Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Patient Exp ; 8: 23743735211048054, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34722867

RESUMEN

To curb transmission of SARS-CoV-2 and preserve hospital resources, elective procedures were postponed in the United States, affecting patients previously scheduled for electrophysiology (EP) procedures. We aimed to understand patients' perceptions related to procedural postponements during the first wave of the SARS-CoV-2 pandemic. We performed a telephone survey between May 1-15 2020, of consecutive patients who experienced procedural postponement from March-April. Of 112 patients, 20% may have been lost to follow up and 12% lost interest in having their procedures done. The level of anxiety related to postponement was moderate to high in more than two thirds of patients.

2.
Pacing Clin Electrophysiol ; 44(7): 1143-1150, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33959994

RESUMEN

PURPOSE: Non-white patients are underrepresented in left atrial appendage occlusion (LAAO) trials, and racial disparities in LAAO periprocedural management are unknown. METHODS: We assessed sociodemographics and comorbidities of consecutive patients at our institution undergoing LAAO between 2015 and 2020, then in adjusted analyses, compared procedural wait time, procedural complications, and post-procedure oral anticoagulation (OAC) use in whites versus non-whites. RESULTS: Among 109 patients undergoing LAAO (45% white), whites had lower CHA2 DS2 VASc scores, on average, than non-whites (4.0 vs. 4.8, p = .006). There was no difference in median time from index event (IE) or initial outpatient cardiology encounter to LAAO procedure (whites 10.5 vs. non-whites 13.7 months, p = .9; 1.9 vs. 1.8 months, p = .6, respectively), and there was no difference in procedural complications (whites 4% vs. non-whites 5%, p = .33). After adjusting for CHA2 DS2 VASc score, OAC use at discharge tended to be higher in whites (OR 2.4, 95% CI [0.9-6.0], p = .07). When restricting the analysis to those with prior gastrointestinal (GI) bleed, adjusting for CHA2 DS2 VASc score and GI bleed severity, whites had a nearly five-fold odds of being discharged on OAC (OR 4.6, 95% CI [1-21.8], p = 0.05). The association between race and discharge OAC was not mediated through income category (total mediation effect 19% 95% CI [-.04-0.11], p = .38). CONCLUSION: Despite an increased prevalence of comorbidities amongst non-whites, wait time for LAAO and procedural complications were similar in whites versus non-whites. Among those with prior GI bleed, whites were nearly five-fold more likely to be discharged on OAC than non-whites, independent of income.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos , Etnicidad , Complicaciones Posoperatorias/epidemiología , Grupos Raciales , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atención Perioperativa , Estudios Retrospectivos , Factores de Tiempo , Listas de Espera
3.
Heart Rhythm ; 18(6): 847-852, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33524625

RESUMEN

BACKGROUND: The incidence of atrial fibrillation (AF) is lower in nonwhites than in whites despite a higher burden of AF risk factors. However, the incidence of new AF after cryptogenic stroke in minorities is unknown. OBJECTIVE: The purpose of this study was to determine the incidence of AF after cryptogenic stroke in different racial/ethnic groups. METHODS: We retrospectively analyzed 416 consecutive patients undergoing insertable cardiac monitor implantation at our hospital from 2014 through 2019. Incidence of AF was identified through the review of device monitoring, including adjudication of AF episodes for accuracy, and compared by race. RESULTS: The mean follow-up time was 1.5 ± 1.1 years. The predominantly nonwhite cohort included 244 (59%) blacks and 109 (26%) Hispanics, and 45% (n=189) were male. The mean age was 62 ± 12 years; Blacks and Hispanics had more hypertension, diabetes, and chronic kidney disease and higher body mass index than did whites. In blacks and Hispanics, the cumulative incidences of AF at 1, 2, and 3 years were 14.1%, 19.9%, and 24% and 12.9%, 18.3%, and 20.9%, respectively. By comparison, the incidence in whites was significantly higher: 20.8%, 34.3%, and 40.3%. In a Cox proportional hazards model adjusting for common AF risk factors, blacks (hazard ratio 0.49; confidence interval 0.26-0.82; P = .03) and Hispanics (hazard ratio 0.39; confidence interval 0.18-0.83; P = .01) were less likely to have incident AF than whites. CONCLUSION: In patients with an insertable cardiac monitor after cryptogenic stroke, the incidence of newly detected AF is approximately double in whites compared with both blacks and Hispanics. This has important implications for the investigation and treatment of nonwhites with cryptogenic stroke.


Asunto(s)
Fibrilación Atrial/etnología , Electrocardiografía , Accidente Cerebrovascular Isquémico/complicaciones , Grupos Raciales , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Incidencia , Accidente Cerebrovascular Isquémico/etnología , Masculino , Persona de Mediana Edad , Factores Raciales , Estudios Retrospectivos , Factores de Riesgo , Estados Unidos/epidemiología
4.
Am J Cardiol ; 129: 36-41, 2020 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-32565090

RESUMEN

Electrolyte abnormalities are a known trigger for ventricular arrhythmia, and patients with heart disease on diuretic therapy may be at higher risk for electrolyte depletion. Our aim was to determine the prevalence of electrolyte depletion in patients presenting to the hospital with sustained ventricular tachycardia or ventricular fibrillation (VT/VF) versus heart failure, and identify risk factors for electrolyte depletion. Consecutive admissions to a tertiary care hospital for VT/VF were identified between July 2016 and October 2018 using the electronic medical record and compared with an equal number of consecutive admissions for heart failure (CHF). The study included 280 patients (140 patients in each group; mean age 63, 60% male, 59% African American). Average EF in the VT/VF and CHF groups was 30% and 33%, respectively. Hypokalemia (K < 3.5 mmol/L) and severe hypokalemia (K < 3.0 mmol/L) were present in 35.7% and 13.6%, respectively, of patients with VT/VF, compared to 12.9% and 2.7% of patients with CHF (p < 0.001 and p = 0.001, respectively, between groups). Hypomagnesemia was found in 7.8% and 5.8% of VT/VF and CHF patients, respectively (p = 0.46). Gastrointestinal illness and recent increases in diuretic dose were strongly associated with severe hypokalemia in VT/VF patients (odds ratio: 11.1 and 21.9, respectively; p < 0.001). In conclusion, hypokalemia is extremely common in patients presenting with VT/VF, much more so than in patients with CHF alone. Preceding gastrointestinal illness and increase in diuretic dose were strongly associated with severe hypokalemia in the VT/VF population, revealing a potential opportunity for early intervention and arrhythmia risk reduction.


Asunto(s)
Diuréticos/administración & dosificación , Insuficiencia Cardíaca/epidemiología , Hipopotasemia/epidemiología , Magnesio/sangre , Taquicardia Ventricular/epidemiología , Fibrilación Ventricular/epidemiología , Anciano , Cardiomiopatías/epidemiología , Estudios de Casos y Controles , Diarrea/epidemiología , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Hipopotasemia/sangre , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/epidemiología , Náusea/epidemiología , Insuficiencia Renal Crónica/epidemiología , Índice de Severidad de la Enfermedad , Inhibidores de los Simportadores del Cloruro de Sodio/administración & dosificación , Inhibidores del Simportador de Cloruro Sódico y Cloruro Potásico/administración & dosificación , Espironolactona/administración & dosificación , Volumen Sistólico , Taquicardia Ventricular/sangre , Fibrilación Ventricular/sangre , Vómitos/epidemiología , Desequilibrio Hidroelectrolítico/sangre , Desequilibrio Hidroelectrolítico/epidemiología
5.
JACC Case Rep ; 2(14): 2244-2248, 2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-34317149

RESUMEN

Atrial fibrillation (AF) is a triggered rhythm, and ablation of the trigger is a common strategy for rhythm control. We describe a patient with symptomatic AF who was found to have episodes of AF triggered by premature ventricular complexes, likely by retrograde atrioventricular nodal conduction. (Level of Difficulty: Beginner.).

6.
Pacing Clin Electrophysiol ; 36(4): 444-50, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23330676

RESUMEN

BACKGROUND: Percutaneous extraction of standard implantable cardioverter-defibrillator leads is often complicated by ingrowth of fibrotic tissue into the shocking coils. Leads with GORE™ expanded polytetrafluoroethylene (ePTFE) coating (W. L. Gore & Associates, Inc., Newark, DE, USA) designed to inhibit fibrosis are in use, but clinical data regarding their extraction are lacking. The study's purpose was to examine the feasibility, efficacy, and safety of percutaneous extraction involving defibrillator leads coated with ePTFE. METHODS: We analyzed our database to identify all percutaneously extracted leads with ePTFE-coated shocking coils. Lead and procedure characteristics were compared to a cohort of noncoated leads of similar implant duration. RESULTS: One hundred fifty-six leads were extracted from 145 patients; 57 ePTFE-coated leads, with a mean implant duration of 621 days, were extracted and compared to 99 noncoated leads, with a mean implant duration of 763 days (P = 0.0641). Mean extraction time was 5 minutes for coated leads versus 9.75 minutes for noncoated leads (P = 0.0001). Extraction time of less than 1 minute was more frequent with coated leads (61% vs 35%, P = 0.0025). Adjunct extraction tools were required less frequently with coated leads than noncoated leads (39% vs 63%, P = 0.0071). There was no fibrosis where ePTFE covered the shocking coils. Alternatively, 23 of 99 (23%) noncoated leads demonstrated fibrosis adherent to the shock coil. There were no procedure-related complications in either group. CONCLUSIONS: Compared to noncoated leads, ePTFE-coated leads are associated with shorter extraction times and are less likely to require extraction tools for removal. The difference is likely related to the absence of fibrosis over the ePTFE-coated high-energy coils.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Electrodos Implantados , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles Revestidos , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Estudios Retrospectivos , Estadísticas no Paramétricas , Factores de Tiempo
7.
J Am Coll Cardiol ; 55(9): 886-94, 2010 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-20185039

RESUMEN

OBJECTIVES: We describe the feasibility, safety, and clinical outcomes of percutaneous lead extraction in patients at a tertiary care center who had intracardiac vegetations identified by transesophageal echocardiogram. BACKGROUND: Infection in the presence of intracardiac devices is a problem of considerable morbidity and mortality. Patients with intracardiac vegetations are at high risk for complications related to extraction and protracted clinical courses. Historically, lead extraction in this cohort has been managed by surgical thoracotomy. METHODS: We analyzed percutaneous lead extractions performed from January 1991 to September 2007 in infected patients with echocardiographic evidence of intracardiac vegetations, followed by a descriptive and statistical analysis. RESULTS: A total of 984 patients underwent extraction of 1,838 leads; local or systemic infection occurred in 480 patients. One hundred patients had intracardiac vegetations identified by transesophageal echocardiogram, and all underwent percutaneous lead extraction (215 leads). Mean age was 67 years. Median extraction time was 3 min per lead; median implant duration was 34 months. During the index hospitalization, a new device was implanted in 54 patients at a median of 7 days after extraction. Post-operative 30-day mortality was 10%; no deaths were related directly to the extraction procedure. CONCLUSIONS: Patients with intracardiac vegetations identified on transesophageal echocardiogram can safely undergo complete device extraction using standard percutaneous lead extraction techniques. Permanent devices can safely be reimplanted provided blood cultures remain sterile. The presence of intracardiac vegetations identifies a subset of patients at increased risk for complications and early mortality from systemic infection despite device extraction and appropriate antimicrobial therapy.


Asunto(s)
Cateterismo/métodos , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Taquicardia/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ecocardiografía Transesofágica , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pennsylvania/epidemiología , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA