Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
1.
Appl Opt ; 63(5): 1306-1312, 2024 Feb 10.
Article En | MEDLINE | ID: mdl-38437310

A broadband and narrowband switchable terahertz (THz) absorber based on a bulk Dirac semimetal (BDS) and strontium titanate (STO) is proposed. Narrowband and broadband absorption can be switched by adjusting the Fermi level of the BDS. When the Fermi level of the BDS is 100 meV, the device is an absorber with three narrowband absorption peaks. The frequencies are 0.44, 0.86, and 1.96 THz, respectively, when the temperature of STO is 250 K. By adjusting the temperature of STO from 250 to 500 K, the blue shifts of the frequencies are approximately 0.14, 0.32, and 0.60 THz, respectively. The sensitivities of the three absorption peaks are 0.56, 1.27, and 2.38 GHz/K, respectively. When the Fermi level of the BDS is adjusted from 100 to 30 meV, the device can be switched to a broadband absorber with a bandwidth of 0.70 THz. By adjusting the temperature of STO from 250 to 500 K, the central frequency shifts from 1.40 to 1.79 THz, and the bandwidth broadens from 0.70 to 0.96 THz. The sensitivity of the central frequency is 1.57 GHz/K. The absorber also has a wide range of potential applications in multifunctional tunable devices, such as temperature sensors, stealth equipment, and filters.

2.
Appl Opt ; 62(21): 5822-5829, 2023 Jul 20.
Article En | MEDLINE | ID: mdl-37707202

In this study, a perfect metamaterial absorber based on strontium titanate and bulk Dirac semimetals is proposed. When the temperature of strontium titanate was 300K, the dual-band absorptions were 99.74% and 99.99% at 1.227 and 1.552 THz, respectively. The sensitivities based on a transverse magnetic (TM) wave were 0.95 and 1.22 GHz/K; the sensitivity based on a transverse electric (TE) wave was 0.76 GHz/K. The TE and TM waves were modulated by inserting a bulk Dirac semimetal between the concave and convex devices. The modulation depth of the TE wave was 97.9% at 1.1 THz; the extinction ratio was 16.9 dB. The modulation depth of the TE wave at 1.435 THz was 95.9%; the extinction ratio was 13.89 dB. The TM wave modulation depth at 1.552 THz was 95.9%; the extinction ratio was 13.98 dB. Irrespective of a TE or TM wave, the terahertz absorber has good switching and temperature-sensing performance based on strontium titanate and bulk Dirac semimetals as well as broad application prospects in temperature sensing and switching devices.

3.
Appl Opt ; 62(3): 813-819, 2023 Jan 20.
Article En | MEDLINE | ID: mdl-36821288

In this paper, a multifunctional terahertz (THz) absorber based on Dirac semimetal and vanadium dioxide (V O 2) is proposed. By modulating the temperature of V O 2, the absorber can be switched between the narrow band and wide band. When V O 2 is in the metallic state, the absorber has a broadband absorption effect with a bandwidth of approximately 4 THz. It has the advantages of insensitivity to polarization and wide-angle absorption. When V O 2 is in the insulating state, the absorber has two absorption peaks with absorptivity exceeding 90% and sensitivities of 297.7 and 402 GHz/RIU, and thus can be used as a highly sensitive sensor for cell detection. When the Fermi level of the Dirac semimetal is changed, the absorption characteristics can be modulated. The absorber has broad application prospects in multifunctional modulated devices.

4.
Exp Ther Med ; 19(5): 3432-3438, 2020 May.
Article En | MEDLINE | ID: mdl-32266043

The objective of the present study was to explore the role of hepatocyte growth factor (HGF) in directing treatment of Mycoplasma pneumoniae pneumonia (MP). Serum levels of HGF were assessed using ELISA in 65 pediatric patients with MP, 42 with bacterial pneumonia and 30 healthy controls. Serum levels of C-reactive protein (CRP), the standard guide for MP treatment, were also examined in severe and non-severe MP. The sensitivity and specificity of HGF and CRP in assessing the outcome of azithromycin treatment of MP were compared using receiver operating characteristic curves. HGF levels were elevated in MP and bacterial pneumonia patients compared with healthy controls. HGF levels were also significantly higher in severe MP than in non-severe MP. HGF showed higher sensitivity and specificity than CRP in assessing outcomes of azithromycin treatment of MP. The results of the present study indicated that HGF may be used to detect severe MP and to direct its management. Furthermore, HGF may be better predictive marker to assess the effectiveness of azithromycin treatment of MP than CRP.

...