Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cancer Res ; 82(21): 4093-4104, 2022 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-36098983

RESUMEN

Breast-conserving surgery (BCS) is commonly used for the treatment of early-stage breast cancer. Following BCS, approximately 20% to 30% of patients require reexcision because postoperative histopathology identifies cancer in the surgical margins of the excised specimen. Quantitative micro-elastography (QME) is an imaging technique that maps microscale tissue stiffness and has demonstrated a high diagnostic accuracy (96%) in detecting cancer in specimens excised during surgery. However, current QME methods, in common with most proposed intraoperative solutions, cannot image cancer directly in the patient, making their translation to clinical use challenging. In this proof-of-concept study, we aimed to determine whether a handheld QME probe, designed to interrogate the surgical cavity, can detect residual cancer directly in the breast cavity in vivo during BCS. In a first-in-human study, 21 BCS patients were scanned in vivo with the QME probe by five surgeons. For validation, protocols were developed to coregister in vivo QME with postoperative histopathology of the resected tissue to assess the capability of QME to identify residual cancer. In four cavity aspects presenting cancer and 21 cavity aspects presenting benign tissue, QME detected elevated stiffness in all four cancer cases, in contrast to low stiffness observed in 19 of the 21 benign cases. The results indicate that in vivo QME can identify residual cancer by directly imaging the surgical cavity, potentially providing a reliable intraoperative solution that can enable more complete cancer excision during BCS. SIGNIFICANCE: Optical imaging of microscale tissue stiffness enables the detection of residual breast cancer directly in the surgical cavity during breast-conserving surgery, which could potentially contribute to more complete cancer excision.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Mastectomía Segmentaria , Neoplasia Residual , Femenino , Humanos , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Diagnóstico por Imagen de Elasticidad/métodos , Márgenes de Escisión , Mastectomía Segmentaria/métodos , Neoplasia Residual/diagnóstico por imagen
2.
Sci Rep ; 10(1): 15951, 2020 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-32994500

RESUMEN

Optical elastography is undergoing extensive development as an imaging tool to map mechanical contrast in tissue. Here, we present a new platform for optical elastography by generating sub-millimetre-scale mechanical contrast from a simple digital camera. This cost-effective, compact and easy-to-implement approach opens the possibility to greatly expand applications of optical elastography both within and beyond the field of medical imaging. Camera-based optical palpation (CBOP) utilises a digital camera to acquire photographs that quantify the light intensity transmitted through a silicone layer comprising a dense distribution of micro-pores (diameter, 30-100 µm). As the transmission of light through the micro-pores increases with compression, we deduce strain in the layer directly from intensity in the digital photograph. By pre-characterising the relationship between stress and strain of the layer, the measured strain map can be converted to an optical palpogram, a map of stress that visualises mechanical contrast in the sample. We demonstrate a spatial resolution as high as 290 µm in CBOP, comparable to that achieved using an optical coherence tomography-based implementation of optical palpation. In this paper, we describe the fabrication of the micro-porous layer and present experimental results from structured phantoms containing stiff inclusions as small as 0.5 × 0.5 × 1 mm. In each case, we demonstrate high contrast between the inclusion and the base material and validate both the contrast and spatial resolution achieved using finite element modelling. By performing CBOP on freshly excised human breast tissue, we demonstrate the capability to delineate tumour from surrounding benign tissue.

3.
Cancer Res ; 80(8): 1773-1783, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-32295783

RESUMEN

Inadequate margins in breast-conserving surgery (BCS) are associated with an increased likelihood of local recurrence of breast cancer. Currently, approximately 20% of BCS patients require repeat surgery due to inadequate margins at the initial operation. Implementation of an accurate, intraoperative margin assessment tool may reduce this re-excision rate. This study determined, for the first time, the diagnostic accuracy of quantitative micro-elastography (QME), an optical coherence tomography (OCT)-based elastography technique that produces images of tissue microscale elasticity, for detecting tumor within 1 mm of the margins of BCS specimens. Simultaneous OCT and QME were performed on the margins of intact, freshly excised specimens from 83 patients undergoing BCS and on dissected specimens from 7 patients undergoing mastectomy. The resulting three-dimensional images (45 × 45 × 1 mm) were coregistered with postoperative histology to determine tissue types present in each scan. Data from 12 BCS patients and the 7 mastectomy patients served to build a set of images for reader training. One hundred and fifty-four subimages (10 × 10 × 1 mm) from the remaining 71 BCS patients were included in a blinded reader study, which resulted in 69.0% sensitivity and 79.0% specificity using OCT images, versus 92.9% sensitivity and 96.4% specificity using elasticity images. The quantitative nature of QME also facilitated development of an automated reader, which resulted in 100.0% sensitivity and 97.7% specificity. These results demonstrate high accuracy of QME for detecting tumor within 1 mm of the margin and the potential for this technique to improve outcomes in BCS. SIGNIFICANCE: An optical imaging technology probes breast tissue elasticity to provide accurate assessment of tumor margin involvement in breast-conserving surgery.


Asunto(s)
Adenocarcinoma Mucinoso/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Márgenes de Escisión , Mastectomía Segmentaria/métodos , Adenocarcinoma Mucinoso/patología , Adenocarcinoma Mucinoso/cirugía , Adulto , Anciano , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Diagnóstico por Imagen de Elasticidad/normas , Femenino , Humanos , Mastectomía Segmentaria/normas , Persona de Mediana Edad , Reoperación , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA