Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39080073

RESUMEN

Benign central venous occlusions are frequently associated with long-term central venous access. Most of these occlusions can be recanalized with conventional endovascular technique. When conventional technique fails, sharp recanalization techniques (SRTs) can increase technical success. The SRTs include single low-profile needles, needle coaxial systems, re-entry catheter, the back end of stiff guidewires, and systems that can deliver radiofrequency energy or laser. This review on SRTs presents technical details and outcomes of the most common techniques used in central venous recanalization.

2.
Dermatol Clin ; 40(4): 367-377, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36243424

RESUMEN

Vascular tumors and malformations encompass a spectrum of pathology that varies widely in presentation, severity, and treatments. Although typically a clinical diagnosis, accurate classification of lesions is often challenging. Imaging plays an integral role in confirming the clinical diagnosis, determining the extent of disease and planning treatment strategies. Ultrasound and MRI constitute the backbone of diagnostic imaging in vascular anomalies; however, other modalities such as radiography, computed tomography, and conventional angiography can play a role in certain situations.


Asunto(s)
Malformaciones Vasculares , Humanos , Tomografía Computarizada por Rayos X , Ultrasonografía , Malformaciones Vasculares/diagnóstico
3.
JACC Case Rep ; 4(6): 359-363, 2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35495555

RESUMEN

We used aspiration thrombectomy to treat a 66-year-old man with renal cell carcinoma undergoing radical nephrectomy and caval thrombectomy with a massive pulmonary artery tumor embolism. (Level of Difficulty: Intermediate.).

6.
J Vasc Interv Radiol ; 32(4): 562-568, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33558125

RESUMEN

PURPOSE: To compare the utility of low-dose versus standard cone-beam computed tomography (CT) angiography protocols in identifying nontarget embolization (NTE) during prostatic artery embolization (PAE). MATERIALS AND METHODS: A prospective, single-center, Phase-1 study (NCT02592473) was conducted for lower urinary tract symptoms in benign prostatic hyperplasia. Prostate volume, international prostate symptom score (IPSS), quality of life score (QoL), International Index of Erectile Function (IIEF), peak flow rate, UCLA Prostate Cancer Index (UCLA-PCI), and postvoid residual were recorded at baseline and 1, 3, 6, 12, and 24-months after PAE. Six-second (standard protocol, n = 29) or 5-second (low-dose protocol n = 45) rotations were made. Images were selected and matched in pairs by areas of NTE and compared by readers using a binomial generalized estimating equation model. Procedural outcomes were analyzed using a linear mixed model. RESULTS: Seventy-four cone-beam CT angiographies were performed in 21 patients. IPSS and QoL scores significantly improved (P <.05). There was no change in UCLA-PCI or IIEF scores. Dose area product of the low- and standard-dose protocol were 37,340.82 mGy·cm2 ± 104.66 and 62,645.66 mGy·cm2 ± 12,711.48, respectively, representing a dose reduction of 40.4%. A total of 120 comparisons showed no preference between the 2 protocols (P =.24). Observers identified 76 and 69 instances of NTE in the standard- and low-dose protocols, respectively (P =.125). CONCLUSIONS: Low-dose cone-beam CT angiography achieved equivalent clinical utility in identifying NTE during PAE, with the advantage of a lower radiation dose.


Asunto(s)
Arterias/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Tomografía Computarizada de Haz Cónico , Embolización Terapéutica , Síntomas del Sistema Urinario Inferior/terapia , Próstata/irrigación sanguínea , Hiperplasia Prostática/terapia , Dosis de Radiación , Exposición a la Radiación/prevención & control , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/efectos adversos , Tomografía Computarizada de Haz Cónico/efectos adversos , Embolización Terapéutica/efectos adversos , Humanos , Síntomas del Sistema Urinario Inferior/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Hiperplasia Prostática/diagnóstico por imagen , Exposición a la Radiación/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
7.
PLoS One ; 16(1): e0245134, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33411747

RESUMEN

OBJECTIVES: To assess the feasibility of quantitative analysis of dynamic computed tomography angiography (dCTA) for the detection of endoleaks in patients who underwent endovascular repair of abdominal aortic aneurysms (EVAR). MATERIAL AND METHODS: Twenty patients scheduled for contrast-enhanced CT angiography (CTA) of the abdominal aorta post-EVAR were prospectively enrolled. All patients received a standard triphasic CTA protocol, followed by an additional dCTA. The dCTA acquisition enabled reconstruction of color-coded maps depicting blood perfusion and a dCTA dataset of the aneurysm sac. Observers assessed the dCTA and dynamic CT perfusion (dCTP) images for the detection of endoleaks, establishing diagnostic confidence based on a modified 5-point Likert scale. An index was calculated for the ratio between the endoleak and aneurysm sac using blood flow for dCTP and Hounsfield units (HU) for dCTA. The Wilcoxon test compared the endoleak index and the diagnostic confidence of the observers. RESULTS: In total, 19 patients (18 males, median age 74 years [70.5-75.7]) were included for analysis. Nine endoleaks were detected in 7 patients using triphasic CTA as the reference standard. There was complete agreement for endoleak detection between the two techniques on a per-patient basis. Both dCTA and dCTP identified an additional endoleak in one patient. The diagnostic confidence using dCTP for detection of endoleaks was not significantly superior to dCTA (5.0 [5-5] vs. 4.5 [4-5], respectively; p = 0.11); however, dCTP demonstrated superior diagnostic confidence for endoleak exclusion compared to dCTA (1.0 [1-1] vs 1.5 [1.5-1.5], respectively; p <0.01). Moreover, the dCTP endoleak index was significantly higher than the dCTA index (18.5 [10.8-20.5] vs. 3.5 [5-2.7], respectively; p = 0.02). CONCLUSIONS: Quantitative analysis of dCTP imaging can aid in the detection of endoleaks and demonstrates a higher endoleak detection rate than triphasic CTA, as well as a strong correlation with visual assessment of dCTA images.


Asunto(s)
Aorta Abdominal , Aneurisma de la Aorta Abdominal , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Anciano , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Femenino , Humanos , Masculino
8.
J Gastrointest Oncol ; 11(2): 298-303, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32399271

RESUMEN

BACKGROUND: Conventional transarterial chemoembolization (cTACE) has been the standard treatment for intermediate stage hepatocellular carcinoma (HCC). For early stage HCC, percutaneous ablation is a curative option. There is growing evidence to support combined therapy to improve tumor response and overall survival (OS) in patients with unresectable HCC. The goal of this study is to retrospectively review a single institution patient population who underwent the combined approach to determine its efficacy and safety, and possible predictive factors for OS and tumor response. METHODS: Retrospective analysis identified all patients that underwent c-TACE with Mitomycin followed by percutaneous ablation from 2011 to 2016 at our institution. Efficacy was assessed by OS, time to progression (TTP), and tumor response according to mRECIST criteria. Initial imaging was obtained 1 month after each treatment and after complete response was achieved, every 3 months for 2 years. Percentage of Lipiodol uptake was determined at 30-day follow-up with contrasted abdominal CT. Safety was assessed using Common Terminology Criteria for Adverse Events (CTCAE) v4.0. Multiple linear regressions were conducted to predict OS and number of progression-free survival days based on potential predictive factors. RESULTS: A total of 50 patients were identified. At 1-month follow-up, objective response (CR + PR) was achieved in 44 patients (88%). The median OS was 26.6 months and median TTP was 9.7 months (n=50). There was no statistically significant difference in median OS between patients with different lesion size (P=0.95), BCLC stage (P=0.84) or Lipiodol uptake (P=0.36). Higher albumin/bilirubin ratio was significantly correlated with improved OS (P=0.024). CONCLUSIONS: Combined c-TACE and PTA is a safe and effective approach for patients with unresectable HCC. Elevated albumin/bilirubin ratio was a predictor for improved OS.

9.
J Vasc Surg Cases Innov Tech ; 5(3): 356-359, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31440713

RESUMEN

The goal of this case report was to demonstrate the feasibility, safety, and efficacy of image fusion software to treat symptomatic central venous occlusion with radiofrequency wire after failure of conventional endovascular techniques. The complex and chronic central venous occlusion was successfully treated without complications. The combination of these techniques provided an endovascular solution and could be considered in select cases.

10.
J Gastrointest Oncol ; 10(2): 348-353, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31032104

RESUMEN

BACKGROUND: Conventional transarterial chemoembolization (c-TACE) is a common treatment for unresectable hepatocellular carcinoma (HCC). It is associated with increased overall survival (OS) when compared to conservative management. The purpose of this study is to analyze all c-TACE with mitomycin in patients with HCC at a single institution to determine safety, efficacy, and prognostic factors in a long-term follow-up. METHODS: Retrospective analysis of patients with HCC treated only with c-TACE with Mitomycin between 2007 and 2012. Efficacy was determined by OS at 1, 3, and 5 years, censored by date of death or last known follow-up. Treatment response was assessed according to mRECIST criteria and the degree of lipiodol uptake by the lesions was assessed by CT at 1-month follow-up. Prognostic factors were analyzed by multiple linear regression analysis, significance levels set at 0.05. RESULTS: A total of 60 patients were identified. OS rate at 1, 3 and 5 years was 72.1%, 47.8% and 39.3%, respectively. Median OS was 15 months. Tumor response by mRECIST criteria was complete; objective response, defined as combination of complete response (CR) and partial response (PR) patients, was 76%. When stratified by tumor response, risk of death in patients with progressive disease in 5 years was significantly higher compared to patients with objective response [hazard ratio (HR): 2.531, 95% confidence interval (CI): 1.110-5.778, P=0.0273]. Lipiodol uptake analysis was available in 51 patients; there was no statistically significant difference in OS in patients with higher lipiodol uptake compared to less uptake (<50% versus >50% uptake; HR: 0.713, 95% CI: 0.316-1.611, P=0.4161]. CONCLUSIONS: c-TACE with mitomycin was effective and safe in this long-term follow-up study. Risk of death was significantly higher in patients without objective tumor response.

11.
J Vasc Interv Radiol ; 30(3): 390-395, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30819481

RESUMEN

PURPOSE: To assess the safety and efficacy of single-session transarterial embolization and radiofrequency (RF) ablation for hepatic tumors with the use of needle navigation software. MATERIALS AND METHODS: Retrospective analysis was conducted of 24 patients with liver cancer undergoing embolization followed by RF ablation between May 2014 and August 2017. Twelve patients each underwent (i) embolization and computed tomography (CT)-guided RF ablation during different sessions (group 1) and (ii) embolization followed by RF ablation with cone-beam CT and Needle Assist software in 1 session (group 2). Median age (70.5 y [range, 58-78 y] vs 70.5 y [range, 50-82 y]; P = .76) and performance status (0/1) were comparable between groups. Median tumor size was significantly larger in group 2 (2 cm [range, 1.0-7.3 cm] vs 3.2 cm [range, 1.1-9.6 cm]; P < .03). Procedure time, effective dose, and number of scans were examined. Efficacy was assessed by modified Response Evaluation Criteria In Solid Tumors after 1 month. Safety was assessed by Society of Interventional Radiology adverse event classification. RESULTS: Group 1 had a mean of 8.5 CT scans, vs a mean of 5.0 cone-beam CT scans in group 2 (P < .001). Median procedure times were 110 min in group 1 and 199.5 min in group 2 (P < .001). Median effective doses were 68.8 mSv in group 1 and 55.4 mSv in group 2 (P = .38). There was no difference in complete response between groups (66.7% vs 63.6%; P = 1). CONCLUSIONS: Transarterial embolization followed by RF ablation with cone-beam CT and needle guidance software in a single session seems to be safe and effective.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Embolización Terapéutica/métodos , Neoplasias Hepáticas/terapia , Ablación por Radiofrecuencia/métodos , Radiografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Tomografía Computarizada de Haz Cónico/efectos adversos , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/instrumentación , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Agujas , Dosis de Radiación , Exposición a la Radiación , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/instrumentación , Radiografía Intervencional/efectos adversos , Criterios de Evaluación de Respuesta en Tumores Sólidos , Estudios Retrospectivos , Programas Informáticos , Factores de Tiempo , Resultado del Tratamiento , Carga Tumoral
12.
Eur Radiol ; 29(9): 4783-4793, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30805703

RESUMEN

OBJECTIVES: To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard. METHODS: Eighty-eight patients (53 males; mean age, 65.9 ± 11 years) with suspected peripheral arterial disease (PAD) who had undergone a DE-CTA examination of the lower extremity runoff between May 2014 and May 2015 were included in this IRB-approved, HIPAA-compliant retrospective study. Standard linearly blended and CS images were reconstructed and vascular contrast-to-noise ratios (CNR) were calculated. Two independent observers assessed subjective image quality using a 5-point Likert scale. Diagnostic accuracy for ≥ 50% stenosis detection was analyzed in a subgroup of 45 patients who had undergone additional DSA. Diagnostic accuracy parameters were estimated with a random-effects logistic regression analysis and compared using generalized estimating equations. RESULTS: CS datasets showed higher CNR (15.3 ± 7.3) compared to standard reconstructions (13.5 ± 6.5, p < 0.001). Both reconstructions showed comparable qualitative image quality scores (CS, 4.64; standard, 4.57; p = 0.220). Diagnostic accuracy (sensitivity, specificity, positive and negative predictive values) for CS reconstructions was 96.5% (97.5%, 95.6%, 90.9%, 98.1) and 93.1% (98.8%, 90.4%, 82.3%, 99.1%) for standard images. CONCLUSIONS: A modified three-material decomposition CS algorithm provides increased vascular CNR, equivalent qualitative image quality, and greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff on DE-CTA compared with standard image reconstruction. KEY POINTS: • Calcified plaques may lead to overestimation of stenosis severity and false positive results, requiring additional invasive digital subtraction angiography (DSA). • A modified three-material decomposition algorithm for calcium subtraction provides greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff compared with standard image reconstruction. • The application of this algorithm in patients with heavily calcified vessels may be helpful to potentially reduce inconclusive CT angiography examinations and the need for subsequent invasive DSA.


Asunto(s)
Angiografía de Substracción Digital/métodos , Arteriopatías Oclusivas/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Extremidad Inferior/irrigación sanguínea , Anciano , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Calcificación Vascular/diagnóstico por imagen
13.
J Clin Med Res ; 10(10): 758-764, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30214647

RESUMEN

BACKGROUND: There is a wide variability in practice patterns on the use of inferior vena cava filters (IVCFs) among institutions, which is likely due to contrasting indication guidelines published by different professional societies. The aim of the present study is to report our healthcare system use of IVCF to: 1) determine practice patterns, 2) determine factors that may predict IVCF retrieval and 3) identify areas for improvement. METHODS: A retrospective review of 180 consecutive IVCF placement performed between July 2014 and December 2015 was conducted. RESULTS: One hundred nine (60.6%) IVCFs were placed for absolute indications, 27 (15.0%) for relative indications, 26 (14.4%) prophylactically and 18 (10.0%) for unknown indications. Average age was 59.3 years. Ninety-five had active cancer. Surgical and medical services requested filter placement in 112 (62.2%) and 68 (37.8%) patients, respectively. Thirteen (7.2%) patients had a hematology consult prior to IVCF placement. Documentation of the presence of an IVCF was present in 118/127 (92.9%) discharge summaries, and outlined instructions for filter retrieval post-discharge were present in 20/124 (16.1%) cases. Only 33 (25.0%) IVCF were retrieved at a median interval of 162 days (range: 4 - 1,053 days). None of the factors of interest was found to be significantly associated with IVCF retrieval. CONCLUSION: A root cause analysis identified that the lack of a structured system for IVCF tracking resulted in poor IVCF retrieval rates. This study resulted in the development of a hospital-initiated multidisciplinary team to address these issues.

15.
J Vasc Interv Radiol ; 29(1): 38-43, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29150395

RESUMEN

PURPOSE: To determine whether transradial access (TRA) or transfemoral access (TFA) provides better patient satisfaction during intra-arterial therapy (IAT) for liver cancer. MATERIALS AND METHODS: This randomized, prospective, intra- and interpatient controlled trial compared TRA vs TFA accesses in patients with primary or metastatic liver cancer undergoing IAT. After having one of each type of access (1 TRA and 1 TFA), all patients selected their preferred access regardless of whether a third intervention was indicated. The primary endpoint was patient access preference; secondary endpoints were access-related complications, procedure time, contrast agent volume, and radiation doses to the patient and operator. Patients were evaluated on postprocedure days 1 and 30. RESULTS: Fifty-five patients with liver cancer (31 hepatocellular carcinoma, 24 metastatic disease) were enrolled, and 124 IAT procedures were performed. A total of 36 patients underwent at least 1 intervention each with TRA and TFA. Of those, 29 patients (81%) preferred TRA and 7 (19%) preferred TFA (ratio, 4:1; P < .001). Median radiation exposure to the operator was significantly lower for TRA (5.5 mrem) vs TFA (13 mrem; P = .01). Incidences of complications, procedure time, contrast agent volume, and radiation exposure to patients were similar between groups. CONCLUSIONS: TRA was the preferred access for the majority of patients and was associated with less radiation exposure to the operator. No differences were detected in incidence of adverse events, procedure time, contrast agent volume, or patient radiation exposure.


Asunto(s)
Carcinoma Hepatocelular/terapia , Embolización Terapéutica/métodos , Arteria Femoral , Neoplasias Hepáticas/terapia , Satisfacción del Paciente , Arteria Radial , Anciano , Angiografía , Carcinoma Hepatocelular/patología , Medios de Contraste , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Resultado del Tratamiento , Ultrasonografía Intervencional
16.
JACC Cardiovasc Imaging ; 10(10 Pt A): 1116-1124, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28109932

RESUMEN

OBJECTIVES: This study sought to evaluate the image quality and diagnostic accuracy of noncontrast quiescent-interval single-shot (QISS) magnetic resonance angiography (MRA) versus iodine-contrast computed tomography angiography (CTA) in patients with peripheral artery disease (PAD), with invasive digital subtraction angiography (DSA) as the reference standard. BACKGROUND: QISS is a recently introduced noncontrast MRA technique. Although the diagnostic accuracy of QISS is reportedly similar to that of contrast-enhanced MRA, its performance compared with contrast-enhanced CTA, the most frequently used noninvasive modality for evaluation of PAD, is unknown. METHODS: Thirty patients (66 ± 7 years of age) with PAD underwent lower extremity CTA with third-generation dual-source dual-energy CT and 1.5-T MRA using a prototype noncontrast QISS sequence. DSA was performed within 50 days. The abdominal aorta and lower extremity run-off were imaged. Eighteen arterial segments were analyzed. Subjective image quality (3-point Likert scale) and stenosis (5-point grading) were evaluated by 2 observers and compared using the Mann-Whitney U and chi-square tests, respectively. Sensitivity and specificity of MRA and CTA for >50% stenosis detection were compared using the McNemar-test. RESULTS: Of 540 segments, 15 (2.8%) and 42 (7.8%) inconclusive segments were excluded from MRA and CTA analysis, respectively (p = 0.0006). The DSA results were available for 410 of the remaining segments. Overall subjective image quality was rated similarly with QISS-MRA (2.52 [95% confidence interval: 2.46 to 2.57]) and CTA (2.49 [95% confidence interval: 2.43 to 2.55]; p = 0.5062). The sensitivity and specificity of MRA for >50% stenosis were 84.9% and 97.2%, respectively, similar to those of CTA (87.3% and 95.4%, respectively). Interobserver agreement for stenosis detection was excellent for MRA (κ > 0.81) and CTA (κ > 0.81). CONCLUSIONS: Noncontrast QISS-MRA provides high diagnostic accuracy compared with DSA, while being less prone to image artifacts than CTA. QISS better visualizes heavily calcified segments with impaired flow. QISS-MRA obviates the need for contrast administration in PAD patients.


Asunto(s)
Angiografía de Substracción Digital , Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada , Extremidad Inferior/irrigación sanguínea , Angiografía por Resonancia Magnética , Enfermedad Arterial Periférica/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Aorta Abdominal/fisiopatología , Velocidad del Flujo Sanguíneo , Distribución de Chi-Cuadrado , Constricción Patológica , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Calcificación Vascular/fisiopatología
17.
J Gastrointest Oncol ; 8(6): 1072-1078, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29299369

RESUMEN

BACKGROUND: Hepatic malignancies are common including primary malignancies and metastases. Transarterial radioembolization (TARE) is an important treatment option. We reviewed safety and efficacy of (TARE) in our patients to identify factors that may impact treatment outcomes in a heterogeneous population. METHODS: All patients that received TARE at the Medical University of South Carolina from March 2006 through May of 2014 were included. Kaplan-Meier estimates on overall survival (OS) from date of first procedure are reported. Potential prognostic factors for OS were evaluated using log rank tests and Cox proportional hazards models. RESULTS: In the 114 patients that received TARE at our institution, median follow-up was 6.4 months (range, 0-86 months) with the following histologies: colorectal (CR) n=55, hepatocellular (HC) n=20, cholangiocarcinoma (CC) n=16, neuroendocrine (NE) n=12, breast (BR) n=6, other n=5. At least 1 line of prior systemic therapy was noted in 79% of patients. Median OS was significantly better with NE and BR histology, and in those with normal albumin levels. With an albumin >3.4 median OS was 10.3 months, but was only 3.1 months with an albumin <3 g/dL. Grade ≥2 toxicity was observed in 22 patients (19.3%) including 9 (7.9%) with Grade 3 and 1 (0.9%) with Grade 4 toxicity. CONCLUSIONS: TARE is a relatively safe and effective treatment for intrahepatic malignancies. Patients with NE and BR histology as well as those with better hepatic synthetic function were associated with significantly better survival. Our data suggest that patients with albumin below 3 g/dL may not derive significant benefit from TARE.

18.
Orthopedics ; 39(5): e1024-7, 2016 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-27398782

RESUMEN

Avulsion fractures of the posterior cruciate ligament (PCL) are usually found in pediatric populations. This study investigated which of 2 approaches-posteromedial or direct posterior-enables easier PCL reinsertion. Ten fresh cadavers were studied using direct posterior (10 knees) and posteromedial (10 knees) approaches. In both, a guidewire was inserted into the tibial insertion of the PCL as perpendicular as possible to the coronal knee axis. Then, the angle between the guidewire and the horizontal plane of the table was measured. The mean angle of the guidewire was 8.6° (SD=7.3°) with the direct posterior approach and 36.6° (SD=14.3°) with the posteromedial approach (P=.005). The direct posterior approach allows a greater degree of freedom compared with the posteromedial approach to reach the PCL tibial insertion. [Orthopedics. 2016; 39(5):e1024-e1027.].


Asunto(s)
Articulación de la Rodilla/cirugía , Procedimientos Ortopédicos/métodos , Ligamento Cruzado Posterior/cirugía , Tibia/cirugía , Femenino , Humanos , Masculino , Ligamento Cruzado Posterior/lesiones
19.
Eur Radiol ; 26(12): 4380-4389, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26960541

RESUMEN

PURPOSE: To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). MATERIAL AND METHODS: We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F_0.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F_0.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. RESULTS: At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F_0.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F_0.5 (90.9, 94.1, 89.3 %). CONCLUSION: 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. KEY POINTS: • The impact of noise-optimized virtual monochromatic imaging on stent visualization was assessed. • Virtual monochromatic imaging significantly improves stent lumen visualization and diagnostic confidence. • At 80 keV diagnostic performance for detection of in-stent restenosis was increased. • 80 keV virtual monochromatic images are recommended for stent evaluation of lower extremity vasculature.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada/métodos , Oclusión de Injerto Vascular/diagnóstico por imagen , Stents , Adulto , Anciano , Femenino , Humanos , Isquemia/diagnóstico por imagen , Isquemia/terapia , Extremidad Inferior/irrigación sanguínea , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido
20.
Invest Radiol ; 51(2): 139-46, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26561048

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the impact of a noise-optimized virtual monochromatic imaging algorithm (VMI+) on image quality and diagnostic accuracy at dual-energy computed tomography angiography (CTA) of the lower extremity runoff. MATERIALS AND METHODS: This retrospective Health Insurance Portability and Accountability Act-compliant study was approved by the local institutional review board. We evaluated dual-energy CTA studies of the lower extremity runoff in 48 patients (16 women; mean age, 63.3 ± 13.8 years) performed on a third-generation dual-source CT system. Images were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monochromatic (VMI) algorithms at 40 to 120 keV in 10-keV intervals. Vascular attenuation and image noise in 18 artery segments were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used to subjectively evaluate vascular attenuation and image noise. In a subgroup of 21 patients who underwent additional invasive catheter angiography, diagnostic accuracy for the detection of significant stenosis (≥50% lumen restriction) of F_0.5, 50-keV VMI+, and 60-keV VMI data sets were assessed. RESULTS: Objective image quality metrics were highest in the 40- and 50-keV VMI+ series (SNR: 20.2 ± 10.7 and 19.0 ± 9.5, respectively; CNR: 18.5 ± 10.3 and 16.8 ± 9.1, respectively) and were significantly (all P < 0.001) higher than in the corresponding VMI data sets (SNR: 8.7 ± 4.1 and 10.8 ± 5.0; CNR: 8.0 ± 4.0 and 9.6 ± 4.9) and F_0.5 series (SNR: 10.7 ± 4.4; CNR: 8.3 ± 4.1). Subjective assessment of attenuation was highest in the 40- and 50-keV VMI and VMI+ image series (range, 4.84-4.91), superior to F_0.5 (4.07; P < 0.001). Corresponding subjective noise assessment was superior for 50-keV VMI+ (4.71; all P < 0.001) compared with VMI (2.60) and F_0.5 (4.11). Sensitivity and specificity for detection of 50% or greater stenoses were highest in VMI+ reconstructions (92% and 95%, respectively), significantly higher compared with standard F_0.5 (87% and 90%; both P ≤ 0.02). CONCLUSIONS: Image reconstruction using low-kiloelectron volt VMI+ improves image quality and diagnostic accuracy compared with traditional VMI technique and standard linear blending for evaluation of the lower extremity runoff using dual-energy CTA.


Asunto(s)
Angiografía de Substracción Digital/métodos , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA