremidad Inferior/diagnóstico por imagen , Ganglios Linfáticos/irrigación sanguínea , Ganglios Linfáticos/diagnóstico por imagen , Vasos Linfáticos/diagnóstico por imagen , Linfografía/métodos , Cadáver , Medios de Contraste , Femenino , Humanos , Verde de Indocianina , Masculino , Tomografía Computarizada por Rayos X
20.
Acta Med Okayama ; 73(5): 393-401, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31649365

RESUMEN

Although many surgical centers perform microsurgery routinely in developed countries, performing microsurgery is challenging in resource-poor developing countries, such as Myanmar. With the establishment of educational training programs and the assistance of volunteer plastic surgical teams, local plastic surgeons can learn the techniques of microsurgery and apply them clinically. The purpose of this study was to establish baseline data and define the challenges of performing microsurgery in Yangon General Hospital, Myanmar. Sixty-four patients underwent reconstruction with free flaps from January 2015 to January 2018. All clinical records of these cases were assessed. The number of free flap reconstructions performed increased from 11 in the first year to 24 in the third year. The anterolateral thigh flap was the most commonly used (42%). The most common sites of reconstruction were mandible and intraoral defects. Total flap survival occurred in 58 of 64 patients (89%). The total salvageable flap rate for revision surgery was 66.6%; the successful revision rate was highest in 2017, with fewer complications. The flap salvage rates increased and the operative duration decreased as clinical experience improved. Establishing a microsurgical center requires a strong multidisciplinary team, clinical experience, continuous learning, sensible clinical application, and effective interdepartmental and intradepartmental cooperation.


Asunto(s)
Microcirugia/métodos , Adolescente , Adulto , Anciano , Femenino , Colgajos Tisulares Libres , Humanos , Tiempo de Internación , Masculino , Microcirugia/efectos adversos , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA