Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Niger J Clin Pract ; 24(12): 1855-1858, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34889797

RESUMEN

Intrapelvic migration of total hip prosthesis is a rare but severe complication of total hip arthroplasty that can cause severe outcomes for elderly patients. A 78-year-old female patient was referred to our hospital with the complaint of no gas-stool excretion for 3-4 days, abdominal distension, nausea, vomiting, and a preliminary diagnosis of ileus. Computed tomography showed the migration of the left total hip prosthesis to the pelvis, causing a hematoma around the prosthesis and mechanical ileus due to the compression of the hematoma. To our knowledge, this case report is the only reported mechanic ileus due to migration of total hip prosthesis. Although postop paralytic ileus is one of the complications of total hip arthroplasty, mechanical ileus has not been described before. This case report shows that mechanical ileus might be an unreported complication of total hip arthroplasty. It should be kept in mind that mechanical ileus complications may also occur after hip arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Ileus , Obstrucción Intestinal , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Ileus/diagnóstico por imagen , Ileus/etiología , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA