Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 27
1.
Geriatr Nurs ; 58: 119-126, 2024 May 25.
Article En | MEDLINE | ID: mdl-38797022

BACKGROUND: The prevalence of mild cognitive impairment (MCI) is steadily increasing among elderly people with type 2 diabetes (T2DM). This study aimed to create and validate a predictive model based on a nomogram. METHODS: This cross-sectional study collected sociodemographic characteristics, T2DM-related factors, depression, and levels of social support from 530 older adults with T2DM. We used LASSO regression and multifactorial logistic regression to determine the predictors of the model. The performance of the nomogram was evaluated using calibration curves, receiver operating characteristics (ROC), and decision curve analysis (DCA). RESULTS: The nomogram comprised age, smoking, physical activity, social support, depression, living alone, and glycosylated hemoglobin. The AUC for the training and validation sets were 0.914 and 0.859. The DCA showed good clinical applicability. CONCLUSIONS: This predictive nomogram has satisfactory accuracy and discrimination. Therefore, the nomogram can be intuitively and easily used to detect MCI in elderly adults with T2DM.

2.
Angle Orthod ; 94(2): 200-206, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38052230

OBJECTIVES: To develop a photochromic bracket adhesive (PCA) with modification using photochromic material and evaluate the biocompatibility, bond strength, photochromic property, and adhesive removal efficiency. MATERIALS AND METHODS: The resin-modified glass ionomer powder was mixed with the photochromic material and then blended with the liquid agent to form PCA. Biocompatibility was evaluated by CCK-8 kit, and shear bond strength (SBS) was measured. Stereoscopic microscopy and quantitative color analysis were used to assess the photochromic property. Bracket bonding and debonding procedures were performed on a head simulator with the assistance of an ultraviolet radiator. The effectiveness of adhesive removal during bonding and debonding procedures was assessed using a stereomicroscope. Removal time was recorded, and the enamel damage index after debonding was analyzed. RESULTS: CCK-8 assay and SBS test indicated that 5wt.% mixing ratios of the photochromic material did not compromise the biocompatibility and SBS of the adhesive (PCA5). PCA5 showed photochromic properties and could help the operator remove adhesive more thoroughly without increasing enamel damage. CONCLUSIONS: Photochromic adhesive (PCA5) can be good for orthodontic adhesive removal and therefore has good clinical translation potential.


Dental Bonding , Orthodontic Brackets , Dental Cements , Resin Cements/chemistry , Sincalide , Surface Properties , Dental Bonding/methods , Materials Testing , Shear Strength , Dental Stress Analysis
3.
J Asthma ; 61(4): 300-306, 2024 Apr.
Article En | MEDLINE | ID: mdl-37830743

BACKGROUND: Patients' medication adherence plays a critical role in the treatment and rehabilitation of disease. However, few tools are currently available that can be used to identify the reasons for their nonadherence with their medication regimens. It is possible to evaluate both the level of medication adherence of a patient as well as the reasons for it using the Adherence to Asthma Medication Questionnaire (AAMQ). The purpose of this study was to adapt the AAMQ for use in Chinese patients and a variety of asthma patients. METHODS: A total of 242 asthma patients were recruited from Jinzhou in China. The Adherence to Asthma Medication Questionnaire was translated and back-translated using the Brislin translation model. Test-retest reliability, internal consistency, and stability all play a large role in determining the reliability of a scale. Confirmatory factor analysis was used to examine the scale's construct validity, and expert consultation was used to verify the scale's content validity. Statistics were deemed significant at p < 0.05. RESULTS: The Cronbach's α value of the Chinese version of the AAMQ was 0.866, and the coefficient values for the three domains ranged between 0.702 and 0.798. The split-half reliability and stability values were 0.794 and 0.772, respectively. The content validity index of the scale (S-CVI) was 0.923, and the content validity index of the level of scale entry was 0.857-1.000. According to the confirmatory factor analysis, the chi-square degreed of freedom were 1.484, and the model fitting indices were all within normal limits. CONCLUSIONS: The AAMQ had good reliability and validity for asthmatic patients. The results of the scale's assessment can be used as a criterion for medication adherence among asthmatic patients and to understand the causes. This study provides a reference for solving the problem of medication adherence among asthma patients and implementing targeted nursing measures. PATIENT OR PUBLIC CONTRIBUTION: Gratitude is extended to all individuals collaborating in completing the survey and to the author.


Asthma , Humans , Asthma/drug therapy , Psychometrics/methods , Reproducibility of Results , Surveys and Questionnaires , China , Medication Adherence
4.
Hortic Res ; 10(12): uhad219, 2023 Dec.
Article En | MEDLINE | ID: mdl-38077493

Increasing photosynthesis and light capture offers possibilities for improving crop yield and provides a sustainable way to meet the increasing global demand for food. However, the poor light transmittance of transparent plastic films and shade avoidance at high planting density seriously reduce photosynthesis and alter fruit quality in vegetable crops, and therefore it is important to investigate the mechanisms of light signaling regulation of photosynthesis and metabolism in tomato (Solanum lycopersicum). Here, a combination of red, blue, and white (R1W1B0.5) light promoted the accumulation of chlorophyll, carotenoid, and anthocyanin, and enhanced photosynthesis and electron transport rates by increasing the density of active reaction centers and the expression of the genes LIGHT-HARVESTING COMPLEX B (SlLHCB) and A (SlLHCA), resulting in increased plant biomass. In addition, R1W1B0.5 light induced carotenoid accumulation and fruit ripening by decreasing the expression of LYCOPENE ß-CYCLASE (SlCYCB). Disruption of SlCYCB largely induced fruit lycopene accumulation, and reduced chlorophyll content and photosynthesis in leaves under red, blue, and white light. Molecular studies showed that ELONGATED HYPOCOTYL 5 (SlHY5) directly activated SlCYCB, SlLHCB, and SlLHCA expression to enhance chlorophyll accumulation and photosynthesis. Furthermore, R1W1B0.5 light-induced chlorophyll accumulation, photosynthesis, and SlHY5 expression were largely decreased in the slphyb1cry1 mutant. Collectively, R1W1B0.5 light noticeably promoted photosynthesis, biomass, and fruit quality through the photoreceptor (SlPHYB1 and SlCRY1)-SlHY5-SlLHCA/B/SlCYCB module in tomato. Thus, the manipulation of light environments in protected agriculture is a crucial tool to regulate the two vital agronomic traits related to crop production efficiency and fruit nutritional quality in tomato.

5.
Phys Rev Lett ; 131(15): 150601, 2023 Oct 13.
Article En | MEDLINE | ID: mdl-37897783

We report new Gaussian boson sampling experiments with pseudo-photon-number-resolving detection, which register up to 255 photon-click events. We consider partial photon distinguishability and develop a more complete model for the characterization of the noisy Gaussian boson sampling. In the quantum computational advantage regime, we use Bayesian tests and correlation function analysis to validate the samples against all current classical spoofing mockups. Estimating with the best classical algorithms to date, generating a single ideal sample from the same distribution on the supercomputer Frontier would take ∼600 yr using exact methods, whereas our quantum computer, Jiǔzhang 3.0, takes only 1.27 µs to produce a sample. Generating the hardest sample from the experiment using an exact algorithm would take Frontier∼3.1×10^{10} yr.

6.
Am J Orthod Dentofacial Orthop ; 164(4): e97-e105, 2023 Oct.
Article En | MEDLINE | ID: mdl-37565946

INTRODUCTION: Artificial intelligence (AI) developed rapidly in orthodontics, and AI-based cephalometric applications have been adopted. This study aimed to assess AI-assisted cephalometric technologies related knowledge, experience, and attitude among orthodontists and orthodontic students; describe their subject view of the applications and related technologies in orthodontics; and identify associated factors. METHODS: An online cross-sectional survey based on a professional tool (www.wjx.cn) was performed from October 11-17, 2022. Participants were recruited with a purposive and snowball sampling approach. Data was collected and analyzed with descriptive statistics, chi-square tests, and multivariable generalized estimating equations. RESULTS: Four hundred eighty valid questionnaires were collected and analyzed; 68.8% of the respondents agreed that AI-based cephalometric applications would replace manual and semiautomatic approaches. Practitioners using AI-assisted applications (87.5%) spent less time in cephalometric analysis than the other groups using other approaches, and 349 (72.7%) respondents considered AI-based applications could assist in obtaining more accurate analysis results. Lectures and training programs (56.0%) were the main sources of respondents' knowledge about AI. Knowledge level was associated with experience in AI-related clinical or scientific projects (P <0.001). Most respondents (88.8%) were interested in future AI applications in orthodontics. CONCLUSIONS: Respondents are optimistic about the future of AI in orthodontics. AI-assisted cephalometric applications were believed to make clinical diagnostic analysis more convenient and straightforward for practitioners and even replace manual and semiautomatic approaches. The education and promotion of AI should be strengthened to elevate orthodontists' understanding.


Artificial Intelligence , Orthodontists , Humans , Cross-Sectional Studies , Students , Surveys and Questionnaires , Health Knowledge, Attitudes, Practice
7.
Clin Oral Investig ; 27(10): 6027-6042, 2023 Oct.
Article En | MEDLINE | ID: mdl-37620439

OBJECTIVE: To investigate the antibacterial and enamel remineralization performances as well as physicochemical properties and biocompatibility of a fluoride-coated clear aligner plastic (FCAP). MATERIALS AND METHODS: FCAP and normal clear aligner plastic (CAP) was bought from the manufacturer (Angelalign Technology Inc, China). The FCAP was observed under scanning electron microscopy. Its element composition, resistance to separation, contact angle, and protein adhesion performance were characterized. Colony-forming unit (CFU) count and 3-(4,5)-dimethylthiazol(-z-y1)-3,5-diphenyltetrazolium bromide (MTT) assay were used to evaluate the antibacterial ability of Streptococcus mutans. Fluoride release-recharge patterns were obtained. Apatite formation was evaluated after immersing FCAP in artificial saliva. Enamel remineralization capability was evaluated in the demineralization model (immersing samples in demineralization solution for 36 h) and pH cycling model (immersing samples in demineralization solution and remineralization solution in turns for 14 days). Cell Counting Kit-8 (CCK-8) and live/dead cell staining kits were used for cytotoxicity assay. RESULTS: The FCAP showed uniformly distributed fluoride and did not compromise protein adhesion performance. CFU count (5.47 ± 0.55 for CAP, 3.63 ± 0.38 for FCAP) and MTT assay (0.41 ± 0.025 for CAP, 0.28 ± 0.038) indicated that the FCAP had stronger antibacterial activity compared with normal CAP (P < 0.05 for both evaluations). The FCAP could release fluoride continuously for 14 days and could be recharged after immersing in NaF solution. The FCAP could induce the formation of hydroxyapatite in artificial saliva and could reduce the microhardness decrease, color change, and mineral loss of enamels in both two models (P < 0.05 for all evaluations). CCK-8 and live/dead cell staining analyses showed that the coating did not compromise the biocompatibility of the clear aligner (P > 0.05 for CCK-8 evaluation). CONCLUSIONS: The FCAP had antibacterial, fluoride recharge, and enamel remineralization abilities while it did not compromise physicochemical properties and biocompatibility. CLINICAL RELEVANCE: The FCAP has the potential to prevent enamel demineralization during clear aligner treatment.


Dental Caries , Orthodontic Appliances, Removable , Tooth Demineralization , Humans , Fluorides/pharmacology , Tooth Demineralization/prevention & control , Saliva, Artificial , Tooth Remineralization , Hydrogen-Ion Concentration , Dental Enamel , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Dental Caries/prevention & control , Sodium Fluoride/pharmacology , Cariostatic Agents/therapeutic use
8.
Phys Rev Lett ; 130(19): 190601, 2023 May 12.
Article En | MEDLINE | ID: mdl-37243651

Gaussian boson sampling (GBS) is not only a feasible protocol for demonstrating quantum computational advantage, but also mathematically associated with certain graph-related and quantum chemistry problems. In particular, it is proposed that the generated samples from the GBS could be harnessed to enhance the classical stochastic algorithms in searching some graph features. Here, we use Jiǔzhang, a noisy intermediate-scale quantum computer, to solve graph problems. The samples are generated from a 144-mode fully connected photonic processor, with photon click up to 80 in the quantum computational advantage regime. We investigate the open question of whether the GBS enhancement over the classical stochastic algorithms persists-and how it scales-with an increasing system size on noisy quantum devices in the computationally interesting regime. We experimentally observe the presence of GBS enhancement with a large photon-click number and a robustness of the enhancement under certain noise. Our work is a step toward testing real-world problems using the existing noisy intermediate-scale quantum computers and hopes to stimulate the development of more efficient classical and quantum-inspired algorithms.

9.
J Mech Behav Biomed Mater ; 141: 105817, 2023 05.
Article En | MEDLINE | ID: mdl-37015147

OBJECTIVES: To develop an antibacterial and fluorescent clear aligner attachment resin via the incorporation of chlorhexidine loaded pore-expanded mesoporous silica nanoparticles (CHX@pMSN) and amino-silane functionalized zinc oxide quantum dots (aZnOQDs), and to evaluate its antibacterial activity, fluorescence capability, esthetic properties, mechanical performance and biocompatibility. METHODS: CHX@pMSN and aZnOQDs were incorporated into the commercial resin composites (Filtek Z350 XT, 3M) at different mass fractions, control group: Filtek; fluorescent attachment resin (FAR): Filtek + 3 wt% aZnOQDs; antibacterial and fluorescent attachment resin (AFAR)-1: Filtek + 3 wt% aZnOQDs + 1 wt% CHX@pMSN; AFAR-2: Filtek + 3 wt% aZnOQDs + 3 wt% CHX@pMSN; AFAR-3: Filtek + 3 wt% aZnOQDs + 5 wt% CHX@pMSN. CHX release, antibacterial activity, fluorescence capability, color change, stain resistance, degree of conversion, depth of cure, polymerization shrinkage, water sorption and solubility, softening in solvent, flexural strength, flexural modulus, shear bond strength, and cytotoxicity were evaluated comprehensively. RESULTS: CHX could be continuously released from the AFAR groups for up to 30 days. CFU, MTT, lactic acid production, SEM and CLSM evaluation showed AFAR-2 and AFAR-3 could effectively inhibit S. mutans biofilms even after 1-month aging. Only AFAR-3 showed clinically perceptible color change and all the experimental groups were not more susceptible to staining. AFAR-1 and AFAR-2 could suppress polymerization shrinkage and enhance the resistance to degradation without compromising other properties, including degree of conversion, water sorption and solubility, flexural strength, flexural modulus, and shear bond strength. Depth of cure of all the four experimental groups was significantly decreased (p < 0.05) but still within the ISO standard. CCK-8 assay and live/dead cell staining denied the cytotoxicity of experimental resins. Fluorescence intensity tests showed that FAR and AFAR-2 could emit strong yellowish fluorescence under the excitation of ultraviolet for up to six months. CONCLUSIONS: AFRA-2 possessed long-term antibiofilm activity, strong fluorescence capability and satisfying biocompatibility without compromising esthetic and mechanical properties. This study proposed a new strategy for reducing bacteria accumulation around the attachment, which is also promising in helping orthodontists to remove the attachment thoroughly and precisely.


Nanoparticles , Orthodontic Appliances, Removable , Quantum Dots , Zinc Oxide , Chlorhexidine/pharmacology , Chlorhexidine/chemistry , Silicon Dioxide/chemistry , Materials Testing , Composite Resins/chemistry , Nanoparticles/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Water , Methacrylates/chemistry
10.
Plant Physiol ; 192(1): 648-665, 2023 05 02.
Article En | MEDLINE | ID: mdl-36760172

Cold stress is a key environmental constraint that dramatically affects the growth, productivity, and quality of tomato (Solanum lycopersicum); however, the underlying molecular mechanisms of cold tolerance remain poorly understood. In this study, we identified REDUCED CHLOROPLAST COVERAGE 2 (SlREC2) encoding a tetratricopeptide repeat protein that positively regulates tomato cold tolerance. Disruption of SlREC2 largely reduced abscisic acid (ABA) levels, photoprotection, and the expression of C-REPEAT BINDING FACTOR (CBF)-pathway genes in tomato plants under cold stress. ABA deficiency in the notabilis (not) mutant, which carries a mutation in 9-CIS-EPOXYCAROTENOID DIOXYGENASE 1 (SlNCED1), strongly inhibited the cold tolerance of SlREC2-silenced plants and empty vector control plants and resulted in a similar phenotype. In addition, foliar application of ABA rescued the cold tolerance of SlREC2-silenced plants, which confirms that SlNCED1-mediated ABA accumulation is required for SlREC2-regulated cold tolerance. Strikingly, SlREC2 physically interacted with ß-RING CAROTENE HYDROXYLASE 1b (SlBCH1b), a key regulatory enzyme in the xanthophyll cycle. Disruption of SlBCH1b severely impaired photoprotection, ABA accumulation, and CBF-pathway gene expression in tomato plants under cold stress. Taken together, this study reveals that SlREC2 interacts with SlBCH1b to enhance cold tolerance in tomato via integration of SlNCED1-mediated ABA accumulation, photoprotection, and the CBF-pathway, thus providing further genetic knowledge for breeding cold-resistant tomato varieties.


Solanum lycopersicum , Solanum lycopersicum/genetics , Tetratricopeptide Repeat , Plant Breeding , Abscisic Acid/metabolism , Plant Proteins/genetics , Plant Proteins/metabolism , Mutation/genetics , Gene Expression Regulation, Plant , Cold Temperature
11.
Front Bioeng Biotechnol ; 11: 1093926, 2023.
Article En | MEDLINE | ID: mdl-36815889

In the process of orthodontic treatment, the presence of orthodontic appliances makes it difficult to clean tooth surfaces. This can lead to an increased level of bacterial colonization, resulting in enamel demineralization and periodontal diseases. Considering the large surface area that orthodontic appliances usually have and that they can be in direct contact with bacteria throughout the treatment, modifications in the form of coatings on the surface of orthodontic appliances can be an effective and practical approach to reducing bacterial proliferation and preventing relevant adverse effects. In this mini-review, we discuss various antibacterial coatings which have been applied onto orthodontic appliances in recent 5 years, as well as their antibacterial mechanisms and methods for the preparation of these coatings. From this mini-review, both orthodontists and researchers can get the latest findings in the field of antibacterial coatings onto orthodontic appliances, which is helpful for the decision-making in clinical practice and research activities.

12.
Genes (Basel) ; 13(11)2022 11 01.
Article En | MEDLINE | ID: mdl-36360235

Hypertension is an independent risk factor for atherosclerosis. However, few models of hypertensive atherosclerosis have been established in medical research. In this study, we crossed the ApoE knockout (ApoE-KO; ApoE-/-) atherosclerotic mouse model with the NOS3 knockout (NOS3-KO; NOS3-/-) hypertensive mouse model to establish an ApoE/NOS3 double knockout (ApoE/NOS3-KO; ApoE/NOS3-/-) hypertensive atherosclerosis mouse model. We found that ApoE/NOS3-/- mice reproduced normally, had a blood pressure of 133.00 ± 3.85 mmHg, and developed hypertensive fundus retinopathy and hypertensive nephropathy. In addition, serum total cholesterol (TC) and low-density lipoprotein (LDL) levels in the blood were abnormally elevated, steatosis was observed in the liver cells, and atherosclerotic lesions were observed in the aortic vessels in ApoE/NOS3-/- adult mice. In conclusion, ApoE/NOS3-/- adult mice are a satisfactory model of hypertension and atherosclerosis and can be utilized for studies on cardiovascular diseases.


Atherosclerosis , Cardiovascular Diseases , Hypertension , Mice , Animals , Mice, Knockout, ApoE , Mice, Knockout , Atherosclerosis/genetics , Apolipoproteins E/genetics , Hypertension/genetics , Nitric Oxide Synthase Type III
13.
Dent Mater ; 38(11): 1728-1741, 2022 11.
Article En | MEDLINE | ID: mdl-36137833

OBJECTIVES: To develop a multifunctional orthodontic adhesive (QDA) using ZnO quantum-dots (ZnQDs) as modifier and investigate the antibacterial capability, fluorescence property as well as biocompatibility and bonding property. METHODS: ZnQDs were synthesized using sol-gel method. XPS, XRD, FT-IR, HRTEM, SAED, DLS and spectrofluorimetry were used to characterize ZnQDs. ZnQDs were incorporated into Transbond XT adhesive paste with 20 %, 30 %, 40 % mass fraction, respectively, to form the multifunctional adhesives (QDAs). Antibacterial capability was evaluated with MTT kit, CFU count and Live/Dead Bacterial Staining Kit. Ultraviolet photography and spectrofluorimetry were used to confirm the fluorescence property of QDAs. Biocompatibility assay was performed on gingival fibroblasts and subcutaneous tissue of rats. Softening in solvent rate, shear bond strength and degree of conversion (DC) were measured. RESULTS: The synthesized ZnQDs presented excellent crystallinity and fluorescence properties. MTT assay, CFU count and CLSM analysis indicated that QDAs had significant antibacterial activity compared with Transbond XT adhesive paste. CCK-8 assay and Live/Dead cell staining analysis denied the cytotoxicity of QDAs and histological analysis proved that QDAs all had no inflammatory irritation to subcutaneous tissue. Softening in solvent, shear bond strength and DC evaluations indicated that 20 % mixing ratio of ZnQDs could enhance the resistance to degradation without influencing the bond strength and DC. Ultraviolet photography and spectrofluorimetry analysis proved the fluorescence capability of QDAs. SIGNIFICANCE: ZnQDs can impart antibacterial and fluorescence properties to orthodontic adhesives without affecting biocompatibility and bonding performance. QDAs can be multifunctional orthodontic adhesives to reduce bacterial adhesion around brackets and help orthodontists remove residual adhesives precisely when needed.


Dental Bonding , Orthodontic Brackets , Zinc Oxide , Animals , Rats , Adhesives , Anti-Bacterial Agents/pharmacology , Dental Bonding/methods , Dental Cements/chemistry , Dental Stress Analysis , Materials Testing , Resin Cements/chemistry , Shear Strength , Solvents , Spectroscopy, Fourier Transform Infrared , Quantum Dots
14.
Front Bioeng Biotechnol ; 10: 853436, 2022.
Article En | MEDLINE | ID: mdl-35646855

Enamel demineralization, as a type of frequently-occurring dental problem that affects both the health and aesthetics of patients, is a concern for both dental professionals and patients. The main chemical composition of the enamel, hydroxyapatite, is easy to be dissolved under acid attack, resulting in the occurrence of enamel demineralization. Among agents for the preventing or treatment of enamel demineralization, amorphous calcium phosphate (ACP) has gradually become a focus of research. Based on the nonclassical crystallization theory, ACP can induce the formation of enamel-like hydroxyapatite and thereby achieve enamel remineralization. However, ACP has poor stability and tends to turn into hydroxyapatite in an aqueous solution resulting in the loss of remineralization ability. Therefore, ACP needs to be stabilized in an amorphous state before application. Herein, ACP stabilizers, including amelogenin and its analogs, casein phosphopeptides, polymers like chitosan derivatives, carboxymethylated PAMAM and polyelectrolytes, together with their mechanisms for stabilizing ACP are briefly reviewed. Scientific evidence supporting the remineralization ability of these ACP agents are introduced. Limitations of existing research and further prospects of ACP agents for clinical translation are also discussed.

15.
Front Bioeng Biotechnol ; 10: 836042, 2022.
Article En | MEDLINE | ID: mdl-35284411

Objective: To systematically review in vitro studies that evaluated the effects of plant extracts on dentin bonding strength. Materials and Methods: Six electronic databases (PubMed, Embase, VIP, CNKI, Wanfang and The Cochrane Library) were searched from inception to September 2021 in accordance with the Preferred Reporting Items for Systematic Reviews (PRISMA). In vitro studies that compared the performance of dental adhesives with and without the plant extracts participation were included. The reference lists of the included studies were manually searched. Two researchers carried out study screening, data extraction and risk of bias assessment, independently and in duplicate. Meta-analysis was conducted using Review Manager 5.3. Results: A total of 62 studies were selected for full-text analysis. 25 articles used the plant extracts as primers, while five added the plant extracts into adhesives. The meta-analysis included 14 articles of in vitro studies investigating the effects of different plant extract primers on dentin bonding strength of etch-and-rinse and self-etch adhesives, respectively. The global analysis showed statistically significant difference between dental adhesives with and without plant extract primers. It showed that the immediate bond strength of dental adhesives was improved with the application of plant extract primers. Conclusion: The application of proanthocyanidin (PA) primers have positive effect on the in vitro immediate bonding strength of dental adhesives irrespective of etch-and-rinse or self-etch modes.

16.
New Phytol ; 233(5): 2127-2143, 2022 03.
Article En | MEDLINE | ID: mdl-34936108

Plants have evolved sophisticated regulatory networks to cope with dynamically changing light and temperature environments during day-night and seasonal cycles. However, the integration mechanisms of light and low temperature remain largely unclear. Here, we show that low red : far-red ratio (LR : FR) induces FAR-RED ELONGATED HYPOCOTYL3 (SlFHY3) transcription under cold stress in tomato (Solanum lycopersicum). Reverse genetic approaches revealed that knocking out SlFHY3 decreases myo-inositol accumulation and increases cold susceptibility, whereas overexpressing SlFHY3 induces myo-inositol accumulation and enhances cold tolerance in tomato plants. SlFHY3 physically interacts with ELONGATED HYPOCOTYL5 (SlHY5) to promote the transcriptional activity of SlHY5 on MYO-INOSITOL-1-PHOSPHATE SYNTHASE 3 (SlMIPS3) and induce myo-inositol accumulation in tomato plants under cold stress. Disruption of SlHY5 and SlMIPS3 largely suppresses the cold tolerance of SlFHY3-overexpressing plants and myo-inositol accumulation in tomato. Furthermore, silencing of SlMIPS3 drastically reduces myo-inositol accumulation and compromises LR : FR-induced cold tolerance in tomato. Together, our results reveal a crucial role of SlFHY3 in LR : FR-induced cold tolerance in tomato and unravel a novel regulatory mechanism whereby plants integrate dynamic environmental light signals and internal cues (inositol biosynthesis) to induce and control cold tolerance in tomato plants.


Solanum lycopersicum , Cold Temperature , Gene Expression Regulation, Plant , Inositol , Light Signal Transduction , Solanum lycopersicum/genetics
17.
Article Zh | WPRIM | ID: wpr-942767

@#With the deepening of research in oral microbiomics, an important relationship between changes in the oral microbiome and orthodontic treatment has been found. Orthodontic treatment will have an impact on the oral and systemic microbiome. The presence of oral appliances can change the quantity and quality of the oral microbiometo and increase the risk of oral and even systemic diseases in patients undergoing orthodontic treatment. Compared with fixed orthodontic treatment, clear aligners will not have a harmful impact on the structure of the oral microbiome, which is more conducive to maintain oral health during the orthodontic treatment process. In addition, different bracket types and materials can lead to different changes in the oral microbiome, and the occurrence and development of orthodontic-related diseases, such as white spot lesions, dental caries, gingivitis and periodontitis, are also related to changes in the oral microbiome. At present, the role of the oral microbiome in the process of orthodontic treatment needs to be further studied. Whether a change in the oral microbiome caused by orthodontic treatment can be restored after orthodontic treatment is still uncertain and needs more research. This paper reviews the research progress on the application of microbiomics in orthodontics, including the impact of fixed appliances and clear aligners on the microbiome and the relationship between orthodontic-related diseases and the oral microbiome.

18.
Article Zh | WPRIM | ID: wpr-923371

@#Enamel demineralization is one of the most common adverse reactions to orthodontic treatment. The existence of orthodontic appliances affects oral hygiene maintenance, which easily leads to plaque accumulation and oral flora dysbiosis, and cariogenic bacteria produce acid to cause enamel demineralization. It not only affects aesthetics but may develop into caries and endanger oral health. Therefore, enamel demineralization has become an urgent problem. Nanoparticles generally refer to solid particles with diameters of 1 to 100 nm and have unique physicochemical properties that provide a new strategy for preventing enamel demineralization during orthodontics. Reviewing the relevant literature, nanoparticles used for the prevention of enamel demineralization in orthodontics may be classified into antibacterial, remineralization and carrier-type nanoparticles according to their functions. Most research was performed on the application of nanoparticles to modify orthodontic adhesives for enhancement of antibacterial or remineralization properties, but some studies also focused on the modification of orthodontic appliances with nanoparticles for surface coating or overall doping to provide antimicrobial properties. The advantage of these two approaches is that they are not dependent on patient compliance. Nanoparticle-modified fluoride varnishes and nanocarriers loaded with antimicrobial or remineralization agents may be used to promote oral health care in orthodontic patients, which have a sustained preventive effect but depend on the cooperation of the patient. It was indicated that the small size effect of nanoparticles provides better performance, but there may be certain safety issues, and there is still some influence on the physicochemical properties of the modified materials themselves. These issues must be further explored. Although there are some limitations in the current studies, nanoparticles are expected to play an important role in the prevention of enamel demineralization during orthodontics in the future.

19.
Diagnostics (Basel) ; 11(8)2021 Jul 31.
Article En | MEDLINE | ID: mdl-34441320

Adenoid hypertrophy may lead to pediatric obstructive sleep apnea and mouth breathing. The routine screening of adenoid hypertrophy in dental practice is helpful for preventing relevant craniofacial and systemic consequences. The purpose of this study was to develop an automated assessment tool for adenoid hypertrophy based on artificial intelligence. A clinical dataset containing 581 lateral cephalograms was used to train the convolutional neural network (CNN). According to Fujioka's method for adenoid hypertrophy assessment, the regions of interest were defined with four keypoint landmarks. The adenoid ratio based on the four landmarks was used for adenoid hypertrophy assessment. Another dataset consisting of 160 patients' lateral cephalograms were used for evaluating the performance of the network. Diagnostic performance was evaluated with statistical analysis. The developed system exhibited high sensitivity (0.906, 95% confidence interval [CI]: 0.750-0.980), specificity (0.938, 95% CI: 0.881-0.973) and accuracy (0.919, 95% CI: 0.877-0.961) for adenoid hypertrophy assessment. The area under the receiver operating characteristic curve was 0.987 (95% CI: 0.974-1.000). These results indicated the proposed assessment system is able to assess AH accurately. The CNN-incorporated system showed high accuracy and stability in the detection of adenoid hypertrophy from children' lateral cephalograms, implying the feasibility of automated adenoid hypertrophy screening utilizing a deep neural network model.

20.
Front Plant Sci ; 12: 698525, 2021.
Article En | MEDLINE | ID: mdl-34290726

Perceiving incoming environmental information is critical for optimizing plant growth and development. Multiple B-box proteins (BBXs) play essential roles in light-dependent developmental processes in plants. However, whether BBXs function as a signal integrator between light and temperature in tomato plants remains elusive. In this study, 31 SlBBX genes were identified from the newly released tomato (Solanum lycopersicum) genome sequences and were clustered into five subgroups. Gene structure and protein motif analyses showed relatively high conservation of closely clustered SlBBX genes within each subgroup; however, genome mapping analysis indicated the uneven distribution of the SlBBX genes on tomato chromosomes. Promoter cis-regulatory elements prediction and gene expression indicated that SlBBX genes were highly responsive to light, hormones, and stress conditions. Reverse genetic approaches revealed that disruption of SlBBX7, SlBBX9, and SlBBX20 largely suppressed the cold tolerance of tomato plants. Furthermore, the impairment of SlBBX7, SlBBX9, and SlBBX20 suppressed the photosynthetic response immediately after cold stress. Due to the impairment of non-photochemical quenching (NPQ), the excess photon energy and electron flow excited by low temperature were not consumed in SlBBX7-, SlBBX9-, and SlBBX20- silenced plants, leading to the over reduction of electron carriers and damage of the photosystem. Our study emphasized the positive roles of light signaling transcription factors SlBBXs in cold tolerance in tomato plants, which may improve the current understanding of how plants integrate light and temperature signals to adapt to adverse environments.

...